North Slope Chillers NSC0500, NSC1000, NSC2000, NSC1000-LT, NSC2000-LT Instruction Manual

Freeze Owner’s Manual 1 | P a g e
www.northslopechillers.com | (866) 826-2993 | 3130 S 1030 W, Suite 1 | Salt Lake City, UT 84119
Revised: 05/31/2018
Freeze Owner’s Manual 2 | P a g e
Table of Contents
Applications ................................................................................................................................................ 3
Cautions/Warnings ...................................................................................................................................... 3
Specification sheet ...................................................................................................................................... 4
Chiller Component Overview ....................................................................................................................... 5
Installation .................................................................................................................................................. 6
User Interface .............................................................................................................................................. 7
Modifying Parameters ................................................................................................................................. 8
Setting Temperature Units (F or C) .............................................................................................................................. 8
Modifying Set Point (St1) ................................................................................................................................................ 8
Modifying Temperature Differentials (P1 ) ..................................................................................................................... 8
Modifying Operating Parameters ................................................................................................................................... 8
LIMITED WARRANTY POLICY ...................................................................................................................... 10
www.northslopechillers.com | (866) 826-2993 | 3130 S 1030 W, Suite 1 | Salt Lake City, UT 84119
Revised: 05/31/2018
Freeze Owner’s Manual 3 | P a g e
TYPE
MODEL NUMBER
COOLING CAPACTIY (BTU/HR)
Freeze
NSC0500
6,000 (1/2 ton)
Freeze
NSC1000
12,000 (1 ton)
Freeze
NSC2000
24,000 (2 ton)
Deep Freeze
NSC1000-LT
12,000 (1 ton)
Deep Freeze
NSC 2000-LT
24,000 (2 ton)
Applications
This owner’s manual is to be used for the following North Slope Chillers:
Cautions/Warnings
1. Power (ALWAYS check the Chiller Parameter tag and verify operational voltage before plugging in chiller) a. Only connect North Slope Chillers to a properly grounded circuit b. Never connect your North Slope Chiller to voltage that is outside the acceptable voltage range.
Connecting your chiller to any voltage outside of these ranges will damage the compressor.
i. 110V model will operate on voltages between 100 ~ 130V
ii. 230V model will operate on voltages between 200 ~ 250V
c. Only use power sources that are 60Hz, running the chiller at 50Hz will void the warranty and will
damage the compressor
2. Never run the pump dry, only turn on chiller after the fluid reservoir has been filled. Running the chiller without
fluid will permanently damage the pump and void the warranty
3. This chiller is air cooled and must have good ventilation. For proper function there must be a minimum of 1
foot clearance on both sides and 2 foot clearance at the back of the chiller
4. Flush chiller prior to use. North Slope Chillers tests every chiller on site prior to shipping. During testing North
Slope Chillers uses a water/glycol mix to test their chillers. There will always be a small amount of water/glycol remaining in the system. Since not all glycols are compatible with each other and vary by manufacture each chiller should be flushed with water for 10 minutes prior to use.
www.northslopechillers.com | (866) 826-2993 | 3130 S 1030 W, Suite 1 | Salt Lake City, UT 84119
Revised: 05/31/2018
Freeze Owner’s Manual 4 | P a g e
Model
NSC0500-110/1
NSC1000-230/1
NSC1000-LT-230/1
NSC2000-230/1
NSC2000-LT-230/1
Voltage
110 VAC, SINGLE
PHASE, 60 Hz
230VAC, SINGLE PHASE, 60 Hz
Compressor Power
½ HP
1 HP
2 HP
Cooling Capacity (BTU/hr)
6,000 BTU/hr
90F ambient
65F Fluid Temp
12,000 BTU/hr
90F Ambient
65F Fluid Temp
12,000 BTU/hr
90F Ambient
40F Fluid Temp
24,000 BTU/hr
90F Ambient
65F Fluid Temp
24,000 BTU/hr
90F Ambient
40F Fluid Temp
Fluid Temp Range
40F – 80F
40F – 80F
10F – 60F
40F – 80F
10F – 60F
Refrigerant
R-134a
R-134a
R-404a
R-134a
R-404a
Metering Device
TXV
Pump Power
1/3 HP
3/4 HP
Pump Specs
4 GPM up to 50 PSI, Fixed Displacement
10GPM @ 28 PSI (Centrifugal)
Glycol %
70/30 (Water/Glycol)
70/30 (Water/Glycol)
50/50 (Water/Glycol)
70/30 (Water/Glycol)
50/50 (Water/Glycol)
Acceptable Fluids
Ethylene Glycol or Propylene Glycol*
North Slope Chillers recommends using distilled water to maximize life and performance of chiller
Consult North Slope Chillers prior to using other fluids in the chiller
Tank Capacity
3.5 Gallons
12 Gallons
Inlet and Outlet
1/2” NPT
3/4” NPT
Dry Weight (lbs)
150 lbs
260 lbs
390 lbs
Dimensions
28¼"L x 22½"W x
32½"H
34½"L x 28¼"W x 39"H
34¾"L x 43¼"W x 40"H
Specification sheet
North Slope Chillers tests every chiller on site prior to shipping. During testing North Slope Chillers uses a water/glycol mix to test their chillers. Since not all glycols are compatible with each other and vary by manufacture each chiller should be flushed with water for 10 minutes prior to use.
*The mix of Glycol to Water should be proportional to the desired freeze point. Always select a Glycol/Water mix that will prevent freezing at 25F below your set point. This will prevent freezing from occurring in the heat exchanger and prevent damaging the system. For example if your setpoint is 10F you should select a glycol percentage that would prevent freezing at -15F.
www.northslopechillers.com | (866) 826-2993 | 3130 S 1030 W, Suite 1 | Salt Lake City, UT 84119
Revised: 05/31/2018
Loading...
+ 7 hidden pages