Northern Lights M944W User Manual

M944W
Soundshield Assembly Instruc
tion
s
Corporate Headquarters 4420 14th Avenue N.W. Seattle, WA 98107 Tel: (206) 789-3880 Toll Free: (800) 762-0165 Fax: (206) 782-5455
Alaska Branch Offi ce 1200 West Int’l Airport Road P.O. Box 190208 Anchorage, AK 99519 Tel: (907) 562-2222 Fax: (907) 563-1921
www.northern-lights.com
Southeastern U.S.A. 1415 S.W. 6th Court Pompano Beach, FL 33069 Tel: (954) 946-7601 Fax: (954) 946-7409
East Coast Branch Northern Lights Industrial Park 8 Connector Road Andover, MA 01810 Tel: (978) 475-7400 Fax: (978) 475-7745
L695
M944W Soundshield
ITEM # DESCRIPTION ADE P/N QTY NOTES
1. Base board 05-71201 1
2. Extrusion, vertical 05-75423 4
3. Extrusion, horizontal, sides 05-75424 2
4. Extrusion, horizontal, ends 05-75426 2
5. Center post, top 05-75428 1
6. Center post, vertical 05-75427 2
7. Corner casting 05-70001 4
8. Bolting assembly 00-75714 22
9. Tie bracket 23-78701 2
10. Rear panel assembly 05-71222 1
11. Front panel assembly 05-71218 1
12. LH side panel forward assembly 05-71209 1 with vent box
13. LH side panel aft assembly 05-75408 1
14. RH side panel forward assembly 05-71207 1 no vent box
15. RH side panel aft assembly 05-75411 1
16. Top panel forward assembly 05-71217 1
17. Top panel aft assembly 05-75403 1
18. Penetration panel assembly 39-78008 1
19. Panel retainer bracket, 30R 23-70036 6
20. #10 screw s/s x 5/8” long 12-72002 12
21. Toe bracket, 30R 23-70038 4
22. Hex nut, nylock 1/4-20 14-00112 10
Specifi cations
Enclosure:
Length (OA) 60.50 in (1536.7 mm)
Width 30.80 in (782.3 mm)
Height 32.10 in (815 mm)
Base:
Length 61.0 in (1549.4 mm)
Width 31.3 in (795 mm)
Height 0.75 in (19.05 mm)
Assembled Height:
32.85 in (834.4 mm)
Assembled Weight (est):
170 lbs (77 kg)
L695 10/06
1
1
Prior to assembly, inspect all of the components for damage, and report any damage to the shipping company. Check the packing list to be sure all parts have been included in the package.
2
3
Select a mounting location in accordance with the guidelines in the IM1000 Instal­lation Manual (supplied with the generator set). The generator set must typically be mounted on a rigid, fl at surface above a strong structure, such as the vessel’s stringers, to minimize vibration transference to the hull. This is particularly important when em­ploying a sound shield, as the baseboard is a non-structural material and must be fully supported to minimize fl ex.
Note that the generator set is designed for single side service. When viewed from the rear, the left hand side is the service side and should be exposed for easy access for maintenance.
Install the base board (Item 1) in the vessel in as near a level attitude as possible.
Observe the arrow symbol on the board’s topside surface; this indicates the top and forward end orientation of the generator set/sound shield. Ensure that this arrow is correctly positioned or the unit will not mount correctly within the sound shield. Install toe bracket (item 21) to each corner of the base board to the pre-drilled holes. Use screws (item 20) to secure to base board. See fi gure 1.
4
Use the larger thu-holes near the center of the board as a template to drill your base mounting bolt holes into your fl oor or deck.
Place the generator set onto the baseboard, lining up the thru-holes with the mount­ing holes in the genset base frame and secure the set to the base.
2
L695 10/06