Northern Lights M753, M773L User Manual

Northern Lights M753, M773L User Manual

M753 / M773L

Soundshield Assembly Instructions

Corporate Headquarters

Alaska Branch Office

Southeastern U.S.A.

East Coast Branch

4420 14th Avenue N.W.

1200 West Int’l Airport Road

1415 S.W. 6th Court

Northern Lights Industrial Park

Seattle, WA 98107

P.O. Box 190208

Pompano Beach, FL 33069

8 Connector Road

Tel: (206)

789-3880

Anchorage, AK 99519

Tel: (954)

946-7601

Andover, MA 01810

Fax: (206)

782-5455

Tel: (907)

562-2222

Fax: (954)

946-7409

Tel: (978)

475-7400

 

 

Fax: (907)

563-1921

 

 

Fax: (978)

475-7745

www.northern-lights.com

L613 02/05

M753K/M773LK Soundshield

ITEM #

DESCRIPTION

ADE P/N

QTY

NOTES

 

 

 

 

 

1.

Base board

05-78609

1

 

 

 

 

 

 

2.

Extrusion, vertical

05-78611

4

 

 

 

 

 

 

3.

Extrusion, horizontal, sides

05-78612

2

 

 

 

 

 

 

4.

Extrusion, horizontal, ends

05-78613

2

 

 

 

 

 

 

5.

Corner casting

05-70001

4

 

 

 

 

 

 

6.

Bolting assembly

00-75714

20

 

 

 

 

 

 

7.

Rear panel assembly

05-78606

1

 

 

 

 

 

 

8.

Front panel assembly

05-78603

1

 

 

 

 

 

 

9.

LH side panel assembly

05-78607

1

w/vent box

 

 

 

 

 

10.

RH side panel assembly

05-78604

1

no vent box

 

 

 

 

 

11.

Top panel assembly

05-78602

1

 

 

 

 

 

 

12.

Penetration panel assembly

39-78008

1

 

 

 

 

 

 

13.

Panel retainer bracket, 30R

23-70036

6

 

 

 

 

 

 

14.

#10 screw s/s x 5/8” long

12-72002

8

 

 

 

 

 

 

15.

Toe bracket, 30R

23-70038

4

 

 

 

 

 

 

16.

Hex nut, nylock 1/4-20

14-00112

6

 

 

 

 

 

 

17.

1” 90 Degree Elbow

21-22002

1

 

 

 

 

 

Specifications

 

 

 

 

 

 

 

 

Enclosure:

 

 

 

 

 

 

 

 

 

 

Length (OA)

38.82 in (986 mm)

 

 

 

Width

25.16 in (639 mm)

 

 

 

Height

24.60 in (624 mm)

 

 

 

 

 

 

 

Base:

 

 

 

 

 

 

 

 

 

Length

39.32 in (998.7 mm)

 

 

Width

25.66 in (652 mm)

 

 

 

Height

0.75 in (19.05 mm)

 

Assembled Height:

 

 

 

25.32 in (643 mm)

Assembled Weight (est):

92.5 lbs (42.0 kg)

L613 02/05 1

1

2

Prior to assembly, inspect all components for damage. Report any damage to the shipping company. Check the packing list to be sure all parts are included.

Select a mounting location in accordance with the guidelines in the IM1000 Installation Manual (supplied with the generator set). The generator set must typically be mounted on a rigid, flat surface above a strong structure, such as the vessel’s stringers, to minimize vibration transference to the hull. CAUTION: THE BASEBOARD

IS A NON-STRUCTURAL MATERIAL AND MUST BE FULLY SUPPORTED TO MINIMIZE FLEX.

Note that the generator set is designed for single side service. When viewed from

3

Install the base board (item 1) in the vessel in as near a level attitude as possible. Observe the arrow symbol on the board’s topside surface. This indicates the top and forward end orientation of the genset / soundshield. Make sure arrow is correctly positioned or the unit will not mount correctly within the shield.

Install toe bracket (item 15) to each corner of the base board with screws (item 14) into pre-drilled holes. See figure 1.

Note that there are pre-drilled “through” holes on each side of the baseboard. Use these holes as guides to drill into the supporting substructure for through-bolting.

4

Snorkel hose on M773LK

Place the generator set onto the baseboard, lining up the thru-holes with the mounting holes in the genset base frame. Use 3/8” or 9 mm bolts of appropriate length to secure the genset and baseboard to the underlying structure.

2