Table of contents ........................................................................................................................................................... 3
5. IC Statement.......................................................................................................................................................... 6
6.1. Activation Of The Watch .............................................................................................................................. 7
6.2. Time Display ................................................................................................................................................. 7
7. Setting The Time ................................................................................................................................................... 8
7.1. Setting The Minutes And Hour Time ........................................................................................................... 8
8.2. Time In Alarm Mode ..................................................................................................................................... 9
9. TWA and Exposed Duration ................................................................................................................................ 10
9.1. TWA Display ................................................................................................................................................ 10
9.2. Maximum Exposition Display ................................................................................................................... 10
10. EOL (EOL=End Of Life) ........................................................................................................................................ 11
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
1. Introduction
The NORTH EAGLES gas detecting watch “Eagle 1” is a single gas detection instrument manufactured by
NORTH EAGLES in Switzerland. The watch permanently measures the concentration of H2s gas in the
ambient air and triggers an alarm once the pre-set gas levels on the watch are exceeded.
It is the wearer’s responsibility to properly react to this alarm.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
2. Safety Warning To Read Before Any Operating Of The Watch
1. Never replace the sensor, the battery or any other components by any person other than certified
North Eagles technicians.
2. Never change the battery in a ATEX zone.
3. Regularly test the reaction of the watch by exposing the watch to a gas concentration superior to the
low gas alarm setting.
4. When the watch is in « sleep » mode, it will not detect any gas level.
3. Security Warning To Read Before Any Operating Of The Watch
1. This watch is a gas detecting and alarm system instrument and not a measuring instrument.
2. The watch is water resistant and water splash resistant. It is strongly advised not to immerse the
watch in water, wear in the shower, wear for swimming or diving. Its functioning could be seriously
altered.
3. Verify that the sensor caption grille is free from dust, oil splashes or any other materials. Always make
sure the sensor grille is never obstructed.
4. Always use a clean and humid cloth to clean the exterior of the watch.
4. FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: The user is cautioned that changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets
the FCC RF exposure guidelines. This equipment has very low levels of RF energy that are deemed to comply
without testing of specific absorption ration.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
AGENT & IMPORTER FOR USA:
CH MARKETING LLC
P.O.Box 170
Peapack – NJ 07977
USA
Phone: 201 924 02 66
5. IC Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation
of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
This equipment complies with Canada radiation exposure limits set forth for uncontrolled
environments. This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
6. Factory Settings
Both hands and the disc are set at the factory. The day time is set to Swiss time (GMT+1).
The watch is delivered in SLEEP mode, the gas sensor is not activated, the hands a set at 9 0’clock and the
disc is set on SENSOR
6.1. Activation Of The Watch
The watch is delivered in SLEEP mode and can only be activated via the application (Cf “User’s manual
for the application”), or just follow the instructions on the application.
The gas sensor is activated, and the watch moves to HOUR mode
6.2. Time Display
When the watch is in « TIME » (normal mode of the watch), the hands indicate the time of day, the disc
shows » DETECT », to indicate that it is in detection mode
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
7. Setting The Time
7.1. Setting The Minutes And Hour Time
Using the TIME mode, press simultaneously both pushers until you hear a beep.
This beep sound indicates that the watch is in hours SETTING and the disc indicates DETECT
Press the EXP pusher to increment hours.
Press the EXP pusher to decrement hours.
To change minutes hours, quickly press both pushers simultaneously.
To revert to TIME mode, (day-time display), use either of the following commands:
1- By waiting 30 seconds, without touching the watch, it will revert automatically to hour mode.
2- Press both pushers simultaneously for more than a second
The return in mode TIME will be indicated by a double beep sound
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
8. Alarm
The watch is continuously measuring the presence of gas in the ambient air.
In case of gas detection, the watch automatically reverts to code «ALARM
Once gas is no longer detected, the watch reverts to TIME mode
8.1. Alarm Mode
In ALARM mode, the disc indicates DETECT . The hour hand indicates the actual gas detected on the gas
detection display scale. The minute hand indicates the maximum gas concentration reached.
In case of alarm, the red LED will flash, the vibrator will vibrate and a loud BIP will sound.
8.2. Time In Alarm Mode
During ALARM mode, it is possible to check the time of day by pushing the EOL pusher.
The watch will show the time and will automatically revert in ALARM AFTER 10 SECONDS.
.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
9. TWA and Exposed Duration
When the watch is exposed to gas, both following values can be read:
- TWA (Time Weighted Average), is the average time of exposure to gas on 8 hours.
- Maximum exposition, this is the maximum level of gas concentration measured.
It is possible to view the TWA and Maximum exposition when the watch is not exposed to gas.
9.1. TWA Display
From the «TIME » mode, press the pusher EXP to display the TWA. The disc will indicate the TWA.
The minutes hand will move to the 9 o’clock position and the hour hand.
To re-instate the TWA, press both pushers simultaneously during 3 seconds.
From the TWA mode, the watch will return automatically to mode «TIME » after 10 seconds
9.2. Maximum Exposition Display
From the TWA mode, press the EXP pusher to display the maximum exposition. The disc will indicate MAX
EXP. The minute hand will move to 9 o’clock and the hour hand will the maximum exposition on the gas
concentration scale.
Simultaneously press both pushers during 3 seconds to re-initialize the Maximum exposition.
From the « EXPOSITION » mode, the watch will revert back to mode « TIME » after 10 seconds.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
10. EOL (EOL=End Of Life)
It is possible to read the following two values:
- EOL SENSOR, indicator of sensor caption (time before re-calibrating).
- EOL BATTERY, battery end of life indicator.
The sensor must be re-calibrated frequently. This period of time is configurable only with the technical
application (the default value is 2 years)
Checking EOL SENSOR and EOL Battery is only possible when the watch is not exposed to gas.
10.1. EOL Sensor Display
From the TIME mode, press the EOL pusher to display the EOL of the SENSOR. The disc
indicates SENSOR.
The minutes hand will align to 9 o’clock, and the hour hand will indicate the % of the time before recalibrating
From the EOL SENSOR mode, the watch will automatically return into HEURE (hour) mode, after 10
seconds.
10.2. Re-initialisation Of The Deadline For Recalibrating The Sensor
From the EOL SENSOR mode, press both pushers simultaneously for 3 seconds. A beep sound indicates
that the re-calibration is set back to zero.
10.3. EOL Battery Display
From the EOL SENSOR mode, press the EOL pusher to display the EOL BATTERY. Indication on disc is:
BATT.
The minute hand will align at 9 o’clock and the hour hand indicates the % of the remaining charge of the
battery.
From the EOL BATTERY mode, the watch will return automatically the TIME mode after 10 seconds.
10.4. Reset Of Battery EOL
From the EOL BATTERY mode, press simultaneously both pushers during 10 seconds.
A beep will indicate that the EOL battery is reset to zero.
10.5. Recalibration Time Expired
When the sensor must be recalibrated (< 5% of the time), the watch does not not display the time
anymore and the disc will display SENSOR and the hour hand will show the lowest point on the scale
marked REPLACE on the dial.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
10.6. Battery Discharged
When the battery is discharged (<5%) the watch does no longer display the time of day, and the disc will
display BATT and the hour hand will indicate the lowest point on the scale marked REPLACE on the dial.
.
10.7. Priority Of Automatic Alarms
There are 3 automatic alarms displayed as follows:
1- Gas alarm detected
2- Battery discharged
3- Re-calibrate sensor
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
11. Calibration
When the watch is subjected to a significant shock, it is possible that the disc or the hands lose their
alignment.
Also, during a battery change, it is necessary to re-calibrate the disc and hands.
11.1. Calibration Of The Hands And Disc
From the «TIME » mode, press simultaneously both pushers. A first beep indicates that the watch
switches to HOUR SETTING mode.
Keep pressing both pushers. After 3 seconds, a second beep indicates that the watch switches
to CALIBRATION. The disc indicates DETECT, and the hands move on top of each others at
12 o’clock.
If the disc is not exactly on DETECT or if the hands are not exactly on 12 0’clock, a calibration is
necessary.
Press pusher EXP to move the hour hand by one step clock wise.
Press the pusher EOL to turn the hour hand by one step counter clock wise.
Align the hour hand precisely at 12 o’clock.
Press simultaneously both pushers to calibrate the minute hand.
Press pusher EXP to move the minute hand by one step clock wise.
Press the EOL pusher to move the minute hand of a step counter clock wise.
Align the minutes hand precisely at 12 o’clock.
Press both pushers simultaneously to calibrate the disc.
Press EXP pusher to move disc by a step clock wise.
Press the EOL pusher to move disc of a step anti-clock wise.
Align disc precisely on the red DETECT window.
Press simultaneously both pushers to finish calibration.
With no action, the watch automatically resets to
«TIME » mode after 30 seconds.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
12. Sleep mode
The sleep mode purpose is to avoid battery discharge.
When in this mode, the gas detection is disactivated. The hands are resting at 9 o’clock and the disc is
resting on SENSOR. The watch will keep the time but will not display it anymore
The sleep mode can be only activated by an authorized service centre.
When changing battery, the watch automatically reverts to SLEEP.
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
13. Specifications
13.1. Norms and certifications
The NORTH EALGES gas detector watch meets and complies with the following norms :
EN 60079-0 :2012+A11 :2013 IEC 60079-0 Ed. 6.0
EN 60079-11 :2012 IEC 60079-11 Ed. 6.0
UL 61010-1 :2012/CSA C22.2No. 61010-1-12 UL 60079-0 Part0 : 6
UL 60079-11 Part 11 : 6
CAN/CSA-C22.2 No. 60079-11 :14 Part :11
The watch is certified as follow :
ATEX / IECEx UL/CSA
II 1G Ex ia IIC T4 G EII4644
SEV 17 ATEX 0148 X Electrical safety
IECEx SEV 17.00 14X Ex ia IIC T4 Ga
C E 1258 Class I Zone 0 AEx ia IIC T4 Ga
Cl Div 1 Gp A, B, C, D T4
The watch can be used indoor and outdoor.
The watch can be used in wet locations where water and another conductive liquid may be present
and is likely to cause reduced human body impedance due to wetting of the contact between the
human body and the equipment or wetting of the contact between the human body and the
environment.
The watch can be used at an altitude up to 2’000 meters / 6’600 ft
The watch can be used at a relative humidity of 5% to 95% (non condensing)
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
th
edition
13.5. Dimensions and mass of the product
Case dimensions: 62 x 41 x 25 mm / 2.44 x 1.61 x 0.98 in
Strap (long part) dimensions: 136 x 26 x 4 mm / 5.35 x 1.02 x 0.15 in
Strap (short part) dimensions: 87 x 26 x 4 mm / 3.42 x 1.02 x 0.15 in
Total mass: 115 gr / 4,05 oz
13.6. Factory Provided Battery
Battery Li-SOCl2 replaceable.
Battery brand:
energy density ½ AA-size bobbin cell »
SAFT reference LS 14250, 3.6 V « Primary lithium-thionyl chloride (Li-SOCl2) High
13.7. Changing The Battery
- When changing the battery, only use the battery described under point 11.3. Using a different
battery could significantly affect the intrinsic safety of the watch and its functioning would
not be guaranteed any longer.
- Never change the battery in a dangerous or explosive environment.
- Never change battery yourself. Bring the watch to your « Security and Health
or to an approved and official service centre in your area. (cf www.northeagles.ch)
- To change battery, unscrew the 5 screws and remove the back of the case, remove the used
battery and replace with new battery, checking the correct poles + and – as printed in the
battery housing. Replace back cover of watch case and screw back the 5 screws.
- After changing the battery, the battery duration indication has to be reset to zero using the
technical application.
- After changing the battery, the watch has to be completely re-calibrated.
»department
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.