Nortel Networks 2600, 4000, 4500, Centillion 1600, 2500 User Manual

...
Part No. 302283-E Rev 00 August 2001
600 Technology Park Drive Billerica, MA 01821-4130

Installing Hardware Options for the Contivity VPN Switch

2
Copyright © 2001 Nortel Networks
All rights reserved. August 2001. The information in this document is subject to change without notice. The statements, configurations, technical data, and
recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks Inc.
The software described in this document is furnished under a license agreement and may be used only in accordance with the terms of that license. The software license agreement is included in this document.
Trademarks
Nortel Networks, the Nortel Networks logo, the Globemark, Unified Networks, and Contivity are trademarks of Nortel Networks.
Microsoft, Windows, and Windows NT and MS-DOS are trademarks of Microsoft Corporation. Adobe and Acrobat Reader are trademarks of Adobe Systems Incorporated.
Restricted rights legend
Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.
Notwithstanding any other license agreement that may pertain to, or accompany the delivery of, this computer software, the rights of the United States Government regarding its use, reproduction, and disclosure are as set forth in the Commercial Computer Software-Restricted Rights clause at FAR 52.227-19.
Statement of conditions
In the interest of improving internal design, operational function, and/or reliability, Nortel Networks Inc. reserves the right to make changes to the products described in this document without notice.
Nortel Networks Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
Portions of the code in this software product may be Copyright © 1988, Regents of the University of California. All rights reserved. Redistribution and use in source and binary forms of such portions are permitted, provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California, Berkeley. The name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission.
SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
In addition, the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure (that may incorporate by reference certain limitations and notices imposed by third parties).
USA requirements only
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense.
European requirements only
EN 55 022 statement (Class A)
This is to certify that the Nortel Networks Contivity VPN Switch is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
War ni ng : This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take appropriate measures.
Achtung: Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Attention: Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à lutilisateur de prendre les mesures spécifiques appropriées.
To maintain compliance with FCC radio frequency emission limits, shielded cables are required to connect equipment to other Class A certified devices and the use of quadshield, RG-6/U type CATV cable is required for connection to the CATV system. Any changes or modifications may void the users authorization to operate this equipment.
3
EN 55 022 statement (Class B)
This is to certify that the Nortel Networks Contivity 1600 and 2600 are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class B (CISPR 22).
Compliance is dependent upon the use of shielded Nortel Networks Contivity 1600 or 2600.
EC Declaration of Conformity
Tthese products conform to the provisions of the R&TTE Directive 1999/5/EC.
Installing Hardware Options for the Contivity VPN Switch
4
Japan/Nippon requirements only
Voluntary Control Council for Interference (VCCI) statement (Class A)
Voluntary Control Council for Interference (VCCI) statement (Class B Contivity 1600 and 2600)
Taiwan requirements
Bureau of Standards, Metrology and Inspection (BSMI) statement
Canada requirements only
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (Contivity VPN Switch) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (Contivity VPN Switch) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (Contivity 1600 and Contivity 2600) does not exceed the Class B limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications (Classe B)
Cet appareil numérique (Contivity 1600 and Contivity 2600) respecte les limites de bruits radioélectriques visant les appareils numériques de classe B prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada.
Canada CS-03 rules and regulations
Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the users satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent the degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
Notice: For equipment using loopstart lines, please note that the Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. The REN is located on the FCC Rules Part 68 label located on the bracket of the module, or on the back of the unit.
5
Canada CS-03 -- règles et règlements
Avis: L'étiquette d'Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d'exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n'assure toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur.
Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée de raccordement. L'abonné ne doit pas oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus n'empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel homologué doivent être coordonnées par un représentant désigné par le fournisseur. L'entreprise de télécommunications peut demander à l'utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l'utilisateur ou à cause de mauvais fonctionnement.
Installing Hardware Options for the Contivity VPN Switch
6
Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de la source d'énergie électrique, des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales.
Avertissement: L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service d'inspection des installations électriques, ou à un électricien, selon le cas.
Avis: Veuillez prendre note que pour tout appareillage supportant des lignes de type loopstart, l'indice d'équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d'une interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme d'indices d'équivalence de la sonnerie de tous les dispositifs n'excède pas 5. Le REN figure sur l’étiquette “FCC Rules Part 68 située sur le support du module ou à l’arrière de l’unité.
FCC Part 68 compliance statement
This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68. Please note the following:
1. You are required to request service from the telephone company before you connect the unit to a network. When you request service, you must provide the telephone company with the following data:
When you request T1 Service, you must provide the telephone company with
The Facility Interface Code
Provide the telephone company with all the codes below:
04DU9-BN (1.544 MB, D4 framing format)04DU9-DN (1.544 MB, D4 framing format with B8ZF coding)04DU9-1KN (1.544 MB, ESF framing format)04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding)04DU9-1ZN (1.544 MB, ANSI ESF and ZBTSI without line power)
The telephone company will select the code it has available.
The Service Order Code(s) (SOC): 6.0Y The required Universal Service Order Code (USOC) jack: RJ48C
When you request ISDN “U” Interface Service, you must provide the telephone company with
The Facility Interface Code: 02IS5 The Service Order Code(s) (SOC): 6.0F The required Universal Service Order Code (USOC) jack: RJ49C
When you request ISDN “S/T” Interface Service, you must provide the telephone company with
The Service Order Code(s) (SOC): 6.0P The make, model number, and FCC Registration number of the NT1
Note:
ISDN S/T cannot be directly connected to the network.
When you request Primary Rate ISDN Service, you must provide the telephone company with
The Facility Interface Code: 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding) The Service Order Code(s) (SOC): 6.0Y The required Universal Service Order Code (USOC) jack: RJ48C
2. Your telephone company may make changes to its facilities, equipment, operations, or procedures that could affect the proper functioning of your equipment. The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service.
3. If the unit causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they will notify you in advance, but if advance notice is not practical, you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC.
4. If you experience trouble with the unit, please contact the Nortel Networks Technical Solutions Center in your area for service or repairs. Repairs should be performed only by service personnel authorized by Nortel Networks.
North America (800) 4NORTEL or (800) 466-7835 EMEA (33) (4) 92-966-968 Asia Pacific (61) (2) 9927-8800 China (800) 810-5000
5. You are required to notify the telephone company when you disconnect the unit from the network.
Nortel Networks Inc. software license agreement
NOTICE: Please carefully read this license agreement before copying or using the accompanying software or installing the hardware unit with pre-enabled software (each of which is referred to as “Software” in this Agreement). BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT. THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE. If you do not accept these terms and conditions, return the product, unused and in the original shipping container, within 30 days of purchase to obtain a credit for the full purchase price.
1. License grant. Nortel Networks Inc. (Nortel Networks) grants the end user of the Software (“Licensee) a personal,
nonexclusive, nontransferable license: a) to use the Software either on a single computer or, if applicable, on a single authorized device identified by host ID, for which it was originally acquired; b) to copy the Software solely for backup purposes in support of authorized use of the Software; and c) to use and copy the associated user manual solely in support of authorized use of the Software by Licensee. This license applies to the Software only and does not extend to Nortel Networks Agent software or other Nortel Networks software products. Nortel Networks Agent software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel Networks Inc. Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software.
2. Restrictions on use; reservation of rights. The Software and user manuals are protected under copyright laws.
Nortel Networks and/or its licensors retain all title and ownership in both the Software and user manuals, including any revisions made by Nortel Networks or its licensors. The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals. Licensee may not modify, translate, decompile, disassemble, use for any competitive analysis, reverse engineer, distribute, or create derivative works from the Software or user manuals or any copy, in whole or in part. Except as expressly provided in this Agreement, Licensee may not copy or transfer the Software or user manuals, in whole or in part. The Software and user manuals embody Nortel Networks and its licensors confidential and proprietary intellectual property. Licensee shall not sublicense, assign, or otherwise disclose to any third party the Software, or any information about the operation, design, performance, or implementation of the Software and user manuals that is confidential to Nortel Networks and its licensors; however, Licensee may grant permission to its consultants, subcontractors, and agents to use the Software at Licensee’s facility, provided they have agreed to use the Software only in accordance with the terms of this license.
3. Limited warranty. Nortel Networks warrants each item of Software, as delivered by Nortel Networks and properly
installed and operated on Nortel Networks hardware or other equipment it is originally licensed for, to function substantially as described in its accompanying user manual during its warranty period, which begins on the date Software is first shipped to Licensee. If any item of Software fails to so function during its warranty period, as the sole
7
Installing Hardware Options for the Contivity VPN Switch
8
remedy Nortel Networks will at its discretion provide a suitable fix, patch, or workaround for the problem that may be included in a future Software release. Nortel Networks further warrants to Licensee that the media on which the Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days from the date Software is first shipped to Licensee. Nortel Networks will replace defective media at no charge if it is returned to Nortel Networks during the warranty period along with proof of the date of shipment. This warranty does not apply if the media has been damaged as a result of accident, misuse, or abuse. The Licensee assumes all responsibility for selection of the Software to achieve Licensee’s intended results and for the installation, use, and results obtained from the Software. Nortel Networks does not warrant a) that the functions contained in the software will meet the Licensee’s requirements, b) that the Software will operate in the hardware or software combinations that the Licensee may select, c) that the operation of the Software will be uninterrupted or error free, or d) that all defects in the operation of the Software will be corrected. Nortel Networks is not obligated to remedy any Software defect that cannot be reproduced with the latest Software release. These warranties do not apply to the Software if it has been (i) altered, except by Nortel Networks or in accordance with its instructions; (ii) used in conjunction with another vendor’s product, resulting in the defect; or (iii) damaged by improper environment, abuse, misuse, accident, or negligence. THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Licensee is responsible for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files, data, or programs.
4. Limitation of liability. IN NO EVENT WILL NORTEL NETWORKS OR ITS LICENSORS BE LIABLE FOR
ANY COST OF SUBSTITUTE PROCUREMENT; SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES; OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE, EVEN IF NORTEL NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL THE LIABILITY OF NORTEL NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT EXCEED THE PRICE PAID TO NORTEL NETWORKS FOR THE SOFTWARE LICENSE.
5. Government licensees. This provision applies to all Software and documentation acquired directly or indirectly by or
on behalf of the United States Government. The Software and documentation are commercial products, licensed on the open market at market prices, and were developed entirely at private expense and without the use of any U.S. Government funds. The license to the U.S. Government is granted only with restricted rights, and use, duplication, or disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial Computer Software––Restricted Rights clause of FAR 52.227-19 and the limitations set out in this license for civilian agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS
252.227-7013, for agencies of the Department of Defense or their successors, whichever is applicable.
6. Use of software in the European Community. This provision applies to all Software acquired for use within the
European Community. If Licensee uses the Software within a country in the European Community, the Software Directive enacted by the Council of European Communities Directive dated 14 May, 1991, will apply to the examination of the Software to facilitate interoperability. Licensee agrees to notify Nortel Networks of any such intended examination of the Software and may procure support and assistance from Nortel Networks.
7. Term and termination. This license is effective until terminated; however, all of the restrictions with respect to
Nortel Networks copyright in the Software and user manuals will cease being effective at the date of expiration of the Nortel Networks copyright; those restrictions relating to use and disclosure of Nortel Networks confidential information shall continue in effect. Licensee may terminate this license at any time. The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license. Upon termination for any reason, Licensee will immediately destroy or return to Nortel Networks the Software, user manuals, and all copies. Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license.
8. Export and re-export. Licensee agrees not to export, directly or indirectly, the Software or related technical data or
information without first obtaining any required export licenses or other governmental approvals. Without limiting the foregoing, Licensee, on behalf of itself and its subsidiaries and affiliates, agrees that it will not, without first obtaining all

Contents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Text conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hard-copy technical manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
How to get help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Chapter 1
Contivity 4600 Option Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Opening the Contivity 4600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Contivity 4600 system board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Installing Contivity 4600 LAN/WAN and hardware accelerator cards . . . . . . . . . . . . . 23
Installing Contivity 4600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Replacing a Contivity 4600 power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Replacing a Contivity 4600 hard disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9
Chapter 2
Contivity 4500 Option Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Opening the Contivity 4500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Removing the Contivity 4500 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Contivity 4500 system board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Installing Contivity 4500 LAN/WAN and hardware accelerator option cards . . . . . . . . 36
Installing Contivity 4500 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Replacing a Contivity 4500 power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Replacing a Contivity 4500 hard disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Chapter 3
Contivity 2500/2000/4000 Option Installation . . . . . . . . . . . . . . . . . . . . . . . 43
Opening the Contivity 2500/2000/4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Removing the Contivity 2500/2000/4000 front bezel . . . . . . . . . . . . . . . . . . . . . . . 43
Removing the Contivity 2500/2000/4000 top cover . . . . . . . . . . . . . . . . . . . . . . . . 45
Contivity 2500/2000/4000 system board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Installing Hardware Options for the Contivity VPN Switch
10
Installing Contivity 2500/2000/4000 LAN/WAN option cards . . . . . . . . . . . . . . . . . . . . 48
Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Replacing a Contivity 4000 power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Replacing a Contivity 4000 disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Memory option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Chapter 4
Contivity 2600 Option Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Opening the Contivity 2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Removing the Contivity 2600 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Removing the Contivity 2600 top cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Contivity 2600 system board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Installing LAN/WAN and hardware accelerator option cards . . . . . . . . . . . . . . . . . . . . 62
Installing Contivity 2600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Memory option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Chapter 5
Contivity 1600 Option Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Opening the Contivity 1600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Removing the Contivity 1600 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Removing the Contivity 1600 top cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Contivity 1600 system board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Installing Contivity 1600 option cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Installing Contivity 1600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Memory option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Chapter 6
Contivity 600 Option Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Opening the Contivity 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Contivity 600 system board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Installing Contivity 600 option cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Memory option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Figures

Figure 1 Removing the Contivity 4600 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2 Contivity 4600 front components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 3 Sample Contivity 4600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 4 Installing Contivity 4600 LAN/WAN and hardware accelerator cards . . . . 23
Figure 5 Installing Contivity 4600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 6 Removing a Contivity 4600 power supply . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 7 Removing a Contivity 4600 hard disk drive . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 8 Removing the Contivity 4500 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 9 Contivity 4500 front components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 10 Sample Contivity 4500 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 11 Installing 4500 LAN/WAN and hardware accelerator option cards . . . . . . 37
Figure 12 Installing Contivity 4500 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 13 Removing a Contivity 4500 power supply . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 14 Removing a Contivity 4500 hard disk drive . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 15 Removing the Contivity 2500/2000/4000 front bezel . . . . . . . . . . . . . . . . 44
Figure 16 Removing the Contivity 2500/2000/4000 top cover . . . . . . . . . . . . . . . . . 45
Figure 17 Sample Contivity 2500/2000 system board . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 18 Sample Contivity 4000 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 19 Installing 2500/2000/4000 LAN/WAN option cards . . . . . . . . . . . . . . . . . . 48
Figure 20 Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 21 Removing a Contivity 4000 power supply . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 22 Removing a Contivity 4000 hard disk drive . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 23 Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 24 Removing the Contivity 2600 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 25 Removing the Contivity 2600 top cover . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 26 The Contivity 2600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 27 Installing LAN/WAN or hardware accelerator cards . . . . . . . . . . . . . . . . . 62
Figure 28 Installing Contivity 2600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 29 Removing the Contivity 1600 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . 68
11
Installing Hardware Options for the Contivity VPN Switch
12
Figure 30 Removing the Contivity 1600 power cord . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 31 Removing the Contivity 1600 top cover . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Figure 32 Contivity 1600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Figure 33 Removing the Contivity 1600 power cord . . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 34 Installing Contivity 1600 LAN/WAN option cards . . . . . . . . . . . . . . . . . . . 73
Figure 35 Installing Contivity 1600 option cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 36 Installing Contivity 1600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 37 Removing the bottom screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 38 Removing the system from the chassis . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Figure 39 Contivity 600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 40 Replacing the system into the chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Preface

13
This document describes how install or replace hardware components for models 4600, 4500, 4000, 2600, 2500, 2000, 1600, and 600 of the
Installing LAN and WAN option cards
Installing hardware accelerator PCI cards
Adding or replacing memory
Replacing a power supply (4600, 4500, and 4000 only)
Replacing a hard disk drive (4600, 4500, and 4000 only)
To install LAN, WAN, or hardware accelerator PCI cards and for system recovery operations, you must remove the front bezel, the top cover, and/or the rear I/O panel tray, depending on the type of Contivity product you are servicing. The procedures for each Contivity model are described in the following chapters.
Warning:
change existing hardware configurations.
components or assemblies, with the power connected, could cause severe injury.
Warning:
Manufacturing via your Customer Service Representative for repair.
not attempt to make any changes
individuals could be harmed, you could invalidate your warranty, or you could possibly cause irreparable damage to the equipment.
Only Nortel Networks trained service personnel should
Note that some models must be returned to Nortel Networks
Nortel Networks*
Contivity*
products. The options include:
to these models, because untrained
trained service personnel can
Improper handling of internal
Do
Installing Hardware Options for the Contivity VPN Switch
14 Preface
This guide refers to the Contivity 4600, 4500, 4000, 2600, 2000, 1600, and 600 as the switch. It assumes that you are familiar with Web browsers and their general operation.

Related publications

The following list shows the associated documentation that you will need to configure and manage the switch.
Contivity VPN Switch Release Notes provide the latest information, including known problems, workarounds, and special considerations.
Configuring the Contivity VPN Switch (included on the CD) provides complete detailson how to configure, monitor, and troubleshoot the switch.
Getting Started with the Contivity xxxx or Installing the Contivity xxxx (included on the CD) provides complete details to help you set up and get started using your switch.

Text conventions

This guide uses the following text conventions:
angle brackets (< >) Indicate that you choose the text to enter based on the
bold Courier text
description inside the brackets. Do not type the brackets when entering the command.
Example: If the command syntax is
ping <ip_address> ping 192.32.10.12
Indicates command names, options, and text that you need to enter.
Example: Use the Example: Enter
, you enter
dinfo
show ip
command.
{alerts|routes}
.
Preface 15
braces ({}) Indicate required elements in syntax descriptions where
there is more than one option. You must choose only one of the options. Do not type the braces when entering the command.
Example: If the command syntax is
show ip {alerts|routes} show ip alerts
or
show ip routes
, you must enter either
, but not both.
brackets ([ ]) Indicate optional elements in syntax descriptions. Do
not type the brackets when entering the command. Example: If the command syntax is
show ip interface [-alerts]
show ip interface
either
show ip interface -alerts
or
.
, you can enter
ellipsis points (. . . ) Indicate that you repeat the last element of the
command as needed. Example: If the command syntax is
ethernet/2/1 [<parameter> <value>]...
you enter
ethernet/2/1
and as many
,
parameter-value pairs as needed.
italic text Indicates new terms, book titles, and variables in
command syntax descriptions. Where a variable is two or more words, the words are connected by an underscore.
Example: If the command syntax is
show at <valid_route>, valid_route
is one
variable and you substitute one value for it.
plain Courier text
Indicates command syntax and system output, for example, prompts and system messages.
Example: Set Trap Monitor Filters
separator ( -> ) Shows menu paths.
Example: Protocols > IP identifies the IP option on the Protocols menu.
Installing Hardware Options for the Contivity VPN Switch
16 Preface

Acronyms

vertical line (
asterisk (*) Indicates a trademark. See the Title Page for trademark
This guide uses the following acronyms:
CSU/DSU Channel Service Unit/ Digital Service Unit
DIMM Dual inline memory module
DTE Data Terminal Equipment
ERC Express Routing Code
) Separates choices for command keywords and
|
arguments. Enter only one of the choices. Do not type the vertical line when entering the command.
Example: If the command syntax is
show ip {alerts|routes} show ip alerts or show ip routes
both.
information. Example: Contivity*
, you enter either
, but not
FTP File Transfer Protocol
HSSI high speed serial interface
HTTP HyperText Transfer Protocol
IP Internet Protocol
IPMI Intelligent Platform Management Interface
LAN Local area network
LED Light emitting diode
PCI Peripheral component interconnect
PDN Public data network
SCSI Small computer system interface
SNMP Simple Network Management Protocol
TCP Transmission Control Protocol
URL Uniform Resource Locator
VPN Virtual private network
WAN Wide area network

Hard-copy technical manuals

You can print selected technical manuals and release notes free, directly from the Internet. Go to the www.nortelnetworks.com/documentation URL. Find the product for which you need documentation. Then locate the specific category and model or version for your hardware or software product. Use Adobe* Acrobat Reader* to open the manuals and release notes, search for the sections you need, and print them on most standard printers. Go to Adobe Systems at the
www.adobe.com URL to download a free copy of the Adobe Acrobat Reader*.
You can purchase selected documentation sets, CDs, and technical publications through the Internet at the www1.fatbrain.com/documentation/nortel/ URL.
Preface 17

How to get help

If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance.
If you purchased a Nortel Networks service program, contact one of the following Nortel Networks Technical Solutions Centers:
Technical Solutions Center Telephone
Europe, Middle East, and Africa (33) (4) 92-966-968
North America (800) 2LANWAN or (800) 252-6926
Asia Pacific (61) (2) 9927-8800
China (800) 810-5000
Installing Hardware Options for the Contivity VPN Switch
18 Preface
An Express Routing Code (ERC) is available for many Nortel Networks products and services. When you use an ERC, your call is routed to a technical support person who specializes in supporting that product or service. To locate an ERC for your product or service, go to the www12.nortelnetworks.com/ URL and click Express Call Routing at the bottom of the page.
Chapter 1 Contivity 4600 Option Installation
This section describes how to install or replace hardware components for the Contivity 4600.
19
Caution:
for the switch to avoid damaging them.
Warning:
installing LAN and WAN cards or system memory.
Wear an antistatic band when handling electronic components
Turn off the switch and unplug both power cords before

Opening the Contivity 4600

To replace power supplies, replace hard disk drives, or access the diskette drive for system recovery operations, you must remove the switch’s front bezel.
Note:
chassis intrusion alarm on power only. This intrusion is reported to the system log file.
The first few times you remove the front bezel it might seem to resist removal. This is simply because the ball stud and sockets are new. After a few times, removal is easier. Remove the switch front bezel as follows:
Removing the front bezel on the Contivity 4600 activates the
1
Insert a flat-head screwdriver into the slots on the lower left and right sides of the chassis, and pry the bezel forward.
2
Slide your fingers between the front bezel and the switch.
3
Pull the bezel forward firmly, separating the ball studs on the bezel from the sockets on the chassis.
Installing Hardware Options for the Contivity VPN Switch
20 Chapter 1 Contivity 4600 Option Installation
Figure 1 shows you how to remove the front bezel from the Contivity 4600.
You do not need to turn off the switch to remove the front bezel when installing a power supply or hard disk drive.
Figure 1 Removing the Contivity 4600 front bezel
Using a phillips screwdriver, rotate screws a quarter turn anti-clockwise (top right and left corners), then separate ball stud on bezel from socket on chassis (middle of both sides and bottom right and left corners)
B o
o
t /
R
A
e
l
a
e
d r t
y
/ F
a i l
C
o
nti
v
i
t
y 4600
CS460005A
Chapter 1 Contivity 4600 Option Installation 21
Figure 2 shows the Contivity 4600 front components.
Figure 2 Contivity 4600 front components
Alert/Fail
Boot/Ready
Disk drives
Floppy drive
Power supplies
CS460006A
Installing Hardware Options for the Contivity VPN Switch
22 Chapter 1 Contivity 4600 Option Installation

Contivity 4600 system board layout

This section shows the Contivity 4600 system board.
Warning:
Only Nortel Networks trained service personnel should
change existing hardware configurations.
components or assemblies, with the power connected, could cause severe injury.
Figure 3
Memory Modules (DIMMs) and
Figure 3 Sample Contivity 4600 system board
shows a sample Contivity 4600 system board, including the Dual Inline
peripheral component interconnect (
1
2
PCI
3
slots
4
5
DIMM
slots
6
Improper handling of internal
PCI) slots.
CS460007A
Chapter 1 Contivity 4600 Option Installation 23

Installing Contivity 4600 LAN/WAN and hardware accelerator cards

This section describes how you install option cards in the switch option card slide-out tray. The following procedure is for Nortel Networks trained service personnel only.
1
Turn off the switch and unplug both power cords from the power source.
2
Unscrew the four slotted thumb-screws securing the slide-out tray. Pull out the tray by gripping it with the screws. It will only pull out halfway.
3
Remove the filler panel screw and pull out the slot filler panel.
4
Slide the option card into the intended slot. Make sure the card seats firmly and evenly in the card slot. If the card is not seated properly, it will not work. Populate the slots from Slot 1 to Slot 6 (top to bottom), in that order, as shown in Figure 4.
Figure 4 Installing Contivity 4600 LAN/WAN and hardware accelerator cards
CS460014A
5
Secure the option card in the tray with the slot filler panel screw.
6
Push in the tray by gripping it with the screws. Tighten the four slotted thumb-screws securing the slide-out tray.
Installing Hardware Options for the Contivity VPN Switch
24 Chapter 1 Contivity 4600 Option Installation
Plug in both power cords to the power source and turn on the switch.
7
Caution:
4600, because the slide-out tray is not fully supported once pulled out. You should support the back of the tray with your hand while inserting an option card.
Be careful when inserting option cards into the Contivity

Installing Contivity 4600 DIMMs

Figure 6
install a DIMM. Install a DIMM in the next available slot (for example, if the DIMM #1 slot is populated, then add the next DIMM to the DIMM #2 slot).
To install a DIMM in the Contivity 4600, follow these steps:
1
2
3
4
shows you how to unlock a DIMM in the Contivity 4600, and remove or
Turn off the switch and unplug both power cords from the power source.
Unscrew the four slotted thumb-screws securing the slide-out tray. Pull out the tray by gripping it with the screws. It will only pull out halfway.
Unscrew the slide-out tray at the back of the unit and pull it out using the thumb screws.
Remove the support bracket by loosening the two secured captive screws and the rear Phillips screw.
5
Press down the locking levers on both sides of the next available DIMM slot.
6
Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys, as shown in Figure 5.
Chapter 1 Contivity 4600 Option Installation 25
Figure 5 Installing Contivity 4600 DIMMs
Alignment Keys
1
2
2
3
4
Locking lever
7
Pull up the locking levers on both sides of the next available DIMM, and snap the DIMM into its socket.
8
Replace the support bracket by tightening the two secured captive screws and the rear Phillips screw.
9
Push in the slide-out tray and tighten the thumb-screws.

Replacing a Contivity 4600 power supply

To remove the power supply:
1
Remove the front bezel as shown in Figure 1.
2
Use a flat-head screwdriver to unscrew the top and bottom power supply screws, as shown in Figure 6.
CS460009A
Installing Hardware Options for the Contivity VPN Switch
26 Chapter 1 Contivity 4600 Option Installation
Figure 6 Removing a Contivity 4600 power supply
Boo
t/R
A
ea
lert/F
dy
ail
CS460010A
3
Grab the handle and pull the power supply firmly, until the device disengages. Be careful of the sharp sheet-metal edges.
4
Insert the new power supply. Make sure it seats firmly in its socket and is locked in. Be sure the green power LED on the front of the power supply is on.
5
Secure the power supply screws tightly with a screwdriver.
6
Replace the front bezel.
Loading...