Nortel BayStack 470-48T-PWR, Power Supply 15 Supplementary Manual

> BUSINESS MADE SIMPLE
Application Brief
Using the Nortel Redundant Power Supply 15
Features & Benefits
Provides Power Redundancy to Ethernet
Routing Switches 5510, 5520 and 5530, Business Policy Switch 2000, BayStack 380, Ethernet Switch 470 and 470-PWR,
as well as
Ethernet Services Unit 1400, 1450 and 1800 .
Compact packaging. Single chassis, 2U high for standard 19" rack, provides scalable, Redundant Power Supply for multiple devices.
Highly Efficient. Redundant Power Supply modules-available in 600 watt rating-provide redundant DC power to up to
twelve devices per chassis.
Flexible deployment. Redundant Power modules may be purchased separately and installed into the chassis as needed, while unit remains fully operational.
Protects mission-critical enterprise applications from interruption due to problems with either the power source or power units within network devices.
Ensures business continuity, when a 3
rd
party UPS is added it ensures continuity of AC power to switches and other network devices even during AC mains failure, power sag, surges, or blackouts.
Overview
The Nortel Redundant Power Supply 15 improves network availability by protecting Nortel stackable switching solutions from power outages. The Redundant Power Supply 15 maintains network operation in case of device power failure. Power is provided to switches simultaneously without requiring a device reboot. The modular chassis allows you to acquire additional modules as your network grows. The Redundant Power Supply Modules are Hot­Swappable so additional protection
can be added within normal office hours and without downtime of the network.
The Redundant Power Supply 15 can be used to provide power sharing or protection for Nortel Ethernet Routing Switch 5520 and Ethernet Switch 470-PWR, as well as power protection for non-PoE switches. Up to 12 switches can be power protected with one Redundant Power Supply 15 providing maximum efficiency. For additional resiliency, the Redundant Power Supply 15 provides customers with the freedom to choose their corporate standard Uninterruptible Power Supply vendor.
The Redundant Power Supply 15 is 2RU high and can accommodate up to three Redundant Power Supply Modules. These Redundant Power Supply Modules provide up to 600W of power each. The Redundant Power Supply Modules feature two front facing LED indicators to display both status of AC and DC power. A basic Redundant Power Supply 15 configuration consists of a chassis that is shipped with two blank panels preinstalled. The Redundant Power Supply 15 requires at least one hot swappable Redundant Power Supply Module which must be ordered as separate item.
Additionally a DC power cable needs to be ordered to connect to the DC power socket of the switch. Depending on the switch type a separate DC-to-DC converter is required.
Power Protection Mode
The Redundant Power Supply 15 provides power protection for Business Policy Switch 2000, BayStack 380, Ethernet Switch 470, 470-PWR and Ethernet Routing Switches 5510, 5520 and 5530, as well as Ethernet Services Unit 1400, 1450 and 1800. In case of a power outage the Redundant Power Supply 15 will immediately take over, providing power to the switch. Ethernet Routing Switch 5520 and Ethernet Switch 470­PWR switches can be configured to use either the internal or external power source to provide
Ideal For:
• New and existing mid-tier and Enterprise Customers that need RPS functionality in a single chassis.
• Enterprise Customers requiring more power for PoE devices than a single switch can deliver itself.
• Enterprise customers that already have a UPS and only need power redundancy.
• When there is little space in the wiring closet and redundant power is needed
.
1
power to the switch itself and connected PoE devices. In this case a total of 320W of power can be provided to connected devices with a maximum of 15.4W per port as defined in the 802.3af standard, or an average of 13.3W to all ports on a 24 port switch, or
6.6W to all ports on a 48 port switch. When a 3
rd
party UPS is added, it ensures continuity of AC power even during AC mains failure, power sag, surges, or blackouts. Additionally the Redundant Power Supply 15 can protect up to 4 non­PoE switches
(1
per 600W Redundant Power Supply Module. Up to 3 modules fit in an Redundant Power Supply 15 chassis.
(1
. To provide redundancy to an Ethernet Routing Switch 5530-24TFD use one Redundant Power Supply Module per switch
Power Sharing Mode
When the Redundant Power Supply 15 is used together with Ethernet Routing Switch 5520-48T or Ethernet Switch 470-48T-PWR internal power supplies, output power per port can be increased to full 15.4W on all 48 ports. When configured to use both internal and external power (power sharing
mode) the switch total PoE power output is increased to 740W. In power sharing mode up to 740W, or 15.4W per port on a 5520-48T or 470-48T-PWR can be provided.
Typical applications
PoE devices
Connect up to 3 x 5520-24T, 5520-48T, 470-24T-PWR or 470­48T-PWR to provide each switch with 320W for Power over Ethernet Redundancy or 740W in power sharing mode. Order DC cable AA0005018 to connect 5520 or 470-PWR switches.
Non-PoE devices
Connect up to 12 Business Policy Switch 2000, BayStack 380, Ethernet Switch 470 or Ethernet Routing Switch 5510, as well as Ethernet Services Unit 1400, 1450 and 1800 to provide power protection to these switches. A single 600W Redundant Power Supply Module can protect up to 4 switches from power disruption. Use DC cable AA0005021 to
connect 4 switches to a single Redundant Power Supply Module. For maximum deployment flexibility a long DC cable of 25ft/7.6m is available (AA0005020).
How to choose….
Various flexible deployment options are available for the Redundant Power Supply 15. It can be used in conjunction with many Nortel Ethernet Routing Switches and Ethernet Switches. The table below outlines valid combinations.
Qualification questions:
• Is network uptime and uninterrupted activity critical to your business?
• Do you have multiple wiring closet switches?
• Is space limited in your wiring closets?
• Do you have multiple high demanding PoE devices connecting into you wiring closet?
Switch Type
Chassis
AA00050
17
600W RPS
Module
AA0005?19
(3
DC-to-DC
converter
DC cable for
PoE switches
DC cable
10ft/3m
(4
DC cable
25ft/7.6m
(4
Ethernet Routing Switch 5510
1
1 per 4
switches
AL1904007 AA0005021 AA0005020
Ethernet Routing Switch 5520
1 1 incl. AA0005018 - -
Ethernet Routing Switch 5530
1 1 incl. AA0005018 - -
Ethernet Switch 470 1
1 per 4
switches
AL1904005 - AA0005021 AA0005020
Ethernet Switch 470-PWR 1 1 incl. AA0005018 - -
Ethernet Switch BPS2000 1
1 per 4
switches
AL1904006 - AA0005021 AA0005020
BayStack 380 1
1 per 4
switches
AL1904006 - AA0005021 AA0005020
Ethernet Services Unit 1400
1
1 per 4
switches
AL1904004 - AA0005021 AA0005020
Ethernet Services Unit 1450
1
1 per 4
switches
AL1904004 - AA0005021 AA0005020
Ethernet Services Unit 1800
1
1 per 4
switches
AL1904004 - AA0005021 AA0005020
Ethernet Switch 460
use
BayStack
10 RPSU
- - - - -
(3
? Must be replaced with country code A through F for local power cord options.
(4
use one cable to connect up to 4 switches
2
Example configuration
This hypothetical example show the various items required for a customer quotation of a Redundant Power Supply Unit 15. A customer wants to provide power redundancy with the Redundant Power Supply 15 to the following Nortel switching products:
1 x Ethernet Routing Switch 5510-24T 1 x Ethernet Routing Switch 5520-48T-PWR 1 x Ethernet Switch 470-48T 1 x Ethernet Switch 470-48T-PWR 1 x BayStack 380-24F
Your Redundant Power Supply 15 quote should include the following components:
Order Number
Product Description Qty.
A
AA0005017 Redundant Power Supply 15 - Chassis (Supports three power supplies). 1
B
AA0005A19
Redundant Power Supply 15 - 600 Watt Redundant Power Supply Module. Installs in RPS 15 Chassis AA0005017, and requires purchase of RPSU connection cable. (No Power cord).
3
C
AA0005021
Redundant Power Supply 15 Short Connecting Cable (3m/10ft) for up to 4 x Ethernet Routing Switch 5510, Ethernet Switch 470, 380, Optera Metro 1200, 1400, 1450.
1
D
AA0005018
Redundant Power Supply 15 - Connecting Cable for Single Ethernet Routing Switch 5520, 5530 or Ethernet Switch 470-PWR
2
E
AL1904007
-48 V DC-to-DC converter, for installation in the Ethernet Routing Switch 5510-48T and 5510-24T, for use with the BayStack 10.
1
F
AL1904005
-48 V DC-to-DC converter, for installation in the Ethernet Switch 470­48T, for use with the BayStack 10 Power Supply Unit.
1
G
AL1904006
-48 V DC-to-DC converter, for installation in the BS 380 or BPS, for use with the BayStack 10 Power Supply Unit.
1
A) A Redundant Power Supply Unit 15 chassis to house the 600W Redundant Power Supply Modules is required; B) In total three 600W modules are needed: All PoE switches need a separate 600W module. In this example we need two
for PoE switches: one for the Ethernet Routing Switch 5520 and one for the Ethernet Switch 470-48T-PWR. 3 Non­PoE switches like the Ethernet Switch 470,the Ethernet Routing Switch 5510 or BayStack 380 require a third 600W module; Now all three slots of the chassis are filled with 600W Redundant Power Supply Modules. You can choose various power cord options, this example is without a power cord.
C) When connecting Non-PoE switches like Ethernet Switch 470, Ethernet Routing Switch 5510 or BayStack 380, you can
use the 1 : 4 cable that allows you to connect up to four switches to one 600W module. In this example, the customer could add another Non-PoE switch in the future
D) When connecting a PoE switch like the Ethernet Routing Switch 5520-24T-PWR or Ethernet Switch 470-48T-PWR to
the Redundant Power Supply unit 15 a 1:1 connecting cable is required to connect each PoE switch to one separate 600W module. In this example we have two of these switches, so we need two connecting cables.
E) Some switch models require a separate DC-to-DC converter to enable the DC power slot at the back of the switch and
connect a DC cable. This DC-to-DC converter is typical for the Ethernet Routing Switch 5510;
F) To connect an Ethernet Switch 470 to the Redundant Power Supply 15, this DC-to-DC converter, that is specific to
the Ethernet Switch 470, is required.
G) To connect a BayStack 380 to the Redundant Power Supply 15, this DC-to-DC converter, that is specific to the
BayStack 380, is required.
Please note that although Ethernet Routing Switch 5530-24TFD is not a PoE switch, it has a 1:1 requirement for a 600W Redundant Power Supply module. Also the DC-to-DC converter is already inbuilt. So from a RPS 15 engineering perspective, you should treat it as if it is a 5520 or 470-PWR switch.
Technical Specifications
Interfaces Standard AC wall plug- NEMA 5-15 P (AC in)
DC connector Electromagnetic Compatibility
EN55022/CISPR 22, Class A, EN55024/CISPR 22, Class A, VCCI, Class A (Japan),
BSMI Class A (Taiwan), ACA, AS/NZ 3548, Class A (Australia), FCC Part 15 Class
A (US) MTBF >2,000,000 hours
Noise level <60 dBA
3
Shock/Vibration NEBS GR-63 Std, MIL-STD-810E, METHOD 516.4, procedure IV when packaged for
shipping. NEBS GR-63-CORE Sect. 5.3.1, Category A container. NEBS GR-63-
CORE, Sect. 5.1.1, NEBS GR-63-CORE, Sect. 5.4.3 Physical Dimensions 14.57 x 5.315 x 3.38 inches,( 37.0 x 13.5 x 8.58 cm),Weight: Chassis 15lbs/6.8kg,
RPS module 7.5lbs/3.4kg Power Requirements
Input requirements: Input voltage: 90-264VAC
Input frequency range: 47 to 440 Hz, Nominal: 50 / 60 Hz, Inrush current:
max. 40A,
Leakage current: 0.5 mA to 3.0 mA maximum for any input voltage
Output requirements: Output voltage and current 600W power supply module
DC output: 47.5V output, 600W, Minimum Load: 0A, Full Load: 12.5A Environmental Operating temperature: 0 ° to 45 ° C
Storage temperature: -25° C to 70° C
Operating relative humidity: 5% to 85% relative humidity, non-condensing
Storage temperature humidity: 95% maximum relative humidity, non-condensing
Operating altitude: Up to 10,000 feet above sea level
Storage altitude: Up to 30,000 feet above sea level
Cooling, forced air: 2X30 CFM, 80 mm fans Standards and
Certifications
TUV GS mark, cTUVus mark, IEC950/EN60950, EN50091-1, CB certificate and report
with all national deviations. AS/NZS 3260, NOM-019-SCFI, IRAM
Ordering Information
AA0005017 Redundant Power Supply 15 - Chassis (Supports three power supplies).
Redundant Power Supply 15 - Connecting Cable for Single Ethernet Routing Switch 5520, 5530 or Ethernet Switch 470-PWR.
AA0005018
Redundant Power Supply 15 - 600 Watt Redundant Power Supply Module. Installs in RPS 15 Chassis AA0005017, and requires purchase of RPSU connection cable. (No power cord included)
AA0005?19
Redundant Power Supply 15 Long Connecting Cable (7.6m/25ft) for up to 4 x Ethernet Routing Switch 5510, Ethernet Switch 470, 380, Optera Metro 1200,400, 1450
AA0005020
Redundant Power Supply 15 Short Connecting Cable (3m/10ft) for up to 4 x Ethernet Routing Switch 5510, Ethernet Switch 470, 380, Optera Metro 1200, 1400, 1450.
AA0005021
AA0005022 Redundant Power Supply 15 - Blank Panel for Chassis
** The seventh character (?) of the switch order number must be replaced with the proper code to indicate desired product nationalization: “A” – No power cord included “B” – Includes European “Schuko” power cord common in Austria, Belgium, Finland, France, Germany, The Netherlands, Norway, and Sweden “C” – Includes power cord commonly used in the United Kingdom and Ireland “D” – Includes power cord commonly used in Japan “E” – Includes North American power cord “F” – Includes Australian power cord, also commonly used in New Zealand and the People’s Republic of China
In the United States: In Asia Pacific: In Greater China:
Nortel Nortel Nortel
35 Davis Drive Nortel Networks Centre Sun Dong An Plaza,
Research Triangle Park, NC 27709 USA 1 Innovation Drive 138 Wang Fu Jing Street
Macquarie University Research Park Beijing 100006, China
Phone: (86) 10 6510 8000
In Canada:
Macquarie Park, NSW 2109
Nortel Australia
In Europe:
8200 Dixie Road, Suite 100 Tel +61 2 8870 5000
Brampton, Ontario L6T 5P6 Canada Nortel
In Caribbean and Latin America:
Maidenhead Office Park, Westacott Way
Nortel Maidenhead Berkshire SL6 3QH UK
1500 Concorde Terrace Sunrise, Phone: 00800 8008 9009 or
FL 33323 USA +44 (0) 870-907-9009
Nortel is a recognized leader in delivering communications capabilities that enhance he human experience, ignite and power gobal commerce, and secure and protect the wrld’s most critical information. Serving both service provider and enterprise customers, ortel delivers innovative technology solutions encompassing end-to-end broadband, Voice over IP, multimedia services and applications, and wireless broadband designed to help people solve the world’s greatest challenges. Nortel does business in more than 150 countries. For more information, visit Nortel on the Web at www.nortel.com. For more information, contact your Nortel representative, or call 1-800-4 NORTELor 1-800-466-7835 from anywhere in North America. This is the Way. This is Nortel, Nortel, the Nortel logo, the Globemark, Passport and Optivity are trademarks of Nortel Networks. All other trademarks are the property of their owners. Copyright © 2005 Nortel Networks. All rights reserved. Information in this document is subject to change without notice. Nortel assumes no responsibility for any errors that may appear in this document.
4
NN112360-051806
Loading...