Nortek Security and Control 2GIG ZWM500 User Manual

STM-5
94V-O
2014 GC3 Z–Wave Rev 3.0
FCC ID: WDQ-ZWM-500 IC ID: 7794A-ZWM500
line-gc3-bac k up-ba ttery-en
line -gc3-pie z o-sounde r-en
line-gc3-panel-speake r-en
2GIG® GC3 Security & Automation System
2GIG-ZWM-500 Z-Wave Module Installation Instructions
10008951A | Proprietary & Confidential
Installing the 2GIG Z-Wave Module
The 2GIG Z-Wave Module (2GIG-ZWM-500) providesthe GC3 Security& Automation System with the abilityto communicate with up to 232 smart home devices usingthe Z-Wave wirelesscommunicationprotocol.

Box Contents

1—2GIG Z-Wave Module (2GIG-ZWM-500)
Figure 1 2GIG Z-Wave Module

Install the Z-Wave Module

To installthe 2GIG Z-Wave Module into a Control Panel,do the following:
1. If the Cellular Radio Module bay islocked,remove the faceplate and then move the door-lock screw to the UNLOCK position. See "(Optional) Lock/Unlockthe Cellular Radio Module Door" on the next page. Otherwise, continue with step 2.
2. Remove the hinged door from the GC3 Control Panel.
Figure 4 GC3 Panel—Backup Battery Connector
7. Disconnect the Piezo Sounder connector.
Figure 5 GC3 Panel—PiezoSounder Connector
8. Disconnect the internal siren/speaker connector.
Figure 2 Cellular Radio Module—Hinged Door
3. If a Cellular Radio Module ispresent in the system, pullthe tab to remove remove it. Otherwise, skip this stepand continue with step 4.
4. Remove the backplate'sscrew lockfrom the bottom of the GC3 Panel. This unlocks the panel's backplate from the rest of the chassis..
Figure 3 GC3 Panel Backplate—Locking Screw
5. Separate the backplate from the GC3 Panel.
6. Disconnect the wired backup battery pin from the PCBbattery connector.
Figure 6 GC3 Panel—Internal Siren/Speaker Connector
9. Remove the two screws that secure the rear plate to the chassisand remove the plate.
Figure 7 GC3 Panel—Rear Plate
Nortek Security &Control |1950Camino VidaRoble, Suite 150 |Carlsbad, CA92008-6517 | USA| 800-421-1587 | www.nortekcontrol.com
Copyright © 2015 Nortek Security &Control LLC.
1
A
B
2GIG® GC3 Security & Automation System
2GIG-ZWM-500 Z-Wave Module Installation Instructions
10008951A | Proprietary & Confidential
10. Insert the 2GIGZ-Wave module into the STM-5 connector on the PCB and secure with the Phillipshead screw.
Figure 10 GC3 Panel—Removeable Faceplate
2. Remove the door-lock screw from the UNLOCK position on the right.
Figure 8 GC3 Panel—Installthe Z-Wave Module
11. Replacethe rear plate and secure it with two Phillipshead screws.
12. Connect the internal siren/speaker connector, the Piezo Sounder connector, and the backup battery connector to their respective PCB connectors.
13. Install the backplate to the chassisand secure with the screw lockon the bottom of the Control Panel.
14. Install the Cellular Radio Module, if one was present.
15. Install the hinged door.
Figure 11 GC3 Panel—UNLOCK position

(Optional) Lock/Unlock the Cellular Radio Module Door

The Cellular Radio Module fitsinto the bay on the sideof the GC3 Panel and features a built-in door lock under the faceplate. The Control Panel ships with the door-lockscrew inthe UNLOCK position.To limit the possibilityof someone removing the door, installers have the option of moving the screw to the LOCK position.
Figure 9 GC3 Cellular Radio Module Door Lock
To lockand unlockthe Cellular Radio Module door:
1. Useyour fingertips or carefully insert a screwdriver at the edge of the faceplate. Then gently pry the faceplate from the chassis.
3. Install the screw into the LOCK position on the left. Thislocksthe hinged door on the GC3 Control Panel.
Figure 12 GC3 Panel—LOCK position
4. Snap the faceplate backon the GC3 Control Panel.
FCCPart 15: Class B Digital Device Statement for the 2GIG-ZWM-500
If the module'slabel is not visiblewhen installed, then an additional permanent labelreferring to the enclosedmodule: "Contains Transmitter Module FCC ID: WDQ-ZWM500" must be placed on the rear panel in a visible location.
FCC ID: WDQ-ZWM500
IC ID: 7794A-ZWM500
This device hasbeen tested and found to comply with the limitsfor a ClassB digital device, pursuant to Part 15 of FCC Rules. Operation is subject to the following two conditions:
1. Thisdevicemay not cause harmful interference, and
2. Thisdevicemust acceptinterference received,including interference that may cause undesired operation.
These limits are designed to providereasonable protection againstharmful interference in a residential installation.Thisequipment generates and can radiate
Nortek Security &Control |1950Camino VidaRoble, Suite 150 |Carlsbad, CA92008-6517 | USA| 800-421-1587 | www.nortekcontrol.com
Copyright © 2015 Nortek Security &Control LLC.
2
Loading...
+ 1 hidden pages