Doorbell
SLIDE BATTERY IN HERE
PLUS SIDE UP
2GIG-DBELL1-345
Operating Instructions
The 2GIG-DBELL1-345 is a dual purpose doorbell that will work with both
the standard 24V wiring in the house and also wirelessly with the 2GIG
Control Panel. It features a button that will remain illuminated when hooked
to the 24V house door bell wiring and is fully water resistant.
Doorbell button
Installation & Mounting Guidelines
To mount the base, do the following:
Mount the DBELL1 on the door frame using the orientation shown in Figure 2. Use the
1
supplied phillips head screws to attach it to the surface.
Pull the existing house 24V AC wiring through the hole in the rear of the base.
2
Place the supplied O-ring around the perimeter of the base as shown in Figure 2.
3
Notes:
If possible, locate sensors within 100 ft (30 m) of the panel, While a transmitter may have a
range of 350ft. (106 m) or more out in the open, the environment at the installation site can
have a significant effect on transmitter range. Sometimes a change in sensor orientation
can help overcome adverse wireless conditions.
Although the DBELL1 has been designed to withstand weather, avoid mounting sensors in
areas where they will be exposed to extreme moisture or where the sensor operating
temperature range of 32 to 120°F (0 to 49°C) will be exceeded.
To complete the installation:
Attach the existing 24V AC household doorbell wiring to base of the module using 6-32 x
1
1/8” machine screws. If this step is skipped, the door bell will work only with the 2GIG
control module and the LED will not be illuminated. Refer to Figure 3.
Pull the battery tab out and discard.
2
Snap the top part of the assembly to the base.
3
Assembly is now complete.
4
Figure 1
Programming
The following steps describe general guidelines for programming (learning) the
sensor into the alarm control panel memory. For more details, refer to the 2GIG
Installation & Programming Instructions.
1
Set the panel to sensor learning mode.
2
Press and release doorbell button on the sensor until the panel responds (see Figure 1).
3
Exit program mode.
4
Verify that the household wiring is also working by sounding the doorbell.
Testing
Before mounting the sensor, verify that the sensor mounting location provides good
RF communication to the panel. To verify, do the following:
Put the control panel into sensor test mode.
1
Press and release the doorbell button and listen for siren or keypad beeps to determine
2
appropriate response (refer to the control panel Installation instructions).
Exit sensor test mode.
3
Verify that the household 24V AC connection is working by pressing the doorbell button to ring
4
the doorbell.
Access hole 24V
door bell wire
Figure 2
Figure 3
Battery
Pull Tab
Screw
mounting
features
Slot for
O-ring
Note: It is recommended that a system test be performed per the Operation & User's Guide at least once a year.
Battery Installation & Replacement
If a sensor battery is low, a low battery notification will be indicated on the 2GIG Alarm Control Panel's screen. When the
2GIG alarm system Indicates that there is a sensor with a low battery, replace the battery immediately. Use only the
recommended replacement batteries (see Specifications).
To install or replace the battery, do the following:
To remove the sensor cover, use your finger to press the tab on the end of the case. This will disengage the clip holding
1
the cover to the base.
Place a small flathead screwdriver in the slot between the metal clip (see Figure 3) and the battery and push it out taking
2
care not to scratch the battery terminal on the PCB.
Insert the replacement battery with the + sign facing out (see Figure 3)
3
Verify programming and RF communication with the panel (see Testing).
4
WARNING! The polarity of the battery must be observed, as shown (see Figure 3). Improper handling of lithium
batteries may result In heat generation, explosion or fire, resulting personal injuries. Replace only with the same
or equivalent type of battery as recommended by the manufacturer (see Specifications).
Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be made In
accordance with the waste recovery and recycling regulations In your area.
Keep away from small children. If batteries are swallowed, promptly seek medical attention.
California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY In
California, USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.
Specifications
Wireless Signal Range
Code Outputs
Supervisory
Transmitter Frequency
Transmitter Frequency Tolerance
Transmitter Bandwidth
Modulation Type
Unique ID Codes
Supervisory Interval
External Input Sampling Current
External Input
Sensor Dimensions (HxD)
Weight (Including battery & magnet)
Housing Material
Color
Operating Temperature
Relative Humidity
Battery (Installed with pull tab)
Regulatory Listing(s)
Warranty*
Included Accessories
350 ft, open air, with 2GIG Wireless Alarm Control Panel
Alarm Restore; External Alarm; External Restore
Low Battery
345.000 MHz (crystal controlled)
± 15kHz
24kHz
Amplitude Shift Keying-On/Off Keying (ASK-OOK)
Over one (1) million different code combinations
70 minutes
20 uA
24V AC Standard doorbell circuit
2.75 X 1.17 X 0.63 in. (6.98 X 2.97X 1.60 cm)
1.1 oz. (31.2 g)
ABS plastic
White
32° to 120°F (0° tO 49°C)
5-95% Non-Condensing
One (1) Panasonic CR2032, or equivalent Lithium batteries
FCC Part 15, Industry Canada
Two (2) years
Two (2) Phillip's flat-head screws
FCC & INDUSTRY CANADA REGULATORY INFORMATION
FCC ID: WDQ-DBELL1345
Industry Canada ID: 7794A-DBELL1345
NOTICE: Unauthorized changes or modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
.
Reorient or relocate the receiving antenna.
.
Increase the separation between the equipment and the receiver
.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
.
Consult the dealer or an experienced radio/television technician for help
Technical Support:
1-866-670-1591
www.2gig.com
©2011 2gig Technologies Inc. All Rights Reserved
PN 77-000004-001 Rev B