Nortek Security and Control 2GIG CNTRLX345 User Manual

PRINTER’S INSTRUCTIONS:
Wireless Security System
GUIDE,USER,APX - LINEAR P/N: 229528 X14 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND WITH 80 LB. WHITE COATED COVER - SIZE: 5.500” X 8.500” - SCALE: 1-1 - FOLDING: ALBUM FOLD - BINDING: SADDLE-STITCH
Operation &
User’s Guide
WARNING: Owner’s Instruction Notice
Not to be removed by anyone except occupant
The GO!control Security System
Congratulations on your ownership of an APX Security System! This wireless system offers protection for your property against burglary, protection for yourself and family with 24-hour emergency monitoring, and optionally fi re and carbon monoxide detection for your home.
The heart of the system is the Control Panel. It receives the wireless radio signals from remote system “sensors” that monitor doors, windows, motion detectors, smoke detectors, carbon monoxide detectors, and panic buttons. The Control Panel processes these signals and controls the alarm siren. The system can communicate to an alarm monitoring “Central Station” over the regular telephone network and optionally over the cellular telephone network to report violations, alarms, and system status.
The Control Panel is operated using its color touch screen display that shows easy to identity buttons and icons. The system can be armed or disarmed directly at the Control Panel, or by using optional key fob remote controls, or remotely over the telephone. The Control Panel displays helpful information regarding the system and sensor status, system and alarm history, and trouble alerts.
Being fully “supervised”, the APX Security System continuously monitors itself and its sensors. If an issue occurs, such as a low sensor battery, the trouble alert will be displayed and logged by the Control Panel and optionally reported to the Central Monitoring Station. This way, the trouble can be addressed and corrected promptly, maintaining the integrity of the system.
With the system’s built-in Z-Wave home automation capability, you can control your Z-Wave enabled household appliances from the Control Panel or remotely from a PC and the Internet from anywhere in the world... even through your cell phone! (This is an optional feature, check with your security professional for availability with your system.)
Many insurance companies offer discounts on homeowners and renters policies when a security system is installed. Discount credits vary with different companies and generally increase in savings with an increase in the level of protection. Ask your insurance agent about savings available to you.
System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Sensor Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Fire Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Burglary Protection . . . . . . . . . . . . . . . . . . . . . . . . . 3
User Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Control Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wireless Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Main Display Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Home Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Security Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Arming Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Menu Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Burglary Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operating the System . . . . . . . . . . . . . . . . . . . . . . . . . 7
Sensor Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Checking that All Sensors are Closed . . . . . . . . . . . 8
Viewing Each Sensor’s Status . . . . . . . . . . . . . . . . . . 8
Force Bypassing Sensors . . . . . . . . . . . . . . . . . . . . 9
Manual Bypassing or Un-bypassing Sensors . . . 9
Stay Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Entry Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Quick Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Arming to Stay Mode . . . . . . . . . . . . . . . . . . . . . . . 11
Away Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Exit and Entry Delays . . . . . . . . . . . . . . . . . . . . . . . 12
Silent Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Quick Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Auto Stay Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Arming to Away Mode . . . . . . . . . . . . . . . . . . . . . . 13
Disarming the System . . . . . . . . . . . . . . . . . . . . . . . . 14
Disarming from Stay Mode . . . . . . . . . . . . . . . . . . 14
Disarming from Away Mode . . . . . . . . . . . . . . . . . 14
If a Burglary Alarm Occurs . . . . . . . . . . . . . . . . . . . . 15
Burglary Alarm Siren . . . . . . . . . . . . . . . . . . . . . . . 15
Alarm Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optional 2-Way Voice Communications . . . . . . . 15
Key Fob Arming and Disarming . . . . . . . . . . . . . . . . 16
Key Fob Arming to Stay Mode . . . . . . . . . . . . . . . 16
Key Fob Arming to Away Mode . . . . . . . . . . . . . . 16
Key Fob Disarming . . . . . . . . . . . . . . . . . . . . . . . . . 16
Key Fob Emergency . . . . . . . . . . . . . . . . . . . . . . . . 16
Key Fob Auxiliary . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Wireless Keypad Arming and Disarming . . . . . . . . 17
Wireless Keypad Arming to Stay Mode . . . . . . . 17
Wireless Keypad Arming to Away Mode . . . . . . 17
Wireless Keypad Disarming . . . . . . . . . . . . . . . . . 17
Wireless Keypad Fire Emergency . . . . . . . . . . . . 17
Wireless Keypad Police Emergency . . . . . . . . . . 17
Fire Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fire Alarm System . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Manual Fire Alarm . . . . . . . . . . . . . . . . . . . . . . . . . 18
Automatic Fire Alarm . . . . . . . . . . . . . . . . . . . . . . . 18
Silencing a False Fire Alarm . . . . . . . . . . . . . . . . . 18
Recommended Smoke Detector Locations . . . . . . 19
Emergency Evacuation Plan . . . . . . . . . . . . . . . . . . . 20
Emergency Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
24-Hour Emergency Buttons . . . . . . . . . . . . . . . . . . 21
Panic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Emergency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
System Trouble Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Trouble Alert Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Nighttime Trouble Alert Holdoff . . . . . . . . . . . . . . . . 22
Table of Contents
System Status Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
AC Power Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Phone Line Failure Icon . . . . . . . . . . . . . . . . . . . . . . . 23
Backup Battery Status Icon . . . . . . . . . . . . . . . . . . . 23
Test Mode Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Remote Installer Access Icon . . . . . . . . . . . . . . . . . 23
Radio Modem Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Remote Control by Telephone . . . . . . . . . . . . . . . . . . . . 24
Telephone Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Calling the System . . . . . . . . . . . . . . . . . . . . . . . . . 24
Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Bypassing Sensors Remotely . . . . . . . . . . . . . . . . 25
System Toolbox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
User Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
User Code Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Adding a User Code . . . . . . . . . . . . . . . . . . . . . . . . 26
Changing a User Code . . . . . . . . . . . . . . . . . . . . . . 26
Deleting a User Code . . . . . . . . . . . . . . . . . . . . . . . 27
Duress User Code . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Adding a Duress User Code . . . . . . . . . . . . . . . . . 27
Secret Duress Button. . . . . . . . . . . . . . . . . . . . . . . 27
System History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Sensor Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Panel Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Telephone Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cell Phone Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Chime Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Brightness / Volume . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Backlight Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Display Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Touch Screen Calibration . . . . . . . . . . . . . . . . . . . . . 34
Set Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Display Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Installer Set Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Siren Run Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Fire Horn Run Time . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Exit Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Entry Delays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
24-Hour Emergency Functions . . . . . . . . . . . . . . . . . 37
Quick Arming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Quick Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Quick Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Auto Un-bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Auto Stay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Key Fob Arm/Disarm Sound . . . . . . . . . . . . . . . . . . . 38
Key Fob Disarm After Alarm Sound . . . . . . . . . . . . . 38
Exit Delay Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Cancel Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Cancel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Dialer Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
2-Way Voice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Audio Listen-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Telephone Remote Control Answer. . . . . . . . . . . . . 39
Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Wireless Product Notice . . . . . . . . . . . . . . . . . . . . . . 40
FCC Part 15 Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
FCC Telephone Rules and Regulations . . . . . . . . . . 40
FCC Part 68 Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Industry Canada Notice (for Canadian users) . . . . 42
Service Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Important Power Supply Notice . . . . . . . . . . . . . . . 43
Important Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Alarm System Limitations . . . . . . . . . . . . . . . . . . . . . 44
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
1
System Overview
General Information
This system provides three forms of protection: burglary, fi re, and emergency, depending on the options set by the installer. The system consists of the Control Panel with a color touch screen, wireless sensors that provide perimeter and interior burglary protection, and wireless smoke and carbon monoxide detectors. In addition, optional remote control key fobs, wireless panic pendants, and wireless keypads may have been provided or installed.
The system monitors all protection “zones” and the system’s status. It will display monitoring information and control the alarm siren. Your system may also have been setup to send alarm and status reports to a Central Monitoring Station and has the capability for 2-way voice communications with the alarm monitoring operator.
Features
Following is a list of standard features and options that can be included in your system. Ask your installer which options are available to you and check the boxes that apply.
STAY and AWAY arming modes. Stay Mode arms the system perimeter only and is used typically at night when the premises are occupied. Away Mode arms the system perimeter and interior, it’s used when the premises are unoccupied.
Eight user unique 4-digit codes to operate the system. The system supports one “Master User Code” that can assign and maintain the other seven User Codes.
One of the eight User Codes functions as a Duress User Code. Controlling the system with this code gives the appearance of normal operation, but using it secretly sends a “duress” report to the Central Monitoring Station to initiate a silent alarm call for help.
Voice announcements from the Control Panel. The system has a large vocabulary of descriptive words that can be assigned to sensors so each will have a unique announcement such as “front door” or “baby’s room window” if desired.
Home automation with the built-in Z-Wave controller for remote controlling Z-Wave enabled home appliances (optional feature).
Alarm history with system event log. Each alarm and system alert is logged into the system’s memory. These events can be displayed and reviewed at the Control Panel or remotely by the Central Monitoring Station.
Real time clock and calendar shows on the system’s display and is used to time stamp items in the event log.
2-way voice communication. After an alarm, the system can connect with a Central Station operator so they can converse with people in the premises.
Remote control of the system over the telephone.
Remote control of the system using a Web-enabled device through the Internet.
Three optional 24-hour emergency functions: PANIC, FIRE, and EMERGENCY. These functions can be activated by buttons on the Control Panel, using wireless sensors, from the wireless keypad, or from portable pendant devices.
2
System Overview
General Operation
Following are general operational concepts that your system supports. Understanding these concepts will help you to use your security system to it fullest extent.
Sensor Types
The system’s wireless sensors have been assigned to selected “types” (sometimes called “zones” in the alarm industry). The sensor type determines how and when the system will react to a signal from the sensor. Some sensors are armed 24 hours a day, other sensors are only armed when the system is armed.
Fire Protection
If fi re protection wireless smoke detectors have been installed in your system, they are armed 24 hours-a-day. They will sound an alarm when smoke is detected and can report the fi re alarm to the Central Monitoring Station. Refer to the Fire Alarm System section of this manual for important emergency planning and evacuation information.
Burglary Protection
Burglary protection is provided by perimeter and interior sensors. When the system is armed in the Away Mode, both perimeter and interior sensors are armed and can trigger an alarm. When the system is armed in the Stay Mode, only the perimeter sensors are armed and can trigger an alarm.
Both arming modes offer an “Exit Delay” that allows time to leave the premises without triggering the alarm. Upon re-entry, the system offers an “Entry Delay” through certain points of protection that allows you time to disarm the system before an alarm is triggered.
Sensors can be set to sound a chime and/or a voice announcement when they are triggered. So you can monitor your doors and windows while the system is disarmed.
User Codes
The system installer has pre-programmed a Master User Code for your system. This code can be used to control the system as well as assign and change the other seven User Codes. The Master User Code can also access several system setup settings in the User Toolbox.
Alarms
When an alarm occurs, the Control Panel’s siren and an external siren (if installed) will sound for a preset time. During alarms and after disarming, the alarm history button will display all the alarms that have occurred, and which sensors were involved. The alarm history clears the next time the system is armed or can be cleared manually.
3
Control Panel Features
ALARM SOUNDER
AND SPEAKER
Sounds all system local alarms,
voice prompts, system sounds, and
audio for 2-way voice communications
with the Central Station
Shows all system information, status,
programming, and functions as the keypad
Display cycles clock, calendar, and weather
COLOR DISPLAY
WITH TOUCH SCREEN
(press to manually change)
Lights green when all sensors are ready to arm
BUTTON / INDICATOR
Lights red when system is armed
Blinks red during pre-alarm and alarm
Not lit when any sensor is not ready to arm
Indicator flashes when system is on battery backup
Flashes orange when sensors are open while on battery backup
EMERGENCY
BUTTON / INDICATOR
Lights white when enabled for emergency alarms
Flashes white during emergency alarm
4
HOME
MICROPHONE
For 2-way voice communication
with the Central Station
Wireless Sensors
Your security system has wireless sensors. Some sensors will be visible, other sensors are hidden inside the door jambs. Depending on your installation, there may be other types of sensors shown below. Be sure your installer shows you all the sensors installed in your system.
Door / Window Sensor
Glass Break Sensor
Carbon Monoxide Detector
Motion Sensor
Smoke Detector
Key Fob Remote
Panic Button Remote
Wireless Keypad
5
Main Display Screens
The Control Panel is programmed and operated using the color touch-screen display. The display will show various buttons, indicators, and text to guide and inform you.
The top bar on the display shows the current system mode, scrolling text of any pending alerts, and system status icons for AC power, telephone line, and backup battery.
Home Screen
The Home Screen is the top level screen. It shows the system status with icons to indicate system conditions. It also displays the time and date. The Home Screen displays the SECURITY and HOME CONTROL buttons. Pressing the
button on the Control Panel will display the
Home Screen.
Security Screen
The Security Screen shows the system status and offers three buttons for ARM, MENU, and STATUS. It also displays the time and date. If messages, alarm, or trouble alerts are pending, the Security Screen will display buttons indicating the number of pending messages.
The Home Screen
The Security Screen
Trouble Alert
Alarm Memory
Message
Arming Screen
The Arming Screen is used to arm the security portion of the system. It displays the system status and arming buttons for STAY and AWAY. Two option check box buttons for ENTRY DELAY and SILENT EXIT are displayed.
Menu Screen
The Menu Screen shows the system status and offers buttons for ARM and TOOLBOX. If the emergency option is set, an EMERGENCY button is displayed. Two option check box buttons for CHIME and VOICE are displayed.
Status Screen
The Status Screen lists system status and any alerts. The date and time of any alerts are listed in the displayed log. One option button for SILENCE is displayed, it stops the voice announcement of the system status.
6
The Arming Screen
The Menu Screen
The Status Screen
Burglary Protection
Operating the System
When your system was setup by your installer, wireless sensors were placed to monitor specifi c doors and windows. The installer selected these doors and windows as likely places where an unlawful intrusion might occur and could be detected. Each sensor was programmed to have the system react in a specifi c way.
Some sensor types such as smoke detectors, carbon monoxide detectors, panic buttons, etc. are always active and can trigger an alarm at any time. Other sensors on protected doors and windows are part of the burglary protection part of the system, and can be turned on or off. Turning on the burglary protection part of the security system is called “Arming the System”. The burglary protection part of the system can be armed in two modes; Stay Mode or Away Mode.
Refer to the fl oor plan below. It shows a typical residential installation and the various types of wireless sensors and their function.
FRONT AND SIDE DOOR SENSORS
ES
PIR
DW
GB
HAVE EXIT/ENTRY DELAY
DWDW
DW
DW
DW
DW
BED
BATH
LIVING
SMKE
DEN
ENTRY
DINING
SMKE
BED
CP - CONTROL PANEL DW - DOOR/WINDOW SENSOR PIR - MOTION DETECTOR SMKE - SMOKE DETECTOR CO - CARBON MONOXIDE DETECTOR GB - GLASS BREAK SENSOR PAD - WIRELESS KEYPAD ES - EXTERNAL SIREN
SIDE AND MAIN GARAGE DOOR SENSORS HAVE EXIT/ENTRY DELAY
KITCHEN
CP
CO
GB
DW
PAD
DW
DW
DW
DW
SMKE
GARAGE
PIR
DW
Example Security System Floor Plan
7
Burglary Protection
Sensor Status
The security system constantly monitors all of the sensors attached to the protected doors and windows in your home or business. The Control Panel knows if each protected door or window is open or closed. The open or closed condition of the protected doors and windows is called the “sensor status”.
For maximum security, all the doors and windows on the premises should be closed when leaving the building. In some cases, such as when using the security system for protection when staying at home, it may be desirable to leave some protected doors or windows open. The system uses “bypasses” to resolve the open door or window conditions. Before the system can be armed, all protected doors and windows must be closed or bypassed. Bypasses and their two types are
explained in detail on the next page.
Checking that All Sensors are Closed
In most cases, you will be arming the security system with all of the sensor-protected doors and windows closed. The Control Panel provides several easy ways to verify that all the sensor-protected doors and windows are closed before arming the system.
The
button will light green if all sensors are closed. The button will not be lit if ANY
sensors are open.
The SECURITY button on the display’s Home Screen will light green if all sensors are closed. The SECURITY button will be lit orange if ANY sensors are open.
The ARM button on the display’s Security Screen will light green if all sensors are closed. The ARM button will be lit orange if ANY sensors are open.
The ARM button on the display’s Menu Screen will light green if all sensors are closed. The ARM button will be lit orange if ANY sensors are open.
Viewing Each Sensor’s Status
The Control Panel will also show you which sensor-protected doors and windows are open. Your installer has programmed descriptive names for each sensor-protected door and window. The Control Panel’s color display will show the names of which door and windows are open.
The top area of the display on the Home, Security, and Menu Screens will list any sensors that are currently open.
Pressing the STATUS button will also display a list of all open sensors along with general system status and alerts.
THE STATUS BAR SHOWS THE SYSTEM MODE AND WHAT SENSORS ARE OPEN
THE ARM BUTTON ON THE SECURITY AND MENU SCREENS LIGHTS GREEN WHEN ALL SENSORS ARE CLOSED. THE ARM BUTTON WILL LIGHT ORANGE WHEN ARE OPEN
THE HOME BUTTON LIGHTS GREEN WHEN ALL SENSORS ARE CLOSED. THE HOME BUTTON WILL NOT BE LIT WHEN SENSORS ARE OPEN
ANY SENSORS
ANY
8
Burglary Protection
Sensor Bypassing
Before the system can be armed, all protected doors and windows must be closed or bypassed. The system uses “bypasses” to resolve open sensors on protected doors or windows before arming the system. When a sensor is bypassed, the system ignores that the door or window is open. There are two types of sensor bypasses available: forced and manual.
In some cases (such as when using the security system for protection when staying at home) it may be desirable to leave some sensor-protected doors or windows open. Temporarily bypassing a sensor for this use is called “force bypassing”. Force bypasses are automatically removed when the
system is disarmed.
Sensor bypassing is also sometimes used when a sensor is requiring service. A sensor’s magnet might be missing, or an external switch contact connected to a sensor might be faulty, causing the sensor to be detected as “open” by the Control Panel. In these conditions, you may need to schedule a service call with your qualifi ed alarm service technician to repair or replace the troubled sensor. If the security system needs to be armed before the sensor can be serviced, the sensor can be “manually bypassed” so the rest of the system can be armed. Manual bypasses remain in
place until they are manually removed.
NOTE: Bypassed sensors offer no protection and cannot cause an alarm. Use bypass
if you want to arm your system with one or more sensors open and intentionally unprotected.
Force Bypassing Sensors
If any sensors are open when the ARM button is pressed, the Control Panel will display the bypass sensor screen. When the system is disarmed, the force bypassed sensors will be returned to normal.
With one or more sensors open, press 1. ARM from the Security or Menu Screen.
Press 2. BYPASS ALL to force bypass the open sensors.
Enter a User Code (unless 3. “Quick Bypass” has been set by the installer) to activate the bypass and continue to the Arming Screen.
Force Bypass Sensors Screen
Manual Bypassing or Un-bypassing Sensors
In case one or more sensors needs to be manual bypassed because of a trouble condition, or have their manual bypass removed, use the following steps.
Press 1. MENU, TOOLBOX, then BYPASSED SENSORS.
Enter a User Code.2.
Press the name(s) of the sensors to 3. bypass or un-bypass. The bypass symbol will display for the manually bypassed sensors. Bypasses to all listed sensors can be removed by pressing UNBYPASS ALL.
Press 4. OK.
Manual Bypass Sensors Screen
9
Burglary Protection
Stay Mode
Stay Mode is for arming the system when people will be staying on the premises. Stay Mode arms the sensor-protected perimeter doors and windows while not arming the interior motion sensors or other interior doors. This allows the premises to be occupied while the system is partially armed. Stay Mode is used mostly for arming the system during the evening hours after everyone is inside and no one is expected to enter or leave.
When the system is armed in Stay Mode, you can move about the premises without triggering the burglary alarm. All the interior burglary protection is off. But, if a sensor-protected perimeter door or window is opened, an alarm will occur.
Entry Delay
Certain sensors, such as the front door, can be setup by your installer to have a delay before triggering an alarm. This provides a way for an authorized person returning to enter using a predetermined door and disarm the system before an alarm is triggered. When arming the system in Stay Mode, an “Entry Delay” option check box is shown on the Control Panel’s Arming Screen. Normally this option check box is checked, so the programmed delay doors allow time for disarming the system after the door is opened. Un-checking this option box removes the delayed alarm trigger from all sensor­protected doors programmed for delay, causing those entrances to instantly trigger the alarm if they are opened in Stay Mode.
Quick Exit
A programmable option, called “Quick Exit” may be displayed on the Security Screen while the system is armed in the Stay Mode. Pressing the Quick Exit button starts a timer to allow someone to exit or enter through a sensor-protected door programmed for delay without having to disarm the entire system. When the delay timer runs out, the system returns to the normal Stay Mode.
The Quick Exit option can be turned on or off by your installer, refer to the “Installer Set Options” section of this manual to see which options have been set for your system.
10
Burglary Protection
Arming to Stay Mode
Use Stay Mode to arm the system when anyone will be staying home. Stay Mode normally has an Entry Delay so someone with a User Code can re-enter without causing an alarm.
Close all protected perimeter doors and windows before arming.1.
Verify that the 2. to arm. The SECURITY button and ARM button on the display will also be green when all sensors are closed.
From the Security Screen, or the Menu Screen, press 3. ARM.
If there are any open door or window sensors, the Bypass Screen will appear. Close • all the sensors displayed or press BYPASS ALL to force bypass the displayed sensors. NOTE: BYPASSED SENSORS WILL NOT BE ABLE TO TRIGGER AN ALARM.
To bypass sensors, you will need to enter a User Code unless • the installer has set the system for “ Quick Bypass”.
On the Arming Screen, one check box option can be used with Stay Mode.4.
If no one is expected to re-enter, the system can be armed without an Entry • Delay. All perimeter doors will trigger the alarm instantly. To arm with all perimeter doors as instant, un-check the ENTRY DELAY option button.
Press 5. STAY to arm the system.
To arm the system, you may need to enter a User Code if your • installer has turned off the system’s “ Quick Arming” feature.
The system will arm and show the 6. Exit Delay counting down. When the Exit Delay expires, the system is fully armed in the Stay Mode.
button on the Control Panel is lit green indicating that the system is ready
The Security Screen
The Arming Screen
Quick Exit ButtonEntry Delay Check Box
11
Burglary Protection
Away Mode
Away Mode is for arming the system when everyone will be leaving the premises. Away Mode arms all sensor-protected perimeter doors and windows, interior motion sensors, interior glass break sensors, and any other sensor-protected interior doors. The premises must be unoccupied while the system is armed. Away Mode is typically used for arming the system during the daytime hours in a residential installation, and non-business hours in a commercial installation.
When the system is armed in Away Mode, you cannot move about the premises without triggering the burglary alarm (if the system is installed with interior protection). An alarm will occur if any sensor-protected door or window is opened, or interior motion or glass breakage is detected (if motion or glass breakage detectors are installed in your system).
Exit and Entry Delays
Certain sensors, such as the front door, can be setup by your installer to have a delay before triggering an alarm. This provides a way for an authorized person to exit and reenter the premises without triggering an alarm. The “ Exit Delay” allows time to leave after arming the system. The “ Entry Delay” allows time to disarm the system before an alarm is triggered.
When arming the system in Away Mode, an “Entry Delay” option check box is shown on the Control Panel’s Arming Screen. Normally this option check box is checked, so the programmed delay doors allow time for disarming the system after the door is opened. Un-checking this option box removes the delayed alarm trigger from all sensor-protected doors programmed for delay, causing those entrances to instantly trigger the alarm if they are opened in Away Mode. With the Entry Delay disabled, the system will have to be remotely disarmed with a wireless key fob before entering.
Silent Exit
An option for silencing the exit delay beeps is also available when arming the system in Away Mode. On the Control Panel’s Arming Screen, a “Silent Exit” option check box is shown. Checking this option will stop the Control Panel from sounding beeps during the Exit Delay time and double the length of the Exit Delay. The option resets when the system is disarmed.
Quick Exit
A programmable option, called “Quick Exit” may displayed on the Security Screen while the system is armed in the Away Mode. Pressing the Quick Exit button starts a timer to allow someone to exit or enter through a sensor-protected door programmed for delay without having to disarm the entire system. When the delay timer runs out, the system returns to the normal Away Mode. This option can be turned on or off by your installer, refer to the “Installer Set Options” section of this manual to see which options have been set for your system.
NOTE: If interior sensors are installed in the system in certain areas, do not violate
those sensors when using the Quick Exit feature in Away Mode.
Auto Stay Mode
The system may have been programmed by the installer for “Auto Stay Mode”. If this option is on and the system is armed in Away Mode, if an exit/entry delay sensor is not triggered before the Exit Delay expires (no one left the premises), the system automatically arms in Stay Mode instead of Away Mode. Refer to the “Installer Set Options” section of this manual to see which options have been set for your system.
12
Burglary Protection
Arming to Away Mode
Use the Away Mode to arm the system when everyone will be leaving the home. The Away Mode normally has an Entry Delay so someone with a User Code can re-enter without causing an alarm. Interior and perimeter sensors are armed in the away Mode.
Close all sensor-protected doors and windows before arming.1.
Verify that the 2. to arm. The SECURITY button and ARM button on the display will also be green when all sensors are closed.
From the Security Screen, or the Menu Screen, press 3. ARM.
If there are any open door or window sensors, the Bypass Screen will appear. Close • all the sensors displayed or press BYPASS ALL to force bypass the displayed sensors. NOTE: BYPASSED SENSORS WILL NOT BE ABLE TO TRIGGER AN ALARM.
To bypass sensors, you will need to enter a User Code unless • the installer has set the system for “ Quick Bypass”.
On the Arming Screen, two check box options can be used with Away Mode.4.
The system can be armed without an Entry Delay. All perimeter doors will trigger the alarm instantly. The system will have to be disarmed with a wireless key fob. To arm with all perimeter doors as instant, un-check the ENTRY DELAY option button.
When the SILENT EXIT button is checked, the Exit Delay will be doubled and the beeps that normally sound during exit will not sound.
Press 5. AWAY.
To arm the system, you may need to enter a User Code if your • installer has turned off the system’s “ Quick Arming” feature.
The system will arm and show the 6. Exit Delay counting down. When the Exit Delay expires, the system is fully armed in the Away Mode.
When the system is armed in the Away Mode, beeps will sound during • the Exit Delay (faster beeps during the last 10 seconds). To silence these beeps, press SILENCE (the Exit Delay will also be extended).
button on the Control Panel is lit green indicating that the system is ready
The Security Screen
The Arming Screen
The Bypass ScreenExit Delay Timer & Silence Button
13
Burglary Protection
Disarming the System
To stop the Control Panel from triggering burglary alarms, the system will need to be disarmed. Disarming turns off the burglary detection part of the system for sensors that are not 24-hour sensors. Disarming also stops any type of alarm in process.
The system should be disarmed from Stay Mode before exiting the premises. The system should be disarmed from Away Mode before or while entering the premises. When disarming from the Control Panel or wireless keypad, you will need to enter a valid User Code. A wireless key fob can also be used to disarm the system. Entering a User Code is not required when disarming with a wireless key fob.
An important feature of the Control Panel is its ability to warn you if an alarm has occurred while you were away. If an alarm was triggered while the system was armed, the alarm siren will run for a preset length of time then stop. When you enter to disarm the system, instead of sounding the normal Entry Delay beeps, the Control Panel will sound repeated fast beeps to warn you that alarm has occurred while you were away.
WARNING: WHEN ENTERING THE PREMISES TO DISARM THE SYSTEM, IF YOU HEAR FAST REPEATED BEEPS INSTEAD OF THE NORMAL ENTRY DELAY BEEPS, USE EXTREME CAUTION!!! AN INTRUDER MAY STILL BE PRESENT INSIDE THE BUILDING!!! WAIT OUTSIDE AND USE A CELL PHONE TO CALL A FRIEND, NEIGHBOR, OR LAW ENFORCEMENT FOR ASSISTANCE.
The Security Screen (System Armed)
Disarm Code Screen
Disarming from Stay Mode
The system should be disarmed from Stay Mode before exiting the premises.
From the Home Screen, press the 1. SECURITY button.
From the Security Screen, or the Menu Screen, press 2. DISARM.
The Disarm Code Screen will display. The left side of the screen shows any events that have 3. occurred while the system was armed.
Enter a valid User Code to disarm the system.4.
In case you press a wrong key, the CLEAR button erases the entire entry. Press CANCEL if you do not want to disarm at this time.
Disarming from Away Mode
The system should be disarmed from Away Mode while entering the premises.
Enter the premises through a designated Entry Delay sensor-protected door.1.
The Disarm Code Screen will display and the Entry Delay beeps will sound. The left side of the 2. screen shows any events that have occurred while the system was armed.
Enter a valid User Code to disarm the system.3.
In case you press a wrong key, the CLEAR button erases the entire entry. Press CANCEL if you do not want to disarm at this time. (An alarm will occur!)
14
Loading...
+ 36 hidden pages