INSPECTION
INSTALLATION
After removing the unit from the packaging, clean the interior and exterior surfaces of the unit with soap and water and a rinse with clean water. Do not use chlorinated cleaners on the surfaces as they can cause corrosion.
This unit is designed for indoor use only. Be sure to locate the unit where the floor can support the weight of the unit and product installed inside of it. The refrigeration system located at the bottom right of the unit requires free air access for proper operation. Allow a minimum of seven (7) inches between the back of the cabinet and the wall. Do not locate the unit next to heat generating equipment or in direct sunlight.
Confirm that the proposed electrical outlet has the correct voltage, frequency and current carrying capacity for the requirements of the unit. This information is noted on the data plate on the inside left wall of the unit. The unit should be isolated on a circuit. Do not use an extension cord to get power to the unit. Improper electrical installations will void the compressor warranty. To prevent shock and fire, be sure the unit is properly grounded.
Local health codes may require that the unit be sealed to the floor with an NSF approved silicone sealant if it is not on legs or casters. After the unit is set in its desired location, simply apply a bead of sealant around the base of the unit and smooth it out.
The product dividers are packaged inside the unit. The product dividers are shipped installed. They can be relocated to your desired position by using the extra bushings located inside the cabinet. The dividers are spring loaded. Push the divider towards the back of the cabinet to release it from the front bushings then swing the front to one side and remove from the rear bushings. Reverse this procedure to re-install in a new location.
1 09/15 Rev. L 143593
The cap catcher is also shipped inside the cabinet. The cap catcher is to be installed on the right front of the cabinet using the two mounting screws on the cabinet and the two keyhole slots on the back of the cap catcher. Loosen the screws and slide the cap catcher over them. Leave the screws loose so the cap catcher can be removed for emptying.
OPERATION AND MAINTENANCE
This cooler is designed to maintain your product temperature within the most desirable range of +34°F to +38°F. You can expect this temperature with the proper temperature control setting and in a normal environment. It is important to remember that when the product is delivered, it must be placed inside the cooler as soon as possible to avoid excessive warm up. If this happens, it may take many hours for the temperature to be reduced to the desirable range.
The temperature controller is located on the inside back wall of the unit. Turn the control clockwise for cooler temperatures and counterclockwise for warmer temperatures. Allow the unit several hours to respond to temperature control adjustments.
When loading the cabinet with product, do not block the air flow path at the back. Blocking the air flow may decrease performance. Maintain clearance between the contents and air duct for best per f or manc e.
This equipment is intended for the storage and display of non-potentially hazardous bottled or canned products only.
Cleaning
Beginning with the initial installation, the interior surfaces of the cabinet should be periodically cleaned with a solution of warm water and baking soda. This solution will remove any odors from spillage that has occurred. The exterior of the cabinet should also be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or mild soap solution. Do not use chlorinated cleaners on any surfaces.
Note: do not use stainless steel cleaners or other solvent-based chemicals on the plastic parts (door handle or trim strips) as they can cause failure. Use mild soap and warm water on plastic parts.
The product dividers can be cleaned in a sink with a mild soap solution and a soft bristled brush.
Periodically the unit should be emptied and cleaned out. There is a drain i n the floor of the cabinet that drains to a drain hose on the back of the cabinet in the compressor compartment. Be sure to use this drain line for cleaning out the cabinet interior.
2 09/15 Rev. L 143593
Condenser Coil
·
Prior to cleaning the condenser coil disconnect the unit from power. Periodic cleaning of the condenser coil will aid the heat transfer of the refrigeration system and increase its efficiency. To accomplish this, remove the lower front grill from the cabinet. The condenser coil is located behind the grill. Use a soft bristled brush to remove any dirt particles that are on the fins of the condenser coil. Use a vacuum cleaner or compressed air to remove the loosened particles. Replace the front grill and reconnect the unit to power. Failure to clean the condenser coil can lead to performance loss and compressor failure.
TROUBLESHOOTING
Problem Remedy
· Check the power cord and make sure it is plugged in and has power.
Compressor will not start
· Check the temperature controller. If it is in the “OFF” position, turn it clockwise to set a desired temperature.
· Move the unit from direct sunlight.
· Move the unit away from heating devices.
Poor performance
Unit noisy
Condensation on cabinet exterior and/or floor
· Install the unit in a well ventilated place, with at least 2 inches of clearance on all sides.
· Clean the condenser if heavy dust is collected.
· Clear contents from blocking the inside air duct.
· Check the temperature controller for correct setting.
· Check the covers and be sure they are completely closed.
· Install the unit on a level solid surface.
· Maintain 2 inches of clearance from the wall.
· Check for loose parts or mounting.
· Keep the tubing free from any contact to avoid rattle.
Reduce humidity where the unit is installed.
· Check the drain line to make sure it is not disconnected inside the cabinet and it drains into the drain pan in the compressor area.
3 09/15 Rev. L 143593