NORITAKE-ITRON GU96X8M-K612C5 technology data

p
Dot Graphic VFD Module GU96X8M-K612C5
r
p
y
q 96 x 8 High Brightness Dot Graphic Displa q Single 12V DC Supply q Large 5x7 ASCII & European Font q RS232 Asynchronous Serial Interface q 64 Selectable Multi Drop Addresses q Transformerless PSU (patent pending) q Low Profile Construction
19.3
153.4
The module includes the VFD glass, VF drivers and microcontrolle with refresh RAM, character generation, interface logic and patented transformerless DC/DC converter. The RS232 serial interface accepts 9600 or 19200 baud rates with optional parity bit. The module features a low profile design with numerous custom options available including special fonts and commands. Modules can be connected to a multi dro
192.0
200.0
Body height 3.9mm max + Plunger height 1.1mm
ELECTRICAL SPECIFICATION
Parameter Symbol Value Condition
Supply Voltage VCC 12.0VDC +/- 10% GND=0V Supply Current ICC 250 mA typ. VCC =12V RS232 Input VsIL / VsIH -24V max / +24V max VCC =12V Reset Input ViL/ViH 0.8VDC max / 2.0VDC min VCC =12V
OPTICAL & ENVIRONMENTAL SPECIFICATION Parameter Value
Display Area (X xYmm) 153.35 x 12.55 Dot Size/Pitch (XxY mm) 1.35 x 1.35 / 1.6 x 1.6 Luminance 800 cd/m² Min. Colour of Illumination Blue-Green (505nm) Operating Temperature Storage Temperature Operating Humidity
-20°C to +70°C
-40°C to +85°C 20 to 80% RH @ 25°C
Optical filters can provide violet, red, yellow, blue & green output.
SOFTWARE COMMANDS Hex Command
10 Software Reset to power on state 11 Write Mode toggles overwrite / scroll 12 Write Direction toggles increment / decrement 13 Display On/Off. Data is retained 14 Display Invert. Toggle negative image 15 + xx Absolute Column Set from 00H – 7FH 16 + xx Relative Column Set by 00H - 7FH 17 + len + data Graphic Data Write 1 bytes per column, D7 top 18 Clear Character Buffer with 16 ASCII spaces 19 + data Write to Character Buffer for display effect 1A + effect Display Effect – fade, wipe, scroll, dissolve 1C + macro + len + data Store Macro E0H – FFH in EEPROM 1D + delay Delay Macro – pause for up to 3 seconds 1E + 1E + 1E + FE Clear Macros from EEPROM 1E + 1E + 1E + FF Stop Macro if in a loop 1E + 1E + 1E + adr Address Select 00H – 3FH for active module 20 - DF Character Write ASCII font. E0 - FF Run Macro – execute user defined macro 60 + dh + dl Send Hexadecimal code instead of binary
The user can send non printable command codes 10H-1EH as hexadecimal. Prefix the code using character 60H. Example: `15`3F = Position column 64.
Macro E0 is run at power on.
ut impedance of the RS232 is 4K7ohms.
The in
address system.
12.55
7.48
4.0
8.0
PL2
1.6
CHAR ACTER SET - 5X7 Font
Character 60H is used as a hexadecimal prefix, but can be displayed with a repeat send.
Data is shown in hexadecimal and sent in binary. e.g. FF = 11111111 Bin Address ‘adr’ = 00 - 3F. Setting ‘adr’ to 00 activates all modules. Column position X = 00 – 7F. The communication settings and address can be set using the three switches on the rear of the module. Default communication is 9600,n,8,1. The display effects command allows curtain dissolve, scroll and fade. Software and font set are copyright Noritake Itron Corporation 2002
27.0
21.0
3.0
Dimensions in mm & subject to
tolerances.
Mounting holes 3.5mm dia.
PL2
Pin Signal Description
1 VCC 12V Supply 2 RXD RS232 received data 3 VCC 12V output loop 4 NP No pin for polarization 5 /RST CMOS 5V level Reset Input. Active low 6 GND 0V Supply
Detailed specification, software commands and interface timing
are available on request.
Subject to change without notice.
IUK Doc. No. 03876 Iss.3
10 May 02
CONTACT
Noritake Sales Office Tel Nos
Nagoya Japan: +81 (0)52-561-9867
Canada: +1-416-291-2946
Chicago USA: +1-847-439-9020
Munchen (D): +49 (0)89-3214-290
Itron UK: +44 (0)1493 601144
Rest Europe: +49 (0)61-0520-9220
www.noritake-itron.com