Dot Graphic VFD Module GU96X8M-K612C5
q 96 x 8 High Brightness Dot Graphic Displa
q Single 12V DC Supply
q Large 5x7 ASCII & European Font
q RS232 Asynchronous Serial Interface
q 64 Selectable Multi Drop Addresses
q Transformerless PSU (patent pending)
q Low Profile Construction
19.3
153.4
The module includes the VFD glass, VF drivers and microcontrolle
with refresh RAM, character generation, interface logic and
patented transformerless DC/DC converter. The RS232 serial
interface accepts 9600 or 19200 baud rates with optional parity bit.
The module features a low profile design with numerous custom
options available including special fonts and commands. Modules
can be connected to a multi dro
192.0
200.0
Body height 3.9mm max + Plunger height 1.1mm
ELECTRICAL SPECIFICATION
Parameter Symbol Value Condition
Supply Voltage VCC 12.0VDC +/- 10% GND=0V
Supply Current ICC 250 mA typ. VCC =12V
RS232 Input VsIL / VsIH -24V max / +24V max VCC =12V
Reset Input ViL/ViH 0.8VDC max / 2.0VDC min VCC =12V
OPTICAL & ENVIRONMENTAL SPECIFICATION
Parameter Value
Display Area (X xYmm) 153.35 x 12.55
Dot Size/Pitch (XxY mm) 1.35 x 1.35 / 1.6 x 1.6
Luminance 800 cd/m² Min.
Colour of Illumination Blue-Green (505nm)
Operating Temperature
Storage Temperature
Operating Humidity
-20°C to +70°C
-40°C to +85°C
20 to 80% RH @ 25°C
Optical filters can provide violet, red, yellow, blue & green output.
SOFTWARE COMMANDS
Hex Command
10 Software Reset to power on state
11 Write Mode toggles overwrite / scroll
12 Write Direction toggles increment / decrement
13 Display On/Off. Data is retained
14 Display Invert. Toggle negative image
15 + xx Absolute Column Set from 00H – 7FH
16 + xx Relative Column Set by 00H - 7FH
17 + len + data Graphic Data Write 1 bytes per column, D7 top
18 Clear Character Buffer with 16 ASCII spaces
19 + data Write to Character Buffer for display effect
1A + effect Display Effect – fade, wipe, scroll, dissolve
1C + macro + len + data Store Macro E0H – FFH in EEPROM
1D + delay Delay Macro – pause for up to 3 seconds
1E + 1E + 1E + FE Clear Macros from EEPROM
1E + 1E + 1E + FF Stop Macro if in a loop
1E + 1E + 1E + adr Address Select 00H – 3FH for active module
20 - DF Character Write ASCII font.
E0 - FF Run Macro – execute user defined macro
60 + dh + dl Send Hexadecimal code instead of binary
The user can send non printable command codes 10H-1EH as hexadecimal.
Prefix the code using character 60H. Example: `15`3F = Position column 64.
Macro E0 is run at power on.
ut impedance of the RS232 is 4K7ohms.
The in
address system.
12.55
7.48
4.0
8.0
PL2
1.6
CHAR ACTER SET - 5X7 Font
Character 60H is used as a hexadecimal prefix, but can be displayed with a
repeat send.
Data is shown in hexadecimal and sent in binary. e.g. FF = 11111111 Bin
Address ‘adr’ = 00 - 3F. Setting ‘adr’ to 00 activates all modules.
Column position X = 00 – 7F.
The communication settings and address can be set using the three
switches on the rear of the module. Default communication is 9600,n,8,1.
The display effects command allows curtain dissolve, scroll and fade.
Software and font set are copyright Noritake Itron Corporation 2002
27.0
21.0
3.0
Dimensions in mm & subject to
tolerances.
Mounting holes 3.5mm dia.
PL2
Pin Signal Description
1 VCC 12V Supply
2 RXD RS232 received data
3 VCC 12V output loop
4 NP No pin for polarization
5 /RST CMOS 5V level Reset Input. Active low
6 GND 0V Supply
Detailed specification, software
commands and interface timing
are available on request.
Subject to change without notice.
IUK Doc. No. 03876 Iss.3
10 May 02
CONTACT
Noritake Sales Office Tel Nos
Nagoya Japan: +81 (0)52-561-9867
Canada: +1-416-291-2946
Chicago USA: +1-847-439-9020
Munchen (D): +49 (0)89-3214-290
Itron UK: +44 (0)1493 601144
Rest Europe: +49 (0)61-0520-9220
www.noritake-itron.com