NORITAKE-ITRON GU112x16G-7806 technology data

Dot Graphic VFD Module GU112x16G-7806
x
x
w
x
x
q 112x16 Dot Graphic (2x16 characters) q Single 5V Supply q High Brightness Blue Green Display q Operating Temp -40°C to +85°C q 3 Multi Sized Fonts
The module includes the Vacuum Fluorescent Display glass, VF drivers and micro-controller ICs with refresh RAM, character generator and interface logic. The 4/8 bit parallel & serial bi-directional interfaces are 5V TTL/CMOS compatible. The command set is LCD compatible with extended graphic functions.
q 4/8 Bit Parallel LCD & Serial Interfaces
Pin 1
12.5
CON1 CON2
52.5
Pin 1
75.0
80.0
78.0
ELECTRICAL SPECIFICATION Parameter Symbol Value Condition
Power Supply Voltage VCC 5.0VDC +/- 5% GND=0V Power Supply Current ICC 250mADC typ. VCC=5V Logic High Input VIH 0.8VDC min. Vcc max. VCC=5V Logic Low Input VIL 0VDC min 0.6VDC max. VCC=5V Logic High Output VOH 3.5VDC min. Vcc max. IOH=-10uA Logic Low Output VOL 0VDC min 0.6VDC max. IOL =4mA
OPTICAL and ENVIRONMENTAL SPECIFICATIONS
Parameter Value
Display Area (XxY mm) 52.5 x 11.45 Dot Size/Pitch (XxY mm) 0.33 x 0.575 / 0.47 x 0.725 Luminance 700 cd/m2 Typ. Colour of Illumination Blue-Green (Filter for colours) Operating Temperature Storage Temperature Operating Humidity (non condensing)
SOFTWARE COMMANDS
Instruction R/W RS D0-D7
Clear Display L L 01H Cursor Return Home L L 02H Entry Mode Set L L 04H-07H Display ON/OFF L L 08H-0FH Cursor Shift Left L L 10H Cursor Shift Right L L 14H Display Shift Left L L 18H Display Shift Right L L 1CH Select 4 bit interface L L20H + optional luminance data Select 8 bit interface L L 30H + optional luminance data Set CG RAM Addr. L L40H-7FH Set DD RAM Addr. L L 80H-E7H Read BUSY/Addr. H L 00H-FFH D7 Busy = High Read Data from RAM H H 00H-FFH Set Graphic Cursor L L F0H + xpos + ypos Set Area Commands
Set Font / Spacing L L F2H + font style Set RS Low 0FH Serial Comms. only Read Data FEH Serial Comms. only Read Cursor Position FFH Serial Comms. only
LL LH LH LH LH LH LH
-40°C to +85°C
-40°C to +85°C 20 to 80% RH @ 25°C
F1H + x1 + y1 + x2 + y2 + cmd
here cmd 49H = Invert Area 46H = Fill Area 43H = Clear Area 4FH = Set Outline Bo 6FH = Clear Outline Bo + others for graphic data write
SERIAL INTERFACE–CON2
Pin Async SPI
15V 5V 2NC SCK 3RXD/SS
Dimensions in mm & subject to
tolerances.
Mounting holes 3.2mm dia.
4NC SIN 50V 0V
11.45
31.0
36.0
6NC SOUT 7TXDNC 8 /RES /RES
10.375
2.5
2.5
8.7 ma
1.6
2.0 ma
CHARACTER SET
5x7 & 10x14 Font LCD Font International Font
Mini Font
FONT SELECTION
J3 Font
Open LCD (default)
Link International
SERIAL/PARALLEL SELECTION
J8 Interface
Open Parallel (default)
Link Serial
SERIAL MODE
J9 J10 Configuration
O O SPI / Clock Serial (def)
L O Async 9600,N,8,1
O L Async 19200,N,8,1
L L Async 38400,N,8,1
Copyright 2002 Noritake Itron Corp. Japan
9MB MB 10 HB HB
PARALLEL INTERFACE - CON1
Pin Sig Pin Sig
1 GND 2 VCC 3 NC* 4 RS 5 R/W (/WR) 6 E (/RD) 7D08D1
9D210D3 11 D4 12 D5 13 D6 14 D7
*/RESET = Jumper J6.1 & J6.2 BUSY = Jumper J6.2 & J6.3
NC = Do Not Connect
The default font can be changed by J3. Other fonts can then be selected by software command.
CONTACT
Noritake Sales Office Tel Nos
Nagoya Japan: +81 (0)52-561-9867
Canada: +1-416-291-2946
Chicago USA: +1-847-439-9020
Munchen (D): +49 (0)89-3214-290
Itron UK: +44 (0)1493 601144
Rest Europe: +49 (0)61-0520-9220
www.noritake-itron.com
Subject to change without notice.
IUK Doc Ref:04111 Iss:1 25Oct02
NORITAKE ITRON VFD MODULES 112 x 16 Dot Graphic
Software Commands GU112x16G-7806
SOFTWARE COMMANDS
Instruction Data Format (RS = 1) Description
UDF Write 00H – 0FH Write user defined character 0-7 to the current cursor location on the display. Data Write
(40us – LCD compatible mode) (250us – Graphic mode)
Instruction Data Format (RS = 0) Description
Display Clear
(150ms)
Cursor Home
(400ms)
Entry Mode
(40ms)
Display Control
(50us)
Cursor Shift Left
(40us)
Cursor Shift Right
(40us)
Display Shift Left
(150us)
Display Shift Right
(150us)
Select 4 bit interface
(40ms)
Select 8 bit interface
(40ms)
Set CG Address
(40us)
Set DD Address
(40us)
Set Graphic Cursor
(40us)
Set Area
(40us + 500us[cmd byte])
Set Font
(40us)
*Note1
*Note2
*Note3
*Note3
Instruction Data Format Additional Serial Data Commands
Set RS Low 0FH Set the RS line low for the following byte only. Used in serial communications only. Read Data FEH Read data at current cursor position. This command is used with serial communications only. Read Cursor Position FFH Read current cursor position. This command is used with serial communications only.
Notes: - 1. When display shift is enabled, the data write busy time can increase by 150us.
2. If the cursor is enabl ed, busy times can increase by 20us.
3. After these commands are executed, the cursor will be disabled and any character data will be written to the display only, and not the DD RAM. Any subsequent LCD compatible command wi ll re-enable the cursor and allow for DD RAM writing.
GRAPHICAL DATA WRITES
X1, Y1
DATA
DIRECTION
Vertical Data & Horizontal
Movement
00H – FFH Write data to the display. In normal (LCD compatible) mode of operation, data is written to the display data
01H Fills all locations in the display data (DD) RAM with 20H (blank character). The address counter is set to 0 in
02H The address counter is set to 0 in the DD RAM. Any display offset (using the display shift command) is
04H – 07H Bit 1 is used to select the direction of the address counter on each data read or write. If set to ‘1’, the address
08H-0FH Bit 2 is used to enable or disable the display. If this bit is set to ‘0’ the VFD’s power supply is turned off to
(DD RAM) or character generator (CG RAM). When using the graphical data commands (F0H, F1H & F2H), data is written direct to the display and is not stored in DD RAM. Data write busy times will increase when using the graphic functions.
the DD RAM. The address counter is set to increment on each data read/write. Any display offset (using the display shift command) is removed.
removed.
counter is incremented. If set to ‘0’, the address counter is decremented. Bit 0 enables the display to shift on each data read/write. If this bit is set to ‘ 1’, the display is shifted with the cursor. The display shift direction depends upon the address counter direction (bi t1). If this is set to increment, the display is shifted left, if the address counter is set to decrement, the display is shifted right.
reduce power consumption. Bit 0 enables the flashing block cursor.
10H Shift the cursor position (address counter) one position to the left.
14H Shift the cursor position (address counter) one position to the right.
18H Shift the display left, one character position.
1CH Shift the display right, one character position.
20H + lum Enables 4-bit communi cations. Data is received on DB4-DB7 only. Two writes are required to send one data
30H + lum Enables 8-bit communications. Data is received on DB0-DB7.
40H – 7FH Set the character generator address (CG RAM). All written data is placed within the user definable character
byte. The most significant nibble should be sent first. The lum value sets the displays brightness, 00H = full brightness, 01H = 75%, 02H = 50% & 03H = 25%.
The lum value sets the displays brightness, 00H = full brightness, 01H = 75%, 02H = 50% & 03H = 25%.
area.
80H – E7H Set the display data address (DD RAM). 80H - 8FH = top line. C0H - CFH = bottom line.
*Note3
F0H + xpos + ypos Set the absolute cursor position. xpos = 0 – 111, ypos = 0 – 15.
F1H + x1 + y1 + x2 + y2 + cmd Area Commands: - ‘I’ - invert area. ‘F’ – fill area. ‘C’ = clear area. ‘O’ – set outline. ‘o’ – clear outline.
F2H + font Select font type, font size and font spacing.
Co-ordinates should be written with RS line set hi gh.
‘H’ – write horizontal graphical data with horizontal cursor movement. ‘V’ – write vertical graphical data with horizontal cursor movement. ‘h’ – write horizontal graphical data with vertical cursor movement.
All area commands should be proceeded with the area co-ordinates. X1 X2 left top X2 Y2 bottom right Graphical data should immediately follow the ‘H’,’h’,’V’ and ‘v’ commands. Co-ordinates, command and graphical data should be written with RS line set high.
Font commands: - ‘A’ or ‘a’ = proportional 64 character mini-font.
Font command should be written with RS line set high.
‘v’ – write vertical graphical data with vertical cursor movement.
‘B’ = 5x7 LCD compatible font with Katakana characters. ‘C’ = 10x14 LCD compatible font with Katakana characters. ‘b’ = 5x7 international font with European characters. ‘c’ = 10x14 international font with European characters. ‘1’ = set the inter-character pixel spacing to 1 pixel. ‘2’ = set the inter-character pixel spacing to 2 pixels.
CONTACT
MSB
X1, Y1
MSB
DATA
DIRECTION
Vertical Data & Ver tical
Movement
X1, Y1
MSB
Horizontal Data & Horizontal
DATA
DIRECTION
Movement
X1, Y1
MSB
Horizontal Data & Vertical
Movement
DATA
DIRECTION
Noritake Sales Office Tel Nos
Nagoya Japan: +81 (0)52- 561-9867
Canada: +1-416-291-2946
Chicago USA: +1-847-439-9020
Munchen (D): +49 (0)89-3214-290
Itron UK: +44 (0)1493 601144
Rest Europe: +49 (0)61-0520-9220
www.noritake-itron.com
Subject to change without notice Doc Ref: 004107 Iss.2 15OCT02
NORITAKE ITRON VFD MODULES GU112x16G-7806
Loading...