Norgren 11-104 User Manual

See Section ALE-24 for Accessories
ALE-8-6
Littleton, CO USA Phone 303-794-2611 www.norgren.com
11-104
Pilot regulators are used to control the outlet
pressure of a pilot operated regulator (ordered separately)
location in the compressed air system; pilot operated regulator is installed at any point without regard to accessibility
Feedback pilot regulator provides superior pressure
regulation under changing flow demands where changes in flow demand are not sudden or cyclic.
Constant bleed feature provides maximum sensitivity
to system changes
Relief feature allows reduction of downstream
pressure when the system is dead-ended
Feedback Pilot Regulator
1/4" Po rt S ize
ISO Symbols
11-104 Feedback Pilot Regulator
with Pilot Operated Regulator
Outlet pressures can be adjusted to pressures in excess or, and less than, those specified.Do not use these units to control pressures outside of
the specified ranges.
Ordering Information Model listed is relieving, constant bleed, 5 to 100 psig (0.3 to 7 bar) outlet pressure adjustment range
, with
PTF ports.
Port Size Type Model Weight lb (kg) Pressure psig (bar) 1/4" PTF Feedback Pilot 11-104-001 3.38 ( 1.53) 5-105 (.3-7) 1/4" PTF Feedback Pilot 11-104-002 3.38 ( 1.53) 50-250 (3-17)
Feedback Pilot Regulator Warning
The feedback line must sense the pilot operated regulator outlet pressure and must be connected before turning on the air supply. If the feedback line is not connected, the pilot operated regulator outlet pressure will rapidly increase to the inlet pressure when the adjusting knob on the pilot regulator is turned clockwise.
11-104 Pilot Regulator
ALE-8-7
All Dimensions in Inches (mm)
Littleton, CO USA Phone 303-794-2611 www.norgren.com
Technical Data
Fluid: Compressed air Inlet pressure range: 10 psig (0.7 bar) to 400 psig (27.6 bar) maximum*
* For best performance, inlet pressure should be at least 10 psig (0.7 bar) greater than the desired
regulated pressure, but must not exceed the specified maximum.
Operating temperature: 0 to 175°F (-20° to 80°C) **
** Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Maximum bleed rate at 50 psig (3.5 bar) outlet pressure:
0.25 scfm (0.12 dm3/s)
Maximum bleed rate occurs under dead-end (no flow) conditons.
Pilot ports: 1/4" PTF Feedback port: 1/8" PTF Materials
Body, bonnet: Zinc Valve seat: Brass Valve ball: Stainless steal Elastomers: Nitrile
3.18 (81)
6.16 (157)
3.25 (83)
3.13 (80)
0.56
(14)
Service Kits
Type Part number 11-104 1970-11
Service kit contains diaphragm, valve pin, valve springs, valve seat, valve ball, and all o-rings.
Panel mounting hole diameter: 1.06" (27 mm) Maximum panel thickness:0.38" (10 mm)