See Section ALE-24 for Accessories
ALE-9-4
Littleton, CO USA Phone 303-794-2611 www.norgren.com
11-008
● Designed for systems that require pressure
regulation at an inaccessible location.
● A pilot regulator (ordered separately) controls the
outlet pressure of the pilot operated regulator.
● For general purpose applications, order an R72 or
R07 pilot regulator.
● For precision applications, order an R40, R41, or 11-
104 pilot regulator.
● Constant bleed feature provides quick maximum
sensitivity to system changes
Pilot Operated Regulator
1/2", 3/4" and 1" Por t Sizes
ISO Symbols
With Conventional
Pilot Regulator
With Feedback
Pilot Regulator
Alternative Models
Threads Substitute
PTF 0
ISO G parallel 8
ISO G Rc 9
11
★
0 8
★ ★ ★
--
Pilot Operated Regulator Ordering Information
Models listed include relieving diaphragm and PTF threads.Also order a pilot regulator.
Port Size Model Flow*scfm (dm3/s) Weight lb (kg)
1/2" 11-008-130 70 (33) 1.6 (0.7)
3/4" 11-008-009 110 (52) 4.9 (2.2)
1" 11-008-110 180 (85) 4.6 (2.1)
* Typical flow with a conventional pilot at 150 psig (10.3 bar) inlet pressure, 100 psig (6.9 bar) set pressure and a droop of less than 5 psig (0.35 bar) from set.
With 150 psig (10 bar) Gauge Substitute
1/2" main ports 142
3/4" main ports 021
1" main ports 122
Feedback Pilot Regulator Warning
The feedback line must sense the pilot operated regulator outlet pressure
and must be connected before turning on the air supply. If the feedback line
is not connected, the pilot operated regulator outlet pressure will rapidly
increase to the inlet pressure when the adjusting knob on the pilot
regulator is turned clockwise.
11-008 Pilot Operated Regulator
ALE-9-5
All Dimensions in Inches (mm)
Littleton, CO USA Phone 303-794-2611 www.norgren.com
Technical Data
Fluid: Compressed air
Inlet pressure range: 10 psig (0.7 bar) to 400 psig (27.6 bar)*
* For best performance, inlet pressure should be at least 10 psig (0.7 bar) greater than the desired
regulated pressure, but must not exceed the specified maximum.
Operating temperature: 0° to 175°F (-20° to 80°C)**
** Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Typical flow with a conventional pilot regulator at 150 psig (10.3 bar) inlet pressure,
100 psig (6.9 bar) set pressure, and a droop of less than 5 psig (0.35 bar) from
set:
1/2" ports: 70 scfm (33 dm
3
/s)
3/4" ports: 110 scfm (52 dm3/s)
1" ports: 180 scfm (85 dm
3
/s)
Maximum bleed rate at 50 psig (3.5 bar) outlet pressure: 0.34 scfm (0.16 dm3/s)†
†Maximum bleed rate occurs under dead-end (no flow) conditions.
Port sizes
Main: 1/2", 3/4", 1"
Gauge: 1/8"
Pilot: 1/4"
Thread type
Main and gauge ports: PTF, ISO G, or ISO Rc
Pilot port: PTF with PTF main ports, ISO G with ISO G and ISO Rc main por ts
Materials
Body: Zinc
Bonnet: Aluminum
Bottom plug:
1/2", 3/4 ports: Brass
1" ports: Glass filled nylon
Valve: Brass
Elastomers: Nitrile
Port Size A B C D
1/2" 3.34 3.38 1.50 3.30
(85) (86) (38) (84)
3/4", 1" 4.91 4.63 1.69 4.36
(125) (118) (43) (111)
Service Kits
Type Part number
1/2" ported units 695-01
3/4", 1" ported units 696-01
Kit contains diaphragm, valve, and all o-rings.
Typical Performance Characteristics
PORT SIZE: 1/2
"
PILOT SPRING RANGE: 5 to 100 psig (0.3 to 6.9 bar)
INLET PRESSURE: 150 psig (10.3 bar)
FLOW CHARACTERISTICS WITH CONVENTIONAL PILOT
01020 304050 dm3/s
AIR FLOW
0 20 40 60 80 100 120 scfm
OUTLET PRESSURE
8
6
4
2
0
bar
120
100
80
60
40
20
0
psig
PORT SIZE: 3/4
"
PILOT SPRING RANGE: 5 to 100 psig (0.3 TO 6.9 bar)
INLET PRESSURE: 150 psig (10.3 bar)
FLOW CHARACTERISTICS WITH CONVENTIONAL PILOT
0 20 40 60 80 100 dm3/s
AIR FLOW
0 40 80 120 160 200 240 scfm
OUTLET PRESSURE
8
6
4
2
0
bar
120
100
80
60
40
20
0
psig
FLOW CHARACTERISTICS WITH CONVENTIONAL PILOT
0 25 50 75 100 125 dm3/s
AIR FLOW
0 50 100 150 200 250 300 scfm
OUTLET PRESSURE
8
6
4
2
0
bar
100
80
60
40
20
0
psig
PORT SIZE: 1
"
PILOT SPRING RANGE: 5 to 100 psig (0.3 TO 6.9 bar)
INLET PRESSURE: 150 psig (10.3 bar)
A
D
C
B