4.
Install a pressure gauge in a gauge port on the 11-008, or to the application point downstream of the 11-008. Do not connect the gauge to the pilot pressure line, as this pressure is not the same as the 11-008 outlet pressure. Locate the gauge next to the pilot regulator. Plug unused gauge ports.
5. Install a general purpose filter upstream of the regulator.
ADJUSTMENT
1. Before applying inlet pressure to regulators, turn pilot regulator adjustment counterclockwise to remove all force on regulating spring.
2. Apply inlet pressure, then turn pilot regulator adjustment clockwise to increase and counterclockwise to decrease pressure setting.
3. Always approach the desired pressure from a lower pressure. When reducing from a higher to a lower setting, first reduce to some pressure less than that desired, then bring up to the desired pressure.
DISASSEMBLY
1. Regulator can be disassembled without removal from air line.
2. Shut off inlet pressure to pilot regulator and to the 11-
008. Reduce pressure in inlet and outlet lines to zero.
3. Turn pilot regulator adjustment counterclockwise to remove all force on regulating spring.
4. Disassemble in general accordance with the item numbers on exploded view. Do not remove valve seat (13) unless replacement is necessary. Remove o-ring (7) using a hook shaped tool, taking care not to damage o­ring seating surfaces and valve seat (13).
CLEANING
1. Clean parts with warm water and soap
2. Rinse and dry parts. Blow out internal passages in body (15) with clean, dry compressed air.
3. Inspect parts. Replace those found to be damaged.
ASSEMBLY
1. Lubricate o-rings and surfaces in contact with o-rings with a light coat of good quality o-ring grease.
2. Assemble the unit as shown on the exploded view
3. Torque Table Item Torque Inch-Pounds (Nm) 13
(Valve seat - if removed)
15 to 20 (1.7 to 2.3) 8 (Bottom plug) Hand tighten 1 (Screw) 1/2" regulators - 45 to 55 (5.1 to 6.2)
3/4" & 1" regulators - 50 to 70 (5.6 to 7)
in a diagonal sequence
WARNING
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data.
If outlet pressure in excess of the regulator pressure setting could cause downstream equipment to rupture or malfunction, install a pressure relief device downstream of the regulator. The relief pressure and flow capacity of the relief device must satisfy system requirements.
The accuracy of the indication of pressure gauges can change, both during shipment (despite care in packaging) and during the service life. If a pressure gauge is to be used with these products and if inaccurate indications may be hazardous to personnel or property, the gauge should be calibrated before initial installation and at regular intervals during use.
Before using these products with fluids other than air, for non industrial applications, or for life-support systems consult Norgren.
TECHNICAL DATA
Fluid: Compressed air Inlet pressure range: 10 psig (0.7 bar) to 400 psig
(27.6 bar). For best performance, inlet pressure should be at least 10 psig (0.7 bar) greater than the desired regulated pressure, but must not exceed the specified maximum.
Operating temperature: 0° to +175°F (-20° to +80°C).
Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C).
Typical flow with a conventional pilot regulator at 150
psig (10.3 bar) inlet pressure, 100 psig (6.9 bar) set pressure, and a droop of less than 5 psig (0.35 bar) from set:
1/2" ports: 70 scfm (33 dm
3
/s)
3/4" ports: 110 scfm (52 dm
3
/s)
1" ports: 180 scfm (85 dm
3
/s)
Maximum bleed rate at 50 psig (3.5 bar) outlet
pressure: 0.34 scfm (0.16 dm
3
/s). Maximum bleed
rate occurs under dead-end (no flow) conditions.
Port sizes:
Main: 1/2", 3/4", 1" Gauge: 1/8" Pilot: 1/4"
Thread type:
Main and gauge ports: PTF, ISO G, or ISO Rc Pilot port: PTF with PTF main ports, ISO G with
ISO G and ISO Rc main ports
Materials:
Body: Zinc Bonnet: Aluminum Bottom plug:
1/2", 3/4 ports: Brass
1" ports: Glass filled nylon Valve: Brass Elastomers: Nitrile
REPLACEMENT ITEMS
Repair kit - items circled on exploded view
1/2" ported regulators............................................695-01
3/4" and 1" ported regulators..................................696-01
INSTALLATION
1. Shut off air pressure. Install regulators in air line -
upstream of lubricators and cycling valves.
at any angle.
install the 11-008 pilot operated regulator as close as
possible to the device being serviced.
install the pilot regulator at any convenient, accessible
location.
2. Use pipe thread sealant on male threads only when making the following pipe connections. Do not allow sealant to enter interior of regulator.
Connect inlet and outlet air lines to 11-008 main ports
with air flow in direction of arrow on body.
Connect inlet and outlet air lines to the main ports of a
relieving type pilot regulator. The inlet port of the R40 and R41 is marked IN, and the outlet port is marked OUT. The direction of air flow thru the 11-104 pilot is indicated by an arrow on the bottom of the body.
Connect the outlet of the pilot regulator to the pilot port
in the top of the 11-008 bonnet. This is the pilot pressure line.
3.Special Instructions for a Feedback Pilot:
Connect one end of the feedback line to the feedback port on the pilot regulator. The feedback port on the R41 is marked FDBK. The 11-104 has two 1/8" PTF feedback ports. Plug the unused feedback port. Connect the other end of the feedback line to a gauge port on the 11-008 or, if maximum precision pressure regulation is desired, to the application point downstream of the 11-008. Keep the feedback line as short as possible and unrestricted. Use 1/4" or 3/8 " OD copper tube for the feedback line. Plug unused gauge ports.
Warning - Feedback Pilot Regulators
Norgren manufacturers two feedback pilot regulator types (the R41 and the 11-104). Use the R41, the 11-104-002, or the 11-104-003 feedback pilot regulator to control outlet pressures greater than 100 psig (7 bar). Use the Norgren 11-104-001 feedback pilot regulator to control outlet pressures at or less than 100 psig (7 bar).
The feedback line must sense 11-008 outlet pressure and must be connected before turning on air pressure. If the feedback line is not connected, 11­008 outlet pressure will rapidly increase to inlet pressure when the feedback pilot adjusting knob is turned clockwise.
IM-422.250
(2/02)
Replaces NIP-205
Pilot Operated Regulator
© Norgren 2002
Figure 2. Feedback Pilot Installation
Figure 1. Conventional Pilot Installation
a subsidiary of IMI plc
SUPPLY AIR
SUPPLY AIR
PILOT OPERATED REGULATOR
CONVENTIONAL PILOT REGULATOR
PILOT PRESSURE LINE
OUTLET
1
2
5
6
16
15
14
13
12
11
10
9
8
SUPPLY
AIR
SUPPLY AIR
PILOT OPERATED REGULATOR
AIR
FEEDBACK PILOT REGULATOR
3
4
7
17
FEEDBACK LINE
PILOT PRESSURE LINE