See Section ALE-24 for Accessories
ALE-5-14
Littleton, CO USA Phone 303-794-2611 www.norgren.com
11-002
● Large diaphragm provides accurate and quick
response to changing flow demands and line
pressure
● Floating valve pin provides positive valve seating
● Balanced valve minimizes effect of variations in inlet
pressure on outlet pressure
● Standard relieving models allow reduction of
downstream pressure when the system is
dead-ended
Pressure Regulator
1/4", 3/8", 1/2" Port Sizes
Port Size Model Number Flow†scfm (dm3/s) Weight lbs (kg)
1/4" 11-002-013 110 (52) 1.9 (0.86)
3/8" 11-002-037 110 (52) 1.9 (0.86)
1/2" 11-002-061 260 (123) 2.0 (0.91)
Ordering Information. Models listed have PTF threads, T-bar adjustment, relieving diaphragm, and 5 to 125 psig (0.3 to 8.5 bar) outlet
pressure adjustment range*.
† Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and 15 psig (1 bar) droop from set.
*Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.Do not use these units to control pressures outside of the specified ranges.
Alternative Models
Threads Substitute
PTF 0
ISO G parallel 8
ISO G Rc 9
0
★
-
★
★ ★★ ★
2
- -
1
1
Option Substitute
Handwheel adjustment 8C
Screw adjustment 8B
Mounting bracket assembled to unit 1A
Threaded bonnet for panel mounting, hand wheel adjustment 2A
Threaded bonnet for panel mounting, T-bar adjustment 2B
Threaded bonnet for panel mounting, screw adjustment 2C
Outlet Pressure Adjustment Range*
5 to 50 psig (0.3 to 3.5 bar)
Port Size Relief Type Gauge Substitute
1/4" Non-relieving Without 003
1/4" Relieving Without 015
3/8" Non-relieving Without 027
3/8" Relieving Without 039
1/2" Non-relieving Without 051
1/2" Relieving Without 063
1/4" Non-relieving With 009
1/4" Relieving With 021
3/8" Non-relieving With 033
3/8" Relieving With 045
1/2" Non-relieving With 057
1/2" Relieving With 069
Outlet Pressure Adjustment Range*
5 to 125 psig (0.3 to 8.5 bar)
Port Size Relief Type Gauge Substitute
1/4" Non-relieving Without 001
1/4" Relieving Without 013
3/8" Non-relieving Without 025
3/8" Relieving Without 037
1/2" Non-relieving Without 049
1/2" Relieving Without 061
1/4" Non-relieving With 007
1/4" Relieving With 019
3/8" Non-relieving With 031
3/8" Relieving With 043
1/2" Non-relieving With 055
1/2" Relieving With 067
Outlet Pressure Adjustment Range*
5 to 250 psig (0.3 to 17 bar)
Port Size Relief Type Gauge Substitute
1/4" Non-relieving Without 005
1/4" Relieving Without 017
3/8" Non-relieving Without 029
3/8" Relieving Without 041
1/2" Non-relieving Without 053
1/2" Relieving Without 065
1/4" Non-relieving With 011
1/4" Relieving With 023
3/8" Non-relieving With 035
3/8" Relieving With 047
1/2" Non-relieving With 059
1/2" Relieving With 071
* Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.Do not use these units to control pressures outside of the specified ranges.