Ultimus™ I–II High Precision
Fluid Dispensers
Quick Start Guide
Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com.
Easy 13-Step Setup
Follow these steps to get your Ultimus ready
for operation.
Unpack the Unit / Warranty
• Unpack the unit.
• Now is a good time to activate your Five* Year No-Fault Warranty.
Register the warranty online at www.nordsonefd.com/warranty/five-no-fault..
*Two years in Asia
1
Install Barrel Holder
• Remove barrel holder sleeve from holder.
• Loosen the 6 mm screw from T-nut.
• Slide T-nut into left or right panel of workstation slot,
positioning as shown.
2
Connect Power
• Tighten 6 mm screw, securing holder to workstation panel.
• Insert barrel holder sleeve.
• Loosen screw from wire hose holder T-nut.
• Slide T-nut into any workstation slot.
• Tighten screw to secure wire hose holder to workstation.
• Connect the power plug to the power pack. The unit is shipped
with a USA-compatible plug and three international plugs. Attach
the correct plug to match local power outlets.
1
1
2
3
5
6
7
8
3
4
2
7
6
8
4
5
Power cord
3
• Connect the power cord to the back of the Ultimus.
• Connect the power cord to your local power source.
• Press the power button on the front panel.
Connect Foot Pedal
The Ultimus is normally operated using the foot pedal
provided.
• Plug the foot pedal into the back of the Ultimus.
Foot pedal
Arrow on top
4
Connect Air Input
NOTE: Clean, dry, filtered factory air is required to meet warranty. If your air
supply is not filtered, order the 5-micron filter regulator (P/N 7002002).
• Push one end of the air input hose into the input fitting on the back of the
5
• Connect the other end of the air input hose to your plant air supply.
For all Ultimus units: Set plant air supply within 5.5 to 7.0 bar (80 to 100 psi).
NOTE: Arrow on cord
connector faces up
Ultimus.
Input air
Connect Air Output
• Push in the EFD adapter assembly provided into the front of the Ultimus and
twist to lock.
6
Attach Syringe Barrel & Tip
• Secure an EFD syringe barrel filled with your fluid to the adapter
assembly.
• Replace tip cap with an EFD precision dispense tip.
See the Operating Manual for syringe barrel filling techniques.
TIP
7
Front panel output air