Performus I Series Fluid Dispensers
Quick Start Guide
™
Electronic pdf files of Nordson EFD
manuals are also available at
www.nordsonefd.com

Unpack the unit. Now is a good time to activate
the warranty online at www.nordsonefd.com/
warranty/dispensers/one.
1. NOTE: Clean, dry filtered air is required
to meet warranty. If your air supply is
not filtered, order the 5-micron filter /
regulator (P/N 7002002).
Turn the air regulator adjustment knob
to zero (0).
Connect one end of the air input hose
to the Performus™; connect the other
end to the plant air supply. Set the
plant air supply between 5.5–7.0bar
(80–100 psi).
2. Attach the plug that matches the local
power outlet to the power pack.
Connect the power cord to the
Performus and insert the plug into the
local power source.
Press the power button on the front
panel.
3 12
3. Connect the foot pedal or optional finger
switch.
4. Attach a filled Nordson EFD syringe
barrel to the adapter assembly and snap
the safety clip closed. Replace the tip
cap with a Nordson EFD dispense tip
and place the syringe barrel in the barrel
stand.
5. Insert the adapter assembly into the
quick-connect fitting on the front of the
Performus and twist to lock.
5
4
2
2 3