Nordson EFD 740V-HL Operating Manual

740V-HL Dispense Gun
Operating Manual
Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com
740V-HL Dispense Gun
Introduction
The 740V-HL (#7021209) hand-operated dispense gun is a rugged industrial lever-actuated fluid dispensing valve. The valve incorporates a quick-change fluid body for fast and easy cleaning. The fluid inlet fitting for 1/4" OD feed tubing and an assortment of dispensing tips are included.
1. Install the feed tube from the fluid reservoir to the inlet fitting and tighten the compression nut to secure. The fluid body may be rotated up to 1/2 turn to locate the fluid inlet fitting in a comfortable position.
2. Apply air pressure to the fluid reservoir. Start with a low setting of 1.4 bar (20 psi). If using a Nordson EFD fluid reservoir, refer to the operating manual for further instructions.
3. Install an appropriate size dispensing tip on the outlet tip adapter. Use large tips for high viscosity materials and small tips for low viscosity.
Typical System Setup
#7002002 5-micron filter / regulator for clean, dry filtered factory air
For dispensing with cyanoacrylates, order #7016548 with coalescing filter
4. Press the hand lever to begin fluid flow. Release the lever to stop fluid flow.
5. To achieve the desired flow, change the size of the dispensing tip or adjust the reservoir fluid pressure.
Shutoff valve
#7020105
Hand-lever
valve stand
#7010004
accommodates a one
2 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
1.0 liter tank
pound bottle
Loading...
+ 2 hidden pages