740V-HL Dispense Gun
Introduction
The 740V-HL (#7021209) hand-operated dispense gun is a rugged industrial lever-actuated fluid dispensing valve. The
valve incorporates a quick-change fluid body for fast and easy cleaning. The fluid inlet fitting for 1/4" OD feed tubing and an
assortment of dispensing tips are included.
Getting Started
1. Install the feed tube from the fluid reservoir to the inlet
fitting and tighten the compression nut to secure. The
fluid body may be rotated up to 1/2 turn to locate the
fluid inlet fitting in a comfortable position.
2. Apply air pressure to the fluid reservoir. Start with a
low setting of 1.4 bar (20 psi). If using a Nordson EFD
fluid reservoir, refer to the operating manual for further
instructions.
3. Install an appropriate size dispensing tip on the outlet
tip adapter. Use large tips for high viscosity materials
and small tips for low viscosity.
Typical System Setup
#7002002
5-micron filter / regulator for
clean, dry filtered factory air
For dispensing with
cyanoacrylates, order #7016548
with coalescing filter
4. Press the hand lever to begin fluid flow. Release the
lever to stop fluid flow.
5. To achieve the desired flow, change the size of the
dispensing tip or adjust the reservoir fluid pressure.
Shutoff valve
#7020105
Hand-lever
valve stand
#7010004
accommodates a one
2 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
1.0 liter tank
pound bottle