Introduction
The 725-HL (#7020888) dispense gun is a rugged, industrial, hand-operated fluid dispensing valve. The valve incorporates a quick-change fluid body for fast and easy maintenance. Included with the valve are two fluid inlet fittings for 1/4" OD or 3/8" OD feed tubing and an assortment of dispensing tips.
1. Install the fluid fitting into the inlet port 1. Use the 1/4" fitting for low to medium viscosity fluids and the 3/8" fitting for high viscosity fluids.
2. Install the appropriate size feed tube on the inlet fitting and tighten the compression nut to secure. The position of the inlet fitting can be adjusted. Loosen the fluid body retaining nut fluid body to the desired position, and tighten the retaining nut.
3. Apply air pressure to the fluid reservoir. Start with a low setting of 1.4 bar (20 psi). If using a Nordson EFD fluid reservoir, refer to the operating manual for further instructions.
2
, rotate the
4. Install an appropriate size dispensing tip on the outlet tip adapter materials and small tips for low viscosity.
5. Pull the trigger to begin fluid flow. Release the trigger to stop flow.
6. To achieve the desired flow, change the size of the dispensing tip or adjust the reservoir fluid pressure.
3
. Use large tips for high viscosity
3
Closed
Open
21
2 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.