Intellisys Throttling SoftShut (TSS) Valve
Quick-Start Guide
TSS DN-63, DN-80, DN-100, DN 160, DN-200 and DN-250
Unpacking & Handling
Use care when unpacking an Intellisys SoftShut Valve. Flange surfaces can sc ratch easily. SoftShut Valves are
manufactured primarily from St ainless Steel, and are very heavy. A static-safe, particle-free work surface is
recommended. There is no need to remove parts during installation or inspect i on.
Check The Package Contents:
• Intellisys Throttling SoftShut (TSS) Valve
NOTE: IQ-series controllers are mounted directly t o the TSS
• This Quick-Start Guide
Serial Label
A Serial Label on the TSS Valve shows the mode l number and serial number of your product.
Warranty
Nor-Cal Intellisys Controllers and valves are warranted against defects and material workmanship for a per iod of
12 months after the date of shipment to the buyer. For complete warranty and Int ellectual Property details,
please refer to the full manual.
Pre-Installation Functionality Check
Refer to the diagrams & photographs on the back of this sheet for locations of the items that follow.
WARNING: The valve plate movement presents a severe pinching/crush ing
hazard. Please keep fingers, hands and other objects away from the valve
opening and associated moving parts.
Connect Power and Valve Cables
Connect the APC controller to the valve motor with a Nor-Cal TBV-CRD series cable. (NOTE: IQ-series valves
do not require a valve cable connection, as the motor is integrated into the controller.) Connect the controll er to
an appropriate power source. Toggle the power switch (if applicable) or apply DC power from your sour ce.
Initialize the Valve
From the tool software, send the appropriate initialization command to begin initialization. During Init i alization,
the valve will complete a 30-second init ialization sequence during which the valve plate will cycle bac k-and-forth
several times. The valve will eventually stop in the open position, unles s specified otherwise by the firmware.
Open/Close Testing
Verification of the system communications can be done by toggling the “O PEN / CLOSE” switch (if availabl e) on
the controller front panel, or sendi ng the appropriate command from the tool software. If the valve does not
operate as described, please contac t Nor-Cal technical support.
Obtaining Complete Manuals
To download complete manuals for I ntellisys TSS Valves, please visit www.n-c.com. Click Support, choose
Product Documentation Downloads from the drop-down menu, and pick Downstream Pres su re Control
under Manuals at the left.
Nor-Cal Products, Inc. 1967 South Oregon St., Yreka, CA 96097 USA
LIT-TSS-QSG, 01/2005