Intellisys Throttling Butterfly Valve (TBV) Quick-Start Guide
Covers all Throttling Butterfly Valves (TBV) and Low-Conductance Butterfly Valves (TBZ)

Serial Label

Use care when unpacking an Intellisys Throttling Butterfly Valve. Aluminum surfaces can scratch easil y and Stainless Steel components are heavy. A static-safe, particle-free work surface is recommended. There is no need to remove parts during install ation or inspection.
Check The Package Contents:
Intellisys Throttling Butterf ly Valve (TBV) NOTE: IQ-series controllers are mounted directly t o TBV’s
This Quick-Start Guide
Serial Label
A Serial Label on the bag shows the mode l number and serial number of your product. Additionally, Model, Serial and Date Codes are engraved, and an inspection sticker is affixed to the side of the valve.
Warranty
Nor-Cal Intellisys Controllers and valves are warranted against defects and material workmanship for a period of 12 months after the date of shipment to the buyer. For complete warranty and Intellectual Property details , please refer to the full manual.

Connections & Interfaces

Refer to the diagrams on the back of this s heet for Throttling Butterf ly Valve connections.

Pre-Installation Functionality Check

WARNING: The valve plate movement presents a severe pinching/crushing hazard. Please keep fingers, hands and other objects away from the valve opening and associated moving parts.
Connect Power and Valve Cables
Connect the APC controller to the valve motor with a Nor-Cal TBV-CRD series cable. (NOTE: IQ-series valves do not require a valve cable connection, as the motor is integrated into th e controller.) Connect the controller to an appropriate power source. Toggle the power switch (if applicable) or apply DC power from your source.
Initialize the Valve
From the tool software, send the appropriate initialization command to begin initialization. During Initialization, the valve will complete a 15-second initialization sequence during which the valve plate will cycle back-and-forth several times. The valve will eventually stop in the open position, unl es s specified otherwise by the firmware.
Open/Close Testing
Verification of the system communications can be done by toggling the “OPEN / CLOSE” switch (if available) on the controller front panel, or sendi ng the appropriate command from t he tool software. If the valve does not operate as described, please contac t Nor-Cal technical support.

Obtaining Complete Manuals

To download complete manuals for I ntellisys TBV Valves, please visit www.n-c.com. Click Support, choose Product Documentation Downloads from the drop-down menu, and pick Downstream Pres su re Control and