Printed in Canada Copyright 2010 by NORAC Systems International Inc. Reorder P/N: UC4+CS4-4B-INST Rev C (Case 44 Series Main Lift Kit – 44962D)
NOTICE
NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.
Page 3

TABLE OF CONTENTS

1 INTRODUCTION ................................................................................................................................. 1
2 PARTS LISTS ......................................................................................................................................... 3
3 HYDRAULIC INSTALLATION ........................................................................................................... 6
4 MAIN LIFT VALVE INSTALLATION ................................................................................................ 8
5 ELECTRICAL INSTALLATION .......................................................................................................... 9
6 COMPLETING THE INSTALLATION ............................................................................................. 10
7 ELECTRICAL REFERENCE – CABLE DRAWINGS ....................................................................... 11
7.1 ITEM C16: 44658-46D CABLE UC4 VALVE DT ROLL WITH PIGTAIL ...................................... 11
7.2 ITEM C17: 44658-62 - CABLE UC4 INTERFACE VALVE CS4 ....................................................... 12
Page 4

1 INTRODUCTION

Congratulations on your purchase of the NORAC UC4+ Spray Height Control System. This system is manufactured with top quality components and is engineered using the latest technology to provide operating features and reliability unmatched for years to come.
When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
Please take the time to read this manual completely before attempting to install the system. A thorough understanding of this manual will ensure that you receive the maximum benefit from the system.
YOUR INPUT CAN HELP MAKE US BETTER! If you find issues or have suggestions regarding the parts list or the installation procedure, please don’t hesitate to contact us.
NOTICE:
Every effort has been made to ensure the accuracy of the information contained in this manual. All parts supplied are selected specially to fit the sprayer to facilitate a complete installation. However, NORAC cannot guarantee all parts fit as intended due to the variations of the sprayer by the manufacturer. Please read this manual
in its entirety before attempting installation.
ATTENTION:
When installing the UC4+ Spray Height Control system please be aware that at a point in the installation your sprayer booms will be inoperative until the installation is complete. Any installation procedure
requiring boom movement will need to be done first. Once the hydraulics
have been disconnected you must complete the electrical installation before the booms become operative.
2
Page 5

2 PARTS LISTS

The parts that come with your UC4+ Spray Height Control System are listed in Table 1. The item number on the left side of this table references each part.
Please ensure that all parts in your kit are present before proceeding with your installation.
Table 1: Case 44 Series Main Lift System Parts
Item Part Number Name Quantity
C16 44658-46D CABLE UC4 VALVE DT ROLL WITH PIGTAIL 1
C17 44658-62 CABLE UC4 INTERFACE VALVE CS4 1
H01 44865-48 HYDRAULICS FITTING KIT - CS4 1
H02 44863-38 HOSE ASSEMBLY 122R2-06 156 IN L 6FORX 6FORX90 2
M01 UC4+CS4-4B-INST MANUAL INSTALLATION UC4+ CASE 44 SERIES MAIN LIFT KIT - 44962D 1
V01 44962D VALVE ASSEMBLY EXPANSION DPOC PROP DT 4 BOLT 1
3
Page 6
Table 2: 44865-48 - Hydraulics Fittings Kit Details
Item Part Number Name Quantity
F03 104586 TEE ADAPTER - 6FORX 6MORT 2
F04 44917 MALE ADAPTER - 6MB 6MOR 2
Fitting Name
6 M B - 6 M OR X 90
Example:
SIZE IN
TH'S
1/16 GENDER: MALE OR FEMALE
TYPE: B - ORB J - JIC OR - FLAT FACE P - PIPE
90 SWIVEL
TYPE GENDER SIZE
Picture
° ANGLE
The use of dielectric grease is not recommended on any NORAC electrical connections.
To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Permatex Anti-seize lubricant is preferred, but other similar anti-seize products may be used.
4
Page 7
Figure 1: Hydraulic Components
5
Page 8

3 HYDRAULIC INSTALLATION

WARNING!
The hydraulic system creates very high pressure. Before disconnecting any hydraulic lines ensure all pressure has been bled from the system.
IMPORTANT:
Component failure due to oil contamination is not covered under the UC4+ Spray Height Control system warranty. It is recommended that a qualified technician does the hydraulic installation.
Sprayers with a model year of
2007 and older require the main lift valve to be changed. See Section 4 for instructions on how to do this.
1. Use Figure 1 as a reference for
installing the hydraulics.
2. Install the 6MB 6MOR fitting (F04) into
the A and B ports of the expansion block (Figure 2).
Figure 2: Expansion Block Assembly
3. Remove the four 4MBP plugs from the 2
station valve block.
4. Coat the four o-rings in hydraulic oil
and install them into the expansion block. Ensure the o-rings are seated properly.
5. Attach the expansion block to the 2
station block using the included spring washers and bolts.
6. Tighten the bolts to 31 ft-lbs.
Figure 3: Expansion Valve Final Assembly
6
Page 9
t
7. If the valve block is not already installed
on the sprayer, install it as outlined in the UC4+ Spray Height Control kit installation manual.
8. Attach the straight 6FORX fittings on
the hoses (H02) to the A and B ports on the expansion block. Route the free end of the hoses (H02) to the Case main lift tee, which is located near the sprayer axle.
9. Disconnect the raise hose that runs
from the Case valve block to the main lift tee and install the 6FORX 6MORT (F03) onto the existing Case 6MORT (Figure 4).
10. Connect the NORAC hose (H02) that
is connected to the B port on the NORAC expansion block to the tee fitting F03.
11. Reconnect the hose that runs from the
Case main lift valve block to the main lift tee. This connects onto the tee fitting F03.
12. Disconnect the lower hose that runs
from the Case valve block to the main lift tee
13. Connect the NORAC hose (H02) that
is connected to the A port on the NORAC expansion block to the tee fitting F03.
14. Reconnect the hose that runs from the
Case main lift valve block to the main lift tee. This connects onto the tee fitting
F03.
You must ensure no hydraulic
components will interfere with any sprayer parts or be pulled tight at any time.
Hoses running forward
o Case main lift block
Main Lift Tee
connectors
Hoses running to main lift cylinders
Figure 4: Location of Main Lift Tees (When Looking From Front of Sprayer
towards the Rear)
7
Page 10

4 MAIN LIFT VALVE INSTALLATION

If the sprayer was built prior to model year 2007 then the main lift valve may have to be replaced with a part from your local Case Dealership. If the booms will go up, but not down; the valve will need to be replaced. The Case part number of the required valve is 87558232.
1. Lower the main lift all the way to the
bottom.
2. Turn OFF the sprayer ignition.
3. Loosen the hoses on each side of one of
the main lift cylinders located at the back of the sprayer. This is to remove any pressure from the system.
4. Remove the coils from the main lift
valve, located under the sprayer.
5. Thread the valve out of the valve
housing and thread the new valve in.
6. Reinstall the coils onto the new main lift
valve.
Remove this
nut and the
two coils.
Figure 5: Main Lift Valve Location
8
Page 11

5 ELECTRICAL INSTALLATION

Figure 6: Cable Connections
Cable C16 and C17 are the only
cables included in the kit.
1. Locate the end of the previously
installed valve extension cable. This is at the rear of the sprayer.
2. Disconnect the Case Interface Cable
from the Valve Extension Cable and connect the 6-pin connectors on cable C17 between the cables.
3. Connect the three pin shroud labeled
“Connect to C11” on cable C17 to the free three pin tower on the valve extension cable.
4. Connect cable C16 to the three pin
shroud on cable C17.
5. Connect the 2-pin connector on cable
C16 marked ROLL CCW to the coil on the port side of the valve block.
The port side is the side of the
valve block with the left and right tilt hoses.
6. Connect the 2-pin connector on cable
C16 marked ROLL CCW to the other free coil.
The pigtails on cable C16 are not
used for this installation.
7. Tie up all cabling so that it will not
interfere with any components on the sprayer.
9
Page 12

6 COMPLETING THE INSTALLATION

You can now continue to install the remainder of your UC4+ Spray Height Control System.
If the system is fully installed then refer to the UC4+ Operators Manual Automatic Install with the CS4 type selected.
to run an
10
Page 13

7 ELECTRICAL REFERENCE – CABLE DRAWINGS

7.1 ITEM C16: 44658-46D CABLE UC4 VALVE DT ROLL WITH PIGTAIL
11
Page 14
7.2 ITEM C17: 44658-62 - CABLE UC4 INTERFACE VALVE CS4
12
Page 15
www.norac.ca
NORAC Systems International Inc.
6667 West Old Shakopee Road, Suite 111
Canada
CALL TOLL FREE: 1-800-667-3921
(306)664-6711
SHIPPING ADDRESS:
3702 Kinnear Place
Saskatoon, SK
S7P 0A6
United States
NORAC, Inc.
CALL TOLL FREE: 1-866-306-6722
(952)224-4142
SHIPPING ADDRESS:
Bloomington, MN
55438
Europe
NORAC Europe sarl
(+33) (0)4 26 47 04 42
SHIPPING ADDRESS:
Rue de l’hermitage
01090 Guereins
France
Loading...