Tip on the sensitive skin around the eyes,
especially the area under the eyes.
• Do not use this device on eyebrows.
• Do not use this device on sunburned skin,
open cuts, bruises, blisters, moles or on
raised areas such as scars.
• If you have any skin condition other than
those listed above, like cold sores, herpes,
severe acne, please consult your physician
before using this device.
• Do not use deodorants, lubricants, liquids,
creams, gels, alcohol, water etc. before use.
• Do not allow the thermodynamic wire inside
the Thermicon™ Tip to touch your skin.
• Only use this device for its intended purpose
as described in this manual.
• This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have beensupervised/
instructed and understand the hazards
involved. Children shall not play with the
appliance. Cleaning and user maintenance
shall not be done by children unless they
are older than 8 and supervised. Keep the
appliance and power supply out of reach of
children under 8 years.
• Not intended for animals.
• Keep the appliance dry.
Page 5
CAUTIONS - to reduce the risk of fire, electric shock, etc.
• Do not reach for a device that has fallen into
water while it is plugged in.
• Do not place or store device near water,
liquids, sink or a bathtub.
• This device should never be left unattended
when plugged in.
• Do not use the Thermicon™ Tip if the wire is
bent or damaged in any way.
• Turn off the device before changing the
Thermicon™ Tip.
• Do not use the power supply if the cord or
plug is damaged in any way.
• Do not use this device near, or rest it on,
flammable objects such as paper or cloth,
etc.
• Always unplug the power cord from the
electrical outlet immediately after charging
and before use, cleaning or maintenance.
• This device should only be used with the
supplied power supply.
• Always turn off this device when you have
finished working with it.
• Do not open the outer casing of the unit.
This might harm the unit and it will void any
warranty.
• Caution consult accompanying
documents.
5
Page 6
6
Meet no!no! Hair (Model PRO3)
You are about to experience a totally new approach to hair removal. The no!no!
PRO3 uses new patented Pulsed Thermicon™ technology to deliver a painfree and effective treatment for everyone, including all hair colors and skin
types. But this is science, not magic and you’ll need time, patience and a strong
commitment to the treatment procedure. Read the User Manual and Quick
Guide thoroughly before you start, and if you have more questions, just go to
www.howtonono.com. Soon, you’ll get the smooth, professional, salon-like
results you’ve been waiting for with at-home convenience.
Page 7
7
Treatment Level Button
Statu s
Screen
On/Of f
Button
Power Supply
Connection
Clear panel
Cover
Signal Light
Tip’s S ocket
Posts
Power supply
Buffer
Thermicon™ Tips
no! no! Cleaning Brush
Roller
User Manual
Quick Guide
Page 8
8
Before you no!no!
Get the best results and performance by learning as much as you can before you
no!no!. Below is a brief description about what to expect, what to look out for and how
each of the parts work.
• Track your progress! Before you use
no!no! the first time, study the area you
want to treat. You might even want to
take pictures or choose a small area
and count the hairs. Then, once every 2
weeks, check your progress. After 4-6
weeks, you should be able to see initial
results.
• Aroma therapy – no!no! burns hair and
burnt hair smells. But that’s how you
know its working. Try aromatic candles
or other air fresheners. An after
treatment cream or moisturizer like
no!no! Smooth will help mask the smell
even further. As less hair grows back,
the smell will also decrease.
• Test Run – Before you use no!no! the
first time, and before treating new
areas, always test no!no! on a small
section at the lowest treatment level.
• That feels weird
experience a mild tingling sensation
when they first use no!no!, especially
around sensitive areas. This sensation
will fade away completely after a few
treatments.
• For the sensitive type – If your skin
feels uncomfortable during treatment,
reduce the treatment level and/or take
short breaks after repeatedly gliding on
– Some people
Page 9
any one area.
• Keep it Smooth – When you finish your
treatment, apply a non-alcoholic lotion
or cream like no!no! Smooth to keep
your skin moisturized.
• Patience is a virtue – Initial results
take 4-6 weeks to appear.
• The first 4-6 weeks – For best results,
use no!no! at least 2-3 times a week for
the first 4-6 weeks. You don’t have to
wait for a lot of hair to grow back. Just
1mm of stubble is enough to get the
smooth results you are looking for.
• After the first 4-6 weeks – You may
have noticed that your hair isn’t growing
in as fast or as thick. You can reduce
the treatments to once or twice a week.
• Check the Thermicon™ Tips – Always
make sure the thermodynamic wire
is completely intact before use. If it is
bent or torn, replace it before your next
treatment.
• Clean the Thermicon™ Tips – Clean
the tips frequently during treatment
with the enclosed cleaning brush,
especially when working on long hair.
This will help prolong the life of your
Thermicon™ Tips.
• Stay Safe! Do not use no!no! on
sunburned skin, open cuts, bruises,
blisters, large moles or on raised areas
such as scars.
• Stay Smart! Do not use no!no! on the
genitals, nipples or on and around the
eye.
• Stay protected! Your no!no! warranty
lasts for one year on parts and service.
Keep your receipt.
9
Page 10
10
Before You Start
Charging no!no!
Before using it for the first time, charge no!no! for at least 5 hours.
When charging is complete,
the full batter y icon on the
status screen will flicker
until no!no! is removed
from the power supply.
When recharging is
necessary, the empty
battery icon will flicker.
During charging, the bars
will alternately light up, one
after the other.
Battery Status
Full Charge
Partial Charge
Low Charge
Charge Immediately
Page 11
Skin Preparation
Thoroughly clean and dr y your skin. Do not use no!no! on any area where there
might be residual gels, oils, lotions, deodorant, etc.
Assembly
1. Make sure that no!no! is
charged and the power supply is
disconnected.
2. Remove the cover.
3. Install the Thermicon™ Tip.
11
Page 12
12
• Select the right tip.
Wide Tip
Use the wide tip for large areas
like the arms, legs and back.
Narrow Tip
Use the narrow tip for small, sensitive
areas like the face, nape of the neck
underarms and bikini line.
• Hold no!no! in one hand and the tip of your choice in the other. Make sure the no!no!
logos are facing the same direction. Then line up the posts in the socket with the
holes in the Thermicon™ Tip and gently push into place.
Holes
Posts
Page 13
• Check to make sure the tip is pushed all the way into the socket.
improperly placedproperly placed
When treating facial hair, please see the Facial Hair Tips section.
To remove the Thermicon™ Tip
• Turn off the device.
• Grasp the Thermicon™ Tip by both ends.
• Gently pull out and remove.
13
Page 14
14
4. Turn it On
• Hold the On/Off button down for
a few seconds until the status
screen appears.
5. Adjust the Treatment Level
• For your comfort, there are 3
different treatment levels.
Treatment Level
LowMediumHigh
On/Off button
Status
Screen
Tre atmen t
Level Icon
Page 15
• Press the Treatment Level button to
adjust levels.
Tre atme nt
Level Button
• When first using no!no! or when starting to treat a new area, test no!no! on a
small section of skin using the lowest treatment level.
• For optimal results, raise and work at the highest level possible while still
maintaining comfort.
• If your skin feels hot or uncomfortable at anytime, STOP immediately. Lower
the treatment level and try again.
• The default treatment level is low. When you turn it on again, it will display the
last used treatment level.
15
Page 16
16
Master the no!no! Glide
Crucial to the treatment is the no!no! Glide. To master this technique:
1. Hold no!no! at a
90º angle with the
rollers flat against
the skin.
2. Gently glide no!no! over each section against
the grain of hair growth, with the no!no! logo
in the front.
3. Always glide in a slow, steady, smooth, even motion in one direction. Do not stop in
one place.
Page 17
4. Keep the blue light steady. If it flickers, you may be going too slowly, or too
quickly, adjust your speed accordingly.
5. You may need to go over an area more than once – but don’t over do it, 3-4
passes is enough. If there is more hair left, wait a few minutes and return
to that area if necessar y.
6. Do not press down too hard with the device.
7.If you are treating facial hair, please see the Facial Tips section.
Important Note:
Do not be alarmed when the number of bars
change on the Status Screen. When you first
start to glide, the Status Screen will automatically
switch from the Treatment Level display (q) to
the Thermicon™ Tip status display (w).
Check the icon to determine what information is
being displayed.
q
w
17
Page 18
18
Rounded areas
To work on more difficult areas, go slowly and allow
no!no! to follow the natural cur ve of the body. We
recommend mastering the glide on arms and legs before
moving on to the knees, elbows, face and bikini line.
NOTE: The bikini line may be extra-sensitive to temperature. If it becomes
uncomfortably warm during treatment, lower the treatment level or work on a
different area for a while. Do not go further than the bikini line.
Watch the Light
The signal light by the ThermiconTM Tip will guide you throughout your no!no!
treatment. It lets you know when you are working at the right speed and warns
you if the Thermicon™ Tip is torn, damaged or no longer working. The Signal Light
is only visible while you are gliding the no!no!.
Page 19
When working at the right speed, the light will remain steady. If the light flickers,
adjust your speed accordingly.
MeaningBlueRed
Correct gliding speedOn and steadyOff
No Thermicon™ Tip in socketOffOn
Depleted Thermicon™ Tip OffOn
Damaged Thermicon™ TipOffOn
Incorrect gliding techniqueOffOn
Incorrect gliding speedFlickeringOff
No movementOffOff
Charge no!no!OffFlickering
Table 2: Signal Light
19
Page 20
20
Master the Buffer
You’ve tried everything but your skin still doesn’t feel smooth? Did you remember to
buff? Without buffing, crystallized hair remains in place, giving your skin a prickly
feel. These treated hairs will eventually fall out – but why wait? Buffing exfoliates
your skin, removes crystallized hair and leaves your skin feeling silky smooth.
To Buff:
1. Hold the Buffer by the flaps.
2. Firmly rub the buffer in either
a circular or back and forth
motion over the treated area.
Page 21
Treatment Summary
1. Unplug no!no! from the power supply.
2. Remove the cover.
3. Insert the proper size Thermicon™ Tip for the area you are treating.
4. Push the On/Off button on the top of the unit.
5. Set the treatment level.
6. Glide no!no! over your skin at a 90º angle.
7.Buff after completing each section.
8. Apply a moisturizer.
21
Page 22
22
Thermicon™ Tips
1. To avoid possible malfunction
or harm, make sure to gently
push the Thermicon™ Tip all
the way into the socket.
2. WARNING! Always check the wire in the Thermicon™ Tip before use. Never use
a Thermicon™ Tip if the wire is bent
Bent thermodynamic wireTorn thermodynamic wire
,
torn or damaged in any way.
Page 23
Replace the Thermicon™ Tip:
The Thermicon™ Tip indicator appears as you no!no! and lets you know the present
condition of your Thermicon™ Tip.
Replace the tip…
• When there are no bars on the
status screen.
• When the Thermicon™ Tip icon
flickers.
• If you notice that it is no longer
working efficiently.
• If the wire is damaged in any way.
• When the red Signal Light is on.
Thermicon™ Tip Status
New Slightly Used UsedDepleted
Thermicon™
Tip ico n
23
Page 24
24
Treating Facial Hair
Your face is very sensitive. Take a few minutes and read these impor tant tips for the
safest, most effective treatment.
To view videos of facial hair treatments in action, go to
www.howtonono.com.
Always use the narrow tip and start with the lowest treatment level.
And remember, if there is any discomfort, any where – STOP.
Get comfortable - Practice using the no!no! on your arms or legs before moving to
your face.
TEST
Before you begin, use the instructions below and treat a small, discreet section of
your face to see how your skin reacts to a no!no! facial hair treatment.
If there is any discomfort – STOP.
Page 25
Upper Lip and Mustache Area
When treating the mustache area – start under the nose and work your
way outwards – be careful not to touch your lips or let your skin bunch up
into the tip – hold the skin tight and/or purse your lips inward to create a
straight, smooth surface.
DO NOT allow your lips to come in contact with the Thermicon wire.
DO NOT go over one area excessively.
If there is any discomfort – STOP.
Chin & Jaw Line
Starting from just below the jaw or chin line, glide your no!no! up and
around the curve.
If you need to, pull skin straight and/or purse your lips inward to give
your chin and jaw a straighter, smoother line.
If there is any discomfort – STOP.
25
Page 26
26
Sideburns
Start at the base of the chin and glide upwards following the curve of your face. If you
need to, pull your skin tight and straight for a flat, smooth working surface.
If there is any discomfort – STOP.
IMPORTANTNOTE: The area just below the eye and around the eyelid is especially
sensitive. DO NOT treat this area.
Page 27
Maintenance
Do not use any liquids of any kind to clean the Thermicon™ Tip or rollers.
Thermicon™ Tips
It is important to keep the Thermicon™ Tip free of hair debris. Allowing hair to build
up may cause it to burn out prematurely or malfunction. Check and clean the tip
periodically during each treatment session.
To clean the Thermicon™ Tip:
1. Turn off your no!no!
2. Remove the Thermicon™ Tip
3. Gently brush clean
27
Page 28
28
Rollers
Although not necessary to the performance of no!no!, keeping the rollers clean is all
part of proper maintenance. Use the cleaning brush to remove excess hair and debris
from the rollers.
Brush debris out and away from the socket in order to prevent any par ticles from
falling into the socket.
If any hair or debris fall into the socket, this may
cause no!no! to not function properly. Gently
blow any particles out of the socket before
beginning the next treatment.
Page 29
Troubleshooting
If no!no! does not start when you glide it on the skin:
• Press and hold the On/Off button down for a few seconds again until the Status
Screen appears.
• If it’s not turning on make sure the unit is charged.
• Check the Status Screen while gliding. If no bars appear, replace the Thermicon™
Tip.
• Make sure the Thermicon™ Tip is not bent or torn. Replace it if necessary.
If the device is not working properly, contact your point of purchase for examination
or repair. The no!no! warranty is only valid if no!no! has been used according to the
instructions in this guide. Retain all receipts and original packaging.
29
Page 30
30
Technical Information
Technical Specifications:
• Weight: 104gr
• Physical Dimensions: 120 X 40 X 25mm
(4.7 X 1.6 X 1.0 in)
• Mode of Operation: Continuous
Operating Conditions:
• Temperature: 5°C-30°C
• Humidity: 30%-80% RH
• Power Supply/Battery Charger Rating:
Input 100-240VAC/50-60Hz. 0.2A
Output 8.4VDC 0.5A
Transport and Storage
• Temperature: -20°C to 80°C
• Humidity: 5-95% RH
• Atmospheric pressure: 0.1-1.5 atm.
Electrical Safety:
• Power Supply:
double insulation.
• This appliance is not suitable for use in
the presence of flammable anesthetic
mixture with air or with oxygen or
nitrous oxide.
• The Quality Management System of
Radiancy (Israel) Ltd. complies with the
Quality Management Standard EN ISO
13485:2012.
• Design and technical specifications are
subject to change without notice.
• no!no! complies with the following
international standards and directives:
General Requirements for Basic Safety
and Essential Performance, 3rd Ed.:
IEC60601-1:2005/EN60601-1:2006
Class II equipment –
Page 31
31
Electromagnetic Compatibility: IEC
60601-1-2:2007
• Electromagnetic Compatibility:
EN 60335-1, EN 60335-2-8 and EN
60335-2-23, EN 62233 and FCC Part
15 Subpart B and with Low Voltage
Directive (Electric Safety) LVD:
2006/95/EC and the Electromagnetic
Compatibility Directive 2004/108/EC.
• no!no! requires special precautions
regarding EMC and needs to be
installed and put into ser vice according
to the EMC information provided in this
document.
• FCC, Class B This equipment has
been tested and found to comply with
the limits for a Class B digital device
pursuant to Part 15 of the FCC Rules.
This equipment generates, uses, and
can radiate radio frequency energy and,
if not installed and used in accordance
with the manufacturer’s instruction
manual, may cause interference to
radio communications. These limits
are designed to provide reasonable
protection against harmful interference
in a residential installation. Notice: The
FCC regulations provide that changes
or modifications not expressly approved
by Radiancy Inc. could void your
authority to operate this equipment.
Page 32
32
Symbols on Device
On/Off Switch
CE mark represents the compliance to the European Low Voltage Directive 2 006/95/EC
and the Electromagnetic Compatibility Directive 2004/108/EC.
Protect the environment by not disposing of this product with household waste (2002/96/
EC). Check your local authorit y for recycling advice and facilities (Europe only).
Indicates the need to consult instructions for use.
Manufacturer:
Radiancy (Israel) Ltd.
5 Hanagar Street
Hod Hasharon 4501307
Israel
Manufacturer’s declaration for electromagnetic compatibility (EMC):
Table 1
Guidance and manufacturer's declaration – electromagnetic emissions – no!no!
The no!no! is intended for use in the electromagnetic env ironment specified below; The customer or
the user of the no!no! should assure that it is used in such an environment.
Voltage
fluctuations/
flicker emissions
IEC 61000-3-3
Group 1
Class B
Class A
Complies
The no!no! uses RF energy only for its inter nal function.
Therefore, its RF emissions are ver y low and are not likely to
cause any interference in nearby electronic equipment.
The no!no! is suitable for use in all establishments, including
domestic establishments and those directly connected to
the public low-voltage power supply network that supplies
buildings used for domestic purposes.
33
Page 34
34
Table 2
Guidance and manufacturer's declaration – electromagnetic emissions – no!no!
The no!no! is intended for use in the electromagnetic env ironment specified below; The customer or
the user of the no!no! should assure that it is used in such an environment.
Immunity test
Electrostatic
discharge
(ESD)
IEC 61000-4-2
IE6 0601-1-2
Test level
±6 kV contact
±8 kV air
Compliance level
±6 kV contact
±8 kV air
Electromagnetic environment guidance
Floors should be wood, concrete
or ceramic tile. If floors are
covered with synthetic material,
the rel ative humidity Should be
at least 30%.
Electrical fast
transient /burst
IeC 61000-4-4
Surge
IEC 61000-4-5
±2 kV for power
supply lines
±1 kV for input/output
lines
Class A
±2 kV for power supply
lines not Applicable
Mains power quality should
be that of a typical public lowvoltage power supply net work
that supplies buildings used for
domestic purposes, commercial
or hospital environment.
Page 35
Table 2 Cont.
<5%UT (>95%dip in UT)
Voltage dips,
short
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
Surge
IEC 61000-4-5
NOTE: UT is the a.c. mains voltage prior to application of the test level.
for 0,5 c ycle
40%UT (60%dip in UT)
for 5 cycles <5%UT
70%UT (30%dip in UT)
for 25 cycles <5%UT
<5%UT (>95%dip in UT)
for 5s
3 A/m3 A/m
<5%UT (>95%dip in UT)
for 0,5 c ycle
40%UT (60%dip in UT)
for 5 cycles <5%UT
70%UT (30%dip in UT)
for 25 cycles <5%UT
<5%UT (>95%dip in UT)
for 5s
35
Mains power quality should be that
of a typical public low-voltage
power supply network that
supplies buildings used for
domestic
purposes, commercial or hospital
environment.
Power frequency magnetic fields
should be at levels characteristic
of a typical public low-voltage
power supply network that
supplies buildings used for
domestic purposes, commercial
or hospital environment.
Page 36
36
Table 3
Guidance and manufacturer's declaration – electromagnetic emissions – no!no!
The no!no! is intended for use in the electromagnetic env ironment specified below; The customer or
the user of the no!no! should assure that it is used in such an environment.
Immunity test
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
IE6 0601-1-2
Test level
3 Vrms
150 k Hz to 80
MHz
3 V/m
80 MHz to 2,5
GHz
Compliance
level
3 Vrms
3 V/m
Electromagnetic environment - guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the no!no!,
including cables, than the recommended separation
distance calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
d = 1.17P
d = 1.17P 80 MHz to 800 MHz
d = 2.34P 800 MHz to 2,5 GHz
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmit ter
manufacturer and d is the recommended separation
Page 37
Table 3 Cont.
distance in meters (m). Field strengths from fixed RF
transmitters, as determined by an electromagnetic site
survey, a should be less than the compliance level in
NOTE 1 At 80 MHz and 80 0 MHz, the higher frequenc y range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
a
Field strengths from fixed RF transmitters, such as base stations for r adio (cellular/cordless)
telephones and land mobile radios, amateur r adio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to fixed RF transmitters, an electromagnetic site sur vey should be considered. If the measured field
strength in the location in which the no!no! is used exceeds the applicable RF compliance level above,
the no!no! should be observed to verif y normal operation. If abnormal performance is obser ved,
additional measures may be necessary, such as re-orienting or relocating the no!no!.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
each frequency range d.
Interference may occur in the vicinity of equipment
marked with the following symbol:
37
Page 38
38
Table 4
Recommended separation distances between portable and mobile RF communications equipment
and the no!no!
The no!no! is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the no!no! can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment
(transmit ters) and the no!no! as recommended below, according to the maximum out put power of
the communications equipment.
Separation distance according to frequency of transmitter Meters
[m]
Rated maximum output power
of transmitter
Watts [W]
0.010.120.120.24
0.10.370.370.74
150kHz to 80MHz
d = 1.17P
80MHz to 800MHz
d = 1.17P
800MHz to 2.5GHz
d = 2.34P
Page 39
Table 4 Cont.
11.171.172.34
103.73.77.4
10011.711.723.4
For transmitter s rated at a maximum output power not listed above, the recommended separation
distance d in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmit ter in watts ( W) according
to the transmitter manufacturer.
NOTE 1 At 80 MHz and 80 0 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflec tion from structures objects and people.
39
Page 40
Seeno!no!inaction!
Go to www.howtonono.com
for helpful hints, videos and more.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.