no!no! PRO3 User guide

Page 1
User Manual
LIT-00088 / Rev. B00 / Aug. 2014
Page 2
Page 3
Contents
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Meet no!no! Hair (Model PRO3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Before you no!no! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Treatment Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Thermicon™ Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3
Page 4
4
Safety Instructions
WARNINGS – to reduce the risk of burns or injury
• Do not use this device on the genitals or
nipples.
• Do not use this device with the Thermicon™
Tip on the sensitive skin around the eyes, especially the area under the eyes.
• Do not use this device on eyebrows.
• Do not use this device on sunburned skin,
open cuts, bruises, blisters, moles or on raised areas such as scars.
• If you have any skin condition other than
those listed above, like cold sores, herpes, severe acne, please consult your physician before using this device.
• Do not use deodorants, lubricants, liquids,
creams, gels, alcohol, water etc. before use.
• Do not allow the thermodynamic wire inside
the Thermicon™ Tip to touch your skin.
• Only use this device for its intended purpose
as described in this manual.
• This appliance can be used by children
aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have beensupervised/ instructed and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children unless they are older than 8 and supervised. Keep the appliance and power supply out of reach of children under 8 years.
• Not intended for animals.
• Keep the appliance dry.
Page 5
CAUTIONS - to reduce the risk of fire, electric shock, etc.
• Do not reach for a device that has fallen into
water while it is plugged in.
• Do not place or store device near water,
liquids, sink or a bathtub.
• This device should never be left unattended
when plugged in.
• Do not use the Thermicon™ Tip if the wire is
bent or damaged in any way.
• Turn off the device before changing the
Thermicon™ Tip.
• Do not use the power supply if the cord or
plug is damaged in any way.
• Do not use this device near, or rest it on,
flammable objects such as paper or cloth, etc.
• Always unplug the power cord from the
electrical outlet immediately after charging and before use, cleaning or maintenance.
• This device should only be used with the
supplied power supply.
• Always turn off this device when you have
finished working with it.
• Do not open the outer casing of the unit.
This might harm the unit and it will void any warranty.
• Caution consult accompanying
documents.
5
Page 6
6
Meet no!no! Hair (Model PRO3)
You are about to experience a totally new approach to hair removal. The no!no! PRO3 uses new patented Pulsed Thermicon™ technology to deliver a pain­free and effective treatment for everyone, including all hair colors and skin types. But this is science, not magic and you’ll need time, patience and a strong commitment to the treatment procedure. Read the User Manual and Quick Guide thoroughly before you start, and if you have more questions, just go to www.howtonono.com. Soon, you’ll get the smooth, professional, salon-like results you’ve been waiting for with at-home convenience.
Page 7
7
Treatment Level Button
Statu s
Screen
On/Of f
Button
Power Supply
Connection
Clear panel
Cover
Signal Light
Tip’s S ocket
Posts
Power supply
Buffer
Thermicon™ Tips
no! no! Cleaning Brush
Roller
User Manual
Quick Guide
Page 8
8
Before you no!no!
Get the best results and performance by learning as much as you can before you no!no!. Below is a brief description about what to expect, what to look out for and how each of the parts work.
• Track your progress! Before you use
no!no! the first time, study the area you want to treat. You might even want to take pictures or choose a small area and count the hairs. Then, once every 2 weeks, check your progress. After 4-6 weeks, you should be able to see initial results.
• Aroma therapy – no!no! burns hair and
burnt hair smells. But that’s how you know its working. Try aromatic candles or other air fresheners. An after treatment cream or moisturizer like no!no! Smooth will help mask the smell even further. As less hair grows back,
the smell will also decrease.
• Test Run – Before you use no!no! the
first time, and before treating new areas, always test no!no! on a small section at the lowest treatment level.
• That feels weird
experience a mild tingling sensation when they first use no!no!, especially around sensitive areas. This sensation will fade away completely after a few treatments.
• For the sensitive type – If your skin
feels uncomfortable during treatment, reduce the treatment level and/or take short breaks after repeatedly gliding on
Some people
Page 9
any one area.
• Keep it Smooth – When you finish your
treatment, apply a non-alcoholic lotion or cream like no!no! Smooth to keep your skin moisturized.
• Patience is a virtue – Initial results
take 4-6 weeks to appear.
• The first 4-6 weeks – For best results,
use no!no! at least 2-3 times a week for the first 4-6 weeks. You don’t have to wait for a lot of hair to grow back. Just 1mm of stubble is enough to get the smooth results you are looking for.
• After the first 4-6 weeks – You may
have noticed that your hair isn’t growing in as fast or as thick. You can reduce the treatments to once or twice a week.
• Check the Thermicon™ Tips – Always
make sure the thermodynamic wire is completely intact before use. If it is
bent or torn, replace it before your next treatment.
• Clean the Thermicon™ Tips – Clean
the tips frequently during treatment with the enclosed cleaning brush, especially when working on long hair. This will help prolong the life of your Thermicon™ Tips.
• Stay Safe! Do not use no!no! on
sunburned skin, open cuts, bruises, blisters, large moles or on raised areas such as scars.
• Stay Smart! Do not use no!no! on the
genitals, nipples or on and around the eye.
• Stay protected! Your no!no! warranty
lasts for one year on parts and service. Keep your receipt.
9
Page 10
10
Before You Start
Charging no!no!
Before using it for the first time, charge no!no! for at least 5 hours.
When charging is complete, the full batter y icon on the status screen will flicker until no!no! is removed from the power supply.
When recharging is necessary, the empty battery icon will flicker.
During charging, the bars will alternately light up, one after the other.
Battery Status
Full Charge
Partial Charge
Low Charge
Charge Immediately
Page 11
Skin Preparation
Thoroughly clean and dr y your skin. Do not use no!no! on any area where there might be residual gels, oils, lotions, deodorant, etc.
Assembly
1. Make sure that no!no! is
charged and the power supply is disconnected.
2. Remove the cover.
3. Install the Thermicon™ Tip.
11
Page 12
12
• Select the right tip.
Wide Tip
Use the wide tip for large areas like the arms, legs and back.
Narrow Tip
Use the narrow tip for small, sensitive areas like the face, nape of the neck underarms and bikini line.
• Hold no!no! in one hand and the tip of your choice in the other. Make sure the no!no!
logos are facing the same direction. Then line up the posts in the socket with the holes in the Thermicon™ Tip and gently push into place.
Holes
Posts
Page 13
• Check to make sure the tip is pushed all the way into the socket.
improperly placed properly placed
When treating facial hair, please see the Facial Hair Tips section.
To remove the Thermicon™ Tip
• Turn off the device.
• Grasp the Thermicon™ Tip by both ends.
• Gently pull out and remove.
13
Page 14
14
4. Turn it On
• Hold the On/Off button down for
a few seconds until the status screen appears.
5. Adjust the Treatment Level
• For your comfort, there are 3
different treatment levels.
Treatment Level
Low Medium High
On/Off button
Status
Screen
Tre atmen t Level Icon
Page 15
• Press the Treatment Level button to
adjust levels.
Tre atme nt Level Button
• When first using no!no! or when starting to treat a new area, test no!no! on a
small section of skin using the lowest treatment level.
• For optimal results, raise and work at the highest level possible while still
maintaining comfort.
• If your skin feels hot or uncomfortable at anytime, STOP immediately. Lower
the treatment level and try again.
• The default treatment level is low. When you turn it on again, it will display the
last used treatment level.
15
Page 16
16
Master the no!no! Glide
Crucial to the treatment is the no!no! Glide. To master this technique:
1. Hold no!no! at a
90º angle with the rollers flat against the skin.
2. Gently glide no!no! over each section against
the grain of hair growth, with the no!no! logo in the front.
3. Always glide in a slow, steady, smooth, even motion in one direction. Do not stop in
one place.
Page 17
4. Keep the blue light steady. If it flickers, you may be going too slowly, or too
quickly, adjust your speed accordingly.
5. You may need to go over an area more than once – but don’t over do it, 3-4
passes is enough. If there is more hair left, wait a few minutes and return to that area if necessar y.
6. Do not press down too hard with the device.
7. If you are treating facial hair, please see the Facial Tips section.
Important Note:
Do not be alarmed when the number of bars change on the Status Screen. When you first
start to glide, the Status Screen will automatically switch from the Treatment Level display (q) to the Thermicon™ Tip status display (w).
Check the icon to determine what information is being displayed.
q
w
17
Page 18
18
Rounded areas
To work on more difficult areas, go slowly and allow no!no! to follow the natural cur ve of the body. We recommend mastering the glide on arms and legs before moving on to the knees, elbows, face and bikini line.
NOTE: The bikini line may be extra-sensitive to temperature. If it becomes uncomfortably warm during treatment, lower the treatment level or work on a different area for a while. Do not go further than the bikini line.
Watch the Light
The signal light by the ThermiconTM Tip will guide you throughout your no!no! treatment. It lets you know when you are working at the right speed and warns you if the Thermicon™ Tip is torn, damaged or no longer working. The Signal Light is only visible while you are gliding the no!no!.
Page 19
When working at the right speed, the light will remain steady. If the light flickers, adjust your speed accordingly.
Meaning Blue Red
Correct gliding speed On and steady Off
No Thermicon™ Tip in socket Off On
Depleted Thermicon™ Tip Off On
Damaged Thermicon™ Tip Off On
Incorrect gliding technique Off On
Incorrect gliding speed Flickering Off
No movement Off Off
Charge no!no! Off Flickering
Table 2: Signal Light
19
Page 20
20
Master the Buffer
You’ve tried everything but your skin still doesn’t feel smooth? Did you remember to buff? Without buffing, crystallized hair remains in place, giving your skin a prickly feel. These treated hairs will eventually fall out – but why wait? Buffing exfoliates your skin, removes crystallized hair and leaves your skin feeling silky smooth.
To Buff:
1. Hold the Buffer by the flaps.
2. Firmly rub the buffer in either
a circular or back and forth motion over the treated area.
Page 21
Treatment Summary
1. Unplug no!no! from the power supply.
2. Remove the cover.
3. Insert the proper size Thermicon™ Tip for the area you are treating.
4. Push the On/Off button on the top of the unit.
5. Set the treatment level.
6. Glide no!no! over your skin at a 90º angle.
7. Buff after completing each section.
8. Apply a moisturizer.
21
Page 22
22
Thermicon™ Tips
1. To avoid possible malfunction
or harm, make sure to gently push the Thermicon™ Tip all the way into the socket.
2. WARNING! Always check the wire in the Thermicon™ Tip before use. Never use
a Thermicon™ Tip if the wire is bent
Bent thermodynamic wire Torn thermodynamic wire
,
torn or damaged in any way.
Page 23
Replace the Thermicon™ Tip:
The Thermicon™ Tip indicator appears as you no!no! and lets you know the present condition of your Thermicon™ Tip.
Replace the tip…
• When there are no bars on the
status screen.
• When the Thermicon™ Tip icon
flickers.
• If you notice that it is no longer
working efficiently.
• If the wire is damaged in any way.
• When the red Signal Light is on.
Thermicon™ Tip Status
New Slightly Used Used Depleted
Thermicon™
Tip ico n
23
Page 24
24
Treating Facial Hair
Your face is very sensitive. Take a few minutes and read these impor tant tips for the safest, most effective treatment. To view videos of facial hair treatments in action, go to
www.howtonono.com.
Always use the narrow tip and start with the lowest treatment level. And remember, if there is any discomfort, any where – STOP. Get comfortable - Practice using the no!no! on your arms or legs before moving to
your face.
TEST
Before you begin, use the instructions below and treat a small, discreet section of your face to see how your skin reacts to a no!no! facial hair treatment.
If there is any discomfort – STOP.
Page 25
Upper Lip and Mustache Area
When treating the mustache area – start under the nose and work your way outwards – be careful not to touch your lips or let your skin bunch up into the tip – hold the skin tight and/or purse your lips inward to create a straight, smooth surface.
DO NOT allow your lips to come in contact with the Thermicon wire. DO NOT go over one area excessively. If there is any discomfort – STOP.
Chin & Jaw Line
Starting from just below the jaw or chin line, glide your no!no! up and around the curve.
If you need to, pull skin straight and/or purse your lips inward to give your chin and jaw a straighter, smoother line.
If there is any discomfort – STOP.
25
Page 26
26
Sideburns
Start at the base of the chin and glide upwards following the curve of your face. If you need to, pull your skin tight and straight for a flat, smooth working surface.
If there is any discomfort – STOP.
IMPORTANTNOTE: The area just below the eye and around the eyelid is especially sensitive. DO NOT treat this area.
Page 27
Maintenance
Do not use any liquids of any kind to clean the Thermicon™ Tip or rollers.
Thermicon™ Tips
It is important to keep the Thermicon™ Tip free of hair debris. Allowing hair to build up may cause it to burn out prematurely or malfunction. Check and clean the tip periodically during each treatment session.
To clean the Thermicon™ Tip:
1. Turn off your no!no!
2. Remove the Thermicon™ Tip
3. Gently brush clean
27
Page 28
28
Rollers
Although not necessary to the performance of no!no!, keeping the rollers clean is all part of proper maintenance. Use the cleaning brush to remove excess hair and debris from the rollers.
Brush debris out and away from the socket in order to prevent any par ticles from falling into the socket.
If any hair or debris fall into the socket, this may cause no!no! to not function properly. Gently blow any particles out of the socket before beginning the next treatment.
Page 29
Troubleshooting
If no!no! does not start when you glide it on the skin:
• Press and hold the On/Off button down for a few seconds again until the Status
Screen appears.
• If it’s not turning on make sure the unit is charged.
• Check the Status Screen while gliding. If no bars appear, replace the Thermicon™
Tip.
• Make sure the Thermicon™ Tip is not bent or torn. Replace it if necessary.
If the device is not working properly, contact your point of purchase for examination or repair. The no!no! warranty is only valid if no!no! has been used according to the instructions in this guide. Retain all receipts and original packaging.
29
Page 30
30
Technical Information
Technical Specifications:
• Weight: 104gr
• Physical Dimensions: 120 X 40 X 25mm
(4.7 X 1.6 X 1.0 in)
• Mode of Operation: Continuous
Operating Conditions:
• Temperature: 5°C-30°C
• Humidity: 30%-80% RH
• Power Supply/Battery Charger Rating:
Input 100-240VAC/50-60Hz. 0.2A Output 8.4VDC 0.5A
Transport and Storage
• Temperature: -20°C to 80°C
• Humidity: 5-95% RH
• Atmospheric pressure: 0.1-1.5 atm.
Electrical Safety:
• Power Supply:
double insulation.
• This appliance is not suitable for use in
the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide.
• The Quality Management System of
Radiancy (Israel) Ltd. complies with the Quality Management Standard EN ISO 13485:2012.
• Design and technical specifications are
subject to change without notice.
• no!no! complies with the following
international standards and directives: General Requirements for Basic Safety and Essential Performance, 3rd Ed.: IEC60601-1:2005/EN60601-1:2006
Class II equipment –
Page 31
31
Electromagnetic Compatibility: IEC 60601-1-2:2007
• Electromagnetic Compatibility:
EN 60335-1, EN 60335-2-8 and EN 60335-2-23, EN 62233 and FCC Part 15 Subpart B and with Low Voltage Directive (Electric Safety) LVD: 2006/95/EC and the Electromagnetic Compatibility Directive 2004/108/EC.
• no!no! requires special precautions
regarding EMC and needs to be installed and put into ser vice according to the EMC information provided in this document.
• FCC, Class B This equipment has
been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause interference to radio communications. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Notice: The FCC regulations provide that changes or modifications not expressly approved by Radiancy Inc. could void your authority to operate this equipment.
Page 32
32
Symbols on Device
On/Off Switch
CE mark represents the compliance to the European Low Voltage Directive 2 006/95/EC and the Electromagnetic Compatibility Directive 2004/108/EC.
Protect the environment by not disposing of this product with household waste (2002/96/ EC). Check your local authorit y for recycling advice and facilities (Europe only).
Indicates the need to consult instructions for use.
Manufacturer:
Radiancy (Israel) Ltd. 5 Hanagar Street Hod Hasharon 4501307 Israel
EC Representative:
Photo Therapeutics Ltd 105-109 Sumatra Road London, NW6 1PL, U.K. Tel: +44 20 7319 9190 Fax: +44 20 7319 9191 Mail: info@phototherapeutics.com
Page 33
Manufacturer’s declaration for electromagnetic compatibility (EMC):
Table 1
Guidance and manufacturer's declaration – electromagnetic emissions – no!no!
The no!no! is intended for use in the electromagnetic env ironment specified below; The customer or the user of the no!no! should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment - guidance
RF emissions CI SPR 11
RF emissions CI SPR 11
Harmonic emissions IEC 61000-3-2
Voltage fluctuations/ flicker emissions IEC 61000-3-3
Group 1
Class B
Class A
Complies
The no!no! uses RF energy only for its inter nal function. Therefore, its RF emissions are ver y low and are not likely to cause any interference in nearby electronic equipment.
The no!no! is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
33
Page 34
34
Table 2
Guidance and manufacturer's declaration – electromagnetic emissions – no!no!
The no!no! is intended for use in the electromagnetic env ironment specified below; The customer or the user of the no!no! should assure that it is used in such an environment.
Immunity test
Electrostatic discharge (ESD) IEC 61000-4-2
IE6 0601-1-2 Test level
±6 kV contact ±8 kV air
Compliance level
±6 kV contact ±8 kV air
Electromagnetic environment ­guidance
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the rel ative humidity Should be at least 30%.
Electrical fast transient /burst IeC 61000-4-4 Surge IEC 61000-4-5
±2 kV for power supply lines ±1 kV for input/output lines Class A
±2 kV for power supply lines not Applicable
Mains power quality should be that of a typical public low­voltage power supply net work that supplies buildings used for domestic purposes, commercial or hospital environment.
Page 35
Table 2 Cont.
<5%UT (>95%dip in UT)
Voltage dips, short interruptions and voltage variations on power supply input lines
IEC 61000-4-11
Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 Surge IEC 61000-4-5
NOTE: UT is the a.c. mains voltage prior to application of the test level.
for 0,5 c ycle
40%UT (60%dip in UT) for 5 cycles <5%UT
70%UT (30%dip in UT) for 25 cycles <5%UT
<5%UT (>95%dip in UT) for 5s
3 A/m 3 A/m
<5%UT (>95%dip in UT) for 0,5 c ycle
40%UT (60%dip in UT) for 5 cycles <5%UT
70%UT (30%dip in UT) for 25 cycles <5%UT
<5%UT (>95%dip in UT) for 5s
35
Mains power quality should be that of a typical public low-voltage power supply network that supplies buildings used for domestic purposes, commercial or hospital environment.
Power frequency magnetic fields should be at levels characteristic of a typical public low-voltage power supply network that supplies buildings used for domestic purposes, commercial or hospital environment.
Page 36
36
Table 3
Guidance and manufacturer's declaration – electromagnetic emissions – no!no!
The no!no! is intended for use in the electromagnetic env ironment specified below; The customer or the user of the no!no! should assure that it is used in such an environment.
Immunity test
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
IE6 0601-1-2 Test level
3 Vrms
150 k Hz to 80 MHz
3 V/m
80 MHz to 2,5 GHz
Compliance level
3 Vrms
3 V/m
Electromagnetic environment - guidance
Portable and mobile RF communications equipment should be used no closer to any part of the no!no!, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance
d = 1.17P d = 1.17P 80 MHz to 800 MHz d = 2.34P 800 MHz to 2,5 GHz
where P is the maximum output power rating of the transmitter in watts (W) according to the transmit ter manufacturer and d is the recommended separation
Page 37
Table 3 Cont.
distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in
NOTE 1 At 80 MHz and 80 0 MHz, the higher frequenc y range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
a Field strengths from fixed RF transmitters, such as base stations for r adio (cellular/cordless) telephones and land mobile radios, amateur r adio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site sur vey should be considered. If the measured field strength in the location in which the no!no! is used exceeds the applicable RF compliance level above, the no!no! should be observed to verif y normal operation. If abnormal performance is obser ved, additional measures may be necessary, such as re-orienting or relocating the no!no!. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
each frequency range d.
Interference may occur in the vicinity of equipment marked with the following symbol:
37
Page 38
38
Table 4
Recommended separation distances between portable and mobile RF communications equipment and the no!no!
The no!no! is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the no!no! can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmit ters) and the no!no! as recommended below, according to the maximum out put power of the communications equipment.
Separation distance according to frequency of transmitter Meters [m]
Rated maximum output power of transmitter Watts [W]
0.01 0.12 0.12 0.24
0.1 0.37 0.37 0.74
150kHz to 80MHz d = 1.17P
80MHz to 800MHz d = 1.17P
800MHz to 2.5GHz d = 2.34P
Page 39
Table 4 Cont.
1 1.17 1.17 2.34
10 3.7 3.7 7.4
100 11.7 11.7 23.4
For transmitter s rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmit ter in watts ( W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 80 0 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflec tion from structures objects and people.
39
Page 40
Seeno!no!inaction!
Go to www.howtonono.com
for helpful hints, videos and more.