FEATURES
• Automatically comes on when motion is detected.
• Automatically turns light off.
• Photocell keeps the light off during daylight hours.
598-1286-01
UNPACKING
Be sure to remove all contents from packaging and verify
all items are present before assembling this light fixture.
is package includes the following items:
• Lantern (Includes: Top Cover, Glass Fixture, Fixture
Base)
• Universal mounting bracket (X-Bar)
• Mounting hardware
• Wire nuts
• Owner’s Manual
Before installation, record the model number listed
inside the xture. Attach receipt in case of possible
warranty issues.
Model Number:
REQUIREMENTS
• e Light Control requires 120 volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some electrical codes require installation by a qualified
electrician. Please check the codes in your area.
Carriage Light with
Motion-activated
Sensor
LANTERN ASSEMBLY
1. Place glass fixture onto base assembly.
2. Line up the arrow on the bottom of glass fixture
with the arrow on the fixture base (see illustration
below).
Glass Fixture
Arrows
Fixture Base
Glass Fixture
Fixture Base
3. Gently push the two pieces together and rotate the
glass fixture 90° as shown below.
Models 52-4473-6
52-4474-4
Installation and Operating
Instructions

2
598-1286-01
WIRINGINSTALLATION
For best performance, mount the fixture about 6 feet (1.8
m) above the ground.
1. Remove two decorative nuts.
2. Remove X-Bar.
3. Tighten mounting screws on X-Bar finger tight.
4. Attach X-Bar to junction box.
Junction Box
X-Bar
Decorative Nut
Lantern
Lantern Mounting
Screw
X-Bar
One Motion Light
Two Motion Lights
CAUTION: DO NOT connect the RED wire unless
you want to control other lights from the motion
sensor (see Optional Wiring).
Note: All wiring must be run in accordance with the
Canadian Electrical Code through conduit or another
acceptable means. Contact a qualified electrician if there
is any question as to the suitability of the system.
WARNING: Turn power o at circuit breaker
or fuse.
Bracket Mounting
Screw
Connect the fixture wires to the wires in the junction
box. Twist the wires together and secure with wire connectors.
Note: We recommend having an assistant help hold the
lantern assembly during the wiring process.
Black
White
Green or
Bare
Black
White
Green or
Bare

3
598-1286-01
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and twist
one end together with the bare fixture wire and the
box ground wire. Secure with a wire connector. Secure
the other end of the “pigtail” with the GND screw on
the X-bar.
Black to black
White to white
If you have metal junction box, you may not need the green
“pigtail”. If you are unsure about the grounding method,
consult your local building code.

4
598-1286-01
Wiring Diagram 1
(Standard)
Wiring Diagram 2
OPTIONAL WIRING
is fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of additional
lighting may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the
marking which specifies the maximum lamp wattage for which the fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up.
For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325
Watts.
Wiring Diagram 1 – When wiring to control a standard light xture: Strip the motion sensor’s red wire and con-
nect to the standard light’s black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts
(3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light xture (Master / Slave): Strip the
red wire in both light fixtures. Connect the red wire of the controlling (master) fixture to the red and black wires of the
controlled (slave) fixture. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 3 – When wiring so either motion light turns on the both motion lights (Master / Master):
Strip the red wire in both light fixtures. Connect the red wire of one fixture to the red wire of the second fixture. Note:
In most installations, an additional wire (same gage as existing house wire) will have to be installed in the house to
connect the two fixtures as master / master. Connect all white wires together and all black wires together. Total fixture
ratings must not exceed 360 Watts (3.0 A).
Master
Wiring Diagram 3
Black
White
Red
Green or
Bare
Slave
Black
White
Red
Green or
Bare
Master
Black
White
Red
Green or
Bare
Master

5
598-1286-01
TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light switch.
Note: Sensor has a 1 1/2 minute warm up period before
it will detect motion. When first turned on wait 1 1/2
minutes.
2. Set:
ON-TIME switch to TEST
SENSITIVITY dial to Midway
3.
Walk through the coverage area noting where you are
when the lights turn on. In TEST mode, light will stay
on for 5 seconds after sensing motion and then turn
off.
4. Adjust the SENSITIVITY to increase or decrease
the range as needed. Too much sensitivity may cause
false triggering due to heat sources in the coverage
area (see
Adjustment of Coverage Area or Troubleshooting
section).
5. Set the amount of ON-TIME you want the light to stay
on after motion is detected (1, 5, or 10 minutes).
Maximum Range Maximum
Coverage Angle*
(Top View)
FINAL ASSEMBLY
1. Push the wires into the junction box. Make sure none
of the wires get pinched.
2.
Slide the fixture assembly onto the mounting screws.
Tighten decorative nuts removed in step 1 of Installation
section securely against fixture base.
Junction Box
Mounting Screw
Decorative Nut
3. Install one medium base light bulb (100 Watt maximum).
4. Place top cover onto fixture and attach using the two
decorative nuts (included). Hand tighten only.
5. After completing the tests on page 5, caulk around
fixture base with silicone weather sealant.
Top Cover
Decorative Nut
Light Bulb (100
Watt Maximum)
Fixture Assembly
Caulk Around
Fixture Base
TEST 1 5 10
MINUTE
– +
SEN
30 ft.
(9.1 m)
6 ft.
(1.8 m)
180°