Page 1
R20 1X UBS Macro B T S Hardw are Installation Site v erication
Site verication
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Site installation checks
V erify that the site is ready for BTS installation before performing the physical installation.
A detailed layout of the site is provided with the site -specific documentation. Before installing
the hardware, compare the information presented here to the site -specific documentation layout
and verify with the Site Manager for the following:
• All cable trays are installed.
• All external signal cables are connected.
• Site is clean.
■
■
• Site specific documentation covering all site dependent installation information is available.
• The installation area has restricted access. Equipment is meant to be installed and
operated in a restricted access location. In order to maintain UL listing, equipment must
be installed in a restricted access area.
• The site can maintain the required temperature range.
• The layout meets the minimum clearance requirements for the equipment as listed in
T able 2 -5 , T able 2 -6 and T able 2 -7 .
• All building DC power cables are connected.
• The building meets the voltage and power requirements shown in
built)
documents.
Site description (as
• P ower cables are present that meet the requirements shown in T able 2 -8 .
• The procedure, tools, and equipment required to mount the rack to the floor are specified
by a Structural Engineer .
• The site can meet the footprint dimensions (as shown in Figure 2 -5 ) and not violate any of
the required clearances.
• Site grounding is according to Grounding Guidelines for Cellular R adio Installations
(Motorola part number 68P81150E62).
• The screen (outer shield) of the RF antenna coaxial cable must be connected to earth
(grounded) at the entrance to the building. This should be done in accordance with
applicable national electrical installation codes (Section 820.93 of the National Electrical
Code, ANSI/NFP A 70.
• V erify that the Master Ground Bar is connected to a solid earth ground. This is required
to ensure protection from hazardous voltages by providing a high integrity protective
earthing circuit when the frame is later grounded to the Master Ground Bar .
68P09283A62 -2 2 -15
PRELIMINARY A UG 2007
Page 2
Site v erication Chapter 2: UBS Macro B T S Installation Procedure
• The frames can be mounted as specified in the site -specific documentation.
• Each frame has its own main power cut off .
Motorola recommends a separate main power cut off for each frame of the
system.
Temperature range
The site building must be able to maintain a temperature between 0° C and 50° C . The life span
of electronic equipment is shortened by environmental variations, even though it is designed to
operate at extreme temperatures.
Frame physical dimensions
Frame clearances
The following table gives the frame dimensions.
Table 2 -4 Fr ame dimensions
Height W idth Depth
1800 mm
(70.86 inches)
The following tables give the frame clearances for various configurations.
575 mm
(22.63 inches)
(27.55 inches)
700 mm
Maximum
W eight
312 kg
(688 lbs)
Table 2 -5 Minimum fr ame clear ances for airow
Front Rear T op
150 mm
(5.9 inches)
150 mm
(5.9 inches)
Left side
300 mm
(11.8 inches)
0 mm
(0 inches)
Right side Bottom
0 mm
(0 inches)
Table 2 -6 Minimum fr ame clear ances for maintenance - front access only
0 mm
(0 inches)
Front Rear T op
700 mm
(27.55 inches)
2 -16 68P09283A62 -2
150 mm
(5.9 inches)
300 mm
(11.8 inches)
Left side
75 mm
(2.95
inches)
Right side Bottom
75 mm
(2.95 inches)
0 mm
(0 inches)
PRELIMINARY A UG 2007
Page 3
R20 1X UBS Macro B T S Hardw are Installation Site v erication
Table 2 -7 Minimum fr ame clear ances for maintenance - front and rear access
Front Rear T op
700 mm
(27.55 inches)
150 mm
(5.9 inches)
300 mm
(11.8 inches)
Frame DC input power and power cabling information
T able 2 -8 gives DC input power cabling and circuit breaker information.
F or frame maximum and typical power consumption, refer to the
Specification (B1)
whichever is applicable.
Table 2 -8 +27 V DC and –48 V DC Fr ame P ower Cabling and P ower Supply Break er
Information
Qty of XMIs
1 661.11 cm
1 833.63 cm
1 1051.25 cm
2 661.11 cm
2 833.63 cm
2 1051.25 cm
3 661.11 cm
3 833.63 cm
3 1051.25 cm
Maximum
cable length
(21.69 ft)
(27.35 ft)
(34.499 ft)
(21.69 ft)
(27.35 ft)
(34.499 ft)
(21.69 ft)
(27.35 ft)
(34.499 ft)
document or
Cable
size
(A WG)
2/0 200 1 250
3/0 150 1 250
4/0 150 1 250
2/0 200 1 250
3/0 150 1 250
4/0 150 1 250
2/0 200 2 250
3/0 150 2 250
4/0 150 2 250
Left side
0 mm
(0 inches)
UBS (1.9 GHz) BTS Specification (B1)
Cable insulation
temperature rating
(° C)
Qty of power
feeds (+ and
- pairs)
Right side Bottom
0 mm
(0 inches)
0 mm
(0 inches)
UBS (800 MHz) BTS
document
Breaker size per
feed (Amps DC)
Continued
68P09283A62 -2 2 -17
PRELIMINARY A UG 2007
Page 4
Site v erication Chapter 2: UBS Macro B T S Installation Procedure
Table 2 -8 +27 V DC and –48 V DC Fr ame P ower Cabling and P ower Supply Break er
Information (Continued)
Qty of XMIs
4 661.11 cm
4 833.63 cm
4 1051.25 cm
Frame positioning
Typically , equipment frames are positioned side -by -side, with the frame fronts facing the same
direction.
Rack base description and dimensions
The base of the rack consists of the following:
• Isolation pads attached to the base to isolate the rack from the floor . The isolation pads are
positioned between the floor and the base.
Maximum
cable length
(21.69 ft)
(27.35 ft)
(34.499 ft)
Cable
size
(A WG)
2/0 200 2 250
3/0 150 2 250
4/0 150 2 250
Cable insulation
temperature rating
Qty of power
feeds (+ and
(° C)
- pairs)
Breaker size per
feed (Amps DC)
• Six 22 mm (0.87 inches) M12 mounting holes.
• Plastic shoulder washer in each hole to isolate the frame from the floor . Figure 2 -5 shows
the footprint of the rack.
2 -18 68P09283A62 -2
PRELIMINARY A UG 2007
Page 5
R20 1X UBS Macro B T S Hardw are Installation Site v erication
ti-cdma-05689.eps
(264.50)
2X 75.00
(Clearance)
6X M12 Fasteners
(429.80)
(284.20)
(700.00)
700.00
(Clearance)
(529.00)
(447.00)
(223.50)
(101.60)
2X 209.55 +/- 0.40
226.60 +/- 0.40
2X 277.40 +/- 0.40
2X 50.80 +/- 0.40
150.00
(Clearance)
2X 209.55 +/- 0.40
FRONT
Measu rements are in mm.
C
L
Figure 2 -5 R ack footprint
68P09283A62 -2 2 -19
PRELIMINARY A UG 2007
Page 6
T ask 1: Installing RGPS Head Chapter 2: UBS Macro B T S Installation Procedure
Task 1: Installing RGPS Head
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this procedure is to install the optional Remote GPS (RGPS) head and cables
(NN and AA). The site configuration/characteristics determines whether an RGPS head and
cables are to be installed.
Any of the following RGPS heads may be used:
• STLN6594 (Motorola part number)
• 0186012H04 (Motorola part number)
■
■
RGPS head installation
Required items
Cable NN works with any of the above listed RGPS heads.
The following tools are required:
• Adjustable torque ratchet with metric socket set
• Flat head screwdriver
• Lightning Arrestor (Motorola part number CGDSO971017AA1 or equivalent)
T able 2 -9 gives a list of the cables.
Table 2 -9 List of required cables for RGPS head installation
Cable Quantity
AA
NN
1 SGKN4430
Part Number Description
15 pin D -connector on one end and loose
(3086433H14)
3086039H10
3086039H11
3086039H12
wires on the other end. Cable is Motorola P/N
3086433H12.
RGPS cable, 15 m (50 ft); part of Option T472AG
RGPS cable, 38 m (125 ft); part of Option T472AH
RGPS cable, 76 m (250 ft); part of Option T472AJ
1
2 -20 68P09283A62 -2
PRELIMINARY A UG 2007
Page 7
R20 1X UBS Macro B T S Hardw are Installation T ask 1: Installing RGPS Head
ti-cdma-05700.eps
NN
AA
Remote GPS
Head
Lightning Arrestor
BTS
SSI
Table 2 -9 List of required cables for RGPS head installation (Continued)
Cable Quantity
Part Number Description
3086039H13
RGPS cable, 152 m (500 ft); part of Option T472AK
Cabling diagrams
The following figures show the cabling for an RGPS head.
Figure 2 -6 RGPS cabling diagr am
3086039H14
RGPS cable, 304 m (1000 ft); part of Option
T472AL
68P09283A62 -2 2 -21
When wiring the Motorola P/N STLN6594 RGPS Head at a new B T S site, the Y ellow
and Y ellow/Black wires on both sides of the lightning arrestor must be disconnected
(see Figure 2 -7 and Figure 2 -8 ). Otherwise, the STLN6594 RGPS Head will be
permanently damaged.
If a Motorola P/N 0186012H04 or 0186012H03 RGPS Head at an existing B T S site
is being replaced with the Motorola P/N STLN6594 RGPS Head, the Y ellow and
Y ellow/Black wires on both sides of the lightning arrestor must be disconnected (see
Figure 2 -7 and Figure 2 -8 ). Otherwise, the STLN6594 RGPS Head will be permanently
damaged.
PRELIMINARY A UG 2007
Page 8
T ask 1: Installing RGPS Head Chapter 2: UBS Macro B T S Installation Procedure
Bl ue/Bl a ck
Bl ue
Y e l l o w / Bl ack
Y e l l o w
Green /Blac k
Green
Whi te/Bla ck
Whi te
Brow n/ Bl ack
Brow n
1
2
3
4
5
6
7
8
9
1
0
1 1 1 2
Earth Groun d
RGPS C A BL E CO NNECT OR
(V IEWE D F ROM CABL E PE R S P E CTIV E )
NN AA
CA B L E D RA I N
L I G H TNING ARR E S T O R
(W N P C GDSO971017AA 1
OR E QUI V ALENT)
D - C O N N E C T O R
TO B T S
1
1 4
1 0
2
4
1 2
7
8
1 5
9
ALT ERN A T E R G PS HEAD (M OTOR OLA
P/N 0186012H04)
CEL L SITE
GRO U ND =
R e d
R e d /Bl ack
3
11
Yello w
Yellow/Black
Yello w
Yellow/Black
No Connection
No Connection
t i - c d m a - 0 5 7 0 1 . e p s
RGPS H E AD ( M O T ORO L A
P/N STLN6594)
- OR -
The Motorola P/N 0186012H04 RGPS Head will work with the Y ellow and Y ellow/black
wires disconnected or connected on both sides of the lightning arrestor .
Figure 2 -7 RGPS wiring
2 -22 68P09283A62 -2
PRELIMINARY A UG 2007
Page 9
R20 1X UBS Macro B T S Hardw are Installation T ask 1: Installing RGPS Head
Blue/Blac k
Blue
Green/Blac k
Green
White/ Blac k
White
Red /Bl ac k
Yellow
/Black
Yellow
Red
Brown/Blac k
Brown
Cab le Dr ain
B l u e/B l ac k
B l u e
Green/B l ac k
Green
W h i te/ B l a c k
W h i t e
R e d /B l ac k
R e d
B r o w n / B l a ck
B r o w n
C a b l e D r a i n
+ 4 0 V
D C
L i n e s + 1 7 V
D
C
L i
n
e s + 1
7
V
D C
L i n e s
+ 1 7 V
D
C
E q u i p m e n t + 1 7 V
D
C
E q u i
p
m e n t + 4 0 V
D C
E q u i p m e n
t
N O T E
N N ( R G PS )
TO R G P S
AN TEN N A
EA RT H GROUN D
MOU NT IN G PL A TE
B l u e/B l ac k
B l u e
Y e l l o w /B l ac k
Y e l l o w
Green/B l ac k
Green
W h i t e/B l ac k
W h i t e
R e d /B l ac k
R e d
B r o w n / B l a ck
B r o w n
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
No Connection No Connec ti on
W h e n t h e l i g h t n i n g a r r e s t o r i s
p r o p e r l y w i r e d , t h e c o l o r o f t h e w i r e
a t t a c h e d t o e a c h " E q u i p m e n t " s c r e w
t e r m i n a l s h o u l d m a t c h t h e c o l o r o f
t h e w i r e a t t a c h e d t o t h e c o r r e s p o n d -
i n g " L i n e s " s c r e w t e r m i n a l .
AA (R GP S)
TO BTS
C A U T I O N !
A l l l i g h t n i n g a r r e s t o r w i r e c o n n e c t i o n s
s h o u l d b e t h o r o u g h l y i n s p e c t e d f o r i n t e g r i t y
a n d a c c u r a c y . V e r i f y t h a t t h e c o n n e c t i o n s
a r e e x a c t l y a s s h o w n i n t h i s d i a g r a m .
P r o b l e m s d u e t o w i r i n g e r r o r s c a n r a n g e
f r o m i m p r o p e r B T S o p e r a t i o n t o p e r m a n e n t
d a m a g e t o t h e R G P S h e a d . T h e o p e r a t i o n a l
p r o b l e m s m a y n o t b e e a s i l y d e t e c t a b l e .
Yellow/Black
Yellow
Figure 2 -8 RGPS lightning arrestor wiring
Mounting diagrams
Figure 2 -9 and Figure 2 -10 show the mounting details for the RGPS heads.
68P09283A62 -2 2 -23
PRELIMINARY A UG 2007
Page 10
T ask 1: Installing RGPS Head Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05702.eps
THREADED MOUNT
ADAPTER
THREADED MOUNT
ADAPTER
12-PIN DEUTSCH
TYPE MMP
CONNECTOR
12-PIN DEUTSCH
TYPE MMP
CONNECTOR
ALT ERN A T E R G PS HEAD
(MOTO ROL A
P/N 0186012H04)
RGPS HEAD
(MOTO ROL A
P/N STLN6594)
Figure 2 -9 RGPS heads
2 -24 68P09283A62 -2
PRELIMINARY A UG 2007
Page 11
R20 1X UBS Macro B T S Hardw are Installation T ask 1: Installing RGPS Head
ti-cdma-05740.eps
WALL MOUNTING
BRACKETS (2)
CLAMP BRACKETS (2)
U-BOLTS
CABLE TO LIGHTNING
ARRESTOR (CABLE NN)
RGPS HEAD WITH
12 PIN MALE
CONNECTOR
MATING
CONNECTORS
RGPS INTERFACE
CABLE WITH 12 PIN
FEMALE CONNECTOR
ON ONE END AND
UNTERMINATED WIRE
ON OTHER END
CABLE TO LIGHTNING
ARRESTOR (CABLE NN)
ALT ERN A T E R G PS HEAD (M OTOR OLA
P/ N 0 1 8 6 0 1 2 H 0 4 )
RGPS H E AD ( M O T ORO L A
P/ N STL N6 5 9 4 )
Figure 2 -10 Installing the RGPS head
Cable pinout
Figure 2 -11 shows the connector pins on cables AA and NN . T able 2 -10 gives the pinout for
cable AA and NN and signal names.
68P09283A62 -2 2 -25
PRELIMINARY A UG 2007
Page 12
T ask 1: Installing RGPS Head Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-00047.eps
1
2
3
4
5
6
7
8
9
10
11 12
CONNECTOR FOR
CABLE NN
PIN 1
CONNECTOR FOR
CABLE AA
PIN 9
Figure 2 -11 Connector pin numbering for cables NN and AA
Table 2 -10 Pinout for cables NN and AA
Cable NN (12-cond) Cable AA (12-cond)
Pin
(12-pins)
9
1 P ower 1
8
10
4
5
Transmit P ort (-) Green-Black
Transmit P ort (+)
Signal W ire Color
DC Ground 1 Blue-Black
Blue
Not Used Y ellow-Black
Not Used Y ellow
Green 1
Pin
(15-pins)
15 RGPS Return
8
14
7
9
Signal
RGPS +27 V Supply
Not Used
Not Used
DA T A (-) From Head
DA T A (+) From
Head
2
3
7
6
12
11
Receive P ort (-) White-Black
Receive P ort (+) White
Not Connected Red-Black
Not Connected Red
PPS Timing (-) Brown-Black
PPS Timing (+)
Brown
12
4
11
3
10
2
DA T A (-) T o Head
DA T A (+) T o Head
TDR Ground
TDR (+)
SYNC (-) From Head
SYNC (+) From
Head
Cable Drain
13
Ground
(Shield)
5, 6
W ire colors are the same for both cables.
Not Connected
2 -26 68P09283A62 -2
PRELIMINARY A UG 2007
Page 13
R20 1X UBS Macro B T S Hardw are Installation T ask 1: Installing RGPS Head
Procedure
The procedure to install the RGPS antenna is as follows:
Procedure 2 -1 Procedure to install an RGPS head
1
2
3
4
5
6
7
8
Determine the mounting location for the RGPS head.
The structure of the w all should be v eried b y a qualied structur al
engineer . Mounting the RGPS head and hardw are to an inadequate
w all structure and/or using inadequate installation methods can
result in serious personal injury .
Use the appropriate mounting bolts for the mounting surface and install the
two wall mounting brackets. Refer to Figure 2-10 .
Route the 12-pin Deutsch (that is, circular) connector end of the RGPS cable
(cable NN) to the RGPS head.
Connect the RGPS cable (cable NN) connector to the RGPS head 12-pin
circular connector as shown in Figure 2-7 and Figure 2-10 . Tighten the
spinning flange on the connector a quarter turn, to secure the connection.
Insert the RGPS mounting pipe into the threaded mount of the RGPS head
and carefully tighten it manually .
Install the RGPS mounting pipe into the mounting brackets as shown in
Figure 2-10 . Tighten the U -bolt clamps to secure the assembly . F or the
STLN6594 RGPS Head, tape or tie-wrap the cable to the mounting pipe.
Route the free end of the BTS RGPS cable (cable NN) to the RGPS
cable lightning arrester . Remove any excess cable length and strip off
approximately 15 cm of the cable outer insulation.
Connect the twelve (12) wires and cable drain of the cable end to the
lightning arrester as shown in Figure 2-8 . Double check the lightning
arrester connections for compliance as displayed in Figure 2-8 .
RGPS cable AA gets connected to the UBS Macro BTS and then
routed to the RGPS cable lightning arrester during T ask 8.
68P09283A62 -2 2 -27
PRELIMINARY A UG 2007
Page 14
T asks 2 -3: Installing R ack & Ground Cable Chapter 2: UBS Macro B T S Installation Procedure
Tasks 2 -3: Installing Rack & Ground Cable
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objectives of this procedure are as follows:
• Mount the rack to the floor .
• Install the ground cable (DD).
Rack requirements
The UBS Macro BTS equipment is designed to be mounted in an open standard 19–inch rack.
■
■
Structural engineer prerequisite
T o ensure proper equipment support, grounding, and easy installation, Motorola recommends
that the UBS Macro BTS equipment be mounted in one of the following applicable Motorola
racks:
• STHN4120 19–inch (1800 mm)
• STHN4121 19–inch (1400 mm)
• STHN4122 19–inch (1000 mm)
Ensure that the procedure, tools, and equipment required to mount the rack to the floor are
specified by a Structural Engineer .
2 -28 68P09283A62 -2
PRELIMINARY A UG 2007
Page 15
R20 1X UBS Macro B T S Hardw are Installation T asks 2 -3: Installing R ack & Ground Cable
Required items
The following items are required:
• R ack
• 10 mm socket
• T orque driver
• Flat blade screwdriver
• 6 carbon steel grade 8.8 bolts M12 - customer supplied
• Other items, specified by the Structural Engineer , that are required to install the rack
• Cable DD - customer supplied ground cable, 4 A WG or larger diameter
• T wo -hole ground lug and mounting nuts - part of rack hardware kit (CGDSTB54205)
68P09283A62 -2 2 -29
PRELIMINARY A UG 2007
Page 16
T asks 2 -3: Installing R ack & Ground Cable Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05691.eps
Earth Ground
Terminal Studs
Ground Cable With
2-hole Lug Fastened
To Ground Terminals
Rack
(top/rear view, shown
partially cut away)
Location of rack earth ground terminals
Figure 2 -12 shows the location of the ground terminals on the rack.
Figure 2 -12 Location of ground terminals on a Motorola r ack
Procedure
2 -30 68P09283A62 -2
Procedure 2 -2 gives the procedure for performing T asks 2 -3.
Procedure 2 -2 P erforming T asks 2 -3
1
Mount the rack to the floor using the hardware, tools and procedures
defined by the Structural Engineer .
Motorola recommends using carbon steel grade 8.8 M12 bolts.
PRELIMINARY A UG 2007
Continued
Page 17
R20 1X UBS Macro B T S Hardw are Installation T asks 2 -3: Installing R ack & Ground Cable
Procedure 2 -2 P erforming T asks 2 -3 (Continued)
2
3
4
5
6
7
Route the ground cable (cable DD) between the Master Ground Bar (MGB)
and the rack.
Ground cables must not have sharp bends.
Strip insulation from the frame end of cable DD .
A ttach the 2-hole lug to the rack -end of the cable DD .
A ttach the end of cable DD with the 2-hole lug to the 2 terminal studs at the
top of the rack. Using 2 nuts, 10 mm socket and ratchet, tighten the nuts to
5.65 N-m (50 inch-lb). Refer to Figure 2-12 for location of ground terminal
studs on the rack.
Cut cable DD to length and connect it to the Master Ground Bar .
V erify that the Master Ground Bar is connected to a solid earth ground.
68P09283A62 -2 2 -31
PRELIMINARY A UG 2007
Page 18
T ask 4: R ack Mounting the Optional PSM Shelf Chapter 2: UBS Macro B T S Installation Procedure
Task 4: Rack Mounting the Optional PSM Shelf
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this procedure is to perform task 4:
• F or -48 V DC or 220 V AC UBS only .
Install the PSM shelf to the bottom of the rack. The site configuration/characteristics will
determine if a PSM shelf is to be installed.
• Install the appropriate, -48 V DC or 220 V AC , PSMs into PSM shelf slots 1 and 2. Either up
to two -48 V DC or up to two 220 V AC PSMs can be installed in the shelf . One PSM is
required for the low capacity configuration and the second PSM is for redundancy .
■
■
Required items
Procedure
The following items are required:
• Either a -48 V DC or 220 V AC PSM shelf (whichever is applicable)
• Either up two -48 V DC or 220 V AC PSMs (whichever is applicable)
• Eight (8) M5 x 12 mm screws for mounting the PSM shelf - these screws are included in
the STGN4034 Installation Kit that is packaged with the UBS Macro carrier strip assembly
• T ape measure with millimeter scale, capable measuring up to 1200 mm or with inch scale,
capable measuring up to 48 inches; for measuring screw location heights on rack
• TORX T25 bit and driver
• T orque driver
Procedure 2 -3 gives the procedure for performing T ask 4.
Procedure 2 -3 Procedure for T ask 4
1
2
2 -32 68P09283A62 -2
Locate the bottom RU that is to be used for the installation of the PSM shelf .
Using a tape measure, measure mounting screw location heights on each
side of the rack. Measure from the bottom of the RU determined in step 1
(Refer to Figure 2-13 ). Mark the following screw locations:
Continued
PRELIMINARY A UG 2007
Page 19
R20 1X UBS Macro B T S Hardw are Installation T ask 4: R ack Mounting the Optional PSM Shelf
Procedure 2 -3 Procedure for T ask 4 (Continued)
• 136 mm (5.35 inches) for PSM shelf
3
4
5
6
7
P artially insert an M5 x 12 mm screw into each location marked on the rack.
Leave the screw heads extending 7 mm out from the rack surface.
Remove the PSM shelf from its packaging.
Align the keyhole slots in the PSM shelf with the bottom screws, installed in
step 3 above (Refer to Figure 2-14 ).
Insert screws in the 6 open slots of the PSM shelf and tighten all 8 PSM
shelf screws to 4.77 N-m (42 in-lb).
PSM weighs appro ximately 5 kg. Be careful when handling the
PSM to prev ent damage to the equipment and personal injury .
Install the appropriate PSMs into PSM shelf slots 1 and 2 as follows:
1. Grasp the handle on the front panel of the PSM with one hand while
carefully supporting the bottom of the module with the other hand.
2. Properly orient the PSM and insert it into the slot.
3. Slowly slide the module into the shelf until the rear connectors are
fully seated. Make sure that the PSM is fully engaged with the shelf
backplane slot connectors.
8
Using a T25 TORX bit and torque driver , tighten the PSM captive retaining
thumbscrew to 2.37 N-m (21 in-lb).
68P09283A62 -2 2 -33
PRELIMINARY A UG 2007
Page 20
T ask 4: R ack Mounting the Optional PSM Shelf Chapter 2: UBS Macro B T S Installation Procedure
136
Hanger Screw Layout for optional PSM Shelf
Hanger Screw
(Detail A)
NOTE
1. All dimensions are in millimeters
2. 1800 mm high rack shown. Dimension and hanger screw locations
are also applicable for the 1400 mm rack.
ti-cdma-06011.eps
Detail A
Hanger Screw Extension
7
Procedural reference diagrams
The following diagrams help clarify certain steps in Procedure 2 -3 .
Figure 2 -13 Hanger screw la y out for the optional PSM shelf
2 -34 68P09283A62 -2
PRELIMINARY A UG 2007
Page 21
R20 1X UBS Macro B T S Hardw are Installation T ask 4: R ack Mounting the Optional PSM Shelf
ti-cdma-05869.eps
PSM shelf keyhole
located on hanger screw
NOTE
1. A keyhole/hanger screw is located on both the right and left sides.
Both keyholes/hanger screws should be engaged at the same time.
Figure 2 -14 Hanging the PSM shelf
68P09283A62 -2 2 -35
PRELIMINARY A UG 2007
Page 22
T ask 5: R ack Mounting for Low -Capacit y Fr ame Chapter 2: UBS Macro B T S Installation Procedure
Task 5: Rack Mounting for Low -Capacity Frame
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of T ask 5 is to install the UBS Macro carrier strip assembly into an EIA 19 -inch
rack.
The UBS Macro carrier strip assembly contains all of the equipment required for configuring a
low -capacity , +27 V DC starter frame. The layout of the equipment on the carrier strips allows
capacity expansion of the frame.
The most common and preferred method is to install the UBS Macro carrier strip assembly into
an 1800 mm or 1400 mm high rack. This method requires that there be 600 mm of clearance on
the left and right sides of the rack.
■
■
Required items
The UBS Macro carrier strip assembly requires a minimum of 27 R ack Units (RUs) of
continuous space.
The following items are required:
• UBS Macro carrier strip assembly
• T ape measure with millimeter scale, capable measuring up to 1200 mm or with inch scale,
capable measuring up to 48 inches; for measuring screw location heights on rack
• T wenty -six (26) M5 x 12 mm screws for mounting the UBS carrier strip assembly - these
screws are included in the STGN4034 Installation Kit that is packaged with the UBS Macro
carrier strip assembly
• TORX T25 bit and driver
• T orque driver
• 10 mm socket and ratchet
2 -36 68P09283A62 -2
PRELIMINARY A UG 2007
Page 23
R20 1X UBS Macro B T S Hardw are Installation T ask 5: R ack Mounting for Low -Capacit y Fr ame
Procedure
Procedure 2 -4 gives the procedure for performing T ask 5.
Procedure 2 -4 R ack Mounting the Low -Capacit y , +27 V DC UBS Macro B T S Assembly
1
2
3
4
Using a tape measure, measure mounting hanger screw location heights on
each side of the rack (see Figure 2-15 Hanger screw layout for UBS Macro
carrier strip assembly on page 2- 40 ). Measure down from the very top of the
rack. Mark the following screw locations:
• 95.25 mm (3.75 inches) for the top of the UBS Macro carrier strip
assembly
P artially insert an M5 x 12 mm screw into each location marked on the rack.
Leave the screw heads extending 7 mm out from the rack surface.
Move the pallet with the unpacked UBS Macro carrier strip assembly and
support near the rack so as to allow movement on both sides of the support
and in front of the rack. Leave the carrier strip assembly on the support.
step 5 through step 7 are for the optional removal of the XMI from the UBS
Macro carrier strip assembly . XMI removal should only be performed if the
UBS Macro carrier strip assembly is too heavy for two people to lift.
The preferred method is to skip the XMI removal steps and use a
suitable device or 4 people to lift the assembly/carrier strips.
The UBS Macro carrier strip assembly with the XMI installed
weighs approximately 60 kg (132.3 lb) and the XMI weighs 23-28
kg (50.7-61.7 lb) depending on the RF band.
If you are skipping the XMI removal steps, go to step 8 . Otherwise, go to
step 5 .
5
6
68P09283A62 -2 2 -37
Remove the XMI from the UBS Macro carrier strip assembly . Refer to the
photographs in Figure 2-16 Removing the XMI from the carrier strip assembly
on page 2- 41 . Disconnect all cables from the front of the XMI (see photographs
A and B). Dress these disconnected cables away from the front of the XMI.
Using a T25 TORX driver , remove the four XMI mounting screws; two screws
at each of the top and bottom mounting tabs on the front of the module.
Continued
PRELIMINARY A UG 2007
Page 24
T ask 5: R ack Mounting for Low -Capacit y Fr ame Chapter 2: UBS Macro B T S Installation Procedure
Procedure 2 -4 R ack Mounting the Low -Capacit y , +27 V DC UBS Macro B T S Assembly
(Continued)
7
8
Using two hands, grasp the XMI by its handle and lift it straight up and out
of the UBS Macro carrier strip assembly (see photographs C and D). Set
the XMI aside for later reinstallation.
An XMI module that is not in a shelf should alw a ys be set on its
side and nev er on its edge. This will prev ent the XMI module from
tipping o v er and causing damage or injury .
The carrier strips allow up to four people to carefully lift the UBS
Macro carrier strip assembly off the support and onto the rack. The
assembly can also be lifted via some mechanical aid (hoist, etc.)
attached to the lifting loops on the ends of the carrier strips.
F our people, two on each side, are needed to lift the carrier strip
assembly with the XMI installed.
T wo people, one on each side, are needed to lift the carrier strip
assembly without the XMI installed.
Lift the UBS Macro carrier strip assembly up and off of the support and onto
the rack (see Figure 2-17 Lifting and hanging the carrier strip assembly on
the rack (XMI shown removed) on page 2- 42 ).
9
10
1 1
12
13
Using the carrier strip hanger screws previously installed in the rack, align
the top carrier strip keyhole slots with the two hanger screws. Hang the
carrier strip assembly on these two screws.
Insert a screw in the two bottom carrier strip keyhole slots (see Figure 2-18
Carrier strip assembly keyhole screw locations on page 2- 43 ). Do not tighten
the screws in carrier strip keyhole slots.
Insert screws in the 22 open slots of the various shelves of the carrier strip
assembly . Using a T25 TORX driver , tighten these 24 screws to 4.77 N-m
(42 in-lb).
Using a T25 TORX driver , tighten the four screws in carrier strip keyhole
slots to 4.77 N-m (42 in-lb).
If the XMI was removed, go to step 14 .
Continued
2 -38 68P09283A62 -2
PRELIMINARY A UG 2007
Page 25
R20 1X UBS Macro B T S Hardw are Installation T ask 5: R ack Mounting for Low -Capacit y Fr ame
Procedure 2 -4 R ack Mounting the Low -Capacit y , +27 V DC UBS Macro B T S Assembly
(Continued)
14
15
16
17
Grasp the XMI by its handle with one hand and the XMI bottom edge with the
other hand. Lift the XMI and fully insert it into slot 1 (left most slot) of the XMI
shelf . See photograph A of Figure 2-19 Reinstalling the XMI on page 2- 44 .
Insert the four XMI mounting screws; two screws at each of the top and
bottom mounting tabs on the front of the module. Using a T25 TORX driver ,
tighten the screws to 4.77 N-m (42 in-lb).
Reconnect all cables to the XMI front panel.
T o a v oid blocking exhaust air from the XMI, be certain that the XMI
power cable is routed to the outside of the XMI at the back of the
r ack.
See photographs B through D of Figure 2-19 Reinstalling the XMI on page
2- 44 .
This step is optional and is only performed if there is
a desire to remove the carrier strips from the frame.
Remove the carrier strips from the frame as follows:
• Using a 10 mm socket and ratchet, loosen and remove the 8 nuts that
secure each carrier strip to the frame.
• Remove the carrier strip.
Procedural reference diagrams
The following diagrams help clarify certain steps in Procedure 2 -4 .
• Figure 2 -15 Hanger screw layout for UBS Macro carrier strip assembly on page 2 - 40
• Figure 2 -16 Removing the XMI from the carrier strip assembly on page 2 - 41
• Figure 2 -17 Lifting and hanging the carrier strip assembly on the rack (XMI shown
removed) on page 2 - 42
• Figure 2 -18 Carrier strip assembly keyhole screw locations on page 2 - 43
• Figure 2 -19 Reinstalling the XMI on page 2 - 44
68P09283A62 -2 2 -39
PRELIMINARY A UG 2007
Page 26
T ask 5: R ack Mounting for Low -Capacit y Fr ame Chapter 2: UBS Macro B T S Installation Procedure
Hanger Screw Layout for UBS
Carrier Strip Assembly
Hanger Screw
(Detail A)
NOTE
1. All dimensions are in millimeters
2. 1800 mm high rack shown. Dimension and hanger screw locations are also applicable for the 1400 mm rack
ti-cdma-06012.eps
Detail A
Hanger Screw Extension
95.25
7
Figure 2 -15 shows hanger screw layout used for mounting the UBS Macro carrier strip assembly
onto a 1400 mm or 1800 mm high EIA 19 -inch rack.
Figure 2 -15 Hanger screw la y out for UBS Macro carrier strip assembly
2 -40 68P09283A62 -2
PRELIMINARY A UG 2007
Page 27
R20 1X UBS Macro B T S Hardw are Installation T ask 5: R ack Mounting for Low -Capacit y Fr ame
ti-cdma-06028.eps
A B
D
C
Figure 2 -16 shows the optional removal of the XMI from the UBS Macro carrier strip assembly
just prior to rack mounting the carrier strip assembly .
Figure 2 -16 R emo ving the XMI from the carrier strip assembly
68P09283A62 -2 2 -41
PRELIMINARY A UG 2007
Page 28
T ask 5: R ack Mounting for Low -Capacit y Fr ame Chapter 2: UBS Macro B T S Installation Procedure
Figure 2 -17 shows two people lifting and hanging the UBS Macro carrier strip assembly on
the rack.
Figure 2 -17 Lifting and hanging the carrier strip assembly on the r ack (XMI shown
remo v ed)
2 -42 68P09283A62 -2
PRELIMINARY A UG 2007
Page 29
R20 1X UBS Macro B T S Hardw are Installation T ask 5: R ack Mounting for Low -Capacit y Fr ame
ti-cdma-05870.eps
Bottom keyhole of carrier strip
located on hanger screw
NOTE
1. Another carrier strip keyhole/hanger screw is located at the top of the right side carrier strip/rack rail.
The left side carrier strip/rack rail has a top and bottom keyholes/hanger screws at the same heights as the right side.
All four keyholes/hanger screws should be engaged at the same time.
Figure 2 -18 shows the keyhole screw locations in a rack mounted UBS Macro carrier strip
assembly .
Figure 2 -18 Carrier strip assembly k eyhole screw locations
68P09283A62 -2 2 -43
PRELIMINARY A UG 2007
Page 30
T ask 5: R ack Mounting for Low -Capacit y Fr ame Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-06030.eps
A B
C
D
Figure 2 -19 shows how to reinstall the XMI into the frame if the XMI was previously removed
from the UBS Macro carrier strip assembly .
Figure 2 -19 R einstalling the XMI
2 -44 68P09283A62 -2
PRELIMINARY A UG 2007
Page 31
R20 1X UBS Macro B T S Hardw are Installation T ask 6: Expanding the Low -capacit y Fr ame
Task 6: Expanding the Low -capacity Frame
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
If the initial UBS Macro BTS installation is for a low -capacity frame configuration,
skip this task and go to T ask 7: Cabling the Optional PSM Shelf on page 2 - 46 .
P erform this task only if the initial UBS Macro BTS installation is for a mid -capacity
frame configuration.
Objective
■
■
The objective of T ask 6 is to install the additional equipment required to expand the UBS Macro
BTS low -capacity starter/expansion frame to the mid -capacity frame configuration.
Currently a UBS Macro BTS low -capacity starter/expansion frame can only be
expanded to mid -capacity . In the future, the low -capacity starter/expansion frames
and mid -capacity frames will be expandable to high -capacity .
Procedure
Go to Chapter 3 Low -to -Mid Capacity Frame Expansion Procedures and perform all of the
applicable procedures for expanding the low -capacity UBS Macro BTS starter/expansion frame
to the mid -capacity frame configuration.
A fter all of the additional expansion equipment is installed, go to T ask 7: Cabling the Optional
PSM Shelf on page 2 - 46 and continue performing the remaining tasks in sequential order .
68P09283A62 -2 2 -45
PRELIMINARY A UG 2007
Page 32
T ask 7: Cabling the Optional PSM Shelf Chapter 2: UBS Macro B T S Installation Procedure
Task 7: Cabling the Optional PSM Shelf
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objectives of this procedure are to perform T asks 7:
• F or -48 V DC or 220 V AC UBS only .
Connect the +27 V DC power output cable from the rear of the PSM shelf to the +27 V DC
power input cable on the rear of the PDU .
• F or -48 V DC or 220 V AC UBS only
Connect the 50 -conductor cable (supplied with PSM shelf) between the PSM shelf front
panel ALARM/CONTROL connector and S SI front panel PSM connector .
■
■
Required items
Procedure
The following items are required:
• 50 -conductor cable (supplied with PSM shelf)
• Flat blade screw driver
Procedure 2 -5 gives the procedure for performing T ask 7.
Procedure 2 -5 Procedure for T ask 7
1
2
Connect the +27 V DC power output cable from the rear of the PSM shelf
to the +27 V DC power input cable on the rear of the PDU . Mate Orange
connectors together .
Connect the 50-conductor cable (supplied with PSM shelf) between the PSM
shelf front panel ALARM/CONTROL connector and S SI front panel PSM
connector . Refer to Figure 2-3 and Figure 2-4 for the connector locations on
the PSM shelf front panel and on the S SI.
2 -46 68P09283A62 -2
PRELIMINARY A UG 2007
Page 33
R20 1X UBS Macro B T S Hardw are Installation T asks 8 -9: Connecting TX/RX Antennas
Tasks 8 -9: Connecting TX/RX Antennas
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objectives of performing T asks 8 -9 are as follows:
• Install the external antenna cables to the Integrated Duplexer RX Filters (IDRFs).
• Install terminators on the IDRFs.
The site configuration/characteristics determines the IDRF usage.
Required items
■
■
The following items are required:
• External TX and RX 50 Ohm coaxial cables with type N connectors (customer supplied)
• 0.25 W , 50 Ohm, SMA -type male terminators (customer supplied) for unused directional
• 50 W N -type male terminator (customer supplied) for unused TX/RX connectors
• SMA breakover wrench
• 19 mm open–end hex wrench (N–type connector)
Location of antenna connectors
The top view of Figure 2 -1 and Figure 2 -2 show the location of the UBS Macro BTS antenna
connectors on the top of the IDRF .
Procedure
The procedure for performing the T asks 8 -9 is as follows.
coupler port connectors
Procedure 2 -6 Procedure for T asks 8 -9
1
68P09283A62 -2 2 -47
Route the customer supplied TX/RX main and RX diversity antenna cables
to the top of the Integrated Duplexer RX Filters (IDRFs), located at the
top of the frame.
Continued
PRELIMINARY A UG 2007
Page 34
T asks 8 -9: Connecting TX/RX Antennas Chapter 2: UBS Macro B T S Installation Procedure
Procedure 2 -6 Procedure for T asks 8 -9 (Continued)
2
3
4
Connect each antenna cable to the corresponding IDRF type N connector .
Refer to Figure 2-1 or Figure 2-2 , whichever is applicable, for the location of
the UBS Macro BTS antenna connectors on the top of the IDRF . Using a 19
mm open–end hex wrench, tighten the cable connectors to 4.3 N-m (38 in-lb).
The IDRFs are not labeled for a sector . T o determine the sector
for each IDRF , look at the color code of the XMI TX and RX cables
connected to the bottom of the IDFR. Refer to T able 2-2 for the
mapping of the cable color to the sector (Red = sector 1, Blue =
sector 2, Y ellow = sector 3). The sectors can also be determined
by tracing those XMI cables back to the XMI TX and RX ports,
which are labeled as TX1 and RX1 for sector 1, TX2 and RX2 for
sector 2, and TX3 and RX3 for sector 3.
Connect customer supplied 0.25 W , 50 Ohm, SMA-type terminators to any
unused directional coupler port connectors on the top of the IDRFs.
F or any unused TX/RX connector on an IDRF , install a 50 W N-type
terminator (customer supplied).
2 -48 68P09283A62 -2
PRELIMINARY A UG 2007
Page 35
R20 1X UBS Macro B T S Hardw are Installation T asks 10 -13: Connecting RGPS , Spans, Customer Alarms
Tasks 10 -13: Connecting RGPS, Spans, Customer
Alarms
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The S SI pro vides only secondary surge protection for the RGPS and T1/E1 span
connections. The customer is responsible for pro viding primary surge protection.
The objectives of performing T asks 10–13 are as follows:
• Install RGPS cable AA between the RGPS cable lightning arrester and UBS Macro BTS .
■
■
• Install T1/E1 balanced Span I/O cable (W) between the UBS Macro BTS the site span line
interconnect equipment.
• Install E1 unbalanced Span I/O coaxial cables (customer supplied) between the UBS Macro
BTS the site span line interconnect equipment.
• Install Customer Alarm Input/Output (IP/OP) cables (X) between the UBS Macro BTS the
Customer IP/OP interconnect equipment.
The site configuration/characteristics determines whether the cables in T asks 10 -13 are to be
installed.
Cabling options
The site characteristics determine the use of cables AA, W and X.
The RGPS cable (AA) is optional and used only when the optional RGPS head is used.
The T1/E1 balanced Span I/O cable (W) can carry up to 8 spans, but the UBS Macro BTS
currently supports only up to 4 spans. This is also true for E1 unbalanced Span I/O coaxial
cables (customer supplied).
F or Span I/O cable (W), the minimum size of span line wires is 26 A WG .
The usage and quantity of Customer Alarm Input/Output (IP/OP) cables (X) is determined by the
customer .
68P09283A62 -2 2 -49
PRELIMINARY A UG 2007
Page 36
T asks 10 -13: Connecting RGPS , Spans, Customer Alarms Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05692.eps
LOOSE WIRES, NO CONNECTOR
37-Pin-Type
(Male)
1
19
37
20
Required items
The following items are required:
• Cable AA - P art number 3086433H12
• Cable W - P art number CGDS19797321
• Cable X - P art number CGDS19797321
All S SI cable connectors with jack -screws require a flat -blade driver and should be
tightened to 1.02 N -m (9 in -lb).
Location of cables AA, W and X
Figure 2 -3 shows the connector locations on the front panel of the S SI for: RGPS cable (AA),
T1/E1 balanced span line cable (W), E1 unbalanced span line coaxial cables, and customer
alarm cable (X).
The optional RGPS cable (AA) has a 15 -pin D -connector on one end that connects to the RGPS
connector , located on the front of the S SI. The other cable end has loose wires. This end is
routed to the RGPS lightning arrester , where the wires connect. Refer to Figure 2 -6 through
Figure 2 -11 , T able 2 -9 and T able 2 -10 for RGPS cable (AA) details.
Details for cables (W) and (X ) are provided in this task section.
Balanced T1/E1 cable (W) details
Figure 2 -20 and T able 2 -11 show the pin and signal information for cable W .
Figure 2 -20 T1/E1 balanced span line cable (W) pin numbering
2 -50 68P09283A62 -2
Figure 2 -20 shows E1 unbalanced 75 -Ohm BNC connectors and labeling on the daughter card.
PRELIMINARY A UG 2007
Page 37
R20 1X UBS Macro B T S Hardw are Installation T asks 10 -13: Connecting RGPS , Spans, Customer Alarms
T able 2 -11 also shows the correlation between spans and the E1 unbalanced Span I/O coaxial
BNC connectors.
Table 2 -11 T1/E1 I/O cable W (span) signal and pin information
T1/E1 Balanced Span 36-Cond
Span
number
1
2
3
4
5
6
7
Signal name
TX1_TIP 1
TX1_RING 20
RX1_TIP 12
RX1_RING 30
TX2_TIP 2
TX2_RING 21
RX2_TIP 13
RX2_RING 31
TX3_TIP 3
TX3_RING 22
RX3_TIP 14
RX3_RING 32
TX4_TIP 4
TX4_RING 23
RX4_TIP 15
RX4_RING 33
TX5_TIP 5
TX5_RING 24
RX5_TIP
RX5_RING 34
TX6_TIP 6
TX6_RING 25
RX6_TIP 17
RX6_RING 35
TX7_TIP 7
TX7_RING 26
RX7_TIP
RX7_RING 36
Shielded T wisted Pair Cable (W)
37-Pin D-Sub Connector
Pin
16
18
W ire Color
White/Blue
Blue/White
Black/Orange
Orange/Black
White/Orange
Orange/White
Black/Green
Green/Black
White/Green
Green/White
Black/Brown
Brown/Black
White/Brown
Brown/White
Black/Gray
Gray/Black
White/Gray
Gray/White
Y ellow/Blue
Blue/Y ellow
Red/Blue
Blue/Red
Y ellow/Orange
Orange/Y ellow
Red/Orange
Orange/Red
Y ellow/Green
Green/Y ellow
E1 Unbalanced
75-Ohm Coaxial Cable
BNC Connection
(RING is GND/shield)
TX1
RX1
TX2
RX2
TX3
RX3
TX4
RX4
TX5
RX5
TX6
RX6
TX7
RX7
Continued
68P09283A62 -2 2 -51
PRELIMINARY A UG 2007
Page 38
T asks 10 -13: Connecting RGPS , Spans, Customer Alarms Chapter 2: UBS Macro B T S Installation Procedure
Table 2 -11 T1/E1 I/O cable W (span) signal and pin information (Continued)
T1/E1 Balanced Span 36-Cond
Span
number
8
Signal name
TX8_TIP 8
TX8_RING 27
RX8_TIP 19
RX8_RING 37
Ground
Ground
Not
Connected
Ground
Ground
Shielded T wisted Pair Cable (W)
37-Pin D-Sub Connector
Pin
9
28
10
11
29
W ire Color
Red/Green
Green/Red
Y ellow/Brown
Brown/Y ellow
Red/Brown
Brown/Red
Black/Blue
Blue/Black
Customer alarm input/output (IP/OP) cable (X) details
E1 Unbalanced
75-Ohm Coaxial Cable
BNC Connection
(RING is GND/shield)
TX8
RX8
Alarm connectors
There are two ALARM connectors on the UBS Macro S SI:
• CUSTOMER IP 1 -12 OP 1 -4 connector
• CUSTOMER IP 13 -24 OP 5 -8 connector
Each ALARM connector provides 12 inputs and 4 outputs. A total of 24 inputs and 8 outputs are
available.
Function
ALARM connectors provide for Customer Defined Alarm Inputs and Outputs. The customer can
connect BTS site alarm input sensors and output devices to the UBS Macro BTS , thus providing
alarm reporting of active sensors as well as controlling output devices.
The S SI detects signals from customer input sensors and reports the detected signals to the
DMI controller , which in turn reports the detected alarm to the OMC -R, where it is displayed as
defined by the customer .
The S SI also provides switched relay contacts to customer output devices. The S SI controls
relay contacts according to output control signals from the DMI controller , in response to
customer defined commands entered at the OMC -R.
2 -52 68P09283A62 -2
PRELIMINARY A UG 2007
Page 39
R20 1X UBS Macro B T S Hardw are Installation T asks 10 -13: Connecting RGPS , Spans, Customer Alarms
Input connections
Each input consists of a wire/pin pair (that is, input/Gnd). T o ensure proper operation, each
pair to be used must be connected to an external sensor that provides a dry -contact closure.
The customer sensor output connects between an optically isolated 5 V DC signal and an
isolated return.
F or an OPEN circuit (logic 0 ) between pins:
• There is 10 K Ohms or greater across the input pair .
• The signal to ground voltage is +5 V DC .
F or a CLOSED circuit (logic 1 ) between pins:
• There is 1 K Ohms or less across the input pair .
• The signal to ground current is a maximum of 9 mA.
Either of the above states can be defined by the customer in system software as an alarm
condition.
Output connections
Pins and signals
Each output consists of 3 -wires/pins:
• COM
• NC
• NO
The customer output device control inputs connect between the common (COM) and either the
normally closed (NC) or normally open (NO) contacts of a relay . The NC and NO state for relay
contacts occurs when the relay coil is not energized.
Relay contacts are load rated for a maximum of 1 A at 24 V DC and 0.5 A at 50 V DC .
The toggling of relay contacts to the opposite state is controlled by system software.
Figure 2 -21 , T able 2 -12 and T able 2 -13 show the pin and signal information for cable X.
68P09283A62 -2 2 -53
PRELIMINARY A UG 2007
Page 40
T asks 10 -13: Connecting RGPS , Spans, Customer Alarms Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05692.eps
LOOSE WIRES, NO CONNECTOR
37-Pin-Type
(Male)
1
19
37
20
Figure 2 -21 Customer alarm cable (X) pin numbering
Table 2 -12 Customer alarm cable (X) pinout for customer IP 1 -12 OP 1 -4
D-Sub Pin
number
37-Pin
1 Customer
Signal
Description
W ire Color
White/Blue
D-Sub Pin
number
37Pin
20
Signal
Description
Input 1 Gnd Blue/White
W ire Color
Input 1
2 Customer
White/Orange
21
Input 2 Gnd Orange/White
Input 2
3 Customer
White/Green
22
Input 3 Gnd Green/White
Input 3
4 Customer
White/Brown
23
Input 4 Gnd Brown/White
Input 4
5
Customer
White/Gray
24
Input 5 Gnd Gray/White
Input 5
6 Customer
Red/Blue
25
Input 6 Gnd Blue/Red
Input 6
7
Customer
Red/Orange
26
Input 7 Gnd Orange/Red
Input 7
8 Customer
Red/Green
27
Input 8 Gnd Green/Red
Input 8
9 Customer
Red/Brown
28
Input 9 Gnd Brown/Red
Input 9
10
Not
Connected
29 Customer
Blue/Black
Output NC
1
11 Customer
Black/Blue
Output
NO 1
12 Customer
Output
Black/Orange
NO 2
30 Customer
Orange/Black
Output
Common 1
31 Customer
Green/Black
Output
Common 2
Continued
2 -54 68P09283A62 -2
PRELIMINARY A UG 2007
Page 41
R20 1X UBS Macro B T S Hardw are Installation T asks 10 -13: Connecting RGPS , Spans, Customer Alarms
Table 2 -12 Customer alarm cable (X) pinout for customer IP 1 -12 OP 1 -4 (Continued)
D-Sub Pin
number
37-Pin
13 Customer
14 Customer
15 Customer
16 Customer
17 Customer
18 Customer
19 Customer
Description
Input 10
Input 11
Input 12
Output
Output
Output
Output
Signal
NC 2
NO 3
NO 4
NC 4
W ire Color
Black/Green
Black/Brown
Black/Gray
Y ellow/Blue
Y ellow/Orange
Y ellow/Green
Y ellow/Brown
37Pin
D-Sub Pin
number
32 Customer
33 Customer
34 Customer
35 Input 10
36 Input 11
37 Input 12
Signal
Description
Output NC
3
Output
Common 3
Output
Common 4
Gnd
Gnd
Gnd
W ire Color
Brown/Black
Gray/Black
Blue/Y ellow
Orange/Y ellow
Green/Y ellow
Brown/Y ellow
Table 2 -13 Customer alarm cable (X) pinout for customer IP 13 -24 OP 5 -8
D-Sub Pin
number
37-Pin
1 Customer
2 Customer
3 Customer
4 Customer
5
6 Customer
7
8 Customer
9 Customer
Description
Customer
Customer
Signal
Input 13
Input 14
Input 15
Input 16
Input 17
Input 18
Input 19
Input 20
Input 21
W ire Color
White/Blue
White/Orange
White/Green
White/Brown
White/Gray
Red/Blue
Red/Orange
Red/Green
Red/Brown
37-Pin
D-Sub Pin
number
20 Input 13
21 Input 14
22 Input 15
23 Input 16
24 Input 17
25 Input 18
26 Input 19
27 Input 20
28 Input 21
Signal
Description
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
W ire Color
Blue/White
Orange/White
Green/White
Brown/White
Gray/White
Blue/Red
Orange/Red
Green/Red
Brown/Red
Continued
68P09283A62 -2 2 -55
PRELIMINARY A UG 2007
Page 42
T asks 10 -13: Connecting RGPS , Spans, Customer Alarms Chapter 2: UBS Macro B T S Installation Procedure
Table 2 -13 Customer alarm cable (X) pinout for customer IP 13 -24 OP 5 -8
(Continued)
D-Sub Pin
number
37-Pin
10
11 Customer
12 Customer
13 Customer
14 Customer
15 Customer
16 Customer
17 Customer
18 Customer
19 Customer
Signal
Description
Not
Connected
Output NO 5
Output NO 6
Output NC 6
Output NO 7
Output NO 8
Output NC 8
Input 22
Input 23
Input 24
W ire Color
Black/Blue
Black/Orange
Black/Green
Black/Brown
Black/Gray
Y ellow/Blue
Y ellow/Orange
Y ellow/Green
Y ellow/Brown
37-Pin
D-Sub Pin
number
29 Customer
30 Customer
31 Customer
32 Customer
33 Customer
34 Customer
35 Input 22
36 Input 23
37 Input 24
Signal
Description
Output NC 5
Output
Common 5
Output
Common 6
Output NC 7
Output
Common 7
Output
Common 8
Gnd
Gnd
Gnd
W ire Color
Blue/Black
Orange/Black
Green/Black
Brown/Black
Gray/Black
Blue/Y ellow
Orange/Y ellow
Green/Y ellow
Brown/Y ellow
Procedure
P erform T asks 10 -13 as given in Procedure 2 -7 .
Procedure 2 -7 Procedure for T asks 10 -13
1
2
3
2 -56 68P09283A62 -2
Connect the 15-pin D -connector end of cable (AA) to the RGPS connector on
the front of the S SI. Refer to Figure 2-3 for the connector location on the S SI.
Route the loose end of cable (AA) to the RGPS lightning arrester and connect
the wires there. Refer to Figure 2-6 through Figure 2-11 , T able 2-9 and
T able 2-10 .
F or T1/E1 balanced span line connections, go to step 4 . F or E1 unbalanced
span line connections, go to step 7 .
Continued
PRELIMINARY A UG 2007
Page 43
R20 1X UBS Macro B T S Hardw are Installation T asks 10 -13: Connecting RGPS , Spans, Customer Alarms
Procedure 2 -7 Procedure for T asks 10 -13 (Continued)
4
5
6
7
8
9
10
Connect the 37-pin D -connector end of cable (W) to the SP AN connector on
the front of the S SI. Refer to Figure 2-3 for the connector location on the S SI.
Route the loose end of cable (W) to the customer span line interconnect
equipment and connect the wires. Refer to T able 2-11 .
The UBS Macro BTS currently supports only up to 4 spans.
Go to step 9 .
Connect E1 unbalanced Span I/O coaxial cables (customer supplied) to
the corresponding BNC connector on the S SI E1 daughter card. Refer
to Figure 2-3 for the BNC connector locations on the S SI. Also, refer to
T able 2-11 for correlation between spans and the E1 unbalanced span I/O
coaxial BNC connectors.
Route the other ends of the span I/O coaxial cables to the customer span line
interconnect equipment and connect the cables.
The UBS Macro BTS currently only supports up to 4 spans.
Connect the 37-pin D -connector of the Customer Alarm Input/Output (IP/OP)
cables (X) to the corresponding CUSTOMER IP 1-12 OP 1-4 connector and
CUSTOMER IP 13-24 OP 5-8 connector on the front of the S SI.
Route the loose end of cable (X) to the Customer IP/OP interconnect
equipment and connect the wires. Refer to Figure 2-3 for the CUSTOMER
IP/OP connector locations on the S SI. Also, refer to T able 2-12 and
T able 2-13 .
68P09283A62 -2 2 -57
PRELIMINARY A UG 2007
Page 44
T ask 14: Connecting +27 V DC P ower Chapter 2: UBS Macro B T S Installation Procedure
Task 14: Connecting +27 V DC Power
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
T ask 14 is performed for +27 V DC UBS Macro BTS only .
The objective of this procedure is to perform T ask 14, which includes:
• A ttaching the contact/lugs, connector and cable clamp on the +27 V DC power input
cable wires.
• Connecting the +27 V DC input power cable to the rear of the PDU .
• Routing the loose ends of the wires to the site +27 V DC source for connection.
■
■
Frame power cables and connector information
The wire gauge (that is, diameter) depends on the required length of the DC power cable (DC).
Refer to T able 2 -8 for the correct wire size.
The DC connector contact/lug size depends on the wire gauge used for the DC power cable (DC).
Refer to T able 2 -14 for DC connector contact/lug part information.
In order to minimize current imbalance between the feed (+V) and return ( -V) wires used in
the cable:
• Ensure that the wire size, length and gage, of each wire used in the cable are the same.
• Ensure that contacts/lugs used in the connector are identical and match the gauge of
the wire.
Motorola recommends using 2/0 A WG cables for short cable runs; less than 661.11
cm (21.69 ft).
Table 2 -14 +27 V DC connector (Or ange) parts information
Item Description Part Number
Orange DC connector housing Anderson P ower Products Mfr
P art# 932, or Allied Electronics
Stk# 803-0097
Qty
1 per +27 V DC power feed
Continued
2 -58 68P09283A62 -2
PRELIMINARY A UG 2007
Page 45
R20 1X UBS Macro B T S Hardw are Installation T ask 14: Connecting +27 V DC P ower
Table 2 -14 +27 V DC connector (Or ange) parts information (Continued)
Item Description Part Number
A WG 2/0 connector contact/lug Anderson P ower Products Mfr
P art# 907, or Allied Electronics
Stk# 803-0500
A WG 3/0 connector contact/lug Anderson P ower Products Mfr
P art# 916, or Allied Electronics
Stk# 803-0502
A WG 4/0 connector contact/lug Anderson P ower Products Mfr
P art# 908, or Allied Electronics
Stk# 803-0504
Cable clamp for two single
conductors with hardware
Anderson P ower Products Mfr
P art# 996G1
Required items
The following items are required:
• One +27 V DC P ower Input Cable (DC) - customer supplied. The wire size, length and
gauge, used for cable (DC) depends on site characteristics (see T able 2 -8 ).
Qty
2 per DC connector housing
2 per DC connector housing
2 per DC connector housing
1 per +27 V DC power feed
Motorola recommends the use of Red wire for feed (+V) and Black wire for
return ( -V).
• T wo contacts/lugs – customer supplied. Contact/lug fastens to wire end and is inserted into
DC connector housing. F or contact/lug part number (refer to T able 2 -14 ). Contact/lug size
must match the gauge of the wire being used.
• One DC connector housing – customer supplied. Use Anderson SB350 connector housing
(Orange color) or equivalent.
• DC connector cable clamps for power cable (see T able 2 -14 or T able 2 -15 for part
information).
• Crimper tool - Anderson P ower Products part number 1368 - Hydraulic hand tool,
maximum cable size of 300 MCM
• W ire stripper/cutters.
• Digital Multi -Meter (DMM) Fluke Model 8062A with Y8134 test lead kit or equivalent; used
for precision DC and AC measurements, requiring 4 -1/2 digits.
68P09283A62 -2 2 -59
PRELIMINARY A UG 2007
Page 46
T ask 14: Connecting +27 V DC P ower Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05693.eps
TIE ALL CABLES AT 1 METER INTERVALS
+27 V Power Source
BREAKER 1
+27 V DC
PDU (Top View)
FRONT
REAR
+27 V DC
- 0 V DC
+27 V DC Power Input
Connector (ORANGE)
- 0 V DC
Power cabling and tie down requirements
T o control the inductance at the BTS DC power input due to the spacing between wires used
in the +27 V DC P ower Input Cable (DC), the feed (+V) and return ( -V) wires must be bound
together at intervals of 1 meter or less. Refer to Figure 2 -22 .
Figure 2 -22 +27 V DC power input cable (DC) wire tie -wr ap example
Contact/lug, DC connector housing and PDU input power
Figure 2 -23 shows the lugs and DC connector housing. This figure also shows the location at
which the +27 V DC Input P ower Cable (DC) connects to the rear of the PDU .
2 -60 68P09283A62 -2
PRELIMINARY A UG 2007
Page 47
R20 1X UBS Macro B T S Hardw are Installation T ask 14: Connecting +27 V DC P ower
ti-cdma-05694.eps
PDU
(rear view, shown
partially cut away)
Connector
Housing
(Orange)
(+)
(-)
(-)
Crimp-on
Contact/Lugs
+27 VDC Power
Input (Orange)
RED Wire
(Typical)
(+)
2-Wire +27 VDC
Power Cable
(Customer Supplied)
BLACK WIRE
(Typical)
Cable Clamp
Figure 2 -23 +27 V DC power input cable (DC) connector and connection to PDU
Procedure
P erform the T ask 14 as given in Procedure 2 -8 .
• Do not wear a wrist str ap when servicing the power supplies or power distribution
cabling.
• Ensure that the source for the DC power is in the OFF position.
• Ensure that all of the PDU circuit break ers are OFF .
Procedure 2 -8 Procedure for T ask 14
1
Ensure that the BTS ground cable (DD) is connected between the rack and
the Master Ground Bar (refer to T ask 3).
Continued
68P09283A62 -2 2 -61
PRELIMINARY A UG 2007
Page 48
T ask 14: Connecting +27 V DC P ower Chapter 2: UBS Macro B T S Installation Procedure
Procedure 2 -8 Procedure for T ask 14 (Continued)
2
3
4
5
6
7
8
9
10
1 1
12
13
Ensure that the +27 V DC P ower Input Cable (DC) is NOT connected to the
main +27 V DC power source. Turn OFF the main +27 V DC power source.
Remove the components from the DC connector package.
Strip 35 mm of insulation from the negative (- V) and positive (+V) wires of
the power cable.
Place a DC contact/lug on the negative (- V) and positive (+V) wires of the
power cable. Refer to Figure 2-23 .
Using the appropriate crimping tool, crimp the DC contact/lug on to the
wires.
Observe the negative (- V) and positive (+V) wire polarities and insert the
DC contacts/lugs into the DC connector housing until an audible click is
heard. Refer to Figure 2-23 .
V erify the positive (+V) wire is installed in the positive position and the
negative (- V) wire is installed in the negative (-) position on the connector
housing.
Ensure that the wires are firmly fastened to the DC connector housing.
Tie the positive (+V) and negative (- V) wires of the cable together as shown
in Figure 2-22 .
Route the loose end of the +27 V DC P ower Input Cable (DC) to the site +27
V DC source and connect the wires to the source.
V erify that proper polarity is maintained from the +27 V DC power source to
the UBS Macro BTS .
Use a Digital Multi-Meter (DMM) to measure the voltage
of the DC connector housing that was installed in step 7 .
P erform the following:
• Set the DMM to measure 27 V DC .
• Connect the DMM negative (GND/common) lead to the (-) terminal of
the cable connector .
• Connect the DMM positive lead to the (+) terminal of the cable
connector .
14
15
16
17
18
2 -62 68P09283A62 -2
Turn on the main +27 V DC power source.
Observe the DMM and verify that the voltage is nominally +27 V (range =
+26 to +28 V).
Turn off the main +27 V DC power source.
Disconnect the DMM from the cable connector .
Connect +27 V DC P ower Input Cable (DC) connector to the +27 V DC
input power cable on the rear of the PDU ; Orange connectors mate. Refer
to Figure 2-23 .
PRELIMINARY A UG 2007
Page 49
R20 1X UBS Macro B T S Hardw are Installation T ask 15: Connecting -48 V DC P ower
Task 15: Connecting -48 V DC Power
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
T ask 15 is performed for -48 V DC UBS Macro BTS only .
The objective of this procedure is to perform T ask 15, which includes:
• A ttaching the contact/lugs and connector on the -48 V DC power input cable wires.
• Connecting the -48 V DC input power cable to the rear of the -48 V DC PSM shelf .
• Routing the loose ends of the wires to the site -48 V DC source for connection to the source.
■
■
V erify that the +27 V DC output power cable from the PSM shelf is already
connected to the PDU +27 V DC input power cable. This was performed during
T asks 4 -7.
Frame power cables and connector information
The wire gauge (that is, diameter) depends on the required length of the DC power cable (CC).
Refer to T able 2 -8 for the correct wire size.
The DC connector contact/lug size depends on the wire gauge used for the DC power cable (CC).
Refer to T able 2 -15 for DC connector contact/lug part information.
In order to minimize current imbalance between the feed ( -V) and return (+V) wires used in
the cable:
• Ensure that the wire size, length and gauge, of each wire used in the cable are the same.
• Ensure that contacts/lugs used in the connector are identical and match the gauge of
the wire.
Motorola recommends using 2/0 A WG cables for short cable runs; less than 661.11
cm (21.69 ft).
68P09283A62 -2 2 -63
PRELIMINARY A UG 2007
Page 50
T ask 15: Connecting -48 V DC P ower Chapter 2: UBS Macro B T S Installation Procedure
Table 2 -15 –48 V DC connector (Blue) parts information
Item Description Part Number
Blue DC connector housing Anderson P ower Products Mfr
P art# 912, or Allied Electronics
Stk# 803-0492
A WG 2/0 connector contact/lug Anderson P ower Products Mfr
P art# 907, or Allied Electronics
Stk# 803-0500
A WG 3/0 connector contact/lug Anderson P ower Products Mfr
P art# 916, or Allied Electronics
Stk# 803-0502
A WG 4/0 connector contact/lug Anderson P ower Products Mfr
P art# 908, or Allied Electronics
Stk# 803-0504
Cable clamp for two single
conductors with hardware
Anderson P ower Products Mfr
P art# 996G1
Required items
The following items are required:
• One -48 V DC P ower Input Cable (CC) - customer supplied. The wire size, length and
gauge, used for cable (CC) depends on site characteristics (see T able 2 -8 ).
Qty
1 per –48 V DC power feed
2 per DC connector housing
2 per DC connector housing
2 per DC connector housing
1 per –48 V DC power feed
Motorola recommends the use of blue wire for feed ( -V) and black wire for
return (+V).
• T wo Contacts/Lugs – customer supplied. Contact/lug fastens to wire end and is inserted
into DC connector housing. F or contact/lug part number (refer to T able 2 -15 ). Contact/lug
size must match the gage of the wire being used.
• One DC Connector Housing – supplied with UBS BTS . Use Anderson SB350 connector
housing (blue color) or equivalent.
• Crimper tool - Anderson P ower Products part number 1368 - Hydraulic hand tool,
maximum cable size of 300 MCM
• W ire stripper/cutters.
• Digital Multi -Meter (DMM) Fluke Model 8062A with Y8134 test lead kit or equivalent; used
for precision DC and AC measurements, requiring 4 -1/2 digits.
2 -64 68P09283A62 -2
PRELIMINARY A UG 2007
Page 51
R20 1X UBS Macro B T S Hardw are Installation T ask 15: Connecting -48 V DC P ower
ti-cdma-05695.eps
TIE ALL CABLES AT 1 METER INTERVALS
-48 V Power Source
BREAKER 1
-48 V DC
-48 V DC PSM SHELF
(Top View)
-48 V DC Power Input
Connector (BLUE)
+27 V DC Power Output Connector (ORANGE)
+0 V DC
+0 V DC
REAR
FRONT
-48 V DC
Power cabling and tie down requirements
T o control the inductance at the BTS DC power input due to the spacing between wires used
in the -48 V DC P ower Input Cable (CC), the feed ( -V) and return (+V) wires must be bound
together at intervals of 1 meter or less. Refer to Figure 2 -24 .
Figure 2 -24 48 V DC power input cable (CC) wire tie -wr ap example
Contact/lug, DC connector housing and PDU input power
Figure 2 -25 shows the lugs and DC connector housing. This figure also shows the location at
which the -48 V DC Input P ower Cable (CC) connects to the rear of the PDU .
68P09283A62 -2 2 -65
PRELIMINARY A UG 2007
Page 52
T ask 15: Connecting -48 V DC P ower Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05696.eps
-48 VDC PSM SHELF
(rear view, shown partially cut away)
Connector
Housing (Blue)
(+)
(-)
(-)
???
Crimp-on
Contact/Lugs
-48 VDC Power
Input (Blue)
(+)
2-Wire -48 VDC
Power Cable
(Customer Supplied)
BLACK Wire
(Typical)
BLUE Wire
(Typical)
+27 VDC Power
Output Cable (To PDU)
Cable Clamp
Figure 2 -25 48 V DC power input cable (CC) connector and connection to PSM shelf
Procedure
2 -66 68P09283A62 -2
P erforming T ask 15 as given in Procedure 2 -9 .
• Do not wear a wrist str ap when servicing the power supplies or power distribution
cabling.
• Ensure that the source for the DC power is in the OFF position.
• Ensure that all of the PDU circuit break ers are OFF .
PRELIMINARY A UG 2007
Page 53
R20 1X UBS Macro B T S Hardw are Installation T ask 15: Connecting -48 V DC P ower
Procedure 2 -9 Procedure for T ask 15
1
2
3
4
5
6
7
8
9
10
1 1
12
13
Ensure that the BTS ground cable (DD) is connected between the rack and
the Master Ground Bar (refer to T ask 3).
Ensure that the -48 V DC P ower Input Cable (CC) is NOT connected to the
main -48 V DC power source. Turn OFF the main -48 V DC power source.
Remove the components from the DC connector package.
Strip 35 mm of insulation from the negative (- V) and positive (+V) wires of
the power cable.
Place a DC contact/lug on the negative (- V) and positive (+V) wires of the
power cable. Refer to Figure 2-25 .
Using the appropriate crimping tool, crimp the DC contact/lug on to the
wires.
Observe the negative (- V) and positive (+V) wire polarities and insert the
DC contacts/lugs into the DC connector housing until a click sound is heard.
Refer to Figure 2-25 .
V erify the positive (+V) wire is installed in the positive position and the
negative (- V) wire is installed in the negative (-) position on the connector
housing.
Ensure that the wires are firmly fastened to the DC connector housing.
Tie the positive (+V) and negative (- V) wires of the cable together as shown
in Figure 2-24 .
Route the loose end of the -48 V DC P ower Input Cable (CC) to the site -48 V
DC source and connect the wires to the source.
V erify that proper polarity is maintained from the -48 V DC power source to
the UBS Macro BTS .
Use a Digital Multi-Meter (DMM) to measure the voltage
of the DC connector housing that was installed in step 7 .
P erform the following:
• Set the DMM to measure 48 V DC .
• Connect the DMM negative (GND/common) lead to the (-) terminal of
the cable connector .
• Connect the DMM positive lead to the (+) terminal of the cable
connector .
14
15
16
17
18
68P09283A62 -2 2 -67
Turn on the main –48 V DC power source.
Observe the DMM and verify that the voltage is nominally +48 V (range =
+40 to +60 V).
Turn off the main –48 V DC power source.
Disconnect the DMM from the cable connector .
Connect -48 V DC P ower Input Cable (CC) connector to the -48 V DC input
power connector on the rear of the PSM shelf; blue connectors mate. Refer
to Figure 2-25 .
PRELIMINARY A UG 2007
Page 54
T ask 16: Connecting 220 V AC P ower Chapter 2: UBS Macro B T S Installation Procedure
Task 16: Connecting 220 V AC Power
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
T ask 16 is performed for 220 V AC UBS Macro BTS only .
The objective of this procedure is to perform T ask 16, which includes:
• A ttaching customer supplied wiring and conduit for 220 V AC lines.
• Connecting wires and required insertion bridges to the AC INP UT terminal block on the
rear of the AC PSM shelf .
• Routing the loose ends of the wires to the site 220 V AC source for connection to the source.
■
■
V erify that the +27 V DC output power cable from the PSM shelf is already
connected to the PDU +27 V DC input power cable. This was performed during
T asks 4 -7.
Frame AC power cables and wiring information
The AC PSM shelf and AC PSMs can operate with the following AC power inputs:
• Input AC V oltage R ange: 154 V AC to 300 V AC
• Single -Phase
• 3 -Phase ST AR
• 3 -Phase DEL T A
Consider the following AC power input circuit characteristics:
• The AC PSM shelf terminal block has seven terminals; one for Ground plus six for AC
line wires and insertion bridges.
• The AC PSM shelf terminal block Ground terminal can accommodate a wire size range of
2 A WG to 10 A WG .
• The AC PSM shelf terminal block AC line terminals can accommodate a wire size range of
2 A WG to 10 A WG .
2 -68 68P09283A62 -2
PRELIMINARY A UG 2007
Page 55
R20 1X UBS Macro B T S Hardw are Installation T ask 16: Connecting 220 V AC P ower
• Input AC cable sizing should be determined by Local Electrical Codes, using 90 C minimum
rated conductors, and de–rating for 50 C operation.
• The customer must provide a disconnect device and an over current protection device for
the AC circuit supplying the UBS Macro BTS . A circuit breaker size of 30 Amperes is
recommended, or as appropriate set by Local Electrical Code.
Required items
The following items are required:
• Conduit - customer supplied
• W ire for Ground and AC lines - customer supplied
• Insertion bridges – supplied with AC PSM shelf; two 3 -position bridges and three 2 -position
bridges
• T20 TORX bit with 12 -inch extension
• Flat blade screwdriver
• W ire stripper/cutters
AC PSM shelf AC power input detail
Figure 2 -26 shows the location of the AC PSM shelf AC power input terminals and wiring
details for:
• Single -Phase
• 3 -Phase ST AR
• 3 -Phase DEL T A
68P09283A62 -2 2 -69
PRELIMINARY A UG 2007
Page 56
T ask 16: Connecting 220 V AC P ower Chapter 2: UBS Macro B T S Installation Procedure
ti-cdma-05697.eps
AC PSM Shelf
(rack mounted, rear view, shown partially cut away)
+27 VDC Power
Output Connector
for Battery Backup
AC Input Terminal Block Protective
Cover Box
(See Detail A for Wiring Configurations)
Cond uit /Wi re
Ent ry Hole
2 Screws On Each Side
Secure Protective Cover
Box To PSM Shelf
Detail A - AC Input Terminal Wiring Configurations (protective cover box removed)
Sing le-Phas e
Ground
Ground Ground
AC Inp ut Terminal Block
(te rmi na l sc re w access
hol es on to p)
Two 3 -position
Inse rti on Brid ges
One 3 -p ositi on
Inse rti on Brid ge
Three 2-p ositi on
Inse rti on Brid ges
3-Ph ase S TA R
3-Ph ase DELTA
L3 L2 L1 N
L3 L1 L2
L1 N
Figure 2 -26 AC PSM shelf AC power input terminal block and wiring details
2 -70 68P09283A62 -2
PRELIMINARY A UG 2007
Page 57
R20 1X UBS Macro B T S Hardw are Installation T ask 16: Connecting 220 V AC P ower
Procedure
P erform T ask 16 as given in Procedure 2 -10 .
• Do not wear a wrist str ap while servicing the power supplies or power distribution
cabling.
• Ensure that the source for the AC power is in the OFF position.
• Ensure that all of the PDU circuit break ers are OFF .
Procedure 2 -10 Procedure for T ask 16
1
2
3
4
5
6
7
8
9
10
Set the source for the AC voltage to the OFF position.
Ensure that the BTS ground cable (DD) is connected between the rack and
the Master Ground Bar (refer to T ask 3).
On the rear of the PSM shelf , locate the AC input terminal block cover box.
Using a TORX T20 bit and driver , remove the 4 screws securing the cover
box to the PSM shelf (refer to Figure 2-26 ).
Remove the cover box from the PSM shelf to expose the AC input terminal
block.
A ttach conduit to the cover box.
Route the AC wires and the earth ground wire through the conduit and the
cover box. Leave wires extending to reach the AC input terminal block.
Strip 25 mm of insulation from each of the AC supply line wires and the
earth ground wire.
Locate the ground terminal on the AC input terminal block (refer to
Figure 2-25 ).
Using a flat blade screwdriver , turn the ground terminal screw counter
clockwise (CCW) until the terminal is fully open. Insert the earth ground
wire into the ground terminal. Turn the ground terminal screw clockwise
(CW) to close the terminal and secure the wire. Tighten the terminal screw
to 4.0 - 4.5 N-m (35 - 40 in-lb).
Determine if the AC input terminal block already has insertion bridges
properly installed for the desired AC supply configuration:
• Single-Phase
• 3-Phase ST AR
• 3-Phase DEL T A
Refer to Figure 2-26 as needed.
Continued
68P09283A62 -2 2 -71
PRELIMINARY A UG 2007
Page 58
T ask 16: Connecting 220 V AC P ower Chapter 2: UBS Macro B T S Installation Procedure
Procedure 2 -10 Procedure for T ask 16 (Continued)
1 1
12
13
14
Open the six line terminals as follows:
• Insert a flat blade screwdriver into each screw hole on top of the
terminal block.
• Turn the terminal screw CCW until the terminal is fully open..
F ailure to fully open the terminals can cause improper placement
of the insertion bridges in later steps.
Place an insertion bridge into the proper terminals. While holding the
bridge with one hand, turn the corresponding terminal screws CW until the
bridge is securely clamped.
Repeat step 12 for any remaining terminals requiring an insertion bridge.
Connect the AC supply line wires to the proper terminals as follows:
• Insert a flat blade screwdriver into the appropriate screw hole on top
of the terminal block.
• Turn the terminal screw CCW until the terminal is fully open.
• Insert the appropriate wire into the terminal.
• While holding the wire with one hand, turn the corresponding terminal
screw CW until the wire is securely clamped. Tighten the terminal
screw to 4.0 - 4.5 N-m (35 - 40 in-lb).
Refer to Figure 2-26 as needed.
15
16
17
18
19
20
Repeat step 14 for any unconnected AC supply line wires.
V isually inspect all insertion bridge(s) and wires for proper placement. All
conductors must be inside the clamp of each terminal block.
Place the cover box, with conduit attached, in position over the AC input
terminal block.
Insert the 4 screws to secure the cover box to the PSM shelf . Ensure that
the wires are not pinched.
Using a TORX T20 bit and driver , tighten the 4 screws to 1.6 - 1.8 N-m (14 16 in-lb).
Complete the installation of the AC wiring at the AC P ower source.
2 -72 68P09283A62 -2
PRELIMINARY A UG 2007
Page 59
C h a p t e r
3
Low -to -Mid Capacity Frame Expansion
Procedures
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
The R20 UBS Macro BTS supports single band 800 MHz or 1.9 GHz RF band, up to
two XMIs, up to two DMIs and one S SI. UBS Macro BTS frame configurations with up
to four XMIs and up to five DMIs will be available in the future.
■
■
■
■
68P09283A62 -2 3 -1
A UG 2007 PRELIMINARY
Page 60
Low -to -Mid Capacit y Fr ame Expansion Ov erview Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Low -to -Mid Capacity Frame Expansion Overview
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
This chapter provides information and procedures needed for expanding the low -capacity UBS
Macro BTS starter/expansion frame to the mid -capacity frame configuration.
The mid -capacity frame consists of the low -capacity frame equipment plus the following
additional expansion equipment:
• second XMI, required.
• second DMI, required.
• circuit breaker/output power connector assemblies; one required for each of the following:
second XMI and second DMI.
• second set of IDRFs, required.
• optional RX splitter or RX share cable.
■
■
• second/third PSM, required for –48 V or 220 V AC only . T wo PSMs are required for the mid
Cabling of the RX splitter to the XMIs will be performed after all of the additional expansion
equipment (i.e., XMI, DMI, S SI, circuit breaker/output power connector assemblies, etc.) is
installed in the frame.
How to use this chapter
Typically the installer is directed to this chapter via T ask 6: Expanding the Low -capacity Frame
on page 2 - 45 of Chapter 2 UBS Macro BTS Installation Procedure .
P erform all of the applicable procedures, in this chapter , for expanding the low -capacity UBS
Macro BTS starter/expansion frame to the mid -capacity frame configuration.
A fter all of the additional expansion equipment is installed, go to T ask 7: Cabling the Optional
PSM Shelf on page 2 - 46 of Chapter 2 UBS Macro BTS Installation Procedure , and continue
performing the remaining tasks in sequential order .
capacity configuration and the third PSM is for redundancy .
3 -2 68P09283A62 -2
PRELIMINARY A UG 2007
Page 61
R20 1X UBS Macro B T S Hardw are Installation Adding Circuit Break ers/Connectors to PDU
Adding Circuit Breakers/Connectors to PDU
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this section is to install additional circuit breaker/output power connector
assemblies in the PDU . These additional circuit breaker/output power connector assemblies are
required to allow the PDU to provide DC power to the expansion equipment being added to
the UBS Macro BTS frame.
The circuit breaker/output power connector assemblies are located on the PDU front panel.
Each circuit breaker/output power connector assembly is arranged so that the circuit breaker
is just below the corresponding DC output power connector .
The PDU can be equipped with the following circuit breaker/output power connector assemblies:
• up to four 90A for XMI 1 – XMI 4
■
■
Required items
• up to five 20A for DMI 1 – DMI 5
• up to two 20A for S SI 1 – S SI 2
• up to two 10A for accessory groups ACC 1 – ACC 2
The PDU in the UBS Macro BTS low -capacity starter/expansion frame is already equipped with
the following circuit breaker/output power connector assemblies:
• one 90A for XMI 1
• two 20A for DMI 1 – DMI 2
• one 20A for S SI 1
• zero 10A for no accessories
The type and quantity of circuit breaker/output power connector assemblies required depends
on which circuit breaker/output power connector assemblies are not already equipped in the
PDU , but are needed to support the additional expansion equipment.
The following items are required:
• Appropriate type and quantity of circuit breaker/output power connector assemblies to
be added for expansion purposes
90A circuit breaker/output power connector assembly (Motorola model STLN4093)
20A circuit breaker/output power connector assembly (Motorola model STLN6472)
68P09283A62 -2 3 -3
PRELIMINARY A UG 2007
Page 62
Adding Circuit Break ers/Connectors to PDU Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Mounting screws are provided with each circuit breaker/output power
connector assembly; four screws with the 90A assembly and two screws
with the 20A assembly .
• Side cutters; diagonal pliers or wire cutter
• Small knife
• TORX T25 bit and driver
• T orque driver
Procedure
Procedure 3 -1 contains the steps for adding a circuit breaker/output power connector assembly
to the PDU .
Procedure 3 -1 Adding a Circuit Break er/Output P ower Connector Assembly to the
PDU
Mak e sure DC input power is not applied to the PDU before performing Procedure 3 -1 .
1
2
3
4
Set all PDU front panel circuit breakers to the off (pulled out) position.
Disconnect all DC power cables from the PDU front panel. Dress these cables
away from the PDU front panel.
Remove the PDU front panel as follows:
• See Figure 3-1 Adding a Breaker Assembly Module to the PDU on page
3- 6 photograph A .
• While depressing the retaining tab on the left and right front ends of the
PDU , slide the PDU front panel forward and off of the PDU .
Install the additional circuit breaker/output power connector assemblies in
the required locations on the PDU front panel DC output power bus (see
Figure 3-1 Adding a Breaker Assembly Module to the PDU on page 3- 6
photograph B .
Continued
3 -4 68P09283A62 -2
PRELIMINARY A UG 2007
Page 63
R20 1X UBS Macro B T S Hardw are Installation Adding Circuit Break ers/Connectors to PDU
Procedure 3 -1 Adding a Circuit Break er/Output P ower Connector Assembly to the
PDU (Continued)
5
6
7
P osition the circuit breaker/output power connector assembly as follows:
• Circuit breaker actuator at the bottom and the DC output power
connector at the top
• Circuit breaker actuator facing toward the front of the frame
• Align mounting screw holes of the circuit breaker/output power
connector assembly with the corresponding screw holes on the PDU
front panel DC output power bus.
Insert the supplied mounting screws into the screw holes.
T wo screws on top and bottom for the 90A assembly . One screw on
top and bottom for the 20A assembly .
Using a TORX T25 driver , tighten the mounting screws to 4.8 N-m (42.25
in-lb) ±10%.
Using side cutters, cut out the applicable circuit breaker actuator and the
corresponding connector covers on the PDU front panel (see Figure 3-1
Adding a Breaker Assembly Module to the PDU on page 3- 6 photograph C .
It may be necessary to use a small knife to remove any of the tabs
that do not cut cleanly .
8
9
10
Reattach the PDU front panel to the PDU as follows:
• See Figure 3-1 Adding a Breaker Assembly Module to the PDU on page
3- 6 photograph D .
• Align the PDU front panel with the PDU circuit breaker actuators and
power connectors while inserting the PDU front panel retaining tabs into
the retainer on the left and right front ends of the PDU .
• Slide the PDU front panel onto the front of the PDU .
• Firmly press on the ends of the PDU front panel until each end tab snaps
into place.
Set all PDU front panel circuit breakers to the off (pulled out) position.
Reconnect all DC power cables that were disconnected in step 2 of this
procedure. Make sure that each cable is connected to the proper PDU front
panel power connector .
68P09283A62 -2 3 -5
PRELIMINARY A UG 2007
Page 64
Adding Circuit Break ers/Connectors to PDU Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
ti-cdma-06031.eps
A B
C D
Procedural reference diagram
The following diagram helps clarify certain steps in Procedure 3 -1 .
Figure 3 -1 Adding a Break er Assembly Module to the PDU
3 -6 68P09283A62 -2
PRELIMINARY A UG 2007
Page 65
R20 1X UBS Macro B T S Hardw are Installation Adding an XMI
Adding an XMI
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this section is to mount an additional XMI into the XMI shelf .
Cabling of the additional XMI will be performed after all of the additional expansion
equipment (i.e., IDRFs, DMI, circuit breaker/output power connector assemblies, etc.)
that connects to the additional XMI is installed in the frame.
■
■
Required items
Parts
Manpower
The following applicable additional XMI is required:
• 800 MHz XMI assembly with removable XMI handle attached (Motorola model SGTF4194).
• 1.9 GHz XMI assembly with removable XMI handle attached (Motorola model STWG4000).
The XMI module is hea vy . T wo people are required to lift, carry , or handle the XMI
module.
The XMI weighs 23 -28 kg (50.7 -61.7 lb) depending on the RF band.
68P09283A62 -2 3 -7
PRELIMINARY A UG 2007
Page 66
Adding an XMI Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Tools
The following tools are required:
• TORX T25 bit and driver
• T orque driver
Procedure
Procedure 3 -2 contains the steps for adding a 2nd XMI to the XMI shelf .
Procedure 3 -2 Adding a 2nd XMI to the XMI Shelf
The XMI module is hea vy . T wo people are required to lift, carry , or
handle the XMI module.
• Be sure the remo v able XMI handle is attached to the front of
the XMI before ph ysically handling the module.
• Be sure two people use both hands and wear protectiv e
footwear when handling the XMI.
• Be sure to use two people to support the module while sliding
the module out of or into the shelf slot.
An XMI module that is not in a shelf should alw a ys be set on its
side and nev er on its edge. This will prev ent the XMI module from
tipping o v er and causing damage or injury .
1
2
Remove the XMI from its packaging and inspect it for damage.
XMI 2 mounts in the XMI shelf slot just to the right of XMI 1. XMI
3 mounts in the XMI shelf slot just to the right of XMI 2. XMI 4
mounts in the XMI shelf slot just to the right of XMI 3.
This step requires two people. P erform the following:
Continued
3 -8 68P09283A62 -2
PRELIMINARY A UG 2007
Page 67
R20 1X UBS Macro B T S Hardw are Installation Adding an XMI
Procedure 3 -2 Adding a 2nd XMI to the XMI Shelf (Continued)
• One person grasp the XMI by the handle with both hands. The second
person grasp the XMI fan tray sides with both hands. Using safe lifting
technique (i.e. lift with your legs not your back), pick up the XMI and
carry it over to the front of the frame.
• While one person holds the XMI by the handle with both hands, the
second person supports the bottom of the module with one hand and the
top of the module with the other hand. Lift the XMI into the appropriate
XMI shelf slot rails and gently slide it all of the way into the shelf slot.
3
Insert the four XMI mounting screws; two screws at each of the top and
bottom mounting tabs on the front of the module. Using a T25 TORX driver ,
tighten the screws to 4.8 N-m (42.25 in-lb) ±10%.
Procedural reference diagram
The following diagram helps clarify certain steps in Procedure 3 -2 .
Figure 3 -2 Installing a 2nd XMI
68P09283A62 -2 3 -9
PRELIMINARY A UG 2007
Page 68
Adding a DMI Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Adding a DMI
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this section is to mount an additional DMI into the XMI shelf .
Cabling of the additional DMI will be performed after all of the additional expansion
equipment (i.e., XMI, circuit breaker/output power connector assemblies, etc.) that
connects to the additional DMI is installed in the frame.
■
■
Required items
Parts
The additional DMI is application dependent. Use one of the following factory built DMI
assemblies as applicable:
All models of DMI assemblies include: DMI chassis with controller board, fans and
front panel.
• DMI assembly with one 1X CDMA modem board (Motorola model STLN6681).
• DMI assembly with one EV -DO modem board (Motorola model STLN6682).
• DMI assembly with two 1X CDMA modem boards (Motorola model STLN6683).
• DMI assembly with one 1X CDMA modem board and one EV -DO modem board (Motorola
model STLN6684).
• DMI assembly with two EV -DO modem boards (Motorola model STLN6679).
3 -10 68P09283A62 -2
PRELIMINARY A UG 2007
Page 69
R20 1X UBS Macro B T S Hardw are Installation Adding a DMI
Tools
The following tools are required:
• TORX T25 bit and driver
• T orque driver
• ESD wrist strap
Prerequisite
ESD handling precautions must be adhered to when handling the DMI assembly . W ear
a conductiv e, high impedance wrist str ap during handling.
The procedures in this chapter requires working on or around circuitry that is extremely
sensitive to ESD .
Procedure
Procedure 3 -3 contains the steps for adding a 2nd DMI to the XMI shelf .
Procedure 3 -3 Adding a 2nd DMI to the XMI Shelf
1
2
3
4
Set the additional DMI assembly , in its packaging, near the UBS Macro BTS
frame.
ESD handling precautions must be adhered to during this
procedure. W ear a conductiv e, high impedance wrist str ap .
Plug the end of the ESD wrist strap into the UBS Macro BTS frame ESD jack
This jack is located in the middle of the upper XMI shelf bracket. A ttach
the wrist strap to your wrist.
Remove the additional DMI from its packaging and inspect it for damage.
Install the DMI assembly into the appropriate empty DMI housing in the UBS
Macro BTS frame by performing the following:
1. P osition the DMI assembly on its bottom edge so that the front panel
handle is on the right and the retaining fastener is at the top.
Continued
68P09283A62 -2 3 -11
PRELIMINARY A UG 2007
Page 70
Adding a DMI Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedure 3 -3 Adding a 2nd DMI to the XMI Shelf (Continued)
2. Pick up the DMI assembly with two hands.
3. Insert the rear of the DMI assembly into the empty housing.
4. Slide the DMI assembly completely into the housing (see Figure 3-3
Installing a 2nd DMI on page 3- 13 .
5. Turn the retaining fastener CW (Clockwise) until finger tight to secure
the DMI assembly in the housing.
3 -12 68P09283A62 -2
PRELIMINARY A UG 2007
Page 71
R20 1X UBS Macro B T S Hardw are Installation Adding a DMI
Procedural reference diagram
The following diagram helps clarify certain steps in Procedure 3 -3 .
Figure 3 -3 Installing a 2nd DMI
68P09283A62 -2 3 -13
PRELIMINARY A UG 2007
Page 72
Adding a Second Set of IDRFs Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Adding a Second Set of IDRFs
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this section is to mount a second set of IDRFs into the IDRF shelf .
Cabling of the second set of IDRFs to the second XMI will be performed after all of
the additional expansion equipment (i.e., XMI, DMI, circuit breaker/output power
connector assemblies, etc.) is installed in the frame.
■
■
Required items
Parts
The second set of IDRFs consists of:
• one IDRF for an omni antenna configuration.
• three IDRFs, one per sector , for a 3 -sector antenna configuration.
The second set of IDRFs mounts in the right -half of the IDRF shelf . The second set of IDRFs are
designated as sector 1, 2 and 3 from left to right.
The proper quantity , for omni or 3 -sector antenna configuration, of the following applicable
IDRF is required:
• China Full Band 800 MHz IDRF (Motorola model STFN4009)
• India Full Band 800 MHz IDRF (Motorola model STFN4010)
• US Full Band 800 MHz IDRF (Motorola model STFN4015)
• US A -band 800 MHz IDRF (Motorola model STFN4016)
• US B -band 800 MHz IDRF (Motorola model STFN4017)
• 1.9 GHz IDRF (Motorola model STFG4055)
3 -14 68P09283A62 -2
PRELIMINARY A UG 2007
Page 73
R20 1X UBS Macro B T S Hardw are Installation Adding a Second Set of IDRFs
Tools
The following tools are required:
• TORX T25 bit and driver
• T orque driver
Procedure
Procedure 3 -4 contains the steps for adding a second set of IDRFs to the IDRF shelf .
Procedure 3 -4 Adding a second set of IDRFs to the IDRF shelf
1
2
3
4
Remove the additional IDRFs from their packaging and inspect them for
damage.
While working at the front/top of the UBS Macro BTS frame, pick up an
additional IDRF and mount it into the IDRF shelf as follows:
• P osition the IDRF with the IDRF mounting plate on top/facing upward
and the mounting plate flange is on the right side (see Figure 3-4
Installing the second set of IDRFs on page 3- 16 photograph B ).
• Insert the first IDRF into the sector 1 position on the right half of the top
of the IDRF shelf (see photograph A ).
• Slide the IDRF down into the IDRF shelf .
Repeat step 2 for the remaining IDRFs, but insert them in sector 2 and sector
3 positions.
Insert four mounting screws through each IDRF mounting plate and into the
IDRF shelf . Using a T25 TORX driver , tighten the mounting screws for all of
the additional IDRFs to 4.8 N-m (42.25 in-lb) ±10%.
68P09283A62 -2 3 -15
PRELIMINARY A UG 2007
Page 74
Adding a Second Set of IDRFs Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedural reference diagram
The following diagram helps clarify certain steps in Procedure 3 -4 .
Figure 3 -4 Installing the second set of IDRFs
3 -16 68P09283A62 -2
PRELIMINARY A UG 2007
Page 75
R20 1X UBS Macro B T S Hardw are Installation Adding an Optional RX Splitter
Adding an Optional RX Splitter
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this section is to mount the optional RX splitter onto the bottom of the XMI shelf .
Cabling of the RX splitter to the XMIs will be performed after all of the additional
expansion equipment (i.e., XMI, DMI, circuit breaker/output power connector
assemblies, etc.) is installed in the frame.
■
■
Required items
Parts
Tools
Procedure
The following part is required:
• W ide band (800 MHz through 2.1 GHz RF bands) single band RX splitter (Motorola
model STRG4029)
The following tools are required:
• TORX T25 bit and driver
• T orque driver
Procedure 3 -5 contains the steps for adding the RX splitter to the bottom of the XMI shelf .
Procedure 3 -5 Adding an RX splitter to the XMI shelf
1
68P09283A62 -2 3 -17
Remove the RX splitter from its packaging and inspect it for damage.
Continued
PRELIMINARY A UG 2007
Page 76
Adding an Optional RX Splitter Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedure 3 -5 Adding an RX splitter to the XMI shelf (Continued)
2
3
While working at the front of the UBS Macro BTS frame, pick up the RX
splitter and mount it onto the bottom of the XMI shelf as follows:
• See Figure 3-5 Mounting the RX splitter on page 3- 18 .
• P osition the RX splitter as follows:
RX splitter I/O connectors facing toward front of the frame.
RX splitter mounting tabs, one on each end of splitter , facing up.
In front of the XMI shelf bottom bracket.
• Align the guide pins on each RX splitter mounting tab with the
corresponding hole located on the XMI shelf bottom bracket (see
photograph A ).
• Insert the guide pins into the holes and hold the RX splitter mounting
tabs against the XMI shelf bottom bracket.
• Insert a mounting screw through each RX splitter mounting tab and into
the XMI shelf bottom bracket. (see photograph B ).
Using a T25 TORX driver , tighten the mounting screws to 4.8 N-m (42.25
in-lb) ±10%.
Procedural reference diagram
The following diagram helps clarify certain steps in Procedure 3 -5 .
Figure 3 -5 Mounting the RX splitter
3 -18 68P09283A62 -2
PRELIMINARY A UG 2007
Page 77
R20 1X UBS Macro B T S Hardw are Installation Adding a second/third PSM (–48 V or 220 V AC only)
Adding a second/third PSM (–48 V or 220 V AC only)
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
A second/third PSM is required when expanding a –48 V DC or 220 V AC UBS Macro
BTS frame from low capacity to mid capacity . T wo PSMs are required for the mid
capacity configuration and the third PSM is for redundancy .
Objective
F or –48 V or 220 V AC only , install the appropriate PSM into slot 2. If applicable, remove the
filler plate that covers slot 3 of the PSM shelf and then install the appropriate PSM into slot 3.
■
■
Required items
Parts
Tools
Nev er plug a –48 V DC PSM into a 220 V AC PSM shelf .
Nev er plug a 220 V AC PSM into a -–48 V DC PSM shelf .
Up to two of either the following parts are required:
• –48 V DC P ower Supply Module (–48 V DC PSM) — Motorola model STPN4037
• 220 V AC P ower Supply Module (220 V AC PSM) — Motorola model STPN4036
The following tools are required:
• TORX T25 bit and driver
• T orque driver
68P09283A62 -2 3 -19
PRELIMINARY A UG 2007
Page 78
Adding a second/third PSM (–48 V or 220 V AC only) Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedure
Procedure 3 -6 contains the steps for adding a second/third PSM to the PSM shelf .
Procedure 3 -6 Adding a 2nd/3rd PSM to the PSM shelf
1
2
3
If a PSM is to be installed in PSM shelf slot 3, use a T25 TORX bit and driver
to completely loosen the captive retaining thumbscrew on the filler plate that
covers slot 3 of the PSM shelf . Remove the filler plate.
PSM weighs appro ximately 5 kg. Be careful when handling the PSM
to prev ent damage to the equipment and personal injury .
Install the appropriate PSM into PSM shelf slot 2 and 3 as follows:
1. Grasp the handle on the front panel of the PSM with one hand while
carefully supporting the bottom of the module with the other hand.
2. Properly orient the PSM and insert it into the slot.
3. Slowly slide the module into the shelf until the rear connectors are
fully seated. Make sure that the PSM is fully engaged with the shelf
backplane slot connectors.
Using a T25 TORX bit and torque driver , tighten the captive retaining
thumbscrew to 2.37 N-m (21 in-lb).
3 -20 68P09283A62 -2
PRELIMINARY A UG 2007
Page 79
R20 1X UBS Macro B T S Hardw are Installation Mid -capacit y Expansion Interconnect Cabling
Mid -capacity Expansion Interconnect Cabling
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Objective
The objective of this section is to route and connect all require cabling between the additional
mid -capacity expansion equipment (i.e., 2nd XMI, 2nd DMI, optional RX splitter , circuit
breaker/output power connector assemblies) that is installed in the frame.
The RX splitter is optional equipment for expansion to mid -capacity . An RX share
cable can be used instead of the RX splitter for interconnecting RX RF signals
between XMI 1 and XMI 2.
■
■
Installing DC power cables
Locate the required DC power cables and then perform Procedure 3 -7 through Procedure 3 -8
as needed.
Required DC power cables
• XMI DC power cable (Motorola part number 3088319T03)
• DMI DC power cable (Motorola part number 3088961T05)
DC power cabling procedures
Procedure 3 -7 Installing the XMI 2 DC power cable
1
2
Locate the XMI DC power cable (Motorola part number 3088319T03).
Connect the appropriate end of the XMI DC power cable to the +27 V DC
input power connector on the top of XMI 2 front panel.
Continued
68P09283A62 -2 3 -21
PRELIMINARY A UG 2007
Page 80
Mid -capacit y Expansion Interconnect Cabling Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedure 3 -7 Installing the XMI 2 DC power cable (Continued)
3
4
Route the loose end of the XMI DC power cable as follows:
1. Through the opening above XMI 2 between the XMI shelf and the IDRF
shelf to the back of the XMI shelf .
2. Down and around the left side of the rear of XMI 2.
T o avoid blocking exhaust air from the XMI, the XMI DC power
cable must not be routed directly behind the XMI.
3. Down to the PDU and over the top of the PDU to the PDU front panel.
Connect the loose end of the XMI DC power cable to the XMI 2 DC output
power connector on the PDU front panel.
Procedure 3 -8 Installing the DMI 2 DC power cable
1
2
Locate the DMI DC power cable (Motorola part number 3088961T05).
Connect the appropriate end of the DMI DC power cable to the DMI 2 DC
output power connector on the PDU front panel.
Continued
3 -22 68P09283A62 -2
PRELIMINARY A UG 2007
Page 81
R20 1X UBS Macro B T S Hardw are Installation Mid -capacit y Expansion Interconnect Cabling
Procedure 3 -8 Installing the DMI 2 DC power cable (Continued)
3
4
Route the loose end of the DMI DC power cable as follows:
1. Up the right side of the frame/rack and around to the back of the frame.
2. Through the opening between the XMI shelf and the IDRF shelf and over
the XMI shelf top bracket.
3. Down to the front panel of the appropriate DMI.
Excess cable should be coiled up and placed on top of the XMI
shelf top bracket.
Connect the loose end of the DMI DC power cable to the +27 V DC input
power connector on the front panel of DMI 2.
Installing/Connecting RF cables (XMI to IDRF)
Locate the required RF cables and then perform Procedure 3 -9 and Procedure 3 -10 as needed.
Required RF cables
The required TX RF cables are as follows:
• TX sector -1 RF cable (Motorola part number 3088160T73)
• TX sector -2 RF cable (Motorola part number 3088160T74)
• TX sector -3 RF cable (Motorola part number 3088160T75)
68P09283A62 -2 3 -23
PRELIMINARY A UG 2007
Page 82
Mid -capacit y Expansion Interconnect Cabling Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
RF cabling procedures
P erform Procedure 3 -9 to install the TX RF cables between XMI 2 and the second set of IDRFs.
Procedure 3 -9 Installing TX RF cables
1
2
3
Locate the following TX RF cables:
• TX sector-1 RF cable (Motorola part number 3088160T73)
• TX sector-2 RF cable (Motorola part number 3088160T74)
• TX sector-3 RF cable (Motorola part number 3088160T75)
Install the TX sector-1 RF cable as follows:
1. Connect one end of the cable to the TX1 connector on the XMI 2 front
panel.
2. Route the loose end of the cable through the opening between the XMI
shelf and the IDRF shelf .
3. Loop the cable around under the second set of IDRFs.
4. Connect the loose end of the TX sector-1 RF cable to the TX input
connector on the bottom panel of the sector-1 IDRF of the second set of
IDRFs.
Install the TX sector-2 RF cable as follows:
1. Connect one end of the cable to the TX2 connector on the XMI 2 front
panel.
2. Route the loose end of the cable through the opening between the XMI
shelf and the IDRF shelf .
3. Loop the cable around under the second set of IDRFs.
4. Connect the loose end of the TX sector-2 RF cable to the TX input
connector on the bottom panel of the sector-2 IDRF of the second set of
IDRFs.
4
3 -24 68P09283A62 -2
Install the TX sector-3 RF cable as follows:
1. Connect one end of the cable to the TX3 connector on the XMI 2 front
panel.
2. Route the loose end of the cable through the opening between the XMI
shelf and the IDRF shelf .
3. Loop the cable around under the second set of IDRFs.
4. Connect the loose end of the TX sector-3 RF cable to the TX input
connector on the bottom panel of the sector-3 IDRF of the second set of
IDRFs.
PRELIMINARY A UG 2007
Page 83
R20 1X UBS Macro B T S Hardw are Installation Mid -capacit y Expansion Interconnect Cabling
P erform Procedure 3 -10 to connect the RX RF cables between XMI 2 and the second set of IDRFs.
Procedure 3 -10 Connecting RX RF cables
1
2
3
Disconnect the following RX RF cables from the front panel of XMI 1:
1. Disconnect the end of the 3088160T79 cable from the RX1 D connector
on the XMI 1 front panel.
2. Disconnect the end of the 3088160T80 cable from the RX2 D connector
on the XMI 1 front panel.
3. Disconnect the end of the 3088160T81 cable from the RX3 D connector
on the XMI 1 front panel.
Connect the RX RF cables that were disconnected in step 1 to the front panel
of XMI 2 as follows:
1. Connect the loose end of the 3088160T79 cable to the RX1 D connector
on the XMI 2 front panel.
2. Connect the loose end of the 3088160T80 cable to the RX2 D connector
on the XMI 2 front panel.
3. Connect the loose end of the 3088160T81 cable to the RX3 D connector
on the XMI 2 front panel.
Disconnect the following RX RF cables from the bottom of the first (original)
set of IDRFs as follows:
1. Disconnect the end of the 3088160T79 cable from the RX DIV connector
on the bottom panel of the sector-1 IDRF of the first set of IDRFs.
2. Disconnect the end of the 3088160T80 cable from the RX DIV connector
on the bottom panel of the sector-2 IDRF of the first set of IDRFs.
3. Disconnect the end of the 3088160T81 cable from the RX DIV connector
on the bottom panel of the sector-3 IDRF of the first set of IDRFs.
4
Connect the RX RF cables that were disconnected in step 3 to the bottom
panel of the second set of IDRFs as follows:
1. Connect the loose end of the 3088160T79 cable to the RX MAIN
connector on the bottom panel of the sector-1 IDRF of the second set of
IDRFs.
2. Connect the loose end of the 3088160T80 cable to the RX MAIN
connector on the bottom panel of the sector-2 IDRF of the second set of
IDRFs.
3. Connect the loose end of the 3088160T81 cable to the RX MAIN
connector on the bottom panel of the sector-3 IDRF of the second set of
IDRFs.
68P09283A62 -2 3 -25
PRELIMINARY A UG 2007
Page 84
Mid -capacit y Expansion Interconnect Cabling Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Installing XMI to DMI cables
Locate the required XMI to DMI cables and then perform Procedure 3 -11 .
F or the mid -capacity frame, there are four 3088791T02 cables used to interconnect
XMIs to DMIs. One of these cables is already installed/connected in the low -capacity
configuration.
Required XMI to DMI cables
The required XMI to DMI cables are as follows:
• Three XMI to DMI cables (Motorola part number 3088791T02)
XMI to DMI cabling procedure
P erform Procedure 3 -11 to install the XMI to DMI cables between two XMIs and two DMIs.
Procedure 3 -11 Installing XMI to DMI cables
1
2
3
4
V erify that an XMI to DMI cable (Motorola part number 3088791T02) is
already installed/connected between XMI 1 front panel connector HSL 1 and
DMI 1 front panel connector XMI 1/BSI.
Locate the following cables:
• Three XMI to DMI cables (Motorola part number 3088791T02)
Install an XMI to DMI cable between XMI 1 and DMI 2 as follows:
1. Connect the appropriate end of the 3088791T02 cable to the HSL 2
connector on the XMI 1 front panel.
2. Route the loose end of the cable up above XMI 1, through the opening
between the XMI shelf and IDRF shelf , and behind the hooks on the
top XMI shelf bracket. Continue routing over to the XMI shelf DMI slot
and then down to DMI 2.
3. Connect the loose end of the 3088791T02 cable to the XMI 1/BSI
connector on the DMI 2 front panel.
Install an XMI to DMI cable between XMI 2 and DMI 1 as follows:
1. Connect the appropriate end of the 3088791T02 cable to the HSL 1
connector on the XMI 2 front panel.
Continued
3 -26 68P09283A62 -2
PRELIMINARY A UG 2007
Page 85
R20 1X UBS Macro B T S Hardw are Installation Mid -capacit y Expansion Interconnect Cabling
Procedure 3 -11 Installing XMI to DMI cables (Continued)
2. Route the loose end of the cable up above XMI 2 through the opening
between the XMI shelf and IDRF shelf , and behind the hooks on the
top XMI shelf bracket. Continue routing over to the XMI shelf DMI slot
and then down to DMI 1.
3. Connect the loose end of the 3088791T02 cable to the XMI 2 connector
on the DMI 1 front panel.
5
Install an XMI to DMI cable between XMI 2 and DMI 2 as follows:
1. Connect the appropriate end of the 3088791T02 cable to the HSL 2
connector on the XMI 2 front panel.
2. Route the loose end of the cable up above XMI 2 through the opening
between the XMI shelf and IDRF shelf , and behind the hooks on the
top XMI shelf bracket. Continue routing over to the XMI shelf DMI slot
and then down to DMI 2.
3. Connect the loose end of the 3088791T02 cable to the XMI 2 connector
on the DMI 2 front panel.
Installing DMI to SSI cables
Locate the required DMI to S SI cables and then perform Procedure 3 -12 .
F or the mid -capacity frame, there are two 3088792T01 cables used to interconnect
S SI 1 to DMI 1 and DMI 2. One of these cables is already installed/connected in
the low -capacity configuration.
Required DMI to SSI cables
The required DMI to S SI cable is as follows:
• One DMI to S SI cable (Motorola part number 3088792T01)
DMI to SSI cabling procedure
P erform Procedure 3 -12 to install the DMI to S SI cable between S SI 1 and DMI 2.
Procedure 3 -12 Installing DMI 2 to S SI 1 cable
Continued
68P09283A62 -2 3 -27
PRELIMINARY A UG 2007
Page 86
Mid -capacit y Expansion Interconnect Cabling Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
1
2
3
V erify that a DMI to S SI cable (Motorola part number 3088792T01) is already
installed/connected between DMI 1 front panel connector IDI/S SI 1 and S SI
1 front panel connector DMI 1/IDI .
Locate the following cables:
• One DMI to S SI cable (Motorola part number 3088792T01)
Install the DMI to S SI cable between DMI 2 and S SI 1 as follows:
1. Connect the appropriate end of the 3088792T01 cable to the IDI/S SI 1
connector on the DMI 2 front panel.
2. Route the loose end of the cable up above the XMI shelf DMI slot,
through the opening between the XMI shelf and the IDRF shelf , and
out the right side of the opening. Continue routing upwards along the
right rack rail and over in to S SI 1.
Excess cable should be coiled up and placed on top of the
XMI shelf top bracket.
3. Connect the loose end of the 3088792T01 cable to the DMI 2 connector
on the S SI 1 front panel.
Installing RX splitter to XMI RX RF cables or RX share cable
Expansion to mid -capacity requires interconnection of RX RF signals between XMI 1 and XMI 2.
This can be accomplished by using an optional RX splitter or RX share cable.
If the optional RX splitter is used, locate the required RX splitter to XMI RX RF cables and then
perform Procedure 3 -13 .
If the optional RX splitter is not used, locate the required RX share cable and then perform
Procedure 3 -14 .
Required RX splitter to XMI RX RF cables
The required RX splitter to XMI RX RF cables are as follows:
• RX splitter to XMI 1 RX RF cable (Motorola part number 3088407T10)
• RX splitter to XMI 2 RX RF cable (Motorola part number 3088407T11)
3 -28 68P09283A62 -2
PRELIMINARY A UG 2007
Page 87
R20 1X UBS Macro B T S Hardw are Installation Mid -capacit y Expansion Interconnect Cabling
Required RX share cable
The required RX share cable is as follows:
• RX share cable (Motorola part number SGLN6345)
The RX share cable cross -connects XMI 1 RX EXP OUT to XMI 2 RX EXP IN
and XMI 2 RX EXP OUT to XMI 1 RX EXP IN .
RX splitter to XMI cabling procedure
P erform Procedure 3 -13 to install the RX splitter to XMI RX RF cables between RX splitter and
the two XMIs.
Procedure 3 -13 Installing RX splitter to XMI RX RF cables
1
2
Locate the following cables:
• RX splitter to XMI 1 RX RF cable (Motorola part number 3088407T10)
• RX splitter to XMI 2 RX RF cable (Motorola part number 3088407T11)
Install the RX splitter to XMI 1 RX RF cable (Motorola part number
3088407T10) as follows:
The 3088407T10 cable contains two separate cables bundled
together . The 3088407T10 cable has two connectors on each end
of the bundle. The ends of each separate cable can be determined
by observation.
1. P osition the 3088407T10 cable so that two connectors on one end of the
bundle are in front of XMI 1 (i.e., XMI end) and the two connectors on
the other end of the bundle are in front of the RX splitter .
2. Connect an XMI end connector to the RX EXP OUT connector on the
XMI 1 front panel.
3. Connect the loose end of the same separate cable to the XMI 1 RX EXP
IN connector on the RX splitter front panel.
4. Connect the remaining XMI end connector to the RX EXP IN connector
on the XMI 1 front panel.
Continued
68P09283A62 -2 3 -29
PRELIMINARY A UG 2007
Page 88
Mid -capacit y Expansion Interconnect Cabling Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
Procedure 3 -13 Installing RX splitter to XMI RX RF cables (Continued)
5. Connect the loose end of the same separate cable to the XMI 1 RX EXP
OUT connector on the RX splitter front panel.
3
Install the RX splitter to XMI 2 RX RF cable (Motorola part number
3088407T11) as follows:
The 3088407T11 cable contains two separate cables bundled
together . The 3088407T11 cable has two connectors on each end
of the bundle. The ends of each separate cable can be determined
by observation.
1. P osition the 3088407T11 cable so that two connectors on one end of the
bundle are in front of XMI 2 (i.e., XMI end) and the two connectors on
the other end of the bundle are in front of the RX splitter .
XMI 1 to XMI 2 RX cabling procedure
P erform Procedure 3 -14 to install the RX share cable to interconnect RX RF signals between
XMI 1 and XMI 2.
Procedure 3 -14 Installing RX share cable
1
2. Connect an XMI end connector to the RX EXP OUT connector on the
XMI 2 front panel.
3. Connect the loose end of the same separate cable to the XMI 2 RX EXP
IN connector on the RX splitter front panel.
4. Connect the remaining XMI end connector cable to the RX EXP OUT
connector on the XMI 2 front panel.
5. Connect the loose end of the same separate cable to the XMI 2 RX EXP
IN connector on the RX splitter front panel.
Locate the following cable:
• RX share cable (Motorola part number SGLN6345)
Continued
3 -30 68P09283A62 -2
PRELIMINARY A UG 2007
Page 89
R20 1X UBS Macro B T S Hardw are Installation Mid -capacit y Expansion Interconnect Cabling
Procedure 3 -14 Installing RX share cable (Continued)
The SGLN6345 cable contains two separate cables bundled
together . The SGLN6345 cable has four ends with a connector on
each end.
The ends of the RX share cable are labeled as follows:
• XMI 1 RX EXP OUT
• XMI 1 RX EXP IN
• XMI 2 RX EXP OUT
• XMI 2 RX EXP IN
2
Install the RX share cable as follows:
1. Connect the XMI 1 RX EXP OUT cable connector to the RX EXP OUT
connector on the XMI 1 front panel.
2. Connect the XMI 1 RX EXP IN cable connector to the RX EXP IN
connector on the XMI 1 front panel.
3. Connect the XMI 2 RX EXP OUT cable connector to the RX EXP OUT
connector on the XMI 2 front panel.
4. Connect the remaining XMI 2 RX EXP IN cable connector to the RX
EXP IN connector on the XMI 2 front panel.
68P09283A62 -2 3 -31
A UG 2007 PRELIMINARY
Page 90
Mid -capacit y Expansion Interconnect Cabling Chapter 3: Low -to -Mid Capacit y Fr ame Expansion Procedures
3 -32 68P09283A62 -2
PRELIMINARY A UG 2007
Page 91
C h a p t e r
4
What’s Next
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
■
■
68P09283A62 -2 4 -1
A UG 2007 PRELIMINARY
Page 92
Installation completion Chapter 4: What ’ s Next
Installation completion
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
A t this point the hardware installation is complete. P erform the following tasks to complete the
system installation.
• Clean up the site
• Fill out the installation completion checklist
• Record As -Built information
• P erform the A TP s
• Load the software
P erform the clean up of the site and fill out the checklist, first. Then perform the rest of the
tasks or perform them later .
■
■
Clean up the site
Clean up the site by following the instructions given in Procedure 4 -1 .
Procedure 4 -1 Cleaning the site
1
Remove protective covering
Remove any cardboard from the walls that was used to protect the walls.
Remove any antistatic plastic or cloth sheet used to cover the equipment.
2
Lighting fixtures
Remove any masking tape from the fluorescent light fixtures.
3
T ools
Place all hand and power tools in the installation tool kit or other appropriate
place. Check for any tools requiring replacement, cleaning, or adjustment.
4
Materials
Place any leftover materials in a location specified by the site manager .
5
Remove debris
T o remove the debris, perform the following:
• Remove any packing material.
• Ensure that all scrap materials are removed from any tables or stands.
• Clean/sweep the floor . Ensure all chalk -line marks are removed.
Continued
4 -2 68P09283A62 -2
PRELIMINARY A UG 2007
Page 93
R20 1X UBS Macro B T S Hardw are Installation Installation completion
Procedure 4 -1 Cleaning the site (Continued)
6
Environment
P erform the following to check the environment:
• Check whether all covers, frame doors and fan housings are in place.
• Confirm all power connections are tight.
• Organize any items (such as manuals, materials, etc.) left on site and
place them in a safe location specified by the site manager .
Fill out the installation completion checklist
A fter the site is cleaned up, fill out the installation completion checklist and make any necessary
copies. Copy this check sheet as required.
Installation completion checklist
Date Hardware Installation Completed: _________________
Site: _________________
BTS Frame Serial Number: _________________
Checklist Completed By: _________________
Checklist Reviewed By: _________________
Table 4 -1 Installation completion checklist
Status
No. Item Notes
1
Frames are bolted down.
2
DC power cabling completed.
3
Each frame has its own earth ground.
4
RX RF cables installed.
5
TX RF cables installed.
6
Span line cables installed.
7
Alarm cables installed.
8
RGPS head installed (if required).
9
RGPS cabling installed (if required).
10
All connectors (power , signal, RF ,
internal and external) are tight.
11
All cables dressed and tied.
12
Installation and site specific manuals at
site.
Continued
68P09283A62 -2 4 -3
PRELIMINARY A UG 2007
Page 94
Installation completion Chapter 4: What ’ s Next
Table 4 -1 Installation completion checklist (Continued)
Status
Record “As -Built” information
Record the site specific information on how the unit was installed and cabled.
Performing the ATPs
This manual does not cover the procedure of performing the A TP s. F or this procedure, refer to
the
1X UBS Macro BTS Optimization/A TP
No. Item Notes
13
Cable racks properly grounded.
14 Static wrist straps are present.
15
Site cleaned, swept, and trash removed.
16
Any deficiencies reported to the
appropriate people.
17
Correct polarity has been maintained
from the DC power source to the frame.
18
P ower has not been applied to any frame.
(68P09283A63) manual.
Loading the software
This manual does not cover the procedure for loading the software. Refer to the appropriate
software release manual for procedure for loading the software.
4 -4 68P09283A62 -2
PRELIMINARY A UG 2007