CPEo 400 SERIES INSTALLATION
Motorola recommends installing the external Ethernet cable in
accordance with the latest revision of the National Electrical
Code (NEC) and/or all country and local electrical codes to
provide some protection against damage caused by near-miss
lightning strikes and other electrical discharges.
INSTALLER SUPPLIED ITEMS
● Adjustable Wrench
● Two outdoor Ethernet cables
● Surge Suppressor (if required)
● Cross recessed screwdriver
● Ground cable
HARDWARE INSTALLATION PROCEDURE
Note: The Ethernet port is used for both power and data.
1. Mount the CPE unit by following and referring to figures 2 and 4. Do NOT tighten the set screws/bolts. Site configuration
determines if the CPE unit is mounted on a pole or a wall.
2. Mount the Surge Suppressor according to the manufacturer’s instructions.
3. Connect ground cable from CPE unit to ground.
4. Attach the boot on the outdoor Ethernet cable connector as shown in figures 1 and 3. Then connect that outdoor Ethernet
cable between the surge suppressor and the CPE unit.
5. Connect an outdoor Ethernet cable between the Connector Box (To Radio) and the Surge Suppressor. (Refer to Figure 1.)
6. Connect the AC power cord to the Power Adapter and then to the AC outlet/power source. (Refer to Figure 1.)
7. Plug the end of the short ethernet cable (To computer) into the Ethernet port of your computer.
8. Adjust CPE unit left/right and up/down until the interval of beeping is shortest or a constant tone. Tighten the set screws
to hold the CPE unit in position.
9. At your computer, open your browser and enter http://mywimax. (With a dot at the end) into the address field and press the
Enter key. A wizard will start up to guide you through the configuration.
10. Follow the directions in the wizard to complete the configuration.
11. Navigate the browser to Control Panel>System and disable the buzzer. The unit will stop beeping.
MOTOROLA and the Stylized M Logo are registered
in the US Patent & Trademark Office. All other
product or service names are the property of their
respective owners.
© Motorola, Inc., 2007.
68P09287A82-B
68P09287A82-B
CPE Unit
Figure 1
1
Boot Attached Here
4
5
3
Surge Suppressor
3
Ground
Connected to Pole – Assembled
Black = Motorola Supplied
Blue = Installer Supplied
7
4
2
5
Computer
AC Power Adaptor
Connected to Wall – Assembled
AC Power Cord
6
AC Outlet
6
Figure 2

Boot Assembly
Cable
Sealing Nut
Seals
Figure 3
11
2
CPEo 400 Series
10
10
Screw Nut
Motorola, Inc.
Consumer Advocacy Office
1307 East Algonquin Road
Schaumburg, IL 60196
www.motorola.com
1-800-555-1212 (United States)
1-888-555-1212 (TTY/TDD United States for
hearing impaired)
1-800-555-1212 (Canada)
6
7
Set Screw
10
12
6
12
13
4
Housing
9
13
RJ45 Plug
12
Gasket
14
1
Figure 4
14
13
11
8
7
12
13
5
15
Set Screw
10
3
13
12
14
16
PARTS LIST