Nokia T6ER1 Users manual

1X SCt4812ET Lite BTS Optimization/ATP
Software Release 2.16.0.x and CDMA LMF Build 2.16.x.x
English 08/01/2001
68P09253A60–1
800 MHz and 1.9 GHz
CDMA
Notice
While reasonable efforts have been made to assure the accuracy of this document, Motorola, Inc. assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies or omissions. Motorola, Inc. reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Motorola, Inc. does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others.
It is possible that this publication may contain references to, or information about Motorola products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Motorola intends to announce such Motorola products, programming, or services in your country.
Copyrights
This instruction manual, and the Motorola products described in this instruction manual may be, include or describe copyrighted Motorola material, such as computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Motorola certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted Motorola material contained herein or in the Motorola products described in this instruction manual may not be copied, reproduced, distributed, merged or modified in any manner without the express written permission of Motorola. Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Motorola, as arises by operation of law in the sale of a product.
Usage and Disclosure Restrictions
License Agreement
The software described in this document is the property of Motorola, Inc. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement.
Copyrighted Materials
Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Motorola, Inc.
High Risk Activities
Components, units, or third–party products used in the product described herein are NOT fault–tolerant and are NOT designed, manufactured, or intended for use as on–line control equipment in the following hazardous environments requiring fail–safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or W eapons Systems (“High Risk Activities”). Motorola and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities.
Trademarks
and Motorola are registered trademarks of Motorola, Inc.
Product and service names profiled herein are trademarks of Motorola, Inc. Other manufacturers’ products or services profiled herein may be referred to by trademarks of their respective companies.
Copyright
Copyright 2001 Motorola, Inc. All Rights Reserved
Printed on
Recyclable Paper
REV012501
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
FOA
List of Figures iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Tables vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Foreword xii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCC Requirements xv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Safety xviii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision History xx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Patent Notification xxi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1: Introduction
Optimization Manual Scope and Layout 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose of the Optimization 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When to Optimize 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents
1X SCt4812ET Lite BTS Optimization/ATP
Software Release 2.16.0.x and CDMA LMF Build 2.16.x.x
Required Test Equipment and Software 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Documents and Related Publications 1-12. . . . . . . . . . . . . . . . . . . . . . . . .
Terms and Abbreviations 1-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BTS Equipment Identification 1-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabinet Identification 1-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Assembly Location and Identification 1-18. . . . . . . . . . . . . . . . . . . . . . . . .
BTS Sector Configurations 1-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 2: Preliminary Operations
Preliminary Operations: Overview 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ethernet LAN 2-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initial Power Up 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 3: Optimization/Calibration
Optimization/Calibration – Introduction 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparing the LMF 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Span Lines – Interface and Isolation 3-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LMF to BTS Connection 3-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
08/01/2001
Using CDMA LMF 3-21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
i
Table of Contents – continued
Pinging the Processors 3-28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Download the BTS 3-31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CSM System Time – GPS & LFR/HSO Verification 3-37. . . . . . . . . . . . . . . . . . . . .
Test Equipment Setup 3-47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Set Calibration 3-55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bay Level Offset Calibration 3-64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RFDS Setup and Calibration 3-76. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarms Testing 3-85. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 4: Automated Acceptance Test Procedure (ATP)
Automated Acceptance Test Procedure – Introduction 4-1. . . . . . . . . . . . . . . . . . . .
Acceptance Tests – Test Set Up 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abbreviated (All–inclusive) Acceptance Tests 4-4. . . . . . . . . . . . . . . . . . . . . . . . . .
Individual Acceptance Tests–Introduction 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TX Spectral Purity Transmit Mask Acceptance Test 4-9. . . . . . . . . . . . . . . . . . . . .
TX Waveform Quality (Rho) Acceptance Test 4-12. . . . . . . . . . . . . . . . . . . . . . . . . .
TX Pilot Time Offset Acceptance Test 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TX Code Domain Power/Noise Floor Acceptance Test 4-15. . . . . . . . . . . . . . . . . . .
RX FER Acceptance Test 4-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Generating an ATP Report 4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 5: Leaving the Site
Updating Calibration Data Files 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prepare to Leave the Site 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 6: Basic Troubleshooting
Basic Troubleshooting Overview 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting: Installation 6-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting: Download 6-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting: Calibration 6-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Basic Troubleshooting – RF Path Fault Isolation 6-12. . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting: Transmit ATP 6-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting: Receive ATP 6-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting: CSM Checklist 6-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCCP Backplane Troubleshooting 6-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RFDS – Fault Isolation 6-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Module Front Panel LED Indicators and Connectors 6-28. . . . . . . . . . . . . . . . . . . . .
Basic Troubleshooting – Span Control Link 6-35. . . . . . . . . . . . . . . . . . . . . . . . . . .
ii
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Table of Contents – continued
Appendix A: Data Sheets
Optimization (Pre–ATP) Data Sheets A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Serial Number Check List A-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix B: FRU Optimization/ATP Test Matrix
FRU Optimization/ATP Test Matrix B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix C: BBX Gain Set Point vs. BTS Output Considerations
BBX2 Gain Set Point vs. BTS Output Considerations C-1. . . . . . . . . . . . . . . . . . .
Appendix D: CDMA Operating Frequency Information
CDMA Operating Frequency Programming Information – North American PCS Bands . D-1
Appendix E: PN Offset/I & Q Offset Register Programming Information
PN Offset Programming Information E-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix F: Test Equipment Preparation
Test Equipment Preparation F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Cable Calibration F-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix G: Download ROM Code
Downloading ROM Code with the LMF G-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix H: In–Service Calibration
Introduction H-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Delta Calibration H-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
In–Service Calibration H-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
iii
List of Figures
1X SCt4812ET Lite BTS Optimization/ATP
Software Release 2.16.0.x and CDMA LMF Build 2.16.x.x
Figure 1-1: SC4812ET Lite Logical BTS Span Cabling 1-16. . . . . . . . . . . . . . . . . .
Figure 1-2: SC4812ET Lite BTS Frame 1-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-3: Internal Assemblies and FRUs
(Cabinet doors not shown for clarity) 1-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-4: 50–Pair Punchblock 1-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-5: SCCP Shelf, IS–95A/B and 1X Devices 1-22. . . . . . . . . . . . . . . . . . . . .
Figure 1-6: RF Interface Panel, DRDCs Installed 1-23. . . . . . . . . . . . . . . . . . . . . . .
Figure 1-7: RF Interface Panel, TRDCs Installed 1-24. . . . . . . . . . . . . . . . . . . . . . .
Figure 1-8: RFDS, DRDC, and TRDC Details 1-25. . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-9: SC4812ET Lite LPA Configuration with Bandpass Filters
(Starter Frame Mapping Only) 1-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-1: Backplane DIP Switch Settings 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-2: External Ethernet LAN Connectors 2-3. . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-3: Frame Power Subassemblies, North American and
International Cabinets 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-4: ACLC Circuit Breaker Panel – North American 2-6. . . . . . . . . . . . . . .
Figure 2-5: ACLC Circuit Breaker Panel – International 2-6. . . . . . . . . . . . . . . . . .
Figure 2-6: DC PDA 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-7: ACLC Voltage Measurement Probe Points – North American 2-11. . . .
Figure 2-8: ACLC Voltage Measurement Probe Points – International 2-12. . . . . . .
Figure 2-9: Meter Alarm Panel (MAP) 2-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-10: Heat Exchanger Blower Assembly and Circuit Breakers 2-18. . . . . . .
Figure 3-1: CDMA LMF Folder Structure 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-2: BTS Folder Name Syntax Example 3-10. . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-3: CAL File Name Syntax Example 3-10. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-4: CDF Name Syntax Example 3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-5: Code Load File Name Syntax Example 3-12. . . . . . . . . . . . . . . . . . . . . .
Figure 3-6: DDS File Name Syntax Example 3-13. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-7: Disconnecting Span Lines 3-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-8: Rear and Front View of CSU Shelf 3-16. . . . . . . . . . . . . . . . . . . . . . . . .
iv
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
List of Figures – continued
Figure 3-9: 50–Pair Punchblock 3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-10: LMF Connection Detail 3-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-11: CDMA LMF Computer Common MMI Connections 3-27. . . . . . . . . .
Figure 3-12: BTS Ethernet LAN Interconnect Diagram 3-28. . . . . . . . . . . . . . . . . .
Figure 3-13: CSM MMI Terminal Connection 3-40. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-14: Cable Calibration Test Setup 3-50. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-15: TX Calibration Test Setup (CyberTest and HP 8935) 3-51. . . . . . . . . .
Figure 3-16: TX Calibration Test Setup HP 8921A and Advantest 3-52. . . . . . . . . .
Figure 3-17: Optimization/ATP Test Setup Calibration (CyberTest, HP 8935 and
Advantest) 3-53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-18: Optimization/ATP Test Setup HP 8921A 3-54. . . . . . . . . . . . . . . . . . .
Figure 3-19: Calibrating Test Equipment Setup for TX Cable Calibration
(Using Signal Generator and Spectrum Analyzer) 3-60. . . . . . . . . . . . . . . . . . . . . . .
Figure 3-20: Calibrating Test Equipment Setup for RX ATP Test
(Using Signal Generator and Spectrum Analyzer) 3-61. . . . . . . . . . . . . . . . . . . . . . .
Figure 3-21: Battery Over–Temperature Sensor 3-92. . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-22: MAP Connector J8 (Rear of MAP) 3-93. . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-1: TX Mask Verification Spectrum Analyzer Display 4-11. . . . . . . . . . . . .
Figure 4-2: Code Domain Analyzer CD Power/Noise Floor Display Examples 4-17
Figure 6-1: TX Output Fault Isolation Flowchart 6-14. . . . . . . . . . . . . . . . . . . . . . .
Figure 6-2: CSM Front Panel Indicators & Monitor Ports 6-29. . . . . . . . . . . . . . . . .
Figure 6-3: GLI2 Front Panel Operating Indicators 6-32. . . . . . . . . . . . . . . . . . . . . .
Figure 6-4: MCC24 Front Panel LEDs and LED Indicators 6-34. . . . . . . . . . . . . . .
Figure 6-5: MGLI/GLI Board MMI Connection Detail 6-36. . . . . . . . . . . . . . . . . . .
Figure D-1: North America PCS Frequency Spectrum (CDMA Allocation) D-1. . . Figure D-2: North American Cellular Telephone System Frequency Spectrum
(CDMA Allocation). D-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure F-1: HP8921A/600 Cables Connection for 10 MHz Signal
and GPIB without Rubidium Reference F-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure F-2: HP8921A Cables Connection for 10 MHz Signal and GPIB
with Rubidium Reference F-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure F-3: Cable Connections for Test Set without 10 MHz Rubidium
Reference F-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
08/01/2001
Figure F-4: Cable Connections for Test Set with 10 MHz
Rubidium Reference F-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure F-5: Power Meter Detail F-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure F-6: Gigatronics 8542C Power Meter Detail F-13. . . . . . . . . . . . . . . . . . . . .
Figure F-7: Cable Calibration Using HP8921 with PCS Interface F-17. . . . . . . . . . .
Figure F-8: Cable Calibration Using Advantest R3465 F-20. . . . . . . . . . . . . . . . . . .
Figure H-1: Delta Calibration Setup – Agilent E4432B to HP437 H-5. . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
v
List of Figures – continued
Figure H-2: Delta Calibration Setup – Agilent E4432B to Agilent E4406A H-5. . .
Figure H-3: Delta Calibration Setup – Advantest R3562 to HP437 H-8. . . . . . . . .
Figure H-4: Delta Calibration Setup – Advantest R3562 to R3267 H-8. . . . . . . . . .
Figure H-5: Delta Calibration Setup – E6380A to HP437 H-10. . . . . . . . . . . . . . . . .
Figure H-6: Delta Calibration Setup – E6380A to E6380A H-11. . . . . . . . . . . . . . . .
Figure H-7: Delta Calibration Setup – HP8921A to HP437 H-13. . . . . . . . . . . . . . .
Figure H-8: Delta Calibration Setup – HP8921A to HP8921A H-14. . . . . . . . . . . . .
Figure H-9: Delta Calibration Setup – R3561L to HP437 H-17. . . . . . . . . . . . . . . . .
Figure H-10: Delta Calibration Setup – R3561L to R3465 H-17. . . . . . . . . . . . . . . .
Figure H-11: Optimization/ATP Test Setup Using Directional Coupler –
Agilent Test Equipment H-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure H-12: Optimization/ATP Test Setup Using Directional Coupler –
Advantest R3267/R3562 Test Equipment H-21. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure H-13: Optimization/ATP Test Setup Using RFDS –
Agilent Test Equipment H-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure H-14: Optimization/ATP Test Setup Using RFDS –
Advantest R3267/R3562 Test Equipment H-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
List of Tables
1X SCt4812ET Lite BTS Optimization/ATP
Software Release 2.16.0.x and CDMA LMF Build 2.16.x.x
Table 1-1: Non–Standard Terms and Abbreviations 1-13. . . . . . . . . . . . . . . . . . . . . .
Table 1-2: SCCP Cage Module Device ID Numbers (Top Shelf) 1-16. . . . . . . . . . .
Table 1-3: SCCP Cage Module Device ID Numbers (Bottom Shelf) 1-16. . . . . . . .
Table 1-4: BTS Sector Configuration 1-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1-5: Sector Configurations 1-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-1: Initial Installation of Boards/Modules 2-1. . . . . . . . . . . . . . . . . . . . . . . .
Table 2-2: Initial Inspection and Setup 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-3: DC Power System Pre–Power Application Test 2-7. . . . . . . . . . . . . . . .
Table 2-4: AC Voltage Measurements 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-5: Applying Internal AC Power 2-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-6: DC Power Application and Tests 2-14. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-7: Battery Charge Test (Connected Batteries) 2-15. . . . . . . . . . . . . . . . . . . .
Table 2-8: Battery Discharge Test 2-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-9: Power Removal 2-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-1: CD ROM Installation 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-2: Copying CBSC CDF Files to the LMF Computer 3-5. . . . . . . . . . . . . .
Table 3-3: Create HyperTerminal Connection 3-7. . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-4: T1/E1 Span Isolation 3-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-5: Punchdown Location for 50–Pair Punch Block 3-18. . . . . . . . . . . . . . . .
Table 3-6: Connect the LMF to the BTS 3-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-7: BTS GUI Login Procedure 3-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-8: BTS CLI Login Procedure 3-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-9: BTS GUI Logout Procedure 3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-10: BTS CLI Logout Procedure 3-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-11: Establishing MMI Communication 3-26. . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-12: Pinging the Processors 3-29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-13: Verify GLI ROM Code Loads 3-32. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-14: Download and Enable MGLI and GLI Devices 3-33. . . . . . . . . . . . . . .
08/01/2001
Table 3-15: Download RAM Code and Data to Non–GLI Devices 3-34. . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
vii
List of Tables – continued
Table 3-16: Select CSM Clock Source 3-34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-17: Enable CSMs 3-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-18: Enable MCCs 3-36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-19: Test Equipment Setup (GPS & LFR/HSO Verification) 3-39. . . . . . . . .
Table 3-20: GPS Initialization/Verification 3-41. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-21: LORAN–C Initialization/Verification 3-45. . . . . . . . . . . . . . . . . . . . . . .
Table 3-22: Test Equipment Setup 3-48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-23: Selecting Test Equipment Manually in a Serial Connection Tab 3-56. .
Table 3-24: Selecting Test Equipment Using Auto-Detect 3-57. . . . . . . . . . . . . . . . .
Table 3-25: Test Equipment Calibration 3-58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-26: Cable Calibration 3-59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-27: Calibrating TX Cables Using Signal Generator and
Spectrum Analyzer 3-60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-28: Calibrating RX Cables Using a Signal Generator and
Spectrum Analyzer 3-61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-29: Setting Cable Loss Values 3-62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-30: Setting TX Coupler Loss Values 3-63. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-31: BLO BTS.cal file Array Branch Assignments 3-66. . . . . . . . . . . . . . . .
Table 3-32: SC4812ET Lite BTS.cal File Array (Per Sector) 3-67. . . . . . . . . . . . . .
Table 3-33: Set Up Test Equipment (RF Path Calibration) 3-68. . . . . . . . . . . . . . . .
Table 3-34: All Cal/Audit Path Calibration 3-71. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-35: TX Calibration Test 3-71. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-36: Download BLO 3-73. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-37: TX Path Audit 3-74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-38: Create CAL File 3-75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-39: RFDS Parameter Settings 3-77. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-40: Definition of Parameters 3-78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-41: Valid NAM Field Ranges 3-79. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-42: Set Antenna Map Data 3-80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-43: Set RFDS Configuration Data 3-81. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-44: RFDS TSIC Calibration Channel Frequencies 3-82. . . . . . . . . . . . . . . .
Table 3-45: RFDS Calibration 3-83. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii
Table 3-46: Program NAM Procedure 3-84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-47: Alarm Testing Preparation 3-86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-48: Heat Exchanger Alarm 3-86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-49: ACLC and Power Entry Door Alarm 3-86. . . . . . . . . . . . . . . . . . . . . . .
Table 3-50: AC Fail Alarm 3-87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
List of Tables – continued
Table 3-51: Minor Alarm 3-87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-52: Single Rectifier Fail or Minor Alarm, Single–Carrier System 3-88. . . .
Table 3-53: Multiple Rectifier Failure or Major Alarm, Single–Carrier System 3-88
Table 3-54: Single Rectifier Fail or Minor Alarm, Two–Carrier System 3-89. . . . . .
Table 3-55: Multiple Rectifier Failure or Major Alarm, Two–Carrier System 3-90.
Table 3-56: Battery Over–Temperature Alarm 3-90. . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-57: Rectifier Over–Temperature Alarm 3-93. . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-1: Set Up Test Equipment – TX Output Verify/Control Tests 4-3. . . . . . . .
Table 4-2: All TX/RX ATP Test Procedure 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-3: All TX ATP Test Procedure 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-4: All RX ATP Test Procedure 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-5: Test Spectral Purity Transmit Mask 4-10. . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-6: Test Waveform Quality (Rho) 4-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-7: Test Pilot Time Offset 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-8: Test Code Domain Power/Noise Floor 4-16. . . . . . . . . . . . . . . . . . . . . . .
Table 4-9: Test FER 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-10: Generating an ATP Report 4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-1: Copying CAL Files to a Diskette 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-2: Copying CAL Files from Diskette to the CBSC 5-1. . . . . . . . . . . . . . . .
Table 5-3: Remove External Test Equipment 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-4: Reset BTS Devices and Remote Site Initialization 5-3. . . . . . . . . . . . . .
Table 5-5: Bring Modules into Service 5-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-6: Remove LMF 5-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-7: Connect T1 or E1 Spans 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-8: Check Before Leaving the Site 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-1: Login Failure Troubleshooting Procedures 6-2. . . . . . . . . . . . . . . . . . . .
Table 6-2: Force Ethernet LAN A to Active State as Primary LAN 6-2. . . . . . . . .
Table 6-3: GLI IP Address Setting 6-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-4: Troubleshooting a Power Meter Communication Failure 6-5. . . . . . . . .
Table 6-5: Troubleshooting a Communications Analyzer
Communication Failure 6-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
08/01/2001
Table 6-6: Troubleshooting Code Download Failure 6-7. . . . . . . . . . . . . . . . . . . . .
Table 6-7: Troubleshooting Data Download Failure 6-7. . . . . . . . . . . . . . . . . . . . .
Table 6-8: Troubleshooting Device Enable (INS) Failure 6-8. . . . . . . . . . . . . . . . .
Table 6-9: LPA Errors 6-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-10: Troubleshooting BLO Calibration Failure 6-10. . . . . . . . . . . . . . . . . . .
Table 6-11: Troubleshooting Calibration Audit Failure 6-11. . . . . . . . . . . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
ix
List of Tables – continued
Table 6-12: Troubleshooting TX Mask Measurement Failure 6-15. . . . . . . . . . . . . .
Table 6-13: Troubleshooting Rho and Pilot Time Offset Measurement Failure 6-15 Table 6-14: Troubleshooting Code Domain Power and Noise Floor
Measurement Failure 6-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-15: Troubleshooting Carrier Measurement Failure 6-16. . . . . . . . . . . . . . . .
Table 6-16: Troubleshooting Multi-FER Failure 6-17. . . . . . . . . . . . . . . . . . . . . . . .
Table 6-17: No GLI2 Control via LMF (all GLI2s) 6-21. . . . . . . . . . . . . . . . . . . . . .
Table 6-18: No GLI2 Control through Span Line Connection (Both GLI2s) 6-22. .
Table 6-19: MGLI2 Control Good – No Control over Co–located GLI2 6-22. . . . .
Table 6-20: MGLI2 Control Good – No Control over AMR 6-22. . . . . . . . . . . . . . .
Table 6-21: MGLI2 Control Good – No Control over Co–located BBX2s 6-23. . . .
Table 6-22: BBX2 Control Good – No (or Missing) Span Line Traffic 6-23. . . . . . .
Table 6-23: No MCC24/MCC8E Channel Elements 6-23. . . . . . . . . . . . . . . . . . . . .
Table 6-24: No DC Input Voltage to Power Supply Module 6-24. . . . . . . . . . . . . . .
Table 6-25: No DC Input Voltage to any SCCP Shelf Module 6-25. . . . . . . . . . . . .
Table 6-26: TX and RX Signal Routing Problems 6-25. . . . . . . . . . . . . . . . . . . . . . .
Table 6-27: RFDS Fault Isolation – All tests fail 6-26. . . . . . . . . . . . . . . . . . . . . . . .
Table 6-28: RFDS Fault Isolation – All tests fail on single antenna path 6-26. . . . .
Table 6-29: Troubleshoot Control Link Failure 6-35. . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-30: Set BTS Span Parameter Configuration 6-37. . . . . . . . . . . . . . . . . . . . .
Table A-1: Verification of Test Equipment Used A-1. . . . . . . . . . . . . . . . . . . . . . . .
Table A-2: Site Checklist A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-3: Preliminary Operations A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-4: GPS Receiver Operation A-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-5: LFR Receiver Operation A-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-6: LPA IM Reduction A-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-7: TX BLO Calibration (3–Sector: 1–Carrier and 2–Carrier
Non–adjacent Channels) A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-8: TX Bay Level Offset Calibration (3–Sector: 2–Carrier
Adjacent Channels) A-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-9: TX Antenna VSWR A-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-10: RX Antenna VSWR A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-11: CDI Alarm Input Verification A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-1: When RF Optimization Is required on the BTS B-1. . . . . . . . . . . . . . . .
Table B-2: When to Optimize Inter–frame Cabling B-1. . . . . . . . . . . . . . . . . . . . . .
Table B-3: SC 4812ET Lite BTS Optimization and ATP Test Matrix B-3. . . . . . . .
Table C-1: BBX2 Gain Set Point vs. Actual BTS Output (in dBm) C-1. . . . . . . . .
Table D-1: 1900 MHz TX and RX Frequency vs. Channel D-2. . . . . . . . . . . . . . . .
x
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
List of Tables – continued
Table D-2: 800 MHz TX and RX Frequency vs. Channel D-4. . . . . . . . . . . . . . . . .
Table E-1: PnMaskI and PnMaskQ Values for PilotPn E-3. . . . . . . . . . . . . . . . . . .
Table F-1: HP8921A/600 Communications Test Set Rear Panel
Connections Without Rubidium Reference F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-2: HP8921A/600 Communications Test Set Rear Panel
Connections With Rubidium Reference F-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-3: System Connectivity F-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-4: Setting HP8921A GPIB Address F-6. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-5: Pretest Setup for HP8921A F-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-6: Pretest Setup for HP8935 F-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-7: Advantest R3465 GPIB Address and Clock Setup F-9. . . . . . . . . . . . . .
Table F-8: Pretest Setup for Advantest R346 F-9. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-9: Power Meter Calibration Procedure F-10. . . . . . . . . . . . . . . . . . . . . . . . .
Table F-10: Calibrate Gigatronics 8542 Power Meter F-12. . . . . . . . . . . . . . . . . . . .
Table F-11: Calibrating Test Cable Setup (using the HP PCS Interface) F-14. . . . . .
Table F-12: Procedure for Calibrating Test Cable Setup Using
Advantest R3465 F-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table G-1: Download ROM and RAM Code to Devices G-2. . . . . . . . . . . . . . . . . .
Table H-1: Agilent E4406A Power Delta Calibration Procedure H-3. . . . . . . . . . . .
Table H-2: Advantest R3267 Power Delta Calibration Procedure H-6. . . . . . . . . . .
Table H-3: Agilent E6380A Power Delta Calibration Procedure H-9. . . . . . . . . . . .
Table H-4: HP8921A Power Delta Calibration Procedure H-12. . . . . . . . . . . . . . . . .
Table H-5: Advantest Power Delta Calibration Procedure H-15. . . . . . . . . . . . . . . . .
Table H-6: In–Service Calibration H-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
xi
Foreword
Scope of manual
This manual is intended for use by cellular telephone system craftspersons in the day-to-day operation of Motorola cellular system equipment and ancillary devices. It is assumed that the user of this information has a general understanding of telephony, as used in the operation of the Public Switched Telephone Network (PSTN), and is familiar with these concepts as they are applied in the cellular mobile/portable radiotelephone environment. The user, however, is not expected to have any detailed technical knowledge of the internal operation of the equipment.
This document covers only the steps required to verify the functionality of the RF Base Transceiver Subsystem (BTS) equipment prior to system level testing, and is intended to supplement site specific application instructions. It also should be used in conjunction with existing product manuals. Additional steps may be required.
This manual is not intended to replace the system and equipment training offered by Motorola, although it can be used to supplement or enhance the knowledge gained through such training.
Text conventions
The following special paragraphs are used in this manual to point out information that must be read. This information may be set-off from the surrounding text, but is always preceded by a bold title in capital letters. The four categories of these special paragraphs are:
NOTE
Presents additional, helpful, non-critical information that you can use.
IMPORTANT
*
Presents information to help you avoid an undesirable situation or provides additional information to help you understand a topic or concept.
CAUTION
Presents information to identify a situation in which equipment damage could occur, thus avoiding damage to equipment.
xii
WARNING
Presents information to warn you of a potentially hazardous situation in which there is a possibility of personal injury.
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Foreword – continued
Changes to manual
The following special paragraphs are used in tables in the manual to point out information that must be read.
NOTE
Presents additional, helpful non-critical information that you can use.
* IMPORTANT
Presents information to help you avoid an undesirable situation or provide additional information to help you understand a topic or concept.
! CAUTION
Presents information to identify a situation where equipment damage could occur and help you avoid damaging your equipment.
n W ARNING
Presents information to warn you of a potentially hazardous situation where there is a possibility of personal injury (serious or otherwise).
Receiving updates
Changes that occur after the printing date are incorporated into your manual by Cellular Manual Revisions (CMRs). The information in this manual is updated, as required, by a CMR when new options and procedures become available for general use or when engineering changes occur. The cover sheet(s) that accompany each CMR should be retained for future reference. Refer to the Revision History page for a list of all applicable CMRs contained in this manual.
Technical Education & Documentation (TED) maintains a customer database that reflects the type and number of manuals ordered or shipped since the original delivery of your Motorola equipment. Also identified in this database is a “key” individual (such as Documentation Coordinator or Facility Librarian) designated to receive manual updates from TED as they are released.
To ensure that your facility receives updates to your manuals, it is important that the information in our database is correct and up-to-date. Therefore, if you have corrections or wish to make changes to the information in our database (i.e., to assign a new “key” individual), please contact Technical Education & Documentation at:
MOTOROLA, INC. Technical Education & Documentation 1 Nelson C. White Parkway Mundelein, Illinois 60060 U.S.A.
08/01/2001
Phone:
Within U.S.A. and Canada 800-872-8225. . . . .
Outside of U.S.A. and Canada +1-847-435–5700. .
FAX: +1-847-435–5541. . . . . . . . . . . . . . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
xiii
Foreword – continued
Reporting manual errors
In the event that you locate an error or identify a deficiency in your manual, please take time to write to us at the address above. Be sure to include your name and address, the complete manual title and part number (located on the manual spine, cover, or title page), the page number (found at the bottom of each page) where the error is located, and any comments you may have regarding what you have found. We appreciate any comments from the users of our manuals.
xiv
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
FCC Requirements
Content
FCC Part 15 Requirements
This section presents Federal Communications Commission (FCC) Rules Parts 15 and 68 requirements and compliance information for the SCt4812T/ET/ET Lite series RF Base Transceiver Stations (BTS).
Part 15.19a(3) – INFORMATION TO USER
NOTE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Part 15.21 – INFORMATION TO USER
CAUTION
Changes or modifications not expressly approved by Motorola could void your authority to operate the equipment.
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
xv
FCC Requirements continued
15.105(b) – INFORMATION TO USER NOTE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and re-
ceiver.
– Connect the equipment into an outlet on a circuit differ-
ent from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician
for help.
FCC Part 68 Requirements
This equipment complies with Part 68 of the Federal Communications Commission (FCC) Rules. A label inside the cabinet frame easily visible with the door open in the upper portion of the cabinet contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment. If requested, this information must be provided to the telephone company.
The REN is useful to determine the quantity of the devices which may connect to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to incoming calls. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area.
If the dial–in site access modem causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify you of the discontinuance as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of your dial–in
xvi
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
FCC Requirements – continued
site access modem. If this happens, the telephone company will provide advance notice so that you can modify your equipment as required to maintain uninterrupted service.
If you experience trouble with the dial–in site access modem, please contact:
for repair and/or warranty information. If the trouble is causing harm to the telephone network, the telephone company may request you to disconnect the equipment from the network until the problem is solved. You should not attempt to repair this equipment yourself. This equipment contains no customer or user–serviceable parts.
Changes or modifications not expressly approved by Motorola could void your authority to operate this equipment.
Global Customer Network Resolution Center (CNRC) 1501 W. Shure Drive, 3436N Arlington Heights, Illinois 60004 Phone Number: (847) 632–5390
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
xvii
General Safety
Remember! . . . Safety depends on you!!
Ground the instrument
The following general safety precautions must be observed during all phases of operation, service, and repair of the equipment described in this manual. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the equipment. Motorola, Inc. assumes no liability for the customers failure to comply with these requirements. The safety precautions listed below represent warnings of certain dangers of which we are aware. You, as the user of this product, should follow these warnings and all other safety precautions necessary for the safe operation of the equipment in your operating environment.
To minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical ground. If the equipment is supplied with a three-conductor ac power cable, the power cable must be either plugged into an approved three-contact electrical outlet or used with a three-contact to two-contact adapter. The three-contact to two-contact adapter must have the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable must meet International Electrotechnical Commission (IEC) safety standards.
Do not operate in an explosive atmosphere
Keep away from live circuits
Do not service or adjust alone
Do not operate the equipment in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment constitutes a definite safety hazard.
Operating personnel must:
S not remove equipment covers. Only Factory Authorized Service
Personnel or other qualified maintenance personnel may remove equipment covers for internal subassembly, or component replacement, or any internal adjustment.
S not replace components with power cable connected. Under certain
conditions, dangerous voltages may exist even with the power cable removed.
S always disconnect power and discharge circuits before touching them.
Do not attempt internal service or adjustment, unless another person, capable of rendering first aid and resuscitation, is present.
xviii
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
General Safety – continued
Use caution when exposing or handling the CRT
Do not substitute parts or modify equipment
Dangerous procedure warnings
Breakage of the Cathode–Ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To prevent CRT implosion, avoid rough handling or jarring of the equipment. The CRT should be handled only by qualified maintenance personnel, using approved safety mask and gloves.
Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification of equipment. Contact Motorola Warranty and Repair for service and repair to ensure that safety features are maintained.
Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. You should also employ all other safety precautions that you deem necessary for the operation of the equipment in your operating environment.
WARNING
Dangerous voltages, capable of causing death, are present in this equipment. Use extreme caution when handling, testing, and adjusting.
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
xix
Revision History
Manual Number
Manual Title
Version Information
68P09253A60
1X SCt4812ET Lite BTS Optimization/ATP Software Release 2.16.0.x and CDMA LMF Build 2.16.x.x
The following table lists the manual version, date of version, and remarks on the version.
Version
Level
1 08/2/2001 Preliminary version of manual for R2.16.0 1X BTS
Date of
Issue
Remarks
xx
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Patent Notification
Patent numbers
4128740 4661790 4860281 5036515 5119508 5204876 5247544 5301353 4193036 4667172 4866710 5036531 5121414 5204977 5251233 5301365 4237534 4672657 4870686 5038399 5123014 5207491 5255292 5303240 4268722 4694484 4872204 5040127 5127040 5210771 5257398 5303289 4282493 4696027 4873683 5041699 5127100 5212815 5259021 5303407 4301531 4704734 4876740 5047762 5128959 5212826 5261119 5305468 4302845 4709344 4881082 5048116 5130663 5214675 5263047 5307022 4312074 4710724 4885553 5055800 5133010 5214774 5263052 5307512 4350958 4726050 4887050 5055802 5140286 5216692 5263055 5309443 4354248 4729531 4887265 5058136 5142551 5218630 5265122 5309503 4367443 4737978 4893327 5060227 5142696 5220936 5268933 5311143 4369516 4742514 4896361 5060265 5144644 5222078 5271042 5311176 4369520 4751725 4910470 5065408 5146609 5222123 5274844 5311571 4369522 4754450 4914696 5067139 5146610 5222141 5274845 5313489 4375622 4764737 4918732 5068625 5152007 5222251 5276685 5319712 4485486 4764849 4941203 5070310 5155448 5224121 5276707 5321705 4491972 4775998 4945570 5073909 5157693 5224122 5276906 5321737 4517561 4775999 4956854 5073971 5159283 5226058 5276907 5323391 4519096 4797947 4970475 5075651 5159593 5228029 5276911 5325394 4549311 4799253 4972355 5077532 5159608 5230007 5276913 5327575 4550426 4802236 4972432 5077741 5170392 5233633 5276915 5329547 4564821 4803726 4979207 5077757 5170485 5235612 5278871 5329635 4573017 4811377 4984219 5081641 5170492 5235614 5280630 5339337 4581602 4811380 4984290 5083304 5182749 5239294 5285447 D337328 4590473 4811404 4992753 5090051 5184349 5239675 5287544 D342249 4591851 4817157 4998289 5093632 5185739 5241545 5287556 D342250 4616314 4827507 5020076 5095500 5187809 5241548 5289505 D347004 4636791 4829543 5021801 5105435 5187811 5241650 5291475 D349689 4644351 4833701 5022054 5111454 5193102 5241688 5295136 RE31814 4646038 4837800 5023900 5111478 5195108 5243653 5297161 4649543 4843633 5028885 5113400 5200655 5245611 5299228 4654655 4847869 5030793 5117441 5203010 5245629 5301056 4654867 4852090 5031193 5119040 5204874 5245634 5301188
This product is manufactured and/or operated under one or more of the following patents and other patents pending:
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
xxi
Patent Notification – continued
Notes
xxii
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Chapter 1: Introduction
Table of Contents
Optimization Manual Scope and Layout 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Scope and Layout 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assumptions and Prerequisites 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Document Composition 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose of the Optimization 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Why Optimize? 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What Is Optimization? 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What Happens During Optimization 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . .
1
When to Optimize 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
New Installations 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Expansion 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Periodic Optimization 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repaired Sites 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Test Equipment and Software 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Policy 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Equipment Calibration 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Cable Calibration 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Warm–up 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Test Equipment and Software 1-6. . . . . . . . . . . . . . . . . . . . . . . .
Optional Equipment 1-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Documents and Related Publications 1-12. . . . . . . . . . . . . . . . . . . . . . . . .
Required Documents 1-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Related Publications 1-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terms and Abbreviations 1-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard and Non–standard Terms and Abbreviations 1-13. . . . . . . . . . . . .
BTS Equipment Identification 1-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Overview 1-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logical BTS Numbering 1-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
08/01/2001
Cabinet Identification 1-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Major Components 1-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Assembly Location and Identification 1-18. . . . . . . . . . . . . . . . . . . . . . . . .
Internal Assemblies and FRUs 1-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCCP Cage Configuration and the 1X Devices 1-26. . . . . . . . . . . . . . . . . .
BTS Sector Configurations 1-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sector Configuration 1-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1X SCt4812ET Lite BTS Optimization/ATP
1
Table of Contents – continued
Notes
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Optimization Manual Scope and Layout
Manual Scope and Layout
This document provides information pertaining to the optimization and audit tests of the Motorola SC4812ET Lite RF Base Transceiver Station (BTS) equipment frame and its associated internal and external interfaces. The following subjects are addressed: preliminary background information; optimization, and alarm/redundancy tests; Acceptance Test Procedures (ATP) to verify site operation and regulation compliance; site turnover; troubleshooting.
Most applications use the same test procedure for all equipment variations. However, decision break points are provided throughout the procedure when equipment–specific tests are required. For example, when tests using external test equipment are performed instead of those using the RFDS, additional test procedures and illustrations are provided to cover both applications.
This optimization procedure consists of a group of task-oriented tests. Each major test category (Audit, Initial power–up, Calibration tests, etc.) is described in chapters which are broken down into multi-page “maps.”
1
Assumptions and Prerequisites
Each map typically consists of pages containing all the information necessary to perform the test (including all required input levels, output levels, CDMA Local Maintenance Facility (CDMA LMF) commands, and test points required). Also described are some of the main concepts you must understand in the test process. Whenever possible, graphics, flowcharts, or other examples complement the information/steps.
This document assumes that the BTS frames and cabling have been installed per the Frame Mounting Guide Analog/CDMA/TDMA; 68P09226A18, which covers the physical “bolt down of all SC series equipment frames, and the SC4812ET Lite Installation; 68P09253A36, which covers BTS–specific cabling configurations.
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
1-1
1
Optimization Manual Scope and Layout – continued
Document Composition
This document covers the following major areas:
S Introduction, consisting of preliminary background information (such
as component and subassembly locations and frame layouts) to be considered by the Cellular Field Engineer (CFE) before performing optimization or tests.
S Preliminary Operations, consisting of jumper configuration of BTS
sub–assemblies, pre–power–up tests, initial application of power to the BTS equipment frames, and initial power–up tests.
S Optimization/Calibration, consisting of procedures for downloading
all BTS processor boards, test equipment set–up, RF path verification, BLO calibration and calibration audit, and Radio Frequency Diagnostic System (RFDS) calibration.
S Acceptance Test Procedures (ATP), consisting of automated ATP tests,
executed by the CDMA LMF, and used to verify all major TX and RX performance characteristics on all BTS equipment. This chapter also covers generating an ATP report.
S Prepare to Leave the Site, discussing site turnover after ATP is
completed.
S Basic Troubleshooting, consisting of procedures to perform when an
ATP fails, as well as when incorrect results are obtained during logon, test equipment operation, calibration, and GPS operation.
S Appendices that contain pertinent PN offset, frequency programming,
and output power data tables, along with additional data sheets that are filled out manually by the CFE at the site.
1-2
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Purpose of the Optimization
Why Optimize?
What Is Optimization?
What Happens During Optimization
1
Proper optimization and calibration ensures that:
S Accurate downlink RF power levels are transmitted from the site. S Accurate uplink signal strength determinations are made by the site.
Optimization compensates for the site-specific cabling and normal equipment variations. Site optimization guarantees that the combined losses of the new cables and the gain/loss characteristics and built-in tolerances of each BTS frame do not accumulate and cause improper site operation.
Optimization identifies the accumulated loss (or gain) for each receive and transmit path at the BTS site, and stores these values in a database.
S A receive path (RX) starts at the Duplexer Directional Coupler
(DRDC) or Transmit & Receive Dual Directional Coupler (TRDC) antenna feedline port and travels through the DRDC/TRDC, the Multi–coupler Preselector Card (MPC) and additional splitter circuitry, ending at a Broad Band Transceiver (BBX) backplane slot in the Small CDMA Channel Processor (SCCP) shelf.
S A transmit path (TX) starts at the SCCP shelf BBX backplane slot, is
routed to the Linear Power Amplifier (LPA) Trunking Module, through the LPAs, back through the LPA Trunking Module, through the bandpass filter or 2–cavity combiner, and ends at the DRDC/TRDC antenna feedline port.
Six of the seven BBX2 boards in each SCCP shelf are optimized to specific RX and TX antenna ports. The seventh BBX2 board acts in a redundant capacity for BBX2 boards 1 through 6, and is optimized to all antenna ports. A single value is generated for each complete path, thereby eliminating the accumulation of error that would occur from individually measuring and summing the gain and loss of each element in the path.
BTS equipment factors in these values internally, leaving only site–specific antenna feed line loss and antenna gain characteristics to be factored in by the CFE when determining site Effective Radiated Power (ERP) output power requirements.
08/01/2001
1X SCt4812ET Lite BTS Optimization/ATP
1-3
1
When to Optimize
New Installations
After the initial site installation, the BTS must be prepared for operation. This preparation includes verifying hardware installation, initial power–up, downloading of operating code, verifying GPS operation and verifying transmit and receive paths.
Next, the optimization is performed. Optimization includes performance verification and calibration of all transmit and receive RF paths, and download of accumulated calibration data.
A calibration audit of all RF transmit paths may be performed any time after optimization to verify BTS calibration.
After optimization, a series of manual pre–Acceptance Test Procedure (ATP) verification tests are performed to verify alarm/redundancy performance.
After manual pre–ATP verification tests, a series of ATPs are performed to verify BTS performance. An ATP is also required before the site can be placed in service.
Site Expansion
Periodic Optimization
Repaired Sites
Optimization is also required after expansion of a site with additional, interconnected BTS frames.
Periodic optimization of a site may also be required, depending on the requirements of the overall system.
IMPORTANT
*
Refer to Appendix B for a detailed FRU Optimization/ATP Test Matrix outlining the minimum tests that must be performed any time a BTS subassembly or RF cable associated with it is replaced.
1-4
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
Loading...