Nokia T6EK1 User Manual

Technical Information
SOFTWARE RELEASE 2.16.5.X
1.9 GHZ CDMA2000 1X
DRAFT
ENGLISH JUN 2004 68P09262A08–1
Notice
While reasonable efforts have been made to assure the accuracy of this document, Motorola, Inc. assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies or omissions. Motorola, Inc. reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Motorola, Inc. does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others.
It is possible that this publication may contain references to, or information about Motorola products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Motorola intends to announce such Motorola products, programming, or services in your country.
Copyrights
This instruction manual, and the Motorola products described in this instruction manual may be, include or describe copyrighted Motorola material, such as computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Motorola and its licensors certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Motorola and its licensors contained herein or in the Motorola products described in this instruction manual may not be copied, reproduced, distributed, merged or modified in any manner without the express written permission of Motorola. Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Motorola, as arises by operation of law in the sale of a product.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Usage and Disclosure Restrictions
License Agreement
The software described in this document is the property of Motorola, Inc and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement.
Copyrighted Materials
Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Motorola, Inc.
High Risk Activities
Components, units, or third–party products used in the product described herein are NOT fault–tolerant and are NOT designed, manufactured, or intended for use as on–line control equipment in the following hazardous environments requiring fail–safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (“High Risk Activities”). Motorola and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities.
Trademarks
MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners.
© Copyright 2003, 2004 Motorola, Inc. Javat Technology and/or J2MEt: Java and all other Java–based marks are trademarks or registered trademarks of Sun
Microsystems, Inc. in the U.S. and other countries.
R
: UNIX is a registered trademark of The Open Group in the United States and other countries.
UNIX
DRAFT
REV091302
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
List of Figures vi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Tables xii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Foreword xxi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCC Requirements xxiii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Safety xxvi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision History xxviii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1: Introduction
Introduction 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Documents 1-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CDMA 1.9 GHz Operating Frequency Programming Information 1-8 . . . . . . . . . .
Installation Tools and Materials 1-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents
Software Release 2.16.5.X
ATP Tools and Materials 1-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BTS Equipment Identification 1-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Enclosure Equipment Identification 1-29 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation and ATP Order 1-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 2: Site Preparation
Site Preparation Overview 2-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Inspections 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prepare Site for the Arrival of the Equipment 2-5 . . . . . . . . . . . . . . . . . . . . . . . . . .
Unpacking the Equipment 2-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions and Clearances 2-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 3: BTS Cables
Cable Description 3-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power, Earth Ground, and Battery Cabling 3-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Antenna Cabling 3-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Span Line Cabling 3-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remote GPS Head and Cabling 3-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local GPS (RF–GPS) Antenna Cabling 3-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU i
DRAFT
Table of Contents – continued
Chapter 4: BTS and Cabling Installation
Installation Overview 4-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connector Locations 4-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Attaching BTS to Mounting Rack 4-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact Combined Linear Power Amplifier Installation 4-10 . . . . . . . . . . . . . . . . .
Thermal Management Enclosure Installation 4-21 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact BTS and HMS Installation 4-28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Distribution Enclosure Installation 4-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Earth Ground Cabling 4-47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BTS DC Power Cabling 4-54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC / DC Power Cabling Installation 4-57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Antenna Cabling 4-59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Span Line, RGPS, and RF GPS Cabling 4-64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customer Input / Output Cables 4-76 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Cleanup 4-78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Completion Checklist 4-79 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 5: Power Installation
Frame Configuration DIP Switch 5-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pre–Power Up Test (Indoor) 5-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Power Input (Outdoor Configuration) 5-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery Backup DC Power Input (Outdoor Configuration) 5-9 . . . . . . . . . . . . . . . .
Initial Power–Up Test 5-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remove Power 5-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 6: Optimization and Calibration
Preliminary Operations: Overview 6-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preliminary Operations: Overview 6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ethernet LAN 6-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to Optimization and Calibration 6-4 . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparing the LMF 6-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Span Lines – Interface and Isolation 6-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LMF to BTS Connection 6-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the LMF 6-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pinging the Processors 6-33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pinging the Processors 6-34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Download the BTS 6-36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CSA System Time – GPS & HSO/MSO Verification 6-43 . . . . . . . . . . . . . . . . . . . .
ii 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
Table of Contents – continued
Test Equipment Setup 6-51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Set Calibration 6-65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bay Level Offset Calibration 6-76 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 7: Automated Acceptance Test Procedure (ATP)
Automated Acceptance Test Procedure – Introduction 7-1 . . . . . . . . . . . . . . . . . . . .
Acceptance Tests – Test Set Up 7-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abbreviated (All–inclusive) Acceptance Tests 7-5 . . . . . . . . . . . . . . . . . . . . . . . . . .
Individual Acceptance Tests–Introduction 7-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TX Spectral Purity Transmit Mask Acceptance Test 7-11 . . . . . . . . . . . . . . . . . . . . .
TX Waveform Quality (Rho) Acceptance Test 7-14 . . . . . . . . . . . . . . . . . . . . . . . . . .
TX Pilot Time Offset Acceptance Test 7-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TX Code Domain Power/Noise Floor Acceptance Test 7-18 . . . . . . . . . . . . . . . . . . .
RX FER Acceptance Test 7-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Generating an ATP Report 7-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 8: Leave the Site
Updating Calibration Data Files 8-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prepare to Leave the Site 8-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 9: Field Replaceable Unit
Introduction 9-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Module 9-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High and Medium Stability Oscillator Module 9-7 . . . . . . . . . . . . . . . . . . . . . . . . .
Global Positioning System (GPS) Receivers 9-11 . . . . . . . . . . . . . . . . . . . . . . . . . . .
RF–GPS Module 9-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply Module (PSM) 9-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clock Synchronization Alarms Card 9-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Group Line Interface Card 9-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multi–Channel CDMA Card 9-28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Broadband Transceiver Card 9-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact BTS Multi–Coupler Preselector Card 9-36 . . . . . . . . . . . . . . . . . . . . . . . . .
MCC Data Only (MCC–DO) Card 9-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact BTS Input and Output Board 9-45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SDCX Module 9-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RF Filter Tray 9-55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact Combined Linear Power Amplifier 9-67 . . . . . . . . . . . . . . . . . . . . . . . . . . .
TME Power Distribution Assembly 9-70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU iii
DRAFT
Table of Contents – continued
Heat Management System 9-74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Management Enclosure 9-82 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Distribution Enclosure 9-85 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Master Item Number Failure List 9-86 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 10: Reference Procedures Performed At OMC–R
Reference Procedures Performed At OMC–R 10-1 . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessing OMC–R CLI Window 10-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit BTS Shut Down Procedures 10-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit BTS Start–Up Procedures 10-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Packet BTS Shut Down Procedures 10-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Packet BTS Start–Up Procedures 10-53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 11: Basic Troubleshooting
Basic Troubleshooting 11-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix A: MCC–Data Only
MCC–DO Tests A-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix B: Test Equipment Preparation
Test Equipment Preparation B-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying and Setting GPIB Addresses B-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Equipment Connection, Testing, and Control B-17 . . . . . . . . . . . . . . . . . . . . . . .
Equipment Calibration B-28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Cable Calibration B-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix C: Download ROM Code
Downloading ROM Code C-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix D: MMI Cable Fabrication
MMI Cable Fabrication D-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix E: Multiple BTS Configurations
Compact BTS Expansion Configuration (Indoor) E-1 . . . . . . . . . . . . . . . . . . . . . . .
Multiple Compact BTS Configuration (Outdoor) E-22 . . . . . . . . . . . . . . . . . . . . . . .
Appendix F: Logical BTS Configuration
Logical BTS LAN Configuration for Compact BTS (Indoor) F-1 . . . . . . . . . . . . . .
Appendix G: Integrated BTS Router Preliminary Operations
Integrated BTS Router Preliminary Operations – Introduction G-1 . . . . . . . . . . . . .
Verify GLI3 Software Version and Span Parameter Settings G-2 . . . . . . . . . . . . . . .
iv 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
Table of Contents – continued
Change GLI3 Span Parameter Settings G-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix H: Integrated BTS Router Installation
Integrated BTS Router Installation – Introduction H-1 . . . . . . . . . . . . . . . . . . . . . . .
New Packet BTS Installation with IBR H-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BTS Span Connections for IBR H-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BTS Span Connections for IBR – One Span H-5 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix I: Packet Backhaul Configuration
Packet Backhaul BTS I-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix J: Highway Cell Configuration
BTS for Highway Cell Configuration J-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU v
DRAFT
List of Figures
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
Software Release 2.16.5.X
FCC Label and Location xxv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-1: Mounted BTS and Rack 1-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-2: North America PCS Frequency Spectrum (CDMA Allocation) 1-8 . . .
Figure 1-3: RS232–IEEE488 Converter Serial Cable Configuration 1-16 . . . . . . . . .
Figure 1-4: Front View of Compact BTS 1-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-5: Rear View of Compact BTS 1-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-6: CCP2 Shelf Layout 1-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-7: CBIO Board 1-27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-8: +27VDC RF Connectors, Circuit Breaker, DC Power Terminal
Strip, and Ground Studs 1-28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-9: Thermal Managment Enclosure and Heat Manaagement
System 1-29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-10: Power Distribution Assembly 1-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1-11: Power Distribution Enclosure and Heat Exchanger 1-31 . . . . . . . . . . . .
Figure 1-12: Compact Combined Linear Power Amplifier 1-31 . . . . . . . . . . . . . . . .
Figure 2-1: Securing Lights with Tape 2-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-2: Wood Shipping Container 2-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-3: Cardboard Shipping Container 2-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-4: Overall Dimensions of BTS 2-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-5: cCLPA Dimensions and Functional Clearances 2-17 . . . . . . . . . . . . . . .
Figure 2-6: Indoor Functional Clearances for BTS 2-18 . . . . . . . . . . . . . . . . . . . . . .
Figure 2-7: Indoor Functional Clearances for BTS Side–By–Side
Configuration 2-19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-8: TME 2-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-9: Overall Dimensions of the Thermal Management Enclosure 2-21 . . . . .
Figure 2-10: Functional Clearances for TME 2-22 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-11: PDE 2-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-12: PDE Overall Dimensions 2-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-13: Functional Clearances for PDE 2-25 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2-14: Mulitple Pole Installation and Functional Clearances for
Enclosures and PA 2-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Figures – continued
Figure 2-15: Multiple Wall Installation and Functional Clearances for
TME and HMS, PDE, and cCLPA 2-27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3-1: Antenna Cabling Details 3-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-1: Rear View of BTS 4-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-2: Detail of Antenna Connectors and DC Power (Rear of BTS) 4-4 . . . . .
Figure 4-3: Attaching Mounting Plate to Rack 4-6 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-4: Attaching Mounting Bracket to BTS 4-7 . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-5: Attaching BTS to Mounting Plate 4-8 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-6: BTS Rear Attachment 4-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-7: Bottom View of cCLPA 4-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-8: cCLPA Mounting to Rack 4-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-9: cCLPA Grounding 4-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-10: DC Power Connection to cCLPA 4-15 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-11: CBIO–to–cCLPA Data Cable RJ45 Connector 4-16 . . . . . . . . . . . . . . .
Figure 4-12: Data Cable Connection Diagram for Compact BTS to cCLPA 4-18 . . .
Figure 4-13: Pole Mounting BracketAssembly 4-20 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-14: Wall Mounting Bracket and cCLPA 4-20 . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-15: Thermal Management Enclosure and Heat Management
System 4-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-16: Bottom View of TME 4-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-17: Wall Mounting Bracket and Pole Mounting Bracket Assembly 4-25 . .
Figure 4-18: TME Screw Mounting Location 4-27 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-19: Thermal Management Enclosure and BTS 4-29 . . . . . . . . . . . . . . . . . .
Figure 4-20: Heat Management System (HMS) 4-30 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-21: HMS Installation 4-31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-22: PDE and Heat Exchanger 4-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-23: PDE Conduit Location 4-33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-24: PDE Detail 4-35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-25: Wall Mounting Bracket and Pole Mounting Bracket Assembly 4-36 . .
Figure 4-26: PDE Mounting Screw Locations 4-39 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-27: PDE Heat Exchanger Dimensions 4-40 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-28: PDE Heat Exchanger Detail 4-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-29: PDE and Heat Exchanger 4-42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-30: Detail Location of Ground Studs 4-48 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-31: Grounding Location on BTS 4-49 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-32: Typical Outdoor Grounding Configuration 4-51 . . . . . . . . . . . . . . . . .
Figure 4-33: Typical Multiple Outdoor Grounding Configuration 4-52 . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU vii
DRAFT
List of Figures – continued
Figure 4-34: Rear View of PDE 4-53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-35: DC Power Terminal Strip 4-55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-36: TME Power Distribution Assembly for +27VDC 4-56 . . . . . . . . . . . . .
Figure 4-37: Antenna Cabling (With cCLPA) 4-60 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-38: Antenna Cabling with 2 cCLPAs 4-61 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-39: Two Antenna Cabling (Without cCLPA) 4-62 . . . . . . . . . . . . . . . . . . . .
Figure 4-40: Three Antenna Cabling (Without cCLPA) 4-63 . . . . . . . . . . . . . . . . . . .
Figure 4-41: Span and RGPS Cabling Details 4-65 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-42: Connector Pins Numbering for Cables C and C1 4-67 . . . . . . . . . . . . .
Figure 4-43: Installing the Remote GPS Head 4-69 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-44: RGPS Head 4-70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-45: RGPS to SC480 Connection Diagram 4-70 . . . . . . . . . . . . . . . . . . . . . .
Figure 4-46: RGPS Lightning Arrestor Wiring 4-71 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-47: RF–GPS Installation and Components 4-73 . . . . . . . . . . . . . . . . . . . . .
Figure 4-48: Span and RF–GPS Cabling Details 4-74 . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4-49: EV–DO Connections 4-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 5-1: DIP Switch Configuration 5-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 5-2: Expansion Frames DIP Switch Configuration 5-2 . . . . . . . . . . . . . . . . .
Figure 5-3: Location of Circuit Breaker 5-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 5-4: Bottom View of cCLPA 5-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-1: LAN Connectors 6-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-2: WinLMF Folder Structure 6-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-3: WinLMF Connection Detail 6-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-4: BTS Login Screen – Identifying Circuit and Packet
BTS Files 6-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-5: Self–Managed Network Elements (NEs) State of a
Packet Mode 6-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-6: Available Packet Mode Commands 6-22 . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-7: Packet Mode Site with MCC–1 and BBX–1 under
LMF Control 6-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-8: LMF Computer Common MMI Connections – Motorola
MMI Interface Kit, SLN2006A 6-31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-9: MMI Connection Detail – Fabricated MMI Cable 6-32 . . . . . . . . . . . . .
Figure 6-10: BTS Ethernet LAN Termination Diagram 6-33 . . . . . . . . . . . . . . . . . .
Figure 6-11: CSA MMI Terminal Connection 6-46 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-12: IS–95A/B and CDMA 2000 1X Cable Calibration
Test Setup –Agilent E4406A/E4432B and Advantest R3267/R3562 6-56 . . . . . . . .
Figure 6-13: IS–95A/B and CDMA 2000 1X Cable Calibration Test Setup –
Agilent E4406A/E4432B and Advantest R3267/R3562 6-57 . . . . . . . . . . . . . . . . . .
viii 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Figures – continued
Figure 6-14: TX Calibration Test Setup – CyberTest (IS–95A/B) and Agilent 8935 (IS–95A/B and CDMA2000 1X) 6-58 . . .
Figure 6-15: TX Calibration Test Setup – Using Power Meter 6-59 . . . . . . . . . . . . .
Figure 6-16: TX Calibration Test Setup –
Agilent E4406A and Advantest R3567 (IS–95A/B and CDMA2000 1X) 6-60 . . . . .
Figure 6-17: IS–95A/B ATP Test Set–up–
CyberTest, Advantest R3465, and Agilent 8935 6-61 . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-18: IS–95A/B ATP Test Setup – HP 8921A 6-62 . . . . . . . . . . . . . . . . . . . .
Figure 6-19: IS–95A/B and CDMA2000 1X ATP Test Setup Agilent
Test Equipment 6-63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-20: IS–95A/B and CDMA2000 1X Optimization/ATP Test Setup – Agilent E4432B/8935 Series E6380A and E4432B/E4406A Test Equipment 6-64 .
Figure 6-21: Cal Setup for TX/Duplexed RX Test Cabling
Using Signal Generator & Spectrum Analyzer 6-72 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6-22: Cal Setup for Non–Duplexed RX Test Cabling Using
Signal Generator & Spectrum Analyzer 6-73 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 7-1: TX Mask Verification Spectrum Analyzer Display 7-13 . . . . . . . . . . . . .
Figure 7-2: Code Domain Analyzer CD Power/Noise Floor Display
Examples 7-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-1: Compact BTS Front Panel Layout without Front Panel
Cover 9-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-2: Compact BTS Fan and CCP2 Shelf Layout 9-3 . . . . . . . . . . . . . . . . . .
Figure 9-3: Fan Module 9-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-4: HSO or MSO Module 9-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-5: HSO or MSO Location 9-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-6: RGPS Head and Mounting Pipe/Conduit 9-13 . . . . . . . . . . . . . . . . . . . .
Figure 9-7: RF–GPS Module 9-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-8: RF–GPS Placement on CBIO Board 9-17 . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-9: Power Supply Module (PSM) 9-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-10: Clock Synchronization and Alarm Card 9-23 . . . . . . . . . . . . . . . . . . . .
Figure 9-11: Group Line Interface 3 Card 9-27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-12: MCC 1X Card 9-31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-13: BBX–1X Card 9-35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-14: Compact Multi–Coupler Preselector Card 9-39 . . . . . . . . . . . . . . . . . . .
Figure 9-15: Compact Multi–Coupler Preselector Card Jumper
Connection 9-40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-16: MCC–DO Card 9-44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-17: CBIO Board with SDCX Removed 9-49 . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-18: SDCX Module 9-52 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-19: CBIO Board with SDCX 9-53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-20: CBIO Board with SDCX Removed 9-54 . . . . . . . . . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU ix
DRAFT
List of Figures – continued
Figure 9-21: cMPC Cable Clip 9-58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-22: Filter Tray Connectors and Cable Part Numbers (SGLN6221) 9-61 . . . Figure 9-23: Filter Tray Connectors and Cable Part Numbers (SGLN6220) 9-62 . . . Figure 9-24: Filter Tray Connectors and Cable Part Numbers (SGLN6219) 9-66 . . .
Figure 9-25: Compact Combined Linear Power Amplifier 9-69 . . . . . . . . . . . . . . . .
Figure 9-26: PDA Location 9-71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-27: Power Distribution Assembly 9-73 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-28:Heat Management System 9-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-29: HMS Heater Elements 9-78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-30: HMS Controller 9-79 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 9-31: Blower Fan 9-81 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-1: Agilent E7495A Pre–Power Sensor Calibration Connection B-4 . . . . .
Figure B-2: Agilent E7495A Power Sensor Calibration Connection B-4 . . . . . . . . .
Figure B-3: Setting Agilent E4406A GPIB Address B-5 . . . . . . . . . . . . . . . . . . . . .
Figure B-4: Setting Agilent E4432B GPIB Address B-6 . . . . . . . . . . . . . . . . . . . . .
Figure B-5: Setting Advantest R3267 GPIB Address B-8 . . . . . . . . . . . . . . . . . . . .
Figure B-6: Advantest R3562 GPIB Address Switch Setting B-9 . . . . . . . . . . . . . .
Figure B-7: Agilent 8935 Test Set B-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-8: HP 8921A and HP 83236A/B B-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-9: R3465 Communications Test Set B-12 . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-10: HP 437 Power Meter B-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-11: Gigatronics 8541C Power Meter Detail B-15 . . . . . . . . . . . . . . . . . . . .
Figure B-12: RS232 GPIB Interface Adapter B-16 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-13: HP 8921A/600 Cable Connections for 10 MHz Signal and
GPIB without Rubidium Reference B-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-14: HP 8921A Cable Connections for 10 MHz Signal and GPIB
with Rubidium Reference B-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-15: Cable Connections for Test Set without 10 MHz Rubidium
Reference B-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-16: Cable Connections for Test Set with 10 MHz Rubidium
Reference B-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-17: Agilent 8935/E4432B 10MHz Reference and Even Second
Tick Connections B-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-18: Agilent 10 MHz Reference Connections B-26 . . . . . . . . . . . . . . . . . . .
Figure B-19: Advantest 10 MHz Reference and Serial I/O Connections B-27 . . . . . .
Figure B-20: Performing Agilent E4406A Self–alignment (Calibration) B-28 . . . . .
Figure B-21: Power Meter Detail B-29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure B-22: Gigatronics 8541C Power Meter Detail B-31 . . . . . . . . . . . . . . . . . . . .
Figure B-23: Cable Calibration Using HP8921 with PCS Interface B-35 . . . . . . . . .
x 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Figures – continued
Figure B-24: Cable Calibration Using Advantest R3465 B-38 . . . . . . . . . . . . . . . . . .
Figure D-1: Fabricated MMI Cable Details D-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure E-1: Three Expansion BTSes Cabling Diagram with Two cCLPAs E-4 . . .
Figure E-2: Two Expansion BTSes Cabling Diagram with Two cCLPAs E-6 . . . . .
Figure E-3: One Expansion BTS Cabling Diagram with Two cCLPAs E-8 . . . . . . .
Figure E-4: Three Expansion BTSes Cabling Diagram with One cCLPA E-11 . . . . .
Figure E-5: Two Expansion BTSes Cabling Diagram with One cCLPA E-13 . . . . . .
Figure E-6: One Expansion BTS Cabling Diagram with One cCLPA E-15 . . . . . . . .
Figure E-7: Three Expansion BTSes Cabling Diagram E-17 . . . . . . . . . . . . . . . . . . .
Figure E-8: Two Expansion BTSes Cabling Diagram E-18 . . . . . . . . . . . . . . . . . . . .
Figure E-9: One Expansion BTS Cabling Diagram E-19 . . . . . . . . . . . . . . . . . . . . . .
Figure E-10: Three Expansion BTSes Cabling Diagram E-24 . . . . . . . . . . . . . . . . . .
Figure E-11: Outdoor Two Expansion BTSes Cabling Diagram E-25 . . . . . . . . . . . .
Figure E-12: Outdoor One Expansion BTS Cabling Diagram E-26 . . . . . . . . . . . . . .
Figure F-1: Three Expansion BTSes LAN Cabling Diagram F-1 . . . . . . . . . . . . . .
Figure F-2: Two Expansion BTSes LAN Cabling Diagram F-2 . . . . . . . . . . . . . . . .
Figure F-3: One Expansion BTS LAN Cabling Diagram F-2 . . . . . . . . . . . . . . . . .
Figure H-1: Cabling Compact BTS Packet Operation Integrated BTS Router Spans –
One Span H-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure J-1: Typical Highway Cell Configuration Diagram J-2 . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xi
DRAFT
List of Tables
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU
Software Release 2.16.5.X
FCC Part 68 Registered Devices xxiv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1-1: Abbreviations and Acronyms 1-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1-2: 1900 MHz TX and RX Frequency vs. Channel 1-9 . . . . . . . . . . . . . . . .
Table 1-3: Recommended Tools and Materials for Rack Mounting 1-11 . . . . . . . . . .
Table 1-4: CCP2 Shelf Card/Module Device ID Numbers for Logical BTS 1-21 . . .
Table 1-5: Shelf Device ID Numbers 1-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-1: Procedure to Prepare the Site for the BTS 2-6 . . . . . . . . . . . . . . . . . . . .
Table 2-2: Recommended Unpacking Tools 2-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-3: Unpacking Equipment from a Cardboard or Wood Container 2-11 . . . . .
Table 2-4: Procedure to Remove Outdoor Equipment from Container 2-11 . . . . . . .
Table 2-5: Procedure to Remove Indoor Equipment from Container 2-13 . . . . . . . . .
Table 2-6: Installation Dimensions for the BTS 2-14 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-7: Minimum Clearances for the BTS 2-14 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-8: Installation Dimensions for the cCLPA 2-16 . . . . . . . . . . . . . . . . . . . . . . .
Table 2-9: Minimum Clearances for the cCLPA 2-16 . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-10: Installation Dimensions for the TME 2-20 . . . . . . . . . . . . . . . . . . . . . . .
Table 2-11: Minimum Clearances for the TME 2-20 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-12: Installation Dimensions for the PDE 2-23 . . . . . . . . . . . . . . . . . . . . . . . .
Table 2-13: Minimum Clearances for the PDE 2-23 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-1: Cable Descriptions and Part Numbers 3-2 . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-2: Cables Needed for Antenna Connections 3-6 . . . . . . . . . . . . . . . . . . . . .
Table 3-3: Pin and Signal Information for Cable B (Antenna Cable) 3-6 . . . . . . . .
Table 3-4: Cables Needed for Span/RGPS Connections 3-7 . . . . . . . . . . . . . . . . . .
Table 3-5: Pin/Signal Information for Span Cable 3-7 . . . . . . . . . . . . . . . . . . . . . . .
Table 3-6: Cables Needed for Span/RGPS Connections 3-8 . . . . . . . . . . . . . . . . . .
Table 3-7: RGPS Pin/Signal Name Information 3-8 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-8: Cabling for Local GPS 3-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3-9: Local GPS Antenna Mounting Considerations 3-12 . . . . . . . . . . . . . . . . .
Table 4-1: Procedure to Attach Mounting Plate to Rack 4-6 . . . . . . . . . . . . . . . . . .
xii 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Tables – continued
Table 4-2: Procedure to Attach BTS Mounting Bracket 4-7 . . . . . . . . . . . . . . . . . .
Table 4-3: Procedure to Attach BTS to Mounting Plate 4-8 . . . . . . . . . . . . . . . . . . .
Table 4-4: DC Input Cable Description and Part Number 4-10 . . . . . . . . . . . . . . . . .
Table 4-5: Procedure to Mount the Power Amplifier 4-11 . . . . . . . . . . . . . . . . . . . . .
Table 4-6: Ground Cable and Lug Description and Part Number 4-12 . . . . . . . . . . .
Table 4-7: Procedure to Ground the cCLPA 4-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-8: Procedure to Attach DC Power Cable to the cCLPA 4-14 . . . . . . . . . . . .
Table 4-9: Data Cable Description and Part Number 4-16 . . . . . . . . . . . . . . . . . . . . .
Table 4-10: Data Cable Wiring Scheme 4-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-11: Procedure to Attach BTS Data Cable to cCLPA 4-17 . . . . . . . . . . . . . . .
Table 4-12: Procedure to Pole or Wall Mount the cCLPA 4-19 . . . . . . . . . . . . . . . . .
Table 4-13: TME Conduit Sizes 4-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-14: Procedure to Pole Mount the TME 4-24 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-15: Procedure to Install Mounting Bracket on a Wall 4-26 . . . . . . . . . . . . . .
Table 4-16: Procedure to Install Compact BTS in a TME 4-28 . . . . . . . . . . . . . . . . .
Table 4-17: Procedure to Install the HMS 4-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-18: Conduit Sizes 4-34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-19: Procedure to Install Mounting Bracket Assembly on a Pole 4-37 . . . . .
Table 4-20: Procedure to Install the Wall Mounting Bracket on a Wall 4-38 . . . . . . .
Table 4-21: Procedure to Install the Heat Exchanger 4-41 . . . . . . . . . . . . . . . . . . . . .
Table 4-22: PDE Punchblock Wiring Descriptions 4-42 . . . . . . . . . . . . . . . . . . . . . .
Table 4-23: Ground Cable and Lug Description and Part Number 4-47 . . . . . . . . . .
Table 4-24: Procedure to Attach the Earth Ground Cable 4-48 . . . . . . . . . . . . . . . . .
Table 4-25: Procedure to Ground an Outdoor Site 4-50 . . . . . . . . . . . . . . . . . . . . . .
Table 4-26: DC Input Cable Description and Part Number 4-54 . . . . . . . . . . . . . . . .
Table 4-27: Procedure to Connect DC Power to the BTS 4-54 . . . . . . . . . . . . . . . . .
Table 4-28: Procedure to Connect DC Power to the BTS 4-56 . . . . . . . . . . . . . . . . .
Table 4-29: AC Input Cable Description and Part Number 4-57 . . . . . . . . . . . . . . . .
Table 4-30: Cable Descriptions and Part Numbers 4-59 . . . . . . . . . . . . . . . . . . . . . . .
Table 4-31: Procedure to Install Antenna Cables 4-59 . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-32: List of Required Cables 4-64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-33: Pin/Signal Information for Span Cable 4-66 . . . . . . . . . . . . . . . . . . . . . .
Table 4-34: Procedure to Install 1X or DO Span Cable 4-66 . . . . . . . . . . . . . . . . . . .
Table 4-35: Pinout for Cables C and C1 4-67 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-36: Procedure for Installing the RGPS Head and Cabling 4-68 . . . . . . . . . .
Table 4-37: Procedure for Installing RF–GPS Antenna and Cabling 4-71 . . . . . . . . .
Table 4-38: Cable Descriptions and Part Numbers 4-76 . . . . . . . . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xiii
DRAFT
List of Tables – continued
Table 4-39: Customer Input Connector Pinouts 4-76 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-40: Customer Input Connector Pinouts 4-77 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-41: Procedure for Using Ferrite Core on Customer Input and
Output Wires 4-77 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4-42: Indoor Installation Completion Checklist 4-79 . . . . . . . . . . . . . . . . . . . .
Table 5-1: Frame ID Switch Position – Single/Starter Frame 5-2 . . . . . . . . . . . . . .
Table 5-2: Frame ID Switch Position – Expansion 1 Frame 5-3 . . . . . . . . . . . . . . .
Table 5-3: Frame ID Switch Position – Expansion 2 Frame 5-3 . . . . . . . . . . . . . . .
Table 5-4: Frame ID Switch Position – Expansion 3 Frame 5-3 . . . . . . . . . . . . . . .
Table 5-5: BTS DC Pre–Power Test 5-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-6: cCLPA DC Pre–Power Test 5-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-7: PDE Initial Power –Up Test 5-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-8: Cable Descriptions and Part Numbers 5-9 . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-9: Procedure to Verify Battery Backup DC Power Test 5-9 . . . . . . . . . . . .
Table 5-10: Procedure for BTS Initial Power–Up 5-11 . . . . . . . . . . . . . . . . . . . . . . .
Table 5-11: Procedure cCLPA Initial Power–Up 5-11 . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-12: TME DC Initial Power–Up Test 5-12 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-13: Procedure to Remove Power to BTS 5-14 . . . . . . . . . . . . . . . . . . . . . . . .
Table 5-14: Procedure to Remove Power to cCLPA 5-14 . . . . . . . . . . . . . . . . . . . . .
Table 5-15: Procedure to Remove Power to PDE 5-14 . . . . . . . . . . . . . . . . . . . . . . .
Table 6-1: Initial Installation of Boards/Modules 6-2 . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-2: Install WinLMF using CD ROM 6-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-3: Copying CDF or NECF Files to the WinLMF Computer 6-12 . . . . . . . . .
Table 6-4: Create HyperTerminal Connection 6-14 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-5: T1/E1 Span Isolation 6-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-6: Connecting the WinLMF to the BTS 6-17 . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-7: BTS GUI Login Procedure 6-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-8: BTS CLI Login Procedure 6-27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-9: BTS GUI Logout Procedure 6-28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-10: BTS CLI Logout Procedure 6-29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-11: Establishing MMI Communication 6-30 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-12: Pinging the Processors 6-34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-13: Verify GLI ROM Code Loads 6-38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-14: Download and Enable GLI Device 6-39 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-15: Download RAM Code and Data to Non–GLI Devices 6-40 . . . . . . . . . .
Table 6-16: Select CSA Clock Source 6-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-17: Enable CSA 6-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiv 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Tables – continued
Table 6-18: Enable MCCs 6-42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-19: Test Equipment Setup (GPS & HSO/MSO Verification) 6-45 . . . . . . . .
Table 6-20: GPS Initialization/Verification 6-47 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-21: IS–95A/B–only Test Equipment Interconnection 6-53 . . . . . . . . . . . . . .
Table 6-22: CDMA2000 1X/IS–95A/B Test Equipment Interconnection 6-54 . . . . .
Table 6-23: Procedure for Selecting Test Equipment Manually in the
Serial Connection Tab 6-67 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-24: Procedure for Selecting Test Equipment Using Auto-Detect 6-68 . . . . .
Table 6-25: Procedure for Test Equipment Calibration 6-69 . . . . . . . . . . . . . . . . . . .
Table 6-26: Procedure to Test Cabling Calibration using Communication
System Analyzer 6-70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-27: Procedure to Calibrate TX/Duplexed RX Test Cabling Using
Signal Generator & Spectrum Analyzer 6-71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-28: Procedure for Calibrating Non–Duplexed RX Test Cabling
Using Signal Generator & Spectrum Analyzer 6-72 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-29: Procedure for Setting Cable Loss Values 6-73 . . . . . . . . . . . . . . . . . . . .
Table 6-30: Procedure for Setting TX and RX Directional Coupler
Loss Values 6-74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-31: Procedure to Set Up Test Equipment for RF Path Calibration 6-78 . . . .
Table 6-32: Maximum and Minimum Power 6-79 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-33: Test Patterns with Channels and Gain Settings Used 6-81 . . . . . . . . . . .
Table 6-35: Procedure for All Cal/Audit and TX Calibration 6-83 . . . . . . . . . . . . . .
Table 6-36: Procedure to Download BLO 6-85 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-37: Procedure for BTS TX Path Audit 6-86 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6-38: Create CAL File 6-88 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-1: Set Up Test Equipment – TX Output Verify/Control Tests 7-4 . . . . . . . .
Table 7-2: All TX/RX ATP Test Procedure 7-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-3: All TX ATP Test Procedure 7-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-4: All RX ATP Test Procedure 7-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-5: Test Spectral Purity Transmit Mask 7-11 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-6: Test Waveform Quality (Rho) 7-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-7: Test Pilot Time Offset 7-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-8: Test Code Domain Power/Noise Floor 7-19 . . . . . . . . . . . . . . . . . . . . . . .
Table 7-9: Test FER 7-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7-10: Generating an ATP Report 7-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8-1: Copying CAL Files to a Diskette 8-1 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8-2: Copying CAL Files from Diskette to the CBSC 8-2 . . . . . . . . . . . . . . . .
Table 8-3: Remove External Test Equipment 8-3 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8-4: Bring Modules into Service 8-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xv
DRAFT
List of Tables – continued
Table 8-5: Terminate the WinLMF Session and Remove the WinLMF 8-4 . . . . . . .
Table 8-6: Connect T1 or E1 Spans 8-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8-7: Check Before Leaving the Site 8-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 8-8: Reset BTS Devices and Remote Site Initialization 8-5 . . . . . . . . . . . . . .
Table 9-1: Procedure to Remove Fan Module 9-5 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-2: Procedure to Install Fan Module 9-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-3: Procedure to Remove HSO or MSO Module 9-8 . . . . . . . . . . . . . . . . . .
Table 9-4: Procedure to Install HSO or MSO Module 9-8 . . . . . . . . . . . . . . . . . . . .
Table 9-5: Procedure to Remove RGPS Head 9-12 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-6: Procedure to Install RGPS Head 9-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-7: Procedure to Remove RF–GPS 9-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-8: Procedure to Install RF–GPS 9-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-9: Procedure to Remove Power Supply Module 9-19 . . . . . . . . . . . . . . . . . .
Table 9-10: Procedure to Install Power Supply Module 9-19 . . . . . . . . . . . . . . . . . . .
Table 9-11: Procedure to Remove CSA Module 9-21 . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-12: Procedure to Install CSA Module 9-22 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-13: Procedure to Remove GLI3 Card 9-25 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-14: Procedure to Install GLI3 Card 9-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-15: Procedure to Recover GLI3 Card 9-26 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-16: Procedure to Remove MCC–1X Card 9-29 . . . . . . . . . . . . . . . . . . . . . . .
Table 9-17: Procedure to Install MCC–1X Card 9-30 . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-18: Procedure to Remove BBX–1X Card 9-34 . . . . . . . . . . . . . . . . . . . . . . .
Table 9-19: Procedure to Install BBX–1X Card 9-34 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-20: cMPC PWR/ALM LED State 9-36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-21: Procedure to Remove cMPC 9-37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-22: Procedure to Install cMPC 9-38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-23: MCC–DO LED States 9-41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-24: Procedure to Remove MCC–DO Card 9-42 . . . . . . . . . . . . . . . . . . . . . .
Table 9-25: Procedure to Install MCC–DO Card 9-43 . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-26: Procedure to Remove CBIO Board 9-46 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-27: Procedure to Install CBIO Board 9-47 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-28: Procedure to Remove SDCX 9-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-29: Procedure to Install SDCX 9-51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-30: Preparation Procedure for Removing the Filter Tray 9-56 . . . . . . . . . . .
Table 9-31: Procedure to Remove Filter Tray Kit SGLN6221 9-57 . . . . . . . . . . . . . .
Table 9-32: Procedure to Remove cMPC Cable Clip 9-57 . . . . . . . . . . . . . . . . . . . . .
Table 9-33: Procedure to Install cMPC Cable Clip 9-58 . . . . . . . . . . . . . . . . . . . . . .
xvi 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Tables – continued
Table 9-34: Procedure to Install Filter Tray Kit SGLN6221 9-58 . . . . . . . . . . . . . . .
Table 9-35: Procedure to Remove Filter Tray Kit SGLN6220 9-61 . . . . . . . . . . . . . .
Table 9-36: Procedure to Install Filter Tray Kit SGLN6220 9-63 . . . . . . . . . . . . . . .
Table 9-37: Procedure to Remove Filter Tray Kit SGLN6219 9-65 . . . . . . . . . . . . . .
Table 9-38: Procedure to Install Filter Tray Kit SGLN6222 or SGLN6219 9-65 . . .
Table 9-39: Procedure to Remove cCLPA 9-67 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-40: Procedure to Install cCLPA 9-68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-41: Procedure to Remove PDA 9-71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-42: Procedure to Install PDA 9-72 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-43: Procedure to Remove HMS 9-76 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-44: Procedure to Re–install HMS 9-76 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-45: Procedure to Replace Heater Elements 9-77 . . . . . . . . . . . . . . . . . . . . . .
Table 9-46: Procedure to Install Heater Elements 9-77 . . . . . . . . . . . . . . . . . . . . . . .
Table 9-47: Procedure to Replace HMS Controller 9-78 . . . . . . . . . . . . . . . . . . . . . .
Table 9-48: Procedure to Install HMS Controller 9-79 . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-49: Procedure to Replace Blower Fan 9-80 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-50: Procedure to Install Blower Fan 9-80 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-51: Procedure to Remove TME 9-82 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-52: Procedure to Install TME 9-83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-53: Fan Module Item Number List 9-86 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-54: HSO or MSO Module Item Number List 9-86 . . . . . . . . . . . . . . . . . . . .
Table 9-55: RGPS Item Number List 9-86 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-56: RF GPS Module Item Number List 9-86 . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-57: PSM Item Number List 9-87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-58: CSA Card Item Number List 9-87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-59: GLI3 Card Item Number List 9-87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-60: MCC–1X Card Item Number List 9-87 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-61: BBX–1X Card Item Number List 9-88 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-62: Compact MPC Item Number List 9-88 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-63: MCC–DO Card Item Number List 9-88 . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-64: CBIO Board Item Number List 9-88 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-65: SDCX Module Item Number List 9-88 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-66: Filter Tray Kit Item Number List 9-89 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-67: cCLPA Item Number List 9-89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-68: TME PDA Item Number List 9-89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-69: TME HMS Item Number List 9-89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9-70: TME HMS Heater Element Item Number List 9-90 . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xvii
DRAFT
List of Tables – continued
Table 9-71: TME HMS Controller Item Number List 9-90 . . . . . . . . . . . . . . . . . . . .
Table 9-72: TME HMS Blower Fan Item Number List 9-90 . . . . . . . . . . . . . . . . . . .
Table 10-1: Login and Access Alarm Window Procedure 10-2 . . . . . . . . . . . . . . . . .
Table 10-2: Shut Down Site Signaling Functions Procedure For a
Circuit BTS 10-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-3: Shut Down Sector Signaling Functions Procedure For a
Circuit BTS 10-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-4: Shut Down Carrier Signaling Functions Procedure For a
Circuit BTS 10-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-5: Restore Site Signaling Operations Procedure For a
Circuit BTS 10-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-6: Restore Sector Signaling Operations Procedure For a
Circuit BTS 10-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-7: Restore Carrier Signaling Operations Procedure For a
Circuit BTS 10-29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-8: Shut Down Site Signaling Functions Procedure For a
Packet BTS 10-33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-9: Shut Down Sector Signaling Functions Procedure For a
Packet BTS 10-40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-10: Shut Down Carrier Signaling Functions Procedure For a
Packet BTS 10-47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-11: Restore Site Signaling Operations Procedure For a
Packet BTS 10-53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-12: Restore Sector Signaling Operations Procedure For a
Packet BTS 10-56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 10-13: Restore Carrier Signaling Operations Procedure For a
Packet BTS 10-59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 11-1: Login Failure Troubleshooting Procedures 11-1 . . . . . . . . . . . . . . . . . . .
Table 11-2: Force Ethernet LAN A to Active State as Primary LAN 11-2 . . . . . . . .
Table 11-3: GLI IP Address Setting 11-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 11-4: Troubleshooting a Power Meter Communication Failure 11-5 . . . . . . . .
Table 11-5: Troubleshooting a Communications System Analyzer
Communication Failure 11-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 11-6: Troubleshooting a Signal Generator Communication Failure 11-6 . . . . .
Table 11-7: Troubleshooting Code Download Failure 11-6 . . . . . . . . . . . . . . . . . . . .
Table 11-8: Troubleshooting Data Download Failure 11-7 . . . . . . . . . . . . . . . . . . . .
Table 11-9: Troubleshooting Device Enable (INS) Failure 11-7 . . . . . . . . . . . . . . . .
Table 11-10: cCLPA Errors 11-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table A-1: Procedure to Test MCC–DO Code Domain Power A-2 . . . . . . . . . . . . .
Table A-2:Procedure to Test the MCC–DO TX Mask A-4 . . . . . . . . . . . . . . . . . . . .
Table A-3: Procedure to Test MCC–DO Pilot Time Offset A-6 . . . . . . . . . . . . . . . .
Table A-4: Procedure to Test MCC–DO Rho A-8 . . . . . . . . . . . . . . . . . . . . . . . . . . .
xviii 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
List of Tables – continued
Table A-5: Procedure to Test MCC–DO Packet Error Rate A-10 . . . . . . . . . . . . . . . .
Table B-1: Set IP Address on Agilent E7495A test set B-2 . . . . . . . . . . . . . . . . . . .
Table B-2: Detecting Agilent E7495A Test Equipment B-3 . . . . . . . . . . . . . . . . . . .
Table B-3: E7495A Power Sensor Calibration B-3 . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-4: Verify and Change Agilent E4406A GPIB Address B-5 . . . . . . . . . . . . .
Table B-5: Verify and Change Agilent E4432B GPIB Address B-7 . . . . . . . . . . . . .
Table B-6: Verify and Change Advantest R3267 GPIB Address B-8 . . . . . . . . . . . .
Table B-7: Verify and/or Change Agilent 8935 (formerly HP 8935) GPIB
Address B-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-8: Verify and/or Change HP 8921A and HP 83236A GPIB
Addresses B-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-9: Verify and/or Change Advantest R3465 GPIB Address B-12 . . . . . . . . . .
Table B-10: Verify and/or Change Motorola CyberTest GPIB Address B-13 . . . . . .
Table B-11: Verify and/or Change HP 437 Power Meter GPIB Address B-14 . . . . . .
Table B-12: Verify and/or Change Gigatronics 8541C Power Meter GPIB
Address B-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-13: HP 8921A/600 Communications Test Set Rear Panel
Connections Without Rubidium Reference B-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-14: HP 8921A/600 Communications Test Set Rear Panel
Connections With Rubidium Reference B-19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-15: System Connectivity B-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-16: Pretest Setup for HP 8921A B-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-17: Pretest Setup for Agilent 8935 B-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-18: Advantest R3465 Clock Setup B-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-19: Pretest Setup for Advantest R3465 B-25 . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-20: Perform Agilent E4406A Self–alignment (Calibration) B-28 . . . . . . . . .
Table B-21: HP 437 Power Meter Calibration Procedure B-29 . . . . . . . . . . . . . . . . .
Table B-22: Calibrate Gigatronics 8541C Power Meter B-31 . . . . . . . . . . . . . . . . . . .
Table B-23: Calibrating Test Cable Setup (using the HP PCS Interface) B-32 . . . . .
Table B-24: Procedure for Calibrating Test Cable Setup Using
Advantest R3465 B-36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table C-1: Download ROM and RAM Code to Devices C-2 . . . . . . . . . . . . . . . . . .
Table D-1: Parts Required to Fabricate MMI Cable D-1 . . . . . . . . . . . . . . . . . . . . . .
Table D-2: Fabricated MMI Cable Wire Run List D-2 . . . . . . . . . . . . . . . . . . . . . . .
Table E-1: Combiner and Directional Coupler Specifications E-1 . . . . . . . . . . . . . .
Table E-2: Procedure for Installing Expansion Compact BTS with
Dual cCLPA E-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table E-3: Starter and Three Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Dual cCLPA E-3 . . . . . . . . . . . . . . . . . . .
Table E-4: Starter and Two Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Dual cCLPA E-5 . . . . . . . . . . . . . . . . . . .
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xix
DRAFT
List of Tables – continued
Table E-5: Starter and One Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Dual cCLPA E-7 . . . . . . . . . . . . . . . . . . .
Table E-6: Procedure for Installing Expansion Compact BTS with
Single cCLPA E-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table E-7: Starter and Three Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Single cCLPA E-10 . . . . . . . . . . . . . . . . . .
Table E-8: Starter and Two Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Single cCLPA E-12 . . . . . . . . . . . . . . . . . .
Table E-9: Starter and One Expansion BTS Interconnect Cabling
for Circuit or Packet Configuration with Single cCLPA E-14 . . . . . . . . . . . . . . . . . .
Table E-10: Procedure for Installing Expansion Compact BTS
without cCLPA E-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table E-11: BBX (Carrier) to cCLPA Via RS485 E-20 . . . . . . . . . . . . . . . . . . . . . . .
Table E-12: Starter and Three Expansion BTS Cabling for
Circuit or Packet to Dual cCLPAs E-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table E-13: Starter and Two Expansion BTS Cabling for
Circuit or Packet to Dual cCLPAs E-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table E-14: Starter and One Expansion BTS Cabling for
Circuit or Packet to Dual cCLPAs E-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table E-15: Combiner and Directional Coupler Specifications E-22 . . . . . . . . . . . . .
Table E-16: Procedure for Installing Expansion Compact BTSes E-23 . . . . . . . . . . .
Table F-1: Procedure for Installing LAN Cabling for Logical BTS F-3 . . . . . . . . . .
Table G-1: Suggested Preliminary Verification Locations G-1 . . . . . . . . . . . . . . . . .
Table G-2: Verify GLI3 Software Version and Span Parameter Settings G-3 . . . . . .
Table G-3: Set GLI3 Span Parameter Configuration G-6 . . . . . . . . . . . . . . . . . . . . .
Table H-1: Implement IBR Functionality in New BTS H-2 . . . . . . . . . . . . . . . . . . .
Table H-2: BTS Span Cables H-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xx 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
Foreword
Scope of manual
Obtaining manuals
This manual is intended for use by cellular telephone system craftspersons in the day-to-day operation of Motorola cellular system equipment and ancillary devices.
This manual is not intended to replace the system and equipment training offered by Motorola, although it can be used to supplement or enhance the knowledge gained through such training.
To view, download, or order manuals (original or revised), visit the Motorola Lifecycles Customer web page at
https://mynetworksupport.motorola.com/
account representative. If Motorola changes the content of a manual after the original printing
date, Motorola publishes a new version with the same part number but a different revision character.
, or contact your Motorola
Text conventions
The following special paragraphs are used in this manual to point out information that must be read. This information may be set-off from the surrounding text, but is always preceded by a bold title in capital letters. The four categories of these special paragraphs are:
NOTE
Presents additional, helpful, non-critical information that you can use.
IMPORTANT
*
Presents information to help you avoid an undesirable situation or provides additional information to help you understand a topic or concept.
CAUTION
Presents information to identify a situation in which damage to software, stored data, or equipment could occur, thus avoiding the damage.
WARNING
Presents information to warn you of a potentially hazardous situation in which there is a possibility of personal injury.
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xxi
DRAFT
Foreword – continued
Reporting manual errors
The following typographical conventions are used for the presentation of software information:
S In text, sans serif BOLDFACE CAPITAL characters (a type style
without angular strokes: for example, SERIF versus SANS SERIF) are used to name a command.
S In text, typewriter style characters represent prompts and the
system output as displayed on an operator terminal or printer.
S In command definitions, sans serif boldface characters represent
those parts of the command string that must be entered exactly as shown and typewriter style characters represent command output responses as displayed on an operator terminal or printer.
S In the command format of the command definition, typewriter
style characters represent the command parameters.
To report a documentation error, call the CNRC (Customer Network Resolution Center) and provide the following information to enable CNRC to open an SR (Service Request): – the document type – the manual title, part number, and revision character – the page number(s) with the error – a detailed description of the error and if possible the proposed solution Motorola appreciates feedback from the users of our manuals.
Contact us
Manual banner definitions
24-hour support service
Send questions and comments regarding user documentation to the email address below: cdma.documentation@motorola.com
Motorola appreciates feedback from the users of our information.
A banner (oversized text on the bottom of the page, for example, PRELIMINARY) indicates that some information contained in the manual is not yet approved for general customer use.
If you have problems regarding the operation of your equipment, please contact the Customer Network Resolution Center (CNRC) for immediate assistance. The 24 hour telephone numbers are:
North America +1–800–433–5202 Europe, Middle East, Africa +44– (0) 1793–565444 Asia Pacific +86–10–88417733
Japan & Korea +81–3–5463–3550. . . . . . . . . . .
For further CNRC contact information, contact your Motorola account representative.
xxii 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
FCC Requirements
Content
FCC Part 15 Requirements
This section presents the Federal Communications Commission (FCC) Rules Parts 15 and 68 requirements and compliance information for the SC480 domestic series Radio Frequency Base TransceiverStations.
Part 15.19a(3) – Information to User
NOTE
This device complies with Part 15 of the FCC Rules. Operationis subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, includinginterference that may cause undesired operation.
Part 15.21 – Information to User
CAUTION
Changes or modifications not expressly approved by Motorolacould void your authority to operate the equipment.
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xxiii
DRAFT
FCC Requirements – continued
Part 15.105(b) – Information to User
NOTE
This equipment has been tested and found to comply with thelimits for a Class B digital device, pursuant to Part 15 of theFCC Rules. These limits are designed to provide reasonableprotection against harmful interference in a residentialinstallation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordancewith the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee thatinterference will not occur in a particular installation. If thisequipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipmentOFF and ON, the user is encouraged to try to correct theinterference by one or more of the following measures:
S Reorient or relocate the receiving antenna. S Increase the separation between the equipment and
receiver.
S Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
S Consult the dealer or an experienced radio/TV
technician for help.
Part 68 Requirements
This equipment complies with Part 68 of the Federal CommunicationsCommission (FCC) Rules. A label on the GLI3 board, easily visiblewith the board removed, contains the FCC Registration Number for thisequipment. If requested, this information must be provided to the telephone company.
FCC Part 68 Registered Devices
Device FCC Part 68 ID
SC480–800MHz 1X/EVDO See Note US: IHEDENANSC4801XDO
NOTE
The SC480–800MHz 1X/EVDO BTS is registered with an FCC part number (US: IHEDENANSC4801XDO) which will cover all the internal cards and modules.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of your T1. If this happens, the telephone company will provide advance notice so that you can modify your equipment as required to maintain uninterrupted service.
xxiv 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
FCC Requriements – continued
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
If you experience trouble operating this equipment with the T1, please contact:
Global Customer Network Resolution Center (CNRC) 1501 W. Shure Drive, 3436N Arlington Heights, Illinois 60004 Phone Number: (847) 632–5390
for repair and/or warranty information. You should not attempt to repair this equipment yourself. This equipment contains no customer or user–serviceable parts.
Changes or modifications not expressly approved by Motorola could void your authority to operate this equipment.
FCC Label and Location
LABEL SHOWN ISFOR DISPLAY PURPOSES ONLY.
CCLPA
BTS
Label placed
here
Model No. Motorola
Model No. ___________
MOTOROLA
SERIAL NO.
FCC ID IHET5EJ1
FCC ID: IHET6EK1
Complies with Part 68, FCC Rules
FCC Reg. No.
US: IHEDENANSC4801XDO
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xxv
DRAFT
General Safety
Remember! . . . Safety depends on you!!
Ground the instrument
The following general safety precautions must be observed during all phases of operation, service, and repair of the equipment described in this manual. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the equipment. Motorola, Inc. assumes no liability for the customer’s failure to comply with these requirements. The safety precautions listed below represent warnings of certain dangers of which we are aware. You, as the user of this product, should follow these warnings and all other safety precautions necessary for the safe operation of the equipment in your operating environment.
To minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical ground. If the equipment is supplied with a three-conductor ac power cable, the power cable must be either plugged into an approved three-contact electrical outlet or used with a three-contact to two-contact adapter. The three-contact to two-contact adapter must have the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable must meet International Electrotechnical Commission (IEC) safety standards.
Do not operate in an explosive atmosphere
Keep away from live circuits
NOTE
Refer to Grounding Guideline for Cellular Radio Installations – 68P81150E62.
Do not operate the equipment in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment constitutes a definite safety hazard.
Operating personnel must:
S not remove equipment covers. Only Factory Authorized Service
Personnel or other qualified maintenance personnel may remove equipment covers for internal subassembly, or component replacement, or any internal adjustment.
S not replace components with power cable connected. Under certain
conditions, dangerous voltages may exist even with the power cable removed.
S always disconnect power and discharge circuits before touching them.
xxvi 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
General Safety – continued
Do not service or adjust alone
Do not substitute parts or modify equipment
Dangerous procedure warnings
Do not attempt internal service or adjustment, unless another person, capable of rendering first aid and resuscitation, is present.
Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification of equipment. Contact Motorola Warranty and Repair for service and repair to ensure that safety features are maintained.
Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. You should also employ all other safety precautions that you deem necessary for the operation of the equipment in your operating environment.
WARNING
Dangerous voltages, capable of causing death, are present in this equipment. Use extreme caution when handling, testing, and adjusting.
Jun 2004 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU xxvii
DRAFT
Revision History
Manual Number
Manual Title
Version Information
68P09262A08–1
1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Software Release 2.16.5.X
The following table lists the manual version, date of version, and remarks on the version.
Version
Level
–1 Jun 18, 2004 DRAFT – For General engineering review
Date of Issue Remarks
xxviii 1X SC480 BTS Hardware Installation, Optimization/ATP, and FRU Jun 2004
DRAFT
Loading...
+ 150 hidden pages