has a modular connector,
and is used with the service Audio Box JBA-4 or a
modular T-adapter.
DDC-1Power Pack0670405The Power Pack provides
the phone with power via
FLA-39. The phone’s own
battery can be used in
DDC-1.
Note: DDC-1 allows battery charging. When it is
used as a charger, the
power pack need to be
disconnected.
Note: When DDC-1 is used
as a Power Pack, battery
charging is not allowed!
FPS-8CHeavy Flash Prommer0080396The FPS-8C is used for
heavy flashing.
GAC-1Galvanic Connector0770301The GAC-1 adapter is
needed for the RF connection. The GAC-1
adapter makes galvanic
connections to assembled handset RF-switches
possible. Via this adapter,
the handset is connected
to the RF measuring and
test equipment.
JBA-8Audio Box0770320The Audio Box is needed
for audio connections.
The box must support
DCT4 Janette audios.
The Service Audio box
provides an interconnection between the phone’s
system connector (XEAR,
XMIC) through a fixed
audio cable and Audio
tester with a BNC-BNC
coax. The connection to a
PC can be made with the
service battery, through a
DAU-9 cable. The Service
Audio Box JBA-8 is used
for service purposes.
JBV-1Docking Station0770298The Docking Station and
the Docking Station
Adapter (MJF-23) are
needed for Mbus, Fbus,
RF, and audio connections.
This setup allows connection between flash prommers. When the audio box
is connected, it has to be
connected to the phone’s
audio connector. The
Docking Station can be
powered by FPS-8 or
external power supply.
MJF-23Docking Station Adapter0770489The Docking Station
Adapter, together with
the Docking Station
(JBV-1), are needed for
Mbus, Fbus, RF, and audio
connections.
This setup allows connection between flash prommers. When the audio box
is connected, it has to be
connected to the phone’s
audio connector. The
Docking Station can be
powered by FPS-8 or
external power supply.
MJS-18Module Jig0770299This jig allow phone
PWB-level service and
troubleshooting.
Electric circuits have to
be protected against
over-voltage and overcurrent.
MJS-27Soldering Jig0775287This jig allows phone
PWB level service and
troubleshooting for
authorized service centers.
PCS-1Power Cable0730012The Power Cable PCS-1 is
used to connect the service tools (JBV-1, MJS-57)
to an external power supply.
is hardware device that,
when connected to the
parallel (LPT) port of the
PC, enables the use of the
service software. Without the dongle present, it
is not possible to use the
service software. Printers
or other peripheral
devices can be connected
to the PC through the
dongle, if needed.
Caution: Make sure that
you have switched off the
PC and the printer before
making connections!
Caution: Do not connect
the PKD-1 to the serial
port. You may damage
your PKD-1!
SCB-3DC Cable 0730114The DC Cable SCB-3 is
used to connect the
docking station to the
charger connection (Vin)
of the phone to conduct
the charger calibration
service procedure.
XCS-4Mbus/Fbus Cable0730178The XCS-4 Service Cable
is a modular cable for
flashing DCT4 products.
XRF-1RF Cable0730085RF Cable XRF-1 is used to
connect the service tools
to RF measuring equipment.
Flashing, testing, and tuning with covers on (Setups 2a, 2b, 2c, 2d)
Tightened performance specifications require more precise equipment and methods for
testing and alignment. Manual tuning can’t provide accurate results for RH-41 products,
which means that this task has to be automated.
These setups are intended to be used with either Phoenix or Darium SW. With the Phoenix SW, it is possible to do manual testing and automated tuning. With Darium, it is possible to do automated testing and tuning.