Nokia ONEBTS-27 Users manual

APPLICANT: Alcatel-Lucent USA, Inc. Exhibit 10 FCC ID: AS5ONEBTS-27
EXHIBIT 10: USERS MANUAL
§ 2.1033 Application for certification.
(c) Applications for equipment other than that operating under parts 15 and 18 of the rules shall be accompanied by a technical report containing the following information:
(3) A copy of the installation and operating instructions to be furnished the user. A draft copy of the instructions may be submitted if the actual document is not available. The actual document shall be furnished to the FCC when it becomes available.
Alcatel-Lucent Remote Radio Head 2X60W - 850, 1900 MHz | UA08.1 Site Preparation NN-20500-305 Issue 0.7; November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2011 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Use pursuant to applicable agreements Legal notice
Alcatel-Lucent – Proprietary Page 1 of 1
Us Pursuant To Company Instructions
Use pursuant to applicable agreements
Title page
P
RELIMINARY
Alcatel-Lucent
Remote Radio Head 2X60W - 850, 1900 MHz | UA08.1
Site Preparation
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
NN-20500-305
Issue 0.7
November 2011
P
RELIMINARY
Use pursuant to applicable agreements
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2011 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization.
RELIMINARY
Not to be used or disclosed except in accordance with applicable agreements.
P
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
2 2Safety statements
Overview
Purpose
This chapter covers safety precautions.
Contents
P
RELIMINARY
Structure of safety statements 2-2
Safety 2-4
Safety - specific hazards 2-5
Product safety 2-8
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W NN-20500-305 UA08.1 Issue 0.7 November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
2-1
P
RELIMINARY
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
Structure of safety statements
Overview
Safety statements describe the safety risks relevant while performing tasks on
RELIMINARY
P
General structure
Alcatel-Lucent products during deployment and/or use. Failure to avoid the hazards may have serious consequences.
Safety statements include the following structural elements:
BC D
CAUTION
Lifting hazard
Lifting this equipment by yourself can result in injury due to the size and weight of the equipment.
Always use three people or a lifting device to transport and position this equipment. [ABC123]
SAMPLE
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
E
(optional)
injury
(optional)
F G H
Signal words
The signal words identify the hazard severity levels as follows:
Signal word Meaning
DANGER Indicates an extremely hazardous situation which, if not avoided, will
result in death or serious injury.
....................................................................................................................................................................................................................................
2-2
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
Signal word Meaning
WARNING Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE Indicates a hazardous situation not related to personal injury.
P
RELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W NN-20500-305 UA08.1 Issue 0.7 November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
2-3
P
RELIMINARY
Safety statements Safety
....................................................................................................................................................................................................................................
Safety
General precautions for installation procedures
RELIMINARY
P
WARNING
Failure to observe these safety precautions may result in personal injury or damage to equipment.
Read and understand all instructions.
Follow all warnings and instructions marked on this product.
Installation and maintenance procedures must be followed and performed by
trained personnel only.
The equipment must be provided with a readily accessible disconnect device as part of site preparation.
Grounding and circuit continuity is vital for safe operation of the equipment. Never operate the equipment with grounding/bonding conductor disconnected.
Install only equipment identified in the product's installation manual. Use of other equipment may result in an improper connection which could lead to fire or injury.
Use caution when installing or modifying telecommunications lines.
The product has multiple power inputs. Before servicing, Disconnect all
inputs to reduce the risk of energy hazards.
For continued protection against risk of fire, all fuses used in this product must be replaced only with fuses of the same type and rating.
Never install telecommunications wiring during a lightning storm.
Never install telecommunications connections in wet locations.
Never touch uninsulated wiring or terminals carrying direct current or
ringing current, and never leave this wiring exposed. Protect and tape uninsulated wiring and terminals to avoid risk of fire, electrical shock, and injury to personnel.
Never spill liquids of any kind on the product.
To reduce the risk of an electrical shock, do not disassemble the product.
Opening and removing covers and/or circuit boards may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electrical shock when the unit is subsequently used.
....................................................................................................................................................................................................................................
2-4
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011
Safety statements Safety - specific hazards
....................................................................................................................................................................................................................................
Safety - specific hazards
DANGER
Electric-shock hazard
Working in severe weather can result in personal injury or death and damage to the equipment.
Never install or perform maintenance during severe weather (high winds, lightning, blizzards, hurricane etc.).
DANGER
Noxious-substance hazard
Use of unspecified cleaning agents can result in personal injury.
Use only specified cleaning agents. Never use flammable solvents.
P
RELIMINARY
Always ensure there is adequate ventilation in the work area and wear the appropriate personal protective equipment.
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the optical source is switched on. Always observe the laser warning instructions.
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to observe this fact and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in IEC 60215 + A1 or EN 60215) may install or service the installation.
WARNING
Electric-shock hazard
The power supply lines to the network element are energized. Contact with parts carrying voltage can cause health problems, possibly including death, even hours after the event.
Open and lockout the load disconnect switch in the distribution box to completely de-energize the network element.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W NN-20500-305 UA08.1 Issue 0.7 November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
2-5
P
RELIMINARY
Safety statements Safety - specific hazards
....................................................................................................................................................................................................................................
WARNING
Laser hazard
The light from laser and high-radiance LED's may cause eye damage if absorbed by the
RELIMINARY
P
retina.
In the US consult ANSI Z136.2, in Europe consult IEC-60825 Safety of laser products, for guidance on the safe use of optical fiber communication systems in the workplace.
NOTICE
ESD hazard
Semiconductor devices can be damaged by electrostatic discharges.
The following rules must be complied with when handling any module containing semiconductor components:
Wear conductive or antistatic working clothes (for example, coat made of 100% cotton).
Wear the grounded wrist strap.
Wear shoes with conductive soles on a conductive floor surface or conductive work
mat.
Leave the modules in their original packaging until ready for use.
Make sure there is no difference in potential between yourself, the workplace, and the
packaging before removing, unpacking, or packing a module.
Hold the module only by the grip without touching the connection pins, tracks, or components.
Place modules removed from the equipment on a conductive surface.
Test or handle the module only with grounded tools on grounded equipment.
Handle defective modules exactly like new ones to avoid causing further damage.
NOTICE
Condensation
Sudden changes in the weather may lead to the formation of condensation on components. Operating the unit when condensation moisture is present can destroy the unit.
Units which show signs of condensation must be dried before installation.
....................................................................................................................................................................................................................................
2-6
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011
Safety statements Safety - specific hazards
....................................................................................................................................................................................................................................
CAUTION
Laceration hazard
The cabinet and the components within may have sharp edges and burrs and contact may cause cuts and lacerations.
Beware of sharp edges and burrs, especially when working on areas inside the cabinet difficult to access.
Wear appropriate personal protective equipment.
NOTICE
Tools
Tools left in the working area can cause short circuits during operation which can lead to the destruction of units.
Make sure after finishing your work that no tools, testing equipment, flashlights, etc., have been left in or on the equipment.
P
RELIMINARY
NOTICE
Corrosive-substance hazard
Cleaning plastic containers and lids with abrasive and aggressive cleaning agents may cause permanent damage.
Do not use solvents, paraffin, abrasive or aggressive cleaning fluids, abrasive or aggressive antiseptic agents or abrasive or aggressive materials.
NOTICE
Service-disruption hazard
Cleaning with water or a high-pressure cleaner will damage the components in the cabinet.
The washing down of the equipment or cabinet with water or a high-pressure cleaner is not permitted.
CAUTION
Lifting hazard
Lifting this equipment by yourself can result in injury due to the size and weight of the equipment.
Always use at least two people or a lifting device to move or position this equipment.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W NN-20500-305 UA08.1 Issue 0.7 November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
2-7
P
RELIMINARY
Safety statements Product safety
....................................................................................................................................................................................................................................
Product safety
Equipment safety
Safety information for this equipment can be found on various Caution, Warning, Danger,
RELIMINARY
P
information labels or instructions affixed to or included with the enclosure, its internal assemblies or included within this document. Informational and cautionary labels may appear near the item they address or may be grouped in a single location on the equipment. Warnings are typically adjacent to the hazard that is noted on the label. The instructions, cautions and warnings found on these labels must be understood and observed by all personnel involved with the equipment installation and maintenance.
....................................................................................................................................................................................................................................
2-8
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011
3 3Product overview
Overview
Purpose
.
This chapter provides an overview of the Alcatel-Lucent Remote Radio Heads:
P
RELIMINARY
Contents
RRH 2X60-850
RRH 2X60-1900
Functional description 3-2
Physical description 3-4
Equipment 3-12
Mounting locations 3-13
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W NN-20500-305 UA08.1 Issue 0.7 November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
3-1
P
RELIMINARY
Product overview Functional description
....................................................................................................................................................................................................................................
Functional description
General description
The Alcatel-Lucent Remote Radio Head 2X60W product is the latest generation of
RELIMINARY
P
Product configurations
Product capabilities
UMTS cell site equipment.
The standard configuration offers:
For the 9396 d2U a maximum of three sectors per Base Band Unit (BBU)
For the 9326 / 9926 d2U a maximum of six sectors per Base Band Unit (BBU)
The product capabilities in this release are:
DC power supply variant: – 48V (– 40V to – 57V)
RF output power @ antenna port : 2X60W (47.8dBm) at antenna connector, shared
across transmitted carriers.
Operating radio frequency:
850 MHz for the RRH 2X60-850
Band V, 3GPP TS25.104
1900 MHz for the RRH 2X60-1900
Band II, 3GPP TS25.104
Number of carriers: up to four adjacent carriers (20 MHz) per antenna
One sector
2 antennae
4 antennae (future release)
Daisy chaining for RRHs operating in single carrier mode
User alarms
External user alarms
RRH 2X60-850 RRH 2X60-1900
66
Mounting standard configuration:
Pole
Wall
Floorstand
Front access installation and service
Bottom I/O panel access
Single or twin Antenna Line Device (ALD) compliant with AISG V2.0
....................................................................................................................................................................................................................................
3-2
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011
Product overview Functional description
....................................................................................................................................................................................................................................
Rx AIT
CPRI ports/Rates:2/HWready 3,4,5
External view
This is a view of an RRH 2X60W with 2 antenna connections:
P
RELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W NN-20500-305 UA08.1 Issue 0.7 November 2011
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
3-3
P
RELIMINARY
Product overview Physical description
....................................................................................................................................................................................................................................
Physical description
Overview
This topic covers RRH top and bottom descriptions, ancillary and grounding information.
RELIMINARY
P
Cable interfaces
On the RRH bulkhead the following cable interface points are found:
DC power
Fiber optic
User alarms
Antenna Line Device
Local Maintenance Terminal port (LMT)
RF
Ground
The top of the RRH allows access for connecting RF cables.
....................................................................................................................................................................................................................................
3-4
RELIMINARY
P
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W
NN-20500-305 UA08.1
Issue 0.7 November 2011