Nokia INLITERU-01 User Manual

Alarm Descriptions
DN00283923 © Nokia Corporation 1 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Alarm Descriptions
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This document is intended for the use of Nokia Networks' customers only for the purposes of the agreement under which the document is submitted, and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Nokia Networks. The document has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Nokia Networks and the customer. However, Nokia Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Networks will, if necessary, explain issues which may not be covered by the document.
Nokia Networks' liability for any errors in the document is limited to the documentary correction of errors. Nokia Networks WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARY LOSSES), that might arise from the use of this document or the information in it.
This document and the product it describes are considered protected by copyright according to the applicable laws.
NOKIA logo is a registered trademark of Nokia Corporation. Other product names mentioned in this document may be trademarks of their
respective companies, and they are mentioned for identification purposes only.
Copyright © Nokia Corporation 2001. All rights reserved.
0523
Hereby, Nokia Corporation, declares that this Nokia InLite is in compliance with the essential requirements and other relevant provisions of Directive: 1999/5/EC. The product is marked with the CE marking and Notified Body number according to the Directive 1999/5/EC
FCC FCC §15.21 - Information to user - The Nokia InLite is used as an intentional
radiated equipment and any changes or modifications on the equipment without any approval by Nokia could void the user's authority to operate the equipment.
FCC §15.27 b) - Special Accessories - If a device requiring special accessories is installed by or under the supervision of the party marketing the device, it is the responsibility of that party to install the equipment using the special accessories. For equipment requiring professional installation, it is not necessary for the responsible party to market the special accessories with the equipment. However, the need to use the special accessories must be detailed in the instruction manual, and it is the responsibility of the installer to provide and to install the required accessories.
2 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
FCC §15.105 - Information to user - This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
DN00283923 © Nokia Corporation 3 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Alarm Descriptions
History
Date Version Author Details
March 2001 Version 1 Brian Searle 20 - 07 - 2001 Version 2 Draft 1 Tom Dumic Included US Type Approval information 22 - 08 - 2001 Issue 2 Tom Dumic Release for Product v1.0 US 05 - 09 - 2001 Issue 2, Draft 1 Tom Dumic Draft for Product v2
4 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
1 About this document
This document describes the Nokia InLite system alarms. The document provides detailed explanations of the alarms and provides instructions so that the operator can correct faults and maintain traffic in the air interface. All alarms can be monitored via the InLite Supervisor software Version 2.3.2
The document includes:
Detailed alarm instructions for InLite system
Alarm classification (Major on Minor)
Actions to take for each alarm
About this document
DN00283923 © Nokia Corporation 5 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Alarm Descriptions
6 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
2 Nokia InLite system alarms
2.1 Alarm classification
Alarms are classified in two categories that are sent to BTS external alarms.
Major Alarm=>Indicating service effecting failure
Minor Alarm=> Indicating a non-service effecting failure
Nokia InLite system alarms
2.2 Main Unit alarms
2.2.1 Switch matrix unit alarms
Alarm Description
Excess RF input power*
* This feature is NOT available for InLite 1.0 US.
TRX with a RF power higher than the Over Power threshold. The TRX’s indicator is red.
Alarm
Category
Major Yes Reduce the TRX output
Auto
Recovery
Action
power to less than +33 dBm(2W). Note: the nominal TRX port input RF power is +30dBm(1W) maximum
DN00283923 © Nokia Corporation 7 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Table 1. Switch Matrix Unit Alarms
2.2.2 Control Unit alarms
Alarm Descriptions
Alarm Description
CU AL CU alarm for Self Test
Failure: one or more units in the system do not respond to CU queries. Red led is ON.
BkUp PSU or External
Temperature alarm: an alarms backup has been performed and stored in the CU to avoid the loss of data if the system power supply drops. Red led is ON.
System Al All alarms; red led is ON
and alarm is either major or minor.
Table 2. Control Unit alarms
Alarm
Status
Auto
Recovery
Action
Major Yes Remove the faulty unit(s)
and insert known good units; check that the system functions correctly.
Major Yes See PSU alarms
description
- - See Figure Alarm
2.2.3 Local Unit alarm
Alarm Description
UPLINK Alarms Tone_L UL Tone transmitted by RU
below the threshold (Low).
Tone_F UL Tone transmitted by RU
absent (Fail)
General Alarms
Alarm
Status
Auto
Recovery
Action
Minor Yes Clean UL Fiber Optical
cable or replace if if it is damaged or stretched.
Major Yes RU laser broken,
switched off or fibre optic cable broken; check RU or fibre optic cable.
8 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
Nokia InLite system alarms
Alarm Description
RF_UL_F Current of the RF uplink
amplifier out of range
RF_DL_F Current of the RF Downlink
amplifier out of range
DL_LA_F Downlink laser broken or
switched off by the Shut Down command.
SH_AL Board in short-circuit
condition or no power supply to LU
TEM_AL Temperature alarm out of
range:[0...+75](C
Table 3. Local Unit alarms
Alarm
Status
Auto
Recovery
Action
Minor No Remove and fit a known
good unit
Minor No as above
Minor Yes/No Yes: Switch ON LU laser
by Shut Down command No: LU laser broken, remove and fit a known good LU.
Minor No Remove and fit a known
good unit
Minor Yes Wait until the temperature
returns to the normal operating range. Check LU board.
2.2.4 Power Supply Unit alarms
Alarm Description
Pw1_Temp (Master)
Pw2_Temp (Slave)
Pw1_Vout (Master)
Pw2_Vout (Slave)
Pw1_Vin (Master)
Pw2_Vin (Slave)
Power supply temperature critical; System Shut Down. Red led is ON.
Power supply voltage out of range; System Shut Down. Red led is ON.
Mains voltage out of range; System Shut Down. Red led is ON.
Alarm
Status
Auto
Recovery
Action
Major Yes System Shut Down while
temperature over threshold.
Major No Remove the module and
fit a known good one.
Major No Check the mains supply
source
DN00283923 © Nokia Corporation 9 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Table 4. Power Supply Unit alarms
2.2.5 Other alarms
Alarm Descriptions
Alarm Description
Ext_Temp Temperature in the Main
Unit cabinet above the threshold. System Shut Down. Red led is ON.
OpDoor (Open Door)
The cover of Main Unit is open. Red led is ON.
Table 5. Other alarms
2.3 Remote unit alarms
Alarm Description
DC_Loop Antenna connector open
(no load). Max attenuation of the downlink paths of the RU is automatically set.
Alarm
Status
Major Yes System Shut Down while
Minor Yes Close and lock the main
Alarm
Status
Minor Yes Check if antenna is
Auto
Recovery
Auto
Recovery
Action
the temperature value exceeds the threshold.
unit cover.
Action
connected or correct type.
DL_Tone Downlink RF tone below
the threshold.
DL_OptP Downlink Optical Power
below threshold: automatic DL laser shut down of the RU.
AGC Automatic Gain Control: out
of range
DL_900 900 MHz Downlink amplifier
current out of range
10 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
Minor Yes Clean DL fibre optic cable
or fit a new cable if this one is damaged or stretched.
Minor Yes as above.
Minor Yes as above.
Minor No Remove the RU and fit a
known good RU
Nokia InLite system alarms
Alarm Description
DL_1800 1800 MHz Downlink
Alarm
Status
Minor No as above
Auto
Recovery
Action
amplifier current out of range
Ext1 External alarm Minor Yes Depends on what is
connected to the External Alarm
Ext2 External alarm Minor Yes Depends on what is
connected to the External Alarm
Table 6. Remote Unit alarms
DN00283923 © Nokia Corporation 11 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Alarm Descriptions
12 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en
3 Alarm Tree
Alarm Tree
DN00283923 © Nokia Corporation 13 (14) Issue 2 DRAFT 1 - en Nokia Proprietary and Confidential
Major
Excess
RF Input
Power
CUAL
Alarm Descriptions
Pw1_Temp (Master)
Pw2_Temp (Slave)
Pw1_Vout (Master)
System Al
Minor
Bkup
Tone_F
Tone_L
RF_UL_F RF_DL_F
TEM_AL
TEM_AL
DC_Loop
AGC
DL_900
DL_1800
Pw2_Vout (Slave) Pw1_Vin (Master)
Pw2_Vin (Slave)
Ext_Temp
SH_AL
DL_Tone DL_OptP
DL_LA_F
Ext1
Ext2
OpDoor (Open
Door)
SM
CU LU
RU
PSU
HS
NOTE: In case of InLite release 1.0 (U.S) this function is not available
Figure 1. Alarm
14 (14) © Nokia Corporation DN00283923
Nokia Proprietary and Confidential Issue 2 DRAFT 1 - en