Please Visit our Website and complete the Online Registration
www.noirot.com.au
Page 2
RECOMMENDATION FOR WALL INSTALLATION
This heater is sold ready for D.I.Y. installation, with Wall bracket and flexible
cord supplied. To remove the wall bracket from the heater you need to push
down on the spring loaded clips located at the top of the bracket. This can be
done by using your fingers or, if preferred, a screwdriver (No: 1 Fig.1). Fit the
wall bracket to the wall with suitable fixing method according to the surface you
mount the heater on (not included). Place the heater on to the bracket and clip
into position.
Note: To centre your appliance laterally on the wall, use the hole marked 2.
The heater must not be located immediately below a socket outlet (as per
requirement of Clause 7.12 of AS/NZS 60335.2.30).
Fig. 1
WARRANTY REGISTRATION:
IMPORTANT: To validate your product warranty, you are required to do the
following:
1.Register your product online at www.noirot.com.au, click on “Product
Registration” and fill out the required fields.
2.You must also retain your receipt of purchase
WARRANTY CONDITIONS
Your Noirot Spot Plus electric panel heaters comes with a LIFETIME
WARRANTY, therefore any replacement of faulty parts or repairs of any kind
must be carried out by a qualified person and authorised by Noirot Australia Pty
Ltd or their approved representative.Failure to do so will VOID the
WARRANTY.
Noirot Australia Pty. Ltd. reserve the right to reject any warranty claim deemed
to be false. Retailers must have warranty claims authorised by a representative
of Noirot Australia.
If you believe your product to be faulty and under warranty you are required to
do the following:
1.Return the product, at your expense, to the place of purchase for
assessment by an authorised representative of Noirot Australia.
2.Thismay requireleaving the product at the place of purchase.
3.If the product is deemed faulty and under warranty, the place of
purchase of the product will order a replacement heater to which Noirot
Australia, at our cost, will deliver the heater to the place of purchase.
4.The consumer will then be required, at their cost, to pick up the
replacement heater from the place of purchase.
5.If the heater is faulty but not deemed to be under warranty, an
explanation will be provided to the consumer and that the faulty heater
can be picked up by the customer from the place of purchase.
NOIROT AUSTRALIA: 1 300 664 768www.noirot.com.au2
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage. You
are also entitled to have the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a major failure.
If you have any queries regarding your product or its warranty please contact:
Noirot Australia Pty Ltd
TheNoirotElectronic
Thermostat is designed to read
the room temperature every 30
seconds. This offers maximum
economy,greaterefficiency
and is very simple to use.
1.To turn the heater on,
turn dial A from ‘-
Standby’ to ‘On’.
2.Turn dial C until light B
illuminates.
3.Allow time for the room
to heat up. This will vary with the size of the room but usually takes 1520mins. The light B will turn off.
4.To achieve your comfort level simply adjust the dial C to suit. If you
require more heat turn the C dial up to a larger ‘DOT’. If the room is too
hot then turn the dial C to a smaller ‘DOT’.
5.To return the heater to standby, turn dial ‘A’ from ‘On’ to ‘- Standby’
MAINTENANCE
Your Noirot Electric Panel Heater requires very little maintenance. To remove
surface dust use a soft cloth; to remove marks use a damp cloth. Never use
abrasives or metal scourers which could damage the polyester coating. It is
recommended to periodically clean the air vents using the soft brush on your
vacuum cleaner, as dense accumulation of dust will cause the heater to overheat and trigger the safety thermal cut-out switch.
Heater temperature settings will vary from house to house according to the
building type and its level of insulation. They will also vary from room to room,
depending on factors such as room orientation (facing north or south) and
window sizes. Items such as computers and lights (which generate heat) and
people will also affect a room’s temperature.
Running costs are not wholly governed by the temperature setting on the panel
heater. The same maximum power is used to reach 10° or 30°. Where the
energy efficiency and economy is obtained is in the sizing of the heater to the
particular room where it is to be used. If the heater is sized correctly, then the
thermostat will cycle on & off as required to maintain your comfort level, no
matter where on the scale your comfort setting is.
RECOMMENDATION FOR USE WITH CASTORS
This heater is tested and approved for use with the optional “Easy Glide
Castors”. Please follow the fitting instructions closely and be aware that once the
BLACK CLIPS are fixed into position, the castors CANNOT be removed without
breaking them.
WARNING:
Do not use the heater on the floor without the “Easy Glide Castors”. Also, when
using as a portable heater do not use in the immediate vicinity of a bath, shower
or swimming pool.
NOIROT AUSTRALIA: 1 300 664 768www.noirot.com.au6
NOIROT AUSTRALIA: 1 300 664 768www.noirot.com.au3
Page 4
PANEL LOCATIONS
This heater is suitable for use in all rooms including Zone 2 in Bathrooms (Fig.2)
in accordance with AS/NZS 3000: 2000 (Wiring Rules). Although this heater is
double insulated and does not require earthing, it must be located so that the
controls cannot be touched by a person in the bath or shower.
Fig. 2
For maximum efficiency, this heater
should be wall mounted at a minimum
height of 150mm off the floor. This is
to allow the necessary volume of air to
flow freely through the vents. It is also
important to allow a minimum of
100mm clearance at the top and sides
of the heater and 500mm from the
front (Fig. 3) so as not to force the air
back into the heater and activate the
Over Temperature Safety Thermal
Cut-Out Switch.
WARNING: Inordertoavoid
overheating, DONOT
cover the heater
NOIROT AUSTRALIA: 1 300 664 768www.noirot.com.au4
Fig. 3
ELECTRICAL CONNECTION
This heater is fitted with an Australian Approved Flexible Cord and Plug. For
wall-mounted installations connection can be either by plugging into an existing
10 amp power point (DIY) or direct wired by a Licensed Registered Electrical
Contractor, who is required to issue a Certificate of Electrical Safety.
PLEASE NOTE:
For safety reasons the Flexible Cord must not be modified or repaired in any
way. If the Cord is damaged, it must be replaced by a Noirot appointed and
approved service agent. If there are any concerns, contact Noirot Australia Pty
Ltd on 1 300 664 768 before plugging it in.
IMPORTANT:
Do not plug in to a Power Board, Double Adaptor or Extension Lead.
IMPORTANT: DO NOT COVER THE HEATER
Avoid blocking air flow to and from the heater with clothing, open doors, furniture
and small toys or paper inserted into the louvres. This will cause the heater to
over-heat and activate the safety thermal cut-out switch.
If the “Over Temperature Safety Thermal Cut-Out Switch” is activated, the
heater will automatically switch off to limit the temperature to a safe value. To
reset the thermal cut-out, simply switch the heater off, unplug it from the power
point and remove the obstruction(s). Plug the heater back in and switch it on.
The thermal cut-out switch will reset after a few minutes and the heater will
function normally.
USING YOUR HEATER FOR THE FIRST TIME
Remove the heater from its packaging (please dispose of packaging
responsibly). Contents should be as follows:
1. Heater
2. Wall bracket (pre-attached to the back of the heater).
3. Instructions for installation and use (8 page booklet).
Ensure the heater is correctly mounted on the wall or fitted to the castors prior to
turning it on. Remove the white plastic protective covers from the plug pins and
insert the plug into the wall socket.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
NOTE:
When the heater is turned on for the first time, or after it has been off for a long
period, such as during the summer months, you may experience a slight burning
smell. This is quite common and should disappear after a few minutes. If it
should persist, switch the heater off and have it inspected.
NOIROT AUSTRALIA: 1 300 664 768www.noirot.com.au5