In order to put your Soft Remote into “Gateway” Mode, you just have to add the Soft
Remote into the gateway’s Z-Wave® network. Procedure as following:
1 Place your home automation gateway into “Inclusion” Mode. To do so, please
refer to your gateway’s user guide.
2 Simultaneously push on I and P, during 1sec.
The LED glows in pink to conrm the selection
3 Push on I, within 10 seconds.
The LED blinks in pink to conrm your choice
The LED blinks in green to conrm the procedure
Warning : If your Soft Remote added some devices in “Standalone” Mode, these devices will remain
orphans. Make sure you remove (or reset) all devices previously added or associated into the Soft
Remote’s network, before placing the Soft Remote in “Gateway” Mode.
If your home automation gateway supports the “ Controller shift” feature, you can
recover the existing Soft Remote’s network (while it is in “Standalone” Mode) when
you pass into “Gateway” Mode.
Your home automation gateway will be added into the Soft Remote’s network, and
set as the main controller. All the information related to the added devices will
be automatically copied to the home automation gateway during this process.
However, all existing association between the Soft Remote and devices will be lost,
and would need to be set-up again, using your home automation gateway interface.
The existing network of the gateway will be lost as well.
The procedure is as following:
1 Place your home automation gateway into “Learning” Mode. To do so, please
refer to your gateway’s user guide.
2 Simultaneously push on I and P, during 1sec.
The LED glows in pink to conrm the selection
3 Push on P, within 10 seconds.
The LED blinks in pink to conrm your choice
The LED blinks in green to conrm the procedure
REMOVE THE Soft Remote FROM THE NETWORK
In order to remove the Soft Remote from the gateway’s Z-Wave® network:
1 Place your gateway into “Exclusion” Mode. To do so, please refer to your
gateway’s user guide.
2 Simultaneously push on I and P, during 1sec.
The LED glows in pink to conrm the selection
3 Push on I, within 10 seconds.
The LED blinks in pink to conrm your choice
The LED blinks in green to conrm the procedure
Expert Note: It is possible to send just a single NIF by following this procedure:
1 Simultaneously push on I and P, during 1sec
The LED glows in pink to conrm the selection
2 Push on O, within 10 seconds
The LED blinks in pink to conrm your choice
“GATEWAY MODE” FEATURES
Warning : Make sure your gateway supports all the features of the Soft Remote (compatible gateways
are listed on www.nodon.fr/en ).
INCLUSION ON BEHALF OF THE GATEWAY
1 Push 3 times (quickly) on the I button.
The LED blinks in blue
2 Place the device you want to add in “Learning” Mode, within 10 seconds. To do so,
please refer to your device’s user guide.
The LED blinks in green to conrm the inclusion
EXCLUSION ON BEHALF OF THE GATEWAY
1 Push 3 times (quickly) on the M button.
The LED blinks in blue
2 Place the device you want to remove in “Learning” Mode, within 10 seconds. To
do so, please refer to your device’s user guide.
The LED blinks in green to conrm the exclusion
ASSOCIATION GROUPS
Once set-up through the gateway, association groups allow direct communication
between the Soft Remote and the Z-Wave® devices you want to control, without
involving the gateway in the communication.
BUTTON 2 CONFIGURATION
Parameter Number Default Value Size
5 0 1 [byte]
To set-up the how button 2 behaves, when set in MONO Prole
Value Description
0 Control Group 3
1 All Switch ON
2 All Switch OFF
BUTTON 3 CONFIGURATION
Parameter Number Default Value Size
6 0 1 [byte]
To set-up the how button 3 behaves, when set in MONO Prole
Value Description
0 Control Group 4
1 All Switch ON
2 All Switch OFF
BUTTON 4 CONFIGURATION
Parameter Number Default Value Size
7 0 1 [byte]
To set-up the how button 4 behaves, when set in MONO Prole
Value Description
0 Control Group 5
1 All Switch ON
2 All Switch OFF
When the selected prole is « SCENE » (default value), the Soft Remote
communicates only with the home automation gateway. The user interface of your
gateway will then allow you to set-up scenes based on which (and which way) you
press the different buttons. To do so, please refer to your gateway’s user guide.
The different actions that can be handled by the Soft Remote are:
• Simple press (on I, O, P or M)
• Double press (on I, O, P or M)
• Long press (on I, O, P or M)
• Button released (on I, O, P or M)
Which makes a total of 16 different actions.
It is strongly advised to use this prole if supported by your gateway.
However, if your home automation gateway does not support these features, you
can still use association groups and set-up your buttons as
• MONO Prole, to control the corresponding group or activate the
Z-Wave® « All Switch ON » or « All Switch OFF » features.
• DUO Prole, to control the corresponding groups.
LED MANAGEMENT
Parameter Number Default Value Size
8 0 1 [byte]
How to set up LED behaviour
Value Description
0 No LED
1 Flash Blue after button press
2 Blinking to conrm command
3 Both options above (1&2)
Warning : In order that the Soft Remote takes into account the update of association groups and/
or conguration parameters just modied through your home automation gateway, it is necessary
to wake it up. To do so, press on any button of the Soft Remote. The new associations and/or
conguration parameters will be then effective.
COMMAND CLASS
The Soft Remote supports the following Command Class:
COMMAND CLASS VERSION
All switch* V1
Application status* V1
Association V2
Association Group Information V1
Basic* V1
Battery V1
Central Scene** V2
Conguration V1
Device Reset Locally V1
Manufacturer Specic V2
Multilevel Switch* V3
Power Level V1
Scene Activation* V1
Version V2
Wake-Up** V2
Z-Wave
®
Plus info** V2
* Controlled only (not supported)
** Controlled AND supported
LOGOTYPE
This product (CRC-3-6) is compliant with all relevant European
standards.
This product (CRC-3US-6) is compliant with FCC regulation.
This product (CRC-3US-6) is compliant with IC regulation.
When sorting your waste, please observe the disposal regulations in
force. Please place your waste in the facilities provided for that purpose
and with all due respect for the environment.
This product must be used indoor only.
This product is compatible with Z-Wave® and Z-Wave Plus®
protocol.
CONTACT
Manufacturer & Importer ::
ID-RF SAS
121 rue des Hêtres
45590 St CYR EN VAL (FRANCE)
AFTER SALES
www.nodon.fr section “support”
contact@nodon.fr
For user guides in other languages, please visit
www.nodon.fr/notices
The Soft Remote has 7 associations groups:
Group Group Name
1 Lifeline
2 Button 1 - Mono - Controlled nodes
3 Button 2 - Mono - Controlled nodes
4 Button 3 - Mono - Controlled nodes
5 Button 4 - Mono - Controlled nodes
6 Button 1&3 - Duo - Controlled nodes
7 Button 2&4 - Duo - Controlled nodes
Group 1 – Lifeline
Maximum number of devices in group: 1
This group is dedicated for the home automation gateway.
Group 2/3/4/5
Maximum number of devices in group: 8
Devices associated in these groups are controlled by the corresponding button,
according to MONO Prole (in the exact same way as « Standalone » Mode).
Group 6/7
Maximum number of devices in group: 8
Devices associated in these groups are controlled by the corresponding buttons,
according to DUO Prole (in the exact same way as « Standalone » Mode).
CONFIGURATION PARAMETERS
Buttons’ prole (MONO/DUO/SCENE), in « Gateway » Mode, are set-up through
several conguration parameters.
BUTTONS 1&3 PROFILE
Parameter Number Default Value Size
1 0 1 [byte]
To set-up the prole of buttons 1 & 3
Value Description
0 SCENE
1 MONO
2 DUO
BUTTONS 2&4 PROFILE
Parameter Number Default Value Size
2 0 1 [byte]
To set-up the prole of buttons 2 & 4
Value Description
0 SCENE
1 MONO
2 DUO
SCENE TYPE
Parameter Number Default Value Size
3 0 1 [byte]
To choose the way of sending Scene to the gateway
Value Description
0 CENTRAL SCENE
1 SCENE ACTIVATION
We strongly advise you to use « CENTRAL SCENE », which is more user-friendly.
However, some home automation gateways don’t support « CENTRAL SCENE » yet,
then you can still use the previous standard « SCENE ACTIVATION ».
The user interface of your gateway will then allow you to set-up scenes.
BUTTON 1 CONFIGURATION
Parameter Number Default Value Size
4 0 1 [byte]
To set-up the how button 1 behaves, when set in MONO Prole
Value Description
0 Control Group 2
1 All Switch ON
2 All Switch OFF