nodon ASP-3-1-00, ASP-3-1-10 User Manual

The NodOn® Smart Plug allows to control (Power ON or Power OFF) an electrical appliance plugged on it: bedside lamp, electrical heater, coffee machine, etc.
The NodOn
®
Smart Plug is compatible with the worldwide home
automation standard, Z-Wave
®
, and all the products Z-Wave® or
Z-Wave Plus
®
certied.
INSTALLATION
Thanks to an innovative design, the Smart Plug can be mounted on the power outlet in either side, head up or head down.
1 Plug the NodOn
®
Smart Plug on your power outlet.
2 Plug the electrical appliance, you want to control, on the NodOn
®
Smart Plug.
3 The Smart Plug allows to switch ON (Power ON) or switch OFF
(Power OFF) the electrical appliance you want to control. Switching ON or OFF can be done through the Smart Plug local
button, or any kind of Z-Wave
®
compatible devices, such as the
NodOn
®
Octan Remote, the NodOn® Soft Remote or a Home
Automation Gateway.
If the electrical appliance (ex.: bedside lamp) has an ON/OFF button, make sure it’s positioned on “ON”, in order that the power ON of the appliance by the Smart Plug will switch ON the lamp.
SMART PLUG MODES
LOCAL CONTROL
The Smart Plug can be switched ON or OFF locally, through a short press on the local button. By default, the Smart Plug is switched ON when the LED is green, OFF when the LED is OFF.
LEARNING MODE
Press on the Smart Plug button during 2 seconds until the LED becomes red. Release the button, the LED will then glow in red. The Smart Plug is in “Learning mode”.
To add or to remove the Smart Plug from a Z-Wave
®
network,
follow “INCLUSION” or “EXCLUSION” procedures below.
If the Smart Plug is not added or removed from a network within 30 seconds (or if the button is pushed during learning mode), the
ON
OFF
<1sec
<1sec
2 sec
{Blinking}
Smart Plug will automatically exit learning mode.
Expert remark: NodOn® created a power ecient « Learning mode ». During this mode, the
Smart Plug will send its « Node Information » (NIF) at regular interval.
If the Primary Controller is battery powered (such as the NodOn
®
Octan Remote), rst put the
Smart Plug in « Learning mode », and then proceed to the INCLUSION/EXCLUSION procedure
of your controller. To send a single NIF, just triple press on the Smart Plug’s button.
LED state Smart Plug State
Shine Red Learning mode activated
Blink in Green Successful Inclusion
Blink in Red Successful Exclusion
Blink in Orange “Learning mode” Timeout
FACTORY RESET
To perform a factory reset, press on the Smart Plug button during 5 seconds until the LED becomes orange. Release the button, the LED will blink red/green.
Factory Reset clears the Smart Plug’s memory and set parameters to default value.
WARNING
Please use this procedure only when the primary controller is missing or otherwise inoperable. Resetting the Smart Plug does not mean it has been removed from Z-Wave
®
network
controller’s memory. Use the primary controller to remove the Smart Plug from its Z-Wave
®
network (follow
“EXCLUSION” procedures below), before doing a Factory Reset.
INCLUSION PROCEDURE
To add the Smart Plug into a Z-Wave® network
1 Plug the Smart Plug. 2 Put the Smart Plug in “Learning mode”. 3 Within 30 seconds put the Z-Wave
®
Controller in “Learning mode” (See the Controller user guide for its own Inclusion procedure).
4 The Smart Plug will conrm the Inclusion procedure by blinking
its LED in Green.
EXCLUSION PROCEDURE
To remove the Smart Plug from a Z-Wave® network
1 Make sure the Smart Plug is plugged. 2 Put the Smart Plug in “Learning mode”. 3 Within 30 seconds put the Z-Wave
®
Controller in “Learning mode” (See the Controller user guide for its own Exclusion procedure).
4 The Smart Plug will conrm the Exclusion procedure by blinking
its LED in Red.
POWER FAILURE
The Smart Plug embeds a very small energy backup, which allows
it to send Notication Report on a Z-Wave
®
network during a short
time, after a main power failure. The Smart plug must be plugged at least 5 minutes before being
able to detect each Power Failure.
ASSOCIATION GROUPS
Using Association group, the Smart Plug is able to command or notify another device of a Z-Wave
®
network.
The Association groups are set by the Main Controller. Once set, the association groups allow direct control, without involving the Main Controller in the communication.
{Blinking}>5sec
The NodOn® Smart Plug proposes 8 association groups:
Group number Group Name
1 Lifeline 2 Follow State 3 Follow Complementary State 4 Power Failure Notication 5 Power Failure – Set On 6 Power Failure – Set Off 7 Power Recover – Set On 8 Power Recover – Set Off
Group 1 – Lifeline
Maximum number of devices in group: 5
This group is generally used to report information of the Smart Plug to the Main Controller of the network.
Group 2 – Follow State
Maximum number of devices in group: 5
When the Smart Plug is switched ON (respectively OFF) - either locally or by wireless - it will send ON (respectively OFF) command to the associated devices.
Group 3 – Follow Complementary State
Maximum number of devices in group: 5
When the Smart Plug is switched ON (respectively OFF) - either locally or by wireless - it will send OFF (respectively ON) command to the associated devices.
Group 4 – Power Failure Notication
Maximum number of devices in group: 5
When the Smart Plug detects a power failure or recovers from a
power failure, it sends the notication report to the associated
devices.
The sent Notication is “Notication Report: Power Management
– AC Disconnected / Re-connected”
Group 5 – Power Failure Set ON
Maximum number of devices in group: 5
When the Smart Plug detects a Power Failure, it will switched ON the associated devices.
Group 6 – Power Failure Set OFF
Maximum number of devices in group: 5
When the Smart Plug detects a Power Failure, it will switched OFF the associated devices.
Group 7 – Power Recover Set ON
Maximum number of devices in group: 5
When the Smart Plug detects a Power Recover, it will switched ON the associated devices.
Group 8 – Power Recover Set OFF
Maximum number of devices in group: 5
When the Smart Plug detects a Power Recover, it will switched OFF the associated devices.
Power supply: 230V AC +/-10% - 50Hz
Self-consumption <1W
Max. power: - 3000W continuous (Resistive load)
- 3500W temporary (Resistive load) Center radio frequency : 868.42 MHz
Occupied frequency band : 868.40 to 869.85 MHz
RF power Max : +4dBm
Range up to 80 meters outdoor
Range up to 40 meters indoor
Operational temperature: -10°C / 50°C
IP20
Radio protocol: Z-Wave Plus
®
(500 series)
Dimensions: 51mm (W) x 36mm (D) x 104mm (H)
Weight: 137g
Warranty: 2 years
USER GUIDE
SMART PLUG
Smart Plug Type E
Reference: ASP-3-1-00
Smart Plug Schuko
Reference: ASP-3-1-10
CONFIGURATION
The Smart Plug offers a wide range of conguration, which can be
set and handled by the Z-Wave
®
network Main Controller.
Default State
Parameter Number Default Value Size
1 2 1 [byte]
This parameter denes the status of the Smart Plug after a Power Failure or
after being plugged.
Value Description
0 OFF 1 ON 2 Status before Power Failure
Power Failure
Parameter Number Default Value Size
2 0 1 [byte]
This parameter is to set-up the Power Failure / Recover notication and the
associated group (Groups 4, 5, 6, 7, 8).
Value Description
0 Power Failure detection disable 1 Power Failure enable (report to Lifeline only) 2 Enable group 4 4 Enable group 5
8 Enable group 6 16 Enable group 7 32 Enable group 8
The value may be the sum of available values.
For example, if you want to activate Power Failure and enable
group 4 & 5, the parameter value is 1+2+4=7.
Follow State
Parameter Number Default Value Size
3 3 1 [byte]
This parameter allows to enable or disable Group 2 & Group 3.
Value Description
0 Group 2 & Group 3 disable
1 Group 2 enable
2 Group 3 enable
The value may be the sum of available values.
For example, if you want to enable Group 2 & 3, the parameter
value is 1+2=3.
Always On
Parameter Number Default Value Size
4 0 1 [byte]
This parameter forces the Smart Plug status to be ON. While enable it is not
possible to switch OFF the plug (local or wireless).
Value Description
0 Always ON disable
1 Always ON enable
WARNING!
Unplug the product only when it is powered OFF.
Do not plug the products one behind the other.
Do not use the product in a humid area.
The product must be easy to access once plugged.
PICTOGRAM
This product is compliant with all relevant European standards.
When sorting your waste, please observe the disposal regulations in force. Please place your waste in the facilities provided for that purpose and with all due respect for the environment.
This product must be used indoor only.
This product uses a wireless communication protocol.
This product does not contain any battery, and has a low power consumption.
This product must not be in contact with water.
This product must not be exposed to a temperature higher than 50°C.
This product must not be exposed to any kind of re
or heat source.
This product must not be exposed to a temperature lower than -10°C.
This product is compliant with EnOcean
®
radio
protocol.
CONTACT
Manufacturer and Importer:
NodOn
®
by ID-RF:
ID-RF SAS
121 rue des Hêtres
45590 St CYR EN VAL (FRANCE)
AFTER SALES
www.nodon.fr section “support”
contact@nodon.fr
For user guides in other languages, please visit
www.nodon.fr/notices
ALARM
The NodOn® Smart Plug embeds Smart Alarm management
features, in order to react to different kinds of Notications and Events (According to “Notication V1” command class)
Up to 8 Alarms can be congured, through Conguration
parameters #5 to #20.
For each Alarm, the set-up is done through 2 conguration
parameters, as below:
Alarm Number Alarm Type Cong.
Parameter
Alarm Specications
Cong. Parameter
1 5 6 2 7 8 3 9 10 4 11 12 5 13 14 6 15 16 7 17 18 8 19 20
Parameter # Default Value Size
5/7/9/11/13/15/17/19 0 2 [byte]
This parameter is to set the Alarm X Type
Value Description
Use the Home Automation Gateway interface or our Alarm set-up form to
dene the value corresponding to your need*.
Parameter # Default Value Size
6/8/10/12/14/16/18/20 0 4 [byte]
This parameter is to set the Alarm X Specications.
Value Description
Use the Home Automation Gateway interface or our Alarm set-up form to
dene the value corresponding to your need*.
*In order to congure properly each alarm, please use your Home
Automation Gateway interface or our online form at :
www.nodon.fr/support/asp3/alarm
COMMAND CLASS
The NodOn® Smart Plug supports the following Command Class :
COMMAND CLASS VERSION
All switch V1 Application status** V1 Association V2 Association Group Information V1 Basic*** V1 Binary Switch V1 Conguration V1 Device Reset Locally V1 Indicator V2
Manufacturer Specic V2 Notication V4
Power Level V1 Protection V2 Version V2 Z-Wave
®
Plus info V2
** Controlled only (not supported)
*** Controlled AND supported