NOBOCOOL E4E GB 2000, E4E GB 1500, E4E GB 1250, E4E GB 1000, E4E GB 750 Operation Manual

...
NOBO PANEL RADIATORS
SERIES '14' TYPE 'E4E GB' PANEL RADIATORS
o
Six sizes 500 to 2000 watt
o
Electronic Thermostatic control
o
Adjustable scale 5 - 30°C.
o
On - Off switch
o
o
White paint finish RAL 9010
o
Classified IP 24
o
Flex connection 1.9m (RH side)
o
Electronic proportional temperature regulation
o
Variety of Plug-In Control options: Series 8 'R80' plug & play technology.
Wall Bracket fixing centres
L A 200 B 300 C 400 D 600 E 1000
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 14 - E4E GB - Dims. txt - 1403
E4E GB 2000
E4E GB 1500
E4E GB 1250 E4E GB 1000
E4E GB 750 E4E GB 500
1125
975
152
5
475
62
5
775
400
110
62
B
C
D
200
L
70
D
100
Min. Clearance
70
Min. Clearance
NOBO CABLE CONTROL
CONTROL MODULE type R80 ZDC designed for use with NOBO Panel heaters using Series 8 controls.
A Control module with adjustable economy & comfort settings, suitable for dual temperature applications. supplied with pilot wire for switching between temperature modes.
KEY to Fig. 1.
1 – Comfort temperature adjustment control. 2 – Economy temperature adjustment control. 4 – Red Comfort mode indicator light. 5 – Green Economy mode indicator light. 6 – Amber operating indicator light. 8 – On / Off switch. l = On, 0 = Off.
OPERATING INSTRUCTIONS
Switch the heater on with switch (8). Set required temperatures with control (1&2). Activate remote control device.
The action of the electronic thermostat provides proportional regulation of temperature. The Amber operating indicator light will be seen to go on and off at frequent intervals as it adjusts the amount of heat supplied to maintain room temperature. When room temperature is more than 1°C below the thermostat set point the heater will operate continuously but during the last one degree the operation will be proportionally reduced until the required temperature is achieved.
When the red indicator (4) is visible the heater will operate in comfort mode and maintain the higher temperature setting (4). When the remote control device is activated the mode of operation is changed from comfort mode to economy mode. The red indicator will go out and the green indicator (5) will come on, the heater then will operate in economy mode and maintain the lower setting (2).
SCHEMATIC WIRING DIAGRAM
'OPTO'
PANEL RADIATOR
E N L L
230 volt 230 volt
When the control circuit is off the heater will operate in comfort mode. POWER SUPPLY CONTROL CIRCUIT When the control circuit is energised the heater will operate at the lower setting.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 8 - ZDC. txt - 240
A
ZDC
Temperature control module. 240
SP CO
NOBO CABLE CONTROL
Power: 230 - 240 volts AC Contacts: 3 amps at 240 volts Enclosure: Double Insulated - IP30 Dimensions:
101 x 163 x 33
mm
Mounting: Wall surface mounted Battery: 10 months Switch: 3 on and 3 off per day Override: 1 or 2 hours boost
Heating 2 Zone 7 day Time Control Unit.
Designed to provide time control for two heating zones using a pilot wire sytem of control.
SCHEMATIC WIRING DIAGRAM
Each heater requires both permanent power supply and live pilot wire circuits All wiring must comply with IEE Regulations. Observance of clause 514-11-01 of the wiring regulations in necessary where more than one live supply is taken into an appliance. At each heater position use of a Triple Pole Isolator or two Double Pole isolators is recommended.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
13 H27Z. txt - 2ZC.02
H27Z
Loading...