NMS Communications PA Hyper-T3 DS3 User Manual

REGULATORY NOTICES
UNITED STATES
Federal Communications Commission (FCC)
FCC Part 15 Rules, Subpart B § 15.105 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against h armful i nterferen ce when t he equi pment is opera ted in a commer cial envi ronment . This equipment generates , use s , and can radiate r adio frequency ene r g y and, if not installed and use d in accordance with the instruction manual, may cause harmful inter f e r e nce to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user wi ll be required to correct the interference at its own expense.
CANADA
Industry Canada ICES-003 Issue 2:
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de Classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
EUROPE
CE Compliance
The PA Hyper-T3 platform meets the following European Directives:
89/336/EEC EMC Directive 73/23/EEC Low Voltage Directive
To achieve CE compliance, be sure to select a host that already meets the EMC and Low Voltage Directives before the addition of any optional board.
SAFETY REQUIREMENTS
UL/C-UL Listed Certifications
The PA Hyper-T3 platform is certified to meet Information Technology Equipment safety standards UL 1950 3rd edition, CSA 22.2, No 950.
PA Hyper-T3 DS3
QUICK INSTALL
Static electricity can damage sensitive electronic components.
Discharge your body’s static electric charge by touching a grounded surface e.g., the metal area of the computer chassis before performing any hardware procedure.
The manufacturer assumes no liability for any damage caused directly or indirectly, by improper installation of any components by unauthorized service personnel. If you do not feel comfortable performing the installation, consult a qualified computer technician.
PACKAGE CONTENT
 PA Hyper-T3 DS3/T1 resource adapter with onboard CPU  Rear Access I/O Adapter for rear access connection  Quick Installation This document
DOCUMENTATION
The User’s Guide a nd the API Guide documentation are available on our website:
http://www.nmss.com/support/nms_support.nsf
(Product Manuals)
Natural MicroSystems - NNA
4200, La Périère, St-Hubert, Qc, Canada, J3Y 9G3 Tel. (450) 676-2977 Fax (450) 676-0360 http://www.nmss.com
9000-00063-01c
Copyright © IML 2000
Picture does not exactly represent final product
INSTALLATION
HARDWARE
Before you proceed with the installation of the board, make sure that the backplane technology matches with the board technology (power supply, busses, etc ...).
CompactPCI headers located on the backplane are fragile Ensure that the board is properly inserted into the board guide and connectors are aligned with its related slot. If there is any resistance, do not use force to engage the board
Installation: When the system is up and running, it is important to install the Rear Access I/O Module first then complete with the installation of the Front Module.
Removal: When the system is up and running, it is important to remove the Front Module first then complete with the removal of the Rear Access I/O Module.
Caution: The Rear Access I/O Module must not be installed or removed as long as Front Module is present in the system.
For complete information on hardware installation, refer to the User’s Guide.
SOFTWARE
For complete information on software inst allation, refer to the User’s Guide.
KNOWS BUGS
None at this time.
MAKING CONNECTIONS
DS3 CONNECTION
The physical media consists of tw o 75- o hm co ax ial cable links (with RJ-59 BN C co nnectors), one for each direction of transmission. Insertion loss and phase characteristics for cables are as follows:
For complete specifications, please refer to ANSI T1.102-1993.
RS-232 CONNECTION
The RS-232 interface be connected to an RS-232 terminal or a PC running a terminal emulation software. The interface is set as follows: 57600 bauds ; 8 data bits ; 1 stop bit ; No parity. The RS-232 cable must be a shielded RS-232 Null-Modem cable with a female DB9 connector.
NOTE: The serial interface is for debug purposes only.
ETHERNET CONNECTION
The Ethernet connection must be made of an unshielded twisted pair (UTP) cable and a standard RJ-45 connector. The Ethernet interface is specified as follows: 10Mb/s ; Half-duplex.
NOTE: The Ethernet interface is for debug and maintenance purposes only.
REPAIRS
Any repair to this board must be carried out by NMS. If you suspect the equipment is malfunctioning, chec
k
the appropriate part of the User’s Guide to make sure that all installation procedures have been followe
d
correctly. If checking the installation procedures does not locate the problem, contact your field servic
e
representative or our home office. For return of material, refer to the RMA section.
RMA –Return Material Authorization
 Check to see if the problem is due to a mistake or oversight in the installation process.  Contact our Technical Services at (450) 676-2977 to confirm that it is a board problem.  While observing correct static-safe handling procedures, disconnect all cables and remove the
board from the chassis. While the board is out, make a note of the serial number (located on a label on the board).
 Contact the RMA coordinator at (450) 676-2977. Give the board’s serial number and a brief
descript ion of the proble m. T he RMA coordinator will give you an RMA number and an estimated return date.
 Pack the board in an anti-static shipping material. Include a printout of the brief description of the
problem.
 Ship the board to NMS at the following address. NMS is not responsible for risk of loss or damage
in transit.
Natural MicroSystems
4200, La Periere, St-Hubert, Qc, Canada, J3Y 9G3
Loading...