Nitek FRS312104S00 User Manual

Installation Manual
FRS312104S00 Single Receiver FRS324104S00 Dual Receiver
1, 2 Camera Receiver w/Data and Aux Comm.
Note: This installation should be made by a qualified service person and conform with local codes.
Reduce risk of fire or electrical shock do
!
not expose this product to rain or moisture.
Specifications
Video Connection
Connector 75 ohm BNC Socket Output Impedance 75 ohm terminated Output Level 1 volt p-p nominal Frequency Response 10Hz to 5.75MHz
Optical Connection
Connector SC Style Path Loss 20dB Wavelength 1310 / 1550nm
Power Connection
Supply 12 to 24 AC/DC @ 300mA
Auxiliary Ports
Data Selectable RS422/RS485/RS232 Alarm In Contact Closure Alarm Out Relay 100V / 150mA max
NITEK ®
5410 Newport Drive, Suite 24 Rolling Meadows, IL 60008 PHONE (847) 259-8900 FAX (847) 259-1300 WWW.NITEK.NET
680600118 Rev 02232009
RS485
DATA CH1
RS422 RS232
RS485
DATA CH2
RS422 RS232
DATA SWITCHES INSIDE UNIT
PIN
ALARM
3
OUT +
4
OUT
­5
IN +
6
GND
DATA SWITCH SETTINGS
DATA
RS485
RS422
1
7
IN + (A)
2
8
IN - (B)
7
7
OUT + (A)
8
8
OUT
(B)
-
6
6
GND
RS485 RS422 RS232
RS485 RS422 RS232
PIN
3 4
­5
IN +
6
GND
DATA
RS232
RS485
RS422
1
7
IN + (A)
2
8
IN - (B)
7
7
8
8
(B)
-
6
6
GND
VIDEO / OPTO
DATA OUT
ALARM OUT
ALARM IN
RS232
2
­8
­6
VIDEO / OPTO
DATA OUT
DATA IN
ALARM OUT
ALARM IN
2
­8
­6
POWER
DATA IN
OPTO IN / OUT
OPTO IN / OUT
POWER
OPTO IN / OUT
OPTO IN / OUT
CH1
CH2
CH1
CH2
CH1
CH2
CH1
CH2
CH1
CH2
VIDEO CH1
VIDEO CH2
1 2 3 4
DATA / ALARM CH1
5 6 7 8
1 2 3 4
DATA / ALARM CH2
5 6 7 8
POWER
­12-24 VDC,
+
300mA, Class 2
NITEK
Fiber Optic Video Transmission Systems
WWW.NITEK.NET 800-528-4343
CLASS 1
R
FRS324104S00
CH1
CH2
VIDEO CH1
VIDEO CH2
1 2 3 4
DATA / ALARM CH1
5 6 7 8
1 2 3 4
DATA / ALARM CH2
5 6 7 8
POWER
­12-24 VDC,
+
300mA, Class 2
NITEK
Fiber Optic Video Transmission Systems
WWW.NITEK.NET 800-528-4343
CLASS 1
R
DATA CH1
DATA CH2
DATA SWITCHES INSIDE UNIT
ALARM
OUT + OUT
DATA SWITCH SETTINGS
OUT + (A) OUT
FRS312104S00
Installation Instructions
- The fiber receiver is designed to be mounted using the included bracket.
- Always allow for bend radius of optical and electrical cables when installed.
Power/Video/Opto LED
Data LED
Color Description
Green Data is Low / Logic 0
Red Data is High / Logic 1 (RS422/485)
Off Data is Tri-state / (High - RS232)
Color Description
Green System Normal
Yellow (RX) Link working, No video at TX
Red (TX) Power on, No video into TX
(RX) Power on, No opto into RX
Service Information
There are no user serviceable parts inside the unit. In the event that service is required to this unit please contact NITEK Technical Support at 800-528-4343.
Typical Installation Diagram
Data In
Aux Comm In / Out (depending on model)
1 2 3 4
DATA / ALARM CH1
5 6 7 8
1 2 3 4
DATA / ALARM CH2
5 6 7 8
Data Connections
AUX COMM IN / OUT DEPENDING ON SWITCH SET­TING
Video Out
(1 or more)
IN + (A) 7 1 2
IN - (B) 8 2 --
OUT + (A) 7 7 8
OUT - (B) 8 8 --
GND 6 6 6
VIDEO CH1
VIDEO CH2
1 2 3 4
DATA / ALARM CH1
5 6 7 8
1 2 3 4
DATA / ALARM CH2
5 6 7 8
POWER
­12-24 VDC,
+
300mA, Class 2
NITEK
Fiber Optic Video Transmission Systems
WWW.NITEK.NET 800-528-4343
CLASS 1
R
DATA CH1
DATA CH2
DATA SWITCHES INSIDE UNIT
ALARM
OUT + OUT
IN +
GND
DATA SWITCH SETTINGS
DATA
IN + (A)
IN - (B) OUT + (A) OUT
POWER
VIDEO / OPTO
DATA OUT
DATA IN
ALARM OUT
ALARM IN
RS485 RS422 RS232
RS485 RS422 RS232
PIN
3 4
­5 6
RS485
(B)
­GND
CH1
OPTO IN / OUT
RS232
RS422
OPTO IN / OUT
1
2
7
2
-
8
7
8
7
8
-
8
6
6
6
15VDC Class 2
Power Supply (Stand Alone)
Rear Panel Data Connections
Data RS485 RS422 RS232
Set Data Format with Internal Switch
RS485
Data CH1
RS422 RS232
Single-Mode Fiber
with SC Connectors
CH2
CH1
CH2
Alarm Connections
Alarm Pin
OUT + 3
OUT - 4
IN + 5
GND 6
Power/Video/Opto LED
Color Description
Green System Normal
Yellow (RX) Link working, No video at TX
Red (TX) Power on, No video into TX
(RX) Power on, No opto into RX
Data LED
Color Description
Green Data is Low / Logic 0
Red Data is High / Logic 1 (RS422/485)
Off Data is Tri-state / (High - RS232)