Nitek ER1651U User Manual

INSTALLATION GUIDE
ER1651U
16 Port IP Video Extender Over Single Twisted Pair
With Built-In Gigabit Layer 2 Switch with EtherStretch
Description
The ER1651U is another component of the NITEK cutting edge EtherStretch line. Our EtherStretch solution al­lows for the utilization of existing twisted pair cable infrastructure to transmit data from IP cameras and other net­work devices over the given copper media well beyond the 100 meter or 328 feet networking distance limitation.
The ER1651U is a Ethernet extending rack mounted sixteen port receiver unit with built-in Gigabit switching capa­bilities. The unit requires very little installation time and absolutely no set up or configuration. Independently the ER1651U will work as a fully functional Layer 2 switch. Additionally, the ER1651U and associated ET1551U trans­mitters (up to 16) can quickly turn ordinary Twisted Pairs into a series of high speed network communication path­ways. When used with remotely powered ET1551U transmitters, the system will allow for cable runs of up to 500m/1600ft supplying both a network connection and PoE power.
The ER1651U is completely transparent to the network thus requiring no IP or MAC addressing. Simply connect your network devices to the transmitter network port along with the existing cables to the receiver and the system quickly begins communicating. LED indicators show the status and data speed of network communications along with Power and Trouble confirmation.
NITEK EtherStretch ER1651U reliably extends network communications to overcome cable distance limitations offering connectivity to devices in locations traditional networking does not allow. The ER1651U is ideal for retro­fitting existing installations. The rack mounted unit is robustly constructed of molded steel casing with appropriate built-in cooling and ventilation.
03262013
NITEK ®
5410 Newport Drive, # 24 Rolling Meadows, IL 60008 Phone: (847) 259-8900 Fax: (847) 259-1300
E-mail: info@nitek.net WWW.NITEK.NET
RoHS
COMPLIANT
2002/95/EC
De Schans 19-21 2a 8231 KA Lelystad Tel: +31(0)320-230005 E-mail: info@nitek.nl WWW.NITEK.NL
EUROPE
Important Safety Instructions
Read all Safety Instructions. Keep the Instructions for future reference. Be sure to HEED Follow ALL DO NOT Clean this device ONLY DO NOT Install in accordance with the manufacturer’s instructions. DO NOT
amplifiers) that produce heat. DO NOT
one blade wider than the other. A grounding plug has two blades and has a third grounding prong. The wide blade and the grounding prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
DO NOT overloaded when the ratings listed on the unit are considered.
Protect the power cord from being walked on or pinched especially at plugs, convenience receptacles and other points where they exit from the device.
Only use attachments and/or accessories specified by the manufacturer.
use this device or any of the equipment described, near water.
block any ventilation openings.
install near any heat sources such as radiators, heat registers, stoves or other apparatus (including
defeat the safety purposes of polarized or grounding type plugs. A polarized plug has two blades, with
connect the unit to an electrical supply if the wiring or over current protection of the supply could be
all Warnings.
instructions.
with a dry cloth.
Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as the power supply cord or plug is damaged, liquid has been spilled on, or objects have fallen into the device, the device has been exposed to rain or moisture, does not operate normally or has been dropped.
WARNING: To reduce risk of fire or electric shock, do not expose this apparatus to rain or moisture. Installation shall be performed ONLY Unless the device is specifically marked as a NEMA 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is designed for indoor
use ONLY
and it must not be installed where exposed to rain or moisture.
by qualified personnel and must conform to all local codes.
Parts of the ER1651U (Front Panel)
Installation Considerations
Wire and Cable Recommendations: The ER1651U is designed for use with up to sixteen (16) Pairs
of Twisted Wire, compatible with all Category cabling (Cat3, Cat5, Cat5e and Cat6). The quality of which must be consistent with any reasonably serviceable cable condition. That is free from damage as in cuts, breaks, or cracks to the outer covering and insulated shielding which may compromise the signal conductivity of the cable.
For more specific information regarding wire types, gauges, and proper installation techniques plea se call Tech Support at 1-(800)528-4343 USA or (847)259-8 900 (outside US).
Ethernet & PoE: The ER1651U is designed to receive up to 100Mbps (per transmitter) of Ethernet data and transmit up to 1 Gigabit of aggregate LAN traffic. Additionally, the ER1651U provides per port sourcing power to operate the transmitter (ET1551U). The transmitter, using the optional power input can support both 15.4W (802.3af) and 25.5W (802.3at) power schemes at a maximum distance of 1,600ft./500m. Before considering this solution be sure that the cable involved does not exceed the recommended maximum lengths. If the cable length is indeterminate at the time of installation, we recommend the use of a time domain reflectometer (TDR) or other method to determine length of unknown cable distance estimates.
Parts of the ER1651U (Rear Panel)
Device Mounting Options
Back
12345678
NITEK
100 Mbps
10 Mbps
PORT PWR
100 Mbps
10 Mbps
PORT PWR
9 10111213141516
Front
Mounting
Ears
The ER1651U is to be rack mounted. Use the included mounting ears when rack mounting the unit, and be sure to follow these guide lines.
a. Operating Ambient - Do not install the unit in an assembly where the ambient temperature could exceed 52°C (125°F). NOTE: the ambient temperature in a closed or multi-unit rack assembly could greatly exceed the ambient temperature outside that assembly. b. Air-Flow – Leave space on the front of the unit for airflow into the cooling fans and some space on top of the unit for air to exit the unit. Adequate air flow is required for safe operation. c. Mechanical Loading – The mounting ears were designed for two ears to support one unit. Other configurations, such as mounting other equipment directly on top of the unit or using only one mounting ear, could cause a hazardous condition due to uneven or excessive mechanical loading.
NOTE: Use all four mounting screws to properly secure the unit to the rack.
Rack Mounting
LAN
1000 Mbps 100 Mbps 10 Mbps
POWER
TROUBLE
ER1651U ETHERSTRETCH RECEIVER
Mounting
Ears