NINGBO BRILLIANT ELECTRONICS BRI810 User Manual

Page 1
Photoelectric And Microwave Motion Sensor Switches
BRI810 instruction
SPECIFICATIONS
Photoelectric And Microwave Motion Sensor Switches
BRI810 instruction
UTILIZING FIELD AND INTRODUCTION
BRI810 is a m ov ing objec t se nsor th at c an d etect r an ge of 360°and i t’s wo rking fre qu ency is 5. 8GHz. The ad vanta ge of this pro duct is stabl e work in g st at e (s ta ble working tem peratur e: -15°C~+7 0° C), BR I810 adopts a mic ro wave se nsor(hi gh -freq ue nc y out pu t<0.2 mW ),so th at it i s saf e and p erfor ms bett er than infrare d se nsor.
FUNCTION AND OPTIONS
If of fe rs 4 levels of the li gh t Control : di mm in g light(0,10%,20%, 30%)--100%--dimming l ig ht (0,10%,20%,30%)--off periods o f se le ct ab le w ai ti ng time:motion holdtime a nd 2 4h ou rs , selectable daylight threashold,and freedom of detection ara. If natral l ig ht lower L ig ht -c on tr ol setting (10Lux,30Lux,50Lux),the l ig ht will not au to ma ti ca ll y on (0,10%,20%,30%). When person enter in the room,the light will on 10 0% ,a ft er pe rs on le ft the room,the room enter in semi bright brightness after hold on time.
Power supply
Maximum load
@ -40°F ~ 158°F
(-40°C ~ 70°C)
HF System Dim control output Detection radius/angle Mounting height Remote range Humidity Temperature
NOTE:
is <0.2mW-that is just one 5000 of the transmission
The high-frequency output of this sensor
120-277VAC
Resistive/Tun gs te n - 60 0W @1 20 V Ballast Electronic (LED) - 800/1200VA@120/277V
Max meters/360° Max 20ft 33ft. (10m) indoor, no backlight Max. 95% RH
-104°F ~ 158°F (-40°C ~ 70°C)
th
power of a mobile phone or the output of a microwave oven.
SENSOR INFORMATION
Max:25ft
Min:5ft
Min:5ft
Transmission power<0.2mW
Max:25ft
Wit h suf fcie nt na tur al ligh t,
th e ligh t do es no t sw itc h on
wh en pr es enc e dete cte d.
Wit h ins uff ici ent na tural the s ensor s witch es on th e lig ht aut omati cally w hen pe rso n ent ers the
(op tions ) stand by
lev el afte r the T he lamp
nev er swit ch off wi th pres ence, eve n the nat ure lig ht is suf ficie nt.
lig ht,
roo m.
Peo ple le ft, ligh t sti ll dim s to 0/1 0%/2 0%/ 30% ( opt ion s)
sta ndby le vel aft er the ho ld tim e.
Lig ht swit ches of f autom atica lly aft er the di mming t ime ela psed.
WIRING DIAGRAMS
BRI810 wiring with dimming ballast or LED driver.
Dimming Driver
LINE(Black)
LOAD(Red)
NEUTRAL(White)
360
Dimming
Driver
NEUTRAL(White)
BRI810 wiring with non-dimming ballast or LED driver.
Non-Dimming Driver
LINE(Black)
LOAD(Red)
NEUTRAL(White)
Non-Dimming
Driver
NEUTRAL(White)
8~20ft
Height of installation8~20ft
(Height of installation8ft)
Detection range
-1-
Detection angel
GRAY (-)
VIOLET (+)
Close End Wire Connector
-2-
Page 2
Photoelectric And Microwave Motion Sensor Switches
BRI810 instruction
Photoelectric And Microwave Motion Sensor Switches
BRI810 instruction
SETTING BY REMOTE CONTROL
Press the on/off button,the light
ON/
goes to permanent or permanent
OFF
off mode,sensor is disabled.
Memory the paraments
M
Pre ss auto m ode but ton,t he
ON/ OFF
20%
Sensitivity
10SEC
Stand-by time
15MIN
Lux
0
Dimming level
24H
Dimming time
M
50%
1MIN
30MIN
10LUX
10%
1MIN
AUTO
75%
5MIN
60MIN
30LUX
20%
30MIN
RESET
100%
TEST
50LUX
30%
60MIN
sen sor sta rts to wo rk and al l set tings r emain t he same a s
AUTO
the l atest s tatus b efore t he lig ht was sw itche d on/of f.
20% 50 %
Sen sitiv ity
100%
75%
Press this button,the latest surounding lux value overwrites previous lux value learned,and is set as the daylight threshold. This feture enables the fixture to function well in any real application circumstance.
0 10%
Sta nd-by d immin g level
20%
30%
INSTALLATION
This product can be utilized in more fields than the above examples. You can also install BRI810 alone to act intelligent switch to control other load.
This button test 2s is for testing prupose only.the sensor goes to test mode(hold time 2s)
TEST
automatically after commissioning, meanwhile the stand-by period and daylight sensor are diabled.
10SE C
20MI N
One touch button, the default is
75%
RESE T
10MI N
Hol d-tim e
30MI N
10SE C
24H
The product can not work normally if there is metal
material in of the Installed place.front
This product will be faithfully waiting for you.It will turn on the light automatically when you pass by,and turn
off the light automatically when you leave off. You can set the closing delay time to meet your needs. For
Warning!
Non-metal material
when the sensor is installed inside the ceiling floor, the sensitivity to light will be invalid.
example,you may adjust the delay time 10sec~60min when you think you will come back in 60mins.
Press the buttons of the daylight
10
Lux
sensor to set daylight threshold at 10lux/30lux/50lux/ ( for daylight
30
50
Lux
Lux
30MI N
1MIN
24H
60MI N
sensor disabled).
Sta nd-by p eriod (note :24H is nev er off)
Warning!
1. Being installed in the rocking object will lead to misoperation.
2. The shaking curtain which is blown by wind will lead to misoperation, please select the suitable installed place.
3. Being installed in the place where the traffic is busy will lead to misoperation.
4. It will lead to misoperation when there are sparks produced by some equipment nearby.
The following situation will lead to misoperation
FCC STATEMENT
1. This d ev ic e compl ie s with Pa rt 1 5 of t he FCC Ru le s. Oper at io n is subj ec t to the fo ll owing two c on ditio ns : (1) Thi s de vi ce may no t ca use har mf ul i nterf er ence. (2) Thi s de vi ce must a cc ept any i nt er feren ce r eceiv ed , in cludi ng i nterf er en ce that m ay c ause un de si red opera ti on .
2. Change s or m odifi ca tions not e xp ressl y ap prove d by t he p arty re sp onsib le f or c ompli an ce coul d vo id the use r' s au thori ty t o opera te t he e quipm en t. NOTE: T hi s eq uipme nt h as been t es te d and fou nd t o compl y wi th t he limi ts f or a Clas s B di gital dev ic e, pursuan t to P art 15 of t he F CC Rule s. T he se limi ts a re desi gn ed t o provi de r eason ab le p rotec ti on agai ns t harmful i nt erfer en ce in a res id en tial in st allat io n. T his equ ip ment ge ne ra tes use s an d can rad ia te r adio frequ en cy e nergy a nd , if not in st al led and u se d in accord an ce with t he i nstru ct io ns, may c au se harm fu l interfe re nce to ra di o commu ni ca tions . Ho wever , th er e is no gua ra ntee th at i nt erfer en ce will n ot o cc ur in a parti cu la r insta ll ation. If t hi s equip me nt does c au se h armfu l in terfe re nc e to radi o or t elevi si on r ecept io n, which can b e de termi ne d by turnin g th e equip me nt off an d on , th e user is e nc ourag ed t o tr y to corr ec t the interfe re nce by on e or m ore of th e fo ll owing m ea sures : Re or ient or r el ocate t he r ec eivin g an tenna . In cr ease the sep ar at ion bet we en the equi pm ent and r ec eiver.C on nect th e eq uipment i nt o an outl et o n a circu it diffe re nt f rom tha t to w hich th e re ce iver is c on necte d. Co nsult t he d ealer o r an e xp erien ce d radio /T V techn ic ia n for hel p.
-3- -4-
E484113
Loading...