B L E N D I N G H I G H F I D E L I T Y A N D A R C H I T E C T U R E
1 2 3 3 1 S . W . 1 3 0 S t r e e t M i a m i , F l o r i d a 3 3 1 8 6
N i l e s A u d i o C o r p o r a t i o n
3 0 5 - 2 3 8 - 4 3 7 3 • 1 - 8 0 0 - B U Y - H I F I
w w w . n i l e s a u d i o . c o m
©2 00 7 Ni le s Au di o Co rp or at io n. Al l ri gh ts r es er ve d. N il es , th e Ni le s
lo go s, I nt el li Pa d, M ic ro fl as her s, M ic ro se ns or a nd B le nd in g Hi gh F id el ity a nd
Ar ch it ec tu re a re r eg is te re d tra de ma rk s of N il es A ud io C or po ra ti on . Al l o th er
tr ad em ar ks a re t he p ro pe rt y of th ei r re sp ec ti ve o wn er s. DS 00 56 4A
Figure 3 Parts guide
(a) Mounting surface
(b) IR Cable (10 feet supplied)
(c) CS110 Miniature IR Sensor (supplied)
(d) Installation screws (supplied)
(e) CS110 lens bezel (supplied)
®
Figure 5 Suggested wiring of CS110 to Niles
IntelliPad Ci keypad via an RJ45 jack
Figure 4 Removing the bezel
OPERATION
Operation of the CS110 is straightforward. Simply
aim your hand-held remote at the CS110. Your IR
command is instantly repeated to your A/V equipment.
TROUBLESHOOTING
This manual contains instructions for the CS110
only. For specific information on the adjustment
and operation of your Niles infrared extender system, please refer to the instruction manual included
with your Niles IR main system unit (MSU140,
MSU250, MSU480, MSU440Z).
1. Test the remote control(s) by operating the A/V
equipment directly. Replace the batteries if
needed
2. Double check the cable connections on the
CS110 and on the main system unit. Look for
open, shorted or reversed wires (Figure 2)
3. Test for interference from the following sources:
• Neon or halogen lights in the room
• Light dimmers, beginning with those closest
to the CS110
Observe the main system unit IR confirmation LED
while performing all the tests. It is possible to have
interference from more than one source.
Eliminating Optical Feedback
In some installations, two conditions combine to
create an optical feedback loop. Symptoms can
9
10
11 1312
include: poor range, intermittent operation or no operation.The conditions which sometimes combine
to create a feedback loop are:
1. Both a sensor and a flasher are located within
the same room
2. There is some low-level noise or interference on
your system
You can eliminate optical feedback by replacing any IRB1 “flooding flasher” with MF1 or MF2
MicroFlashers® and covering all flashers with the
supplied IR blocking covers.
EMI (Electromagnetic Interference)
Identify the source of the interference. The most
common sources of electromagnetic interference
are listed in the Installation Considerations section.
To eliminate EMI try the following methods:
1. Move the sensor or the sensor cable away from
the EMI source or move the source of the EMI
away from the sensor or the cable
2. Connect the Sensor’s GND terminal to true earth
ground (if this isn’t feasible use the main system
unit’s GND terminal)
There are many methods for reducing interference.
Which solution is best for you depends on your
situation. If you require further assistance call Niles
Technical Support at 305-238-4373 or 1-800-2894434 (M-F 8:00 AM - 7:00PM ET).
You can also email Niles Technical Support at
support@nilesaudio.com.
SPECIFICATIONS
IR System
Compatible with virtually all brands of remotes
using carrier frequencies of 38kHz, 40kHz and
56kHz
IR Receiving Range
Varies depending on remote strength;
Typically 20 to 35’
IR Receiving Angle
60° off-axis (horizontal and vertical) at 20’
Mounting
Thru-hole, fits into a 1/2” diameter hole; requires
a minimum of 2-5/8” mounting depth
Wiring Requirements
Individual home-runs of CAT-5 cable
Unit Dimensions
Front Bezel: 3/4” Diameter x 1/4” high
Lens Bezel: 1-1/2” Diameter x 41/64 high
Unit With Dome: 1/2” Diameter x 3” Long
Unit Without Dome: 1/2” Diameter x 2-7/8” Long
Contents
• CS110 Miniature IR Sensor
• Installation Screws (3)
• CS110 Lens Bezel
• Mounting Bracket
LIMITED WARRANTY
NILES AUDIO CORPORATION (“NILES”) WARRANTS ITS PASSIVE PRODUCTS
(THOSE NOT REQUIRING AC OR BATTERY POWER) TO THE ORIGINAL
PURCHASER TO BE FREE OF MANUFACTURING DEFECTS IN MATERIAL AND
WORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF PURCHASE.
THIS WARRANTY IS SUBJECT TO THE FOLLOWING ADDITIONAL CONDITIONS
AND LIMITATIONS. THE WARRANTY IS VOID AND INAPPLICABLE IF
NILES DEEMS THAT THE PRODUCT HAS BEEN USED OR HANDLED OTHER
THAN IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED BY THE
MANUFACTURER, INCLUDING BUT NOT LIMITED TO DAMAGE CAUSED BY
ACCIDENT, MISHANDLING, IMPROPER INSTALLATION, ABUSE, NEGLIGENCE,
OR NORMAL WEAR AND TEAR, OR ANY DEFECT CAUSED BY REPAIR
TO THE PRODUCT BY ANYONE OTHER THAN NILES OR AN AUTHORIZED
NILES DEALER.
TO OBTAIN WARRANTY SERVICE, TAKE THE UNIT TO THE NEAREST
AUTHORIZED NILES DEALER, WHO WILL TEST THE PRODUCT AND IF
NECESSARY, FORWARD IT TO NILES FOR SERVICE. IF THERE ARE NO
AUTHORIZED NILES DEALERS IN YOUR AREA, YOU MUST WRITE TO NILES
AND INCLUDE YOUR NAME, MODEL AND SERIAL NUMBER OF YOUR UNIT,
ALONG WITH A BRIEF DESCRIPTION OF THE PROBLEM. A FACTORY RETURN
AUTHORIZATION NUMBER WILL BE SENT TO YOU. DO NOT RETURN ANY
UNIT WITHOUT FIRST RECEIVING WRITTEN AUTHORIZATION AND SHIPPING
INSTRUCTIONS FROM NILES.
IF THE ABOVE CONDITIONS ARE MET, THE PURCHASER’S SOLE REMEDY SHALL
BE TO RETURN THE PRODUCT TO NILES, IN WHICH CASE NILES WILL REPAIR
OR REPLACE, AT ITS SOLE OPTION, THE DEFECTIVE PRODUCT WITHOUT
CHARGE FOR PARTS OR LABOR. NILES WILL RETURN A UNIT REPAIRED OR
REPLACED UNDER WARRANTY BY SHIPPING SAME BY ITS USUAL SHIPPING
METHOD FROM THE FACTORY (ONLY) AT ITS EXPENSE WITHIN THE UNITED
STATES OF AMERICA. THERE ARE NO OTHER WARRANTIES, INCLUDING
WITHOUT LIMITATION, EITHER EXPRESS OR IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH
RESPECT TO THE PRODUCT.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE
EXCLUSIVE REMEDY OF THE CONSUMER/PURCHASER. NILES SHALL NOT BE
RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT
TO THE EXTENT PROVIDED (OR PROHIBITED) BY APPLICABLE LAW.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY
NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE
TO STATE.
FOR THE NAME OF YOUR NEAREST AUTHORIZED NILES DEALER
CONTACT: NILES AUDIO CORPORATION, P.O. BOX 160818, MIAMI,
FLORIDA 33116-0818.
Please fill in your product information and retain for your records.
Model__________________Purchase Date ________________
Serial No. __________________________________________
I N S T A L L A T I O N & O P E R A T I O N G U I D E
CEILING-MOUNT IR MICROSENSOR
®
CS110
INTRODUCTION
The CS110 is a ceiling mounted IR sensor designed
for use with the Niles infrared extender systems.
Installed in a remote room location, the CS110
receives the IR commands transmitted from your
existing hand-held remotes in that room. The
commands are carried via a category 5 cable to
your A/V equipment in another room, and instantly
“repeated”.
The CS110 is compatible with all current Niles
infrared systems. It may be used along with, or as
an alternative to, the Niles TS110, MS110, MS210,
WS110R and MVC100IR sensors or the IntelliPad®.
The CS110 is just one part of the three building
blocks necessary to complete a Niles IR repeating
system
• IR Main System Unit—Models MSU140, MSU250,
MSU480 and MSU440Z
• IR Sensors/Keypads—Models WS110R, TS110,
MS110, MS210, CS110 and the IntelliPad
• IR Flashers—Models MF1, MF2, MF1VF,
MF2VF and the IRB1
An IR sensor expansion hub, Model IRH610, is
available to provide additional sensor inputs to your
system.
FEATURES & BENEFITS
The CS110 offers a number of improvements over
other miniature IR sensors.
• Plasma and LCD-proof performance—allows
placement of the CS110 near plasma and LCD
displays
• CFL interference resistant—expands installation
flexibility to areas with fluorescent lighting
• Works under most lighting conditions, including indirect sunlight—eliminates environmental
restrictions
• Universal system—compatible with virtually all
brands of A/V equipment and remote controls
• Excellent IR receiving range — 20’ to 35’ of
remote control range (depending upon the
strength of your handheld remote)
• 100% factory tested for pickup range and angle
• Small size of only 1/2” diameter by 2-7/8”
long—fits almost anywhere
• 10’ of connecting wire included
• Printed circuit board design uses surface mount
technology, assuring high reliability
• Ideal for both home and commercial installations
• Each CS110 includes a transparent cover
• Two year parts and labor warranty
INSTALLATION CONSIDERATIONS
IMPORTANT: REFER INSTALLATION TO A PROFESSIONAL CUSTOM INSTALLER IF YOU ARE UNFAMILIAR WITH ANY OF THE FOLLOWING PROCEDURES.
TOOLS REQUIRED
• 1/8” Standard Slotted Screwdriver
• 1/4” Standard Slotted Screwdriver
• Wire Stripper
Type of Cable
The CS110 connects to the Niles Infrared main systems unit or IRH610 sensor expansion hub with an
individual home run of CAT-5 cable. When running
wires inside walls, most states and municipalities
in the U.S. specify that you must use a special type
of wire. Usually, the requirement is that the wire
has a specific “CL” fire rating, such as “CL-2” or
“CL-3”. Consult your Niles dealer, building contractor, or local building and inspection department if
unsure about which type of wire is best for your
application.
CS110 Mounting Location
The CS110 is designed to be ceiling mounted in
a direct line of sight location within the operating
range of the remote control.
Receiving Range and Pickup Angle
The receiving range of the CS110 will vary according to the IR output strength of the remote control
being used. Remote strength varies among brands
depending on the number and size of batteries
used, and how many IR emitters the remote has.
For example, remotes that operate on two small
AAA batteries and have only one IR emitter are
generally not as strong as remotes that use the
larger AA size batteries and have two emitters.
Tests with various manufacturers’ remote controls
have shown that the operating range can vary from
a minimum of 20’ to a maximum of about 35’.
Infrared signals travel essentially line-of-sight. They
will not pass through or around solid objects. Do
not rely on an IR signal being able to “bounce” off a
wall or object to the CS110. The IR pickup angle of
the CS110 is 60° off-axis (horizontal and vertical)
at 20’.
Avoiding Interference
CS110 is designed to work in most applications
including LCD and plasma displays and in areas
where CFL lighting and indirect sunlight are
present. You should avoid locating the CS110 near
potential sources of electrical or optical noise, such
as light dimmers or low-voltage lights.
Avoiding Optical Feedback
If installing the CS110 in the same room as an IR
flasher, it is possible for the flasher’s IR output to
be picked-up by the CS110. This effect, known
as an optical feedback loop, can cause erratic
operation. Optical feedback is similar to acoustical
feedback: the howling or whistling sound heard in
a P.A. system when the microphone is too close to
the speaker.
To avoid optical feedback:
1. Re-position the flasher(s) and/or the sensor
2. Use Niles MF1 or MF2 Microflashers and cover
them with the supplied IR blockers
Using the CS110 with the Intellipad Ci system
The CS110 is fully compatible with the Niles Intellipad Ci line, follow the wiring instructions in Figure
5. For specific information see your Intellipad Ci
manual.
INSTALLATION
If you are installing the CS110 into an existing
ceiling, take time to consider any possible obstructions which may be hidden, such as wood or metal
studs, electrical, telephone or other types of wiring,
plumbing, AC or heating conduits, etc.
1. Determine a mounting location for the CS110
2. Drill a 1/2” hole where the CS110 will be
mounted
3. Run the CS110’s IR cable. Label the cable for
future reference ( Figure 2). The CS110 is supplied with 10’ of pre-stripped IR cable. The IR cable may be shortened or lengthened as needed.
If you want to make the CS110’s cable shorter,
use a pair of wire cutters to cut the cable to the
desired length. The IR cable may be lengthened
by splicing it to a recommended IR cable (See
Installation Considerations—Type of Cable). You
may splice the CS110 cable to another cable by
soldering or crimping the connections.
5 63 41 2 7 8
4. Fasten sensor to ceiling with supplied screws
( Figure 3)
5. Connect the CS110 cable to the main system
unit ( Figure 1). Strip 1/4” of insulation from
the end of each wire. Tightly twist the end of
each wire until there are no frayed ends. Insert
each wire into the appropriate hole on the
removable connector plug, and snap the locking
tab down.
To help you, the connector plug is keyed. Insert the
smooth side of the connector plug into the smooth
side of the socket. Don’t force the scalloped side
of the connector plug into the smooth side of the
socket. Refer to the main system main system unit
manual for specific installation instructions.
12V DC power supply
(supplied with the
MSU250 main system
unit) plugged into an
unswitched AC outlet
powers the system
Figure 1 Wiring diagram
(installed in an MSU250 system)
Niles IR flasher
12V DC Power supply (not sup
plied) plugged into the switched
MSU250
Power, IR data, status signal and ground
via category 5 wire
Figure 2
Wiring legend
outlet.
Stereo receiver
-
Niles stock# FG01035
CS110