Niigata seiki DEI-233S1, DEI-233S2 Instruction Manual

SWISS MADE
MODE SET
SWISS MADE
MODE SET
CR2032
IP65 class waterproof rating Small size ABS and REL measurement modes ABS mode: With Display Hold REL mode: With one touch Preset recall Direction of measurement (+ / −) switchable Preset function Auto-off feature (approx. 4 hour
)
REL mode only
Made in Switzerland
LCD Display
[
SET] Button
Stem (
Mounting Shaft
)
Spindle
Contact Point
[
MODE] Button
Battery Cover
Model No. DEI-233S1/DEI-233S2 <combined>
Thank you for purchasing the Digital S-Line Indicator. For proper operation, please read this manual thoroughly before use.
DIGITAL S-LINE INDICATOR(IP65
Accessories
CR2032
CR2032
(
Lithium Cell
)
Included for test
FEATURES
BATTERY REPLACEMENT
Remove the (2x) battery screws using (+) PH#0
screwdriver. Place a small standard screwdriver in the notch to gently pry open the cover and slide out the battery.
Insert the new battery following the polarity markings
on the cover.
Replace Battery Cover and tighten screws to secure.
SPECIFICATIONS
YES
φ8mm
70g
540
CR2032(Lithium cell)×1
DEI-233S1
0.001mm0.01mm
0.01mm
0.01mm/0.001mm (
switchable
)
0.02mm
0.002mm
up to ±130mm
0-12.5mm
Less than 1.5N
0.005mm
DEI-233S2
Model No.
Measurement Range
Resolution
Displayed Resolution
Accuracy
Measurement Force
Repeatability
Preset
Measurement Dir. Switchable
Mounting Shaft Diameter
Operating Temp. Range
Power Supply
Weight
Battery
Battery Cover
Battery Cover
Notch
PARTS IDENTIFICATION
NOTICE
Use only CR2032 type battery.
See Reverse for How to Use”→
TROUBLESHOOTING
Error Condition Corrective Action
Measured value is wrong
Clean measuring surfaces with lens tissue or similar. Confirm and re-set 0-Point setting.
LCD does not display Displayed value is unstable Display is hard to read
Cycle power by removing and replacing battery. Replace battery with new one.
If problem persists, or if you have any questions, please contact distributor
or place of purchase.
Please note, manufacturer is unable to respond to inquires or provide
service directly. Please contact distributor or place of purchase.
Read Error. Reset the sensor by pressing the [
MODE] or [SET] button.
If message is displayed again, there
is possibility that the memory is corrupted; Please contact distributor or place of purchase.
Err 0 is Displayed on LCD
INSTRUCTION MANUAL
Mount indicator securely, such as on optional Magnetic
Base, and make sure that the Spindle is perpendicular to the measurement surface.
Press [MODE] or [SET] to turn on power. ③Setting 0-Point.
 <REL Mode>  With gauge in contact with reference surface, press the
[
SET] button.
Display will read 0.00mm.
 <ABS Mode>  With gauge in contact with reference surface, press the
[
MODE] button. When display reads SEt, press the
[
SET] button. (ref. Function Setup - Preset Function
)
Display will read 0.00mm.
If 0.00mm is not displayed, please refer to Function
Setup - Preset Value to set value to 0.00mm, and then perform steps to .
With Gauge body held fixed, and the probe in contact
with the workpiece, the LCD will display the difference between workpiece and reference plane.
This is a precision instrument, handle with care. Do not drop or subject to excessive forces. Keep away form high voltage and strong magnetic fields; instrument damage may result. Do not use or store in direct sunlight or locations with high temperatures such as in a car, or near a stove or heat source. When taking measurements, hold gauge securely, such as in magnetic base. (sold separately
) Please do not disassemble or modify. Remove dust and cutting chips after use and apply rust preventative oil to metallic surfaces. Please keep out of reach of children. Do not use organic solvents to clean the body of the instrument. When not being used for a long period of time, please remove battery. Only use as directed. Improper use may cause accident or injury.
If no operation is performed after 5 seconds, display
will return to the measurement screen.
ABS / REL Mode
This function not available.
Preset Value】
Numerical value can be preset, and later called up to measurement screen.
ABS
Measurement Direction
Measurement Screen
Switchable between ABS or REL modes.
ABS mode
Press [SET] Button to hold the
displayed reading. Press once and H icon will show, and value will hold. Press again to release.
REL mode
At any probe position, press the
[
SET] button to call up and display the Preset Value. (
see Preset Value” below
)
Preset Function
Preset Value set can be called up for display. For use in ABS, or REL mode.
Resolution
DEI-233S2 only
I299-K 1604
Niigata seiki Co., Ltd.
6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055 Tel. : +81-256-31-5670 Fax. : +81-256-39-7730
MAIL intl.sales@niigataseiki.co.jp URL http://www.niigataseiki.co.jp
HOW TO USE
Press the [MODE] button to cycle through the functions in the sequence shown below. When desired function is displayed, press [SET] button to access the various settings.
FUNCTION SETUP
CAUTION
Press [MODE] to display ABS / REL, then press [SET] to select.
To Set
Press [MODE] to move cursor, and press [SET] to change value.
To Set
Press [MODE] to display Inc (+) / dEc (-), then press [SET] to select.
To Set
Press [MODE] to display 0. 01 / 0. 001, then press [SET] to select.
To Set
[
MODE] Button
[
MODE] Button
[
MODE] Button
[
MODE] Button
[
MODE] Button
[
MODE] Button
[
MODE] Button
Power ON】
Press [MODE], or [SET] button to turn on power.
Power OFF】
Press and hold the [SET] button to turn off power. Power will switch off automatically if idle after
approximately 4 hours.
(※REL Mode only
)
When battery level is low, the icon is displayed;
please replace battery.
POWER
B