NICOR Lighting NCOL2318 w

Page 1
HML1
LED High-Performance High Bay
Project
Product Description
NICOR introduces the newest high bay product line: the patent pending, ultra-ecient, high performance HML high bay. With only a 10x14" footprint (on lower wattages), its compact design oers an impressive light output with simple, single-person installation. The DLC 5.1 Premium certied xture oers a variety of wattage, sensor, and aisle distribution options. It's durable single-piece cast aluminum design is perfect for rugged applications like warehouses, gymnasiums, and other industrial or commercial spaces.
Construction
• Fully cast aluminum body with integrated cooling features
• Top mounted wireway cover for easy wire access
• Polyester powder coat nish
Optical System
• Standard diused lens
• Optional aisle lens (40° x 100°) available
• Optional wide lens (105° x 105°) available
• CCTs of 4000K and 5000K with >80 CRI
Electrical
• Oers multiple power levels: 100W, 130W, 150W, 210W, 300W and 450W
• Operating temperature rating of -4ºF to 131ºF (-20ºC to 55ºC)
• Input voltage of 120-277V, 277-480V input option available
• Dimming: 0-10V standard
Controls
• Pre-installed sensor socket models available
• Field installable multifunction MW or PIR sensor available (on sensor socket models)
• Standard full-range dimming with compatible 0-10VDC dimmers
• 12VDC output provides power to o-board sensors or controls
Mounting and Installation
• V-hook and chain mounting system included
• Wireguard option available for increased xture protection
• Pendant mount and surface mount kits available
• For installations where power surge may be possible, NICOR recommends installing additional surge protection at the xture or electrical distribution panel
Listings
• cULus1598 Listed for damp locations
• ASHRAE 90.1 compliance when specied with sensor option
• RoHS Compliant
• Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions
• TM-21 Reported L70(10k) life >60,000 hours
• LM-79, LM-80 testing performed in accordance with IESNA standards
Warranty
• 5-year limited system warranty standard
• Warranty does not cover product failure due to an overvoltage event (power surge)
Catalog
Type
Date
HML1
100W, 130W,150W
210W, 300W, 450W
LED High-Performance High Bay
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 1 of 7
Page 2
HML1
LED High-Performance High Bay
Ordering Information
Example: HML1150U50AS
Series Version Wattage Input Voltage CCT Distribution Sensor Socket Emergency Wiring Options
HML
1
Specications and dimensions subject to change without notice.
1) Only on 150W and higher models
2) 8W is for 100W version only
3) 18W for 100-150W versions only
4) 25W is for 210W version only
5) 40W is for 300-450W versions only Note: End user is reponsible for proper selection of battery pack to meet NFPA requirements
6) C3 Cord is 18/3 wire, 6’ long, black. Other lengths available upon request
7) C4 cord is 18/4 wire, 6’ long, black, for use with Emergency enabled xtures. Other lengths available upon request
8) Flexible metal conduit is 6’ long, 18/3 wire conguration. Other lengths available upon request
100 (14000 lm) U (120-277V) 40 (4000K ) A (general - 90°x90°) Blank (No) Blank (No) Blank (No)
130 (18000 lm) H (277-480V)
150 (20000 lm) C (aisle - 40°x100°)
210 (29000 lm)
300 (42000 lm)
450 (66000 lm)
1
50 (5000K) B (wide - 105°x105°) S (socket) E08 (8W)
1
E18 (18W)
E25 (25W)
E40 (40W)
2
3
4
5
C (Cord - 3-wire, 6ft)
C4 (Cord - 4-wire, 6ft)
F (Flex Conduit - 6ft)
Motion Sensors
Passive Infrared Motion Sensor H12VSENSORPIR
Microwave Motion Sensor H12VSENSORMW
Remote Control for Sensors H12VREMOTE
Motion sensors for use on socket enabled (“S”) xtures only
Wireguard Accessories
Wireguard for HML1 100-150W HML1WGNS
Wireguard for HML1 210-300W HML1WGND
Wireguard for HML1 450W HML1WGNT
6
7
8
Mounting Accessory Kits
Aircraft Cable Kit (10ft) ACMK110
Pendant Kit for 100-450W HML1100-150PEND
Surface Mount Kit for 100-450W HML1100-150SURFACE
Pendant and surface mount kits compatible to all HML models, 100W-450W
Emergency Battery Accessories
8W Battery Pack (120-347V) HML1EM08WRVWH
18W Battery Pack (120-347V) HML1EM18WRVWH
25W Battery Pack (120-347V) HML1EM25WRVWH
40W Battery Pack (120-347V) HML1EM40WRVWH
• For installation in the eld by the end user
• 8W is for 100W version only
• 18W for 100-150W versions only
• 25W is for 210W version only
• 40W is for 300-450W versions only
• End user is reponsible for proper selection of battery pack to meet NFPA requirements
Plug Accessories
15A 125V Straight Bladed Plug 515P
15A 125V Twist Lock Plug L515P
15A 250V Twist Lock Plug L615P
15A 277V Twist Lock Plug L715P
20A 277V Twist Lock Plug L720P
20A 347V Twist Lock Plug L2320P
20A 480V Twist Lock Plug L820P
Plugs not available for C4 (4-wire cord) or F (ex conduit) options
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 2 of 7
Page 3
HML1
LED High-Performance High Bay
Performance Data
Standard Distribution
Model Number Lumens Watts Lumens/Watt HML1100U40A 14200 HML1100U50A 14284 141 HML1130U40A 18138 HML1130U50A 18228 141 HML1150U40A 20574 HML1150U50A 20675 141 HML1210U40A 29258 HML1210U50A 29412 141 HML1300U40A 42055 HML1300U50A 42266 138 HML1450U40A 66516 HML1450U50A 66850 145
Emergency Operation Lumens
Model Number 8W 18W 25W 40W HML1100U40A 1128 2538 X X HML1100U50A 1128 2538 X X HML1130U40A X 2538 X X HML1130U50A X 2538 X X HML1150U40A X 2520 X X HML1150U50A X 2538 X X HML1210U40A X X 3500 X HML1210U50A X X 3525 X HML1300U40A X X X 5480 HML1300U50A X X X 5520 HML1450U40A X X X 5760 HML1450U50A X X X 5800
101
129
147
209
305
459
141
141
140
140
137
144
Wide Distribution
Model Number Lumens Watts Lumens/Watt HML1100U40B 14200 HML1100U50B 14284 141 HML1130U40B 18138 HML1130U50B 18228 141 HML1150U40B 20574 HML1150U50B 20675 141 HML1210U40B 29258 HML1210U50B 29412 141 HML1300U40B 42055 HML1300U50B 42266 138 HML1450U40B 66516 HML1450U50B 66850 145
Emergency Operation Lumens
Model Number 8W 18W 25W 40W HML1100U40B 1128 2538 X X HML1100U50B 1128 2538 X X HML1130U40B X 2538 X X HML1130U50B X 2538 X X HML1150U40B X 2520 X X HML1150U50B X 2538 X X HML1210U40B X X 3500 X HML1210U50B X X 3525 X HML1300U40B X X X 5480 HML1300U50B X X X 5520 HML1450U40B X X X 5760 HML1450U50B X X X 5800
101
129
147
209
305
459
141
141
140
140
137
144
Aisle Distribution
Model Number Lumens Watts Lumens/Watt HML1150U40C 19134 HML1150U50C 19228 131 HML1210U40C 27204 HML1210U50C 27338 131 HML1300U40C 39251 HML1300U50C 39307 131 HML1450U40C 61860 HML1450U50C 62171 135
Emergency Operation Lumens
Model Number 18W 25W 40W HML1150U40C 2340 X X HML1150U50C 2358 X X HML1210U40C X 3250 X HML1210U50C X 3275 X HML1300U40C X X 5240 HML1300U50C X X 5240 HML1450U40C X X 5360 HML1450U50C X X 5400
147
209
305
459
130
130
131
134
Fixture tested per LM-79-08. Photometric data is of the performance of a representative xture. Results may vary in the eld.
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 3 of 7
Page 4
HML1
LED High-Performance High Bay
Photometric Data
100W 5000K
Input Voltage (VAC) 120-277 277-480
System Level Power (W) 101.0 98
Delivered Lumens (Lm) 14284 13858
System Ecacy (Lm/W) 141.4 141.4
Correlated Color Temp (K)
Color Rendering Index (CRI) 86
Beam Angle (0) 89.1
Beam Angle (90)
Spacing Criteria (0) 1.26
Spacing Criteria (90) 1.26
3553
90.6
CCT Data Multiplier
4000K 0.995
130W 5000K
Input Voltage (VAC) 120-277 277-480
System Level Power (W) 129 125
Delivered Lumens (Lm) 18228 17573
System Ecacy (Lm/W) 141.3 140.6
Correlated Color Temp (K)
Color Rendering Index (CRI) 86
Beam Angle (0) 89.0
Beam Angle (90)
Spacing Criteria (0) 1.26
Spacing Criteria (90) 1.26
3560
90.6
6897
5172
3449
1724
8742
6561
4371
2185
Cone of Light Tabulation
Mounted height
(Feet)
15 30.0 29.5 17 23.4 33.5 20 16.9 39.4 23 12.8 45.3
Footcandles
Beam Center
Cone of Light Tabulation
Mounted height
(Feet)
15 38.4 29.5 17 30.0 33.5 20 21.7 39.4 23 16.4 45.3 25 13.8 49.2
Footcandles
Beam Center
Diameter
(Feet)
Diameter
(Feet)
CCT Data Multiplier
4000K 0.995
10123
150W 5000K
Input Voltage (VAC) 120-277 277-480
System Level Power (W) 147 147
Delivered Lumens (Lm) 20675 20664
System Ecacy (Lm/W) 140.6 140.6
Correlated Color Temp (K)
Color Rendering Index (CRI) 86
Beam Angle (0) 88.9
Beam Angle (90)
Spacing Criteria (0) 1.26
Spacing Criteria (90) 1.26
3532
90.6
CCT Data Multiplier
4000K 0.995
Fixture tested per LM-79-08. Photometric data is of the performance of a representative xture. Results may vary in the eld.
7592
5051
2531
Cone of Light Tabulation
Mounted height
(Feet)
15 43.7 29.5 17 34.1 33.5 20 24.6 39.4 23 18.6 45.3 25 15.7 49.2 28 12.5 55.1
Footcandles
Beam Center
Diameter
(Feet)
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 4 of 7
Page 5
HML1
LED High-Performance High Bay
Photometric Data
210W 5000K
Input Voltage (VAC) 120-277 277-480
System Level Power (W) 209
Delivered Lumens (Lm) 29412 29396
System Ecacy (Lm/W) 141 141
Correlated Color Temp (K)
Color Rendering Index (CRI) 85
Beam Angle (0) 88.7
Beam Angle (90)
Spacing Criteria (0) 1.28
Spacing Criteria (90) 1.26
5000
90.5
CCT Data Multiplier
4000K 0.995
300W 5000K
Input Voltage (VAC) 120-277 277-480
System Level Power (W) 305
Delivered Lumens (Lm) 42266 42243
System Ecacy (Lm/W) 139 139
Correlated Color Temp (K)
Color Rendering Index (CRI) 86
Beam Angle (0) 88.9
Beam Angle (90)
Spacing Criteria (0) 1.28
Spacing Criteria (90) 1.26
5000
90.6
14053
10539
7026
3529
20410
15307
10205
5125
Cone of Light Tabulation
Mounted height
(Feet)
23 41.4 45.3 25 35.0 49.2 28 27.8 55.1 30 24.2 59.1 32 21.1 63.0
Footcandles
Beam Center
Cone of Light Tabulation
Mounted height
(Feet)
23 60.1 45.3 25 50.8 49.2 28 40.4 55.1 30 35.2 59.1 32 30.7 63.0
Footcandles
Beam Center
Diameter
(Feet)
Diameter
(Feet)
CCT Data Multiplier
4000K 0.995
32279
450W 5000K
Input Voltage (VAC) 120-277 277-480
System Level Power (W) 459
Delivered Lumens (Lm) 66850 66783
System Ecacy (Lm/W) 145 145
Correlated Color Temp (K)
Color Rendering Index (CRI) 86
Beam Angle (0) 88.9
Beam Angle (90)
Spacing Criteria (0) 1.28
Spacing Criteria (90) 1.26
5000
90.6
CCT Data Multiplier
4000K 0.995
Fixture tested per LM-79-08. Photometric data is of the performance of a representative xture. Results may vary in the eld.
24208
16105
8071
Cone of Light Tabulation
Mounted height
(Feet)
23 60.1 45.3 25 50.8 49.2 28 40.4 55.1 30 35.2 59.1 32 30.7 63.0
Footcandles
Beam Center
Diameter
(Feet)
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 5 of 7
Page 6
HML1
LED High-Performance High Bay
Dimmers and Sensors
Recommended Dimmers*
Lutron NTSTV Lutron DVSTV Cooper SF10P
Legrand RH4FBL3PW
*Not a complete list. Check compatibility before installation.
Any “S” (sensor socket) model can be converted to use with NICOR LIghting Controls (NLC) by installing the NLC sensor. For more information please see the information and spec sheets for the NLC system.
On “S” (sensor socket) models, there is an additional 12VDC output on the driver. This output can be used to provide power to external low voltage sensors or controls. Do not use the 12VDC output if a sensor is installed in the socket.
NICOR Lighting Controls (NLC)
12VDC Output
Microwave Motion Sensor (H12VSENSORMW)
See the individual spec sheet for further information
• Field installed 12VDC sensor
• Microwave motion detector with built in daylight sensor
• Remote control programmable
• Highly congurable:
• Detection area
• Hold time
• Dimming level
• Stand-by period
• Stand-by dimming
• Daylight harvesting threshold
• Max mounting height: 40ft (12m)
• IP65 Rated
2.2 in (55mm)
0.8 in(20mm)
Passive Infrared (PIR) Motion Sensor
See the individual spec sheet for further information
• Field installed 12VDC sensor
• Microwave motion detector with built in daylight sensor
• Remote control programmable
• Highly congurable:
• Detection area
• Hold time
• Dimming level
• Stand-by period
• Stand-by dimming
• Daylight harvesting threshold
• Max mounting height: 40ft (12m)
• IP65 Rated
Remote Control for Sensors (H12VREMOTE)
See the individual spec sheet for further information
• Allows programming of MW or PIR sensors
• Allows adjustment of:
• Brightness
• Hold time
• Stand-by dim level
• Stand-by time
• Sensor sensitivity
• Daylight harvesting threshold
2.2 in (55mm)
1.3 in(34mm)
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 6 of 7
Page 7
HML1
LED High-Performance High Bay
Dimensions
L
Length: 14.1 in. (360mm) 28.3 in (720mm) 42.5 in. (1080mm)
Width: 10.1 in. (260mm)
W
Height: 1.9 in. (49mm)
Product Measurements
100W-150W 210W, 300W 450W
H
L
W
L
W
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com June 30, 2022 1:27 PM rev 2.0 HML1 Page 7 of 7
Loading...