Nicopure Labs Reactor User Manual

REACTOR
80W BATTERY (TC)
INTRODUCTION
Thank you for purchasing the REACTOR battery. Please read this manual carefully before using to ensure optimal lifespan and performance.
GETTING STARTED GETTING STARTED
It is important to turn “o” this device before storing.
There is no harm in leaving your REACTOR battery “on,” as the battery life will not be consumed unless the ring button is pressed. It is important however, to turn your battery “o” when placing it in drawers, pockets, or purses to ensure the button is not pressed inadvertently.
To turn the REACTOR battery “o,” follow the same steps used to turn the battery “on.” Simply press the ring button ve times in rapid succession, and the LED screen will go blank. Please note, you will need to turn the REACTOR battery back “on” again before using.
REACTOR batteries must be turned “on” before using for the rst time.
To turn on your REACTOR, press the ring button on the side of the battery ve times in rapid succession. Once the battery is turned on, the digital LED screen will become visible. To use this device, rst ensure the battery is “on” and the tank is lled with e-liquid. Once ready, place your lips around the mouthpiece and inhale while holding down the ring button. Release the button at the end of each drag and repeat as desired. The wattage can be adjusted to personal preference as described later in this instruction manual.
REACTOR 80w
COMPONENT’S FRONT & BOTTOMCOMPONENT’S SIDE
FRONT VIEW
BOTTOM VIEW
FIRING BUTTON
OLED SCREEN
• Battery Indicator
• Resistance Level
• Wattage
• Voltage
• Temperature
• Coil Type
FIRING BUTTON
OLED SCREEN
UP/ DOWN
ADJUSTMENT
MENU
BUTTON
MENU
BUTTON
USB
CHARGING
PORT
POWER ADJUSTMENT
Overview Adjusting the power (wattage) of your REACTOR battery oers the ability to customize your vaping experience. Flavors taste better at dierent power levels, so the ability to adjust wattage allows users to nd the “sweet spot” of their favorite e-liquids. Increased power will generate increased heat, which typically results in warmer, more plentiful vapor production.
Adjusting Power The wattage can be adjusted by pressing the “up” or “down” power adjustment buttons until the desired level is reached. An increase in wattage will translate to an increase in power. It is recommended to start with lower levels and slowly increase the wattage.
POWER ADJUSTMENT
Advanced Users Advanced users can further customize their vaping experience by using coil heads of varying resistance. The resistance of the attached coil head (ohms) can be viewed next to the battery level indicator. Lower resistance coils will increase the power.
Locking the Wattage
Once a preferred wattage level is found, the device can be locked to ensure the arrow buttons are not pressed accidentally. To lock the wattage, press the up arrow and the down arrow simultaneously for two seconds. Once successful, the LED screen will display the word “Lock.” To unlock the device, repeat the process until the LED screen displays the word “Unlock.”
TEMPERATURE CONTROL
TC Overview
The REACTOR battery oers advanced temperature control (TC) functionality, allowing users to set a maximum coil temperature. This is often used to maintain a consistent avor prole while preventing “dry hits.” When a TC compatible coil is attached to the battery, the corresponding mode must be selected for the functionality to work properly. NI200 and Titanium coils should never be used in Variable Wattage Mode or red for extended periods of time.
The chart to the right indicates the available modes and corresponding coil types required.
Mode Coil Material Temp Con trol
VW Any (Kanthal) No
TC-Ni NI200 Yes
TC-Ti Titanium Yes
TC-SS 316L Stainless Steel Yes
TCR -M1 Advanced Memory 1 Yes
TCR-M2 Advanced Memory 2 Yes
TCR-M3 Advanced Memory 3 Yes
TEMPERATURE CONTROL
TEMPERATURE CONTROL
TC Modes
To use the temperature control functionality, rst ensure a TC compatible coil from the list on the last page is attached to the device. Next, press and hold the “menu” button to toggle between available modes. Release the button when the desired mode is visible on the screen. The device can also be manually set to run without temperature control by selecting the variable wattage (VW) mode, bypass mode or smart mode. In variable wattage mode, only overall power can be adjusted without the ability to limit the maximum temperature. When setting the maximum temperature of the coil, it is highly recommended to start low and slowly increase the temperature. In bypass mode, the device can support a coil with
TEMPERATURE CONTROL
a resistance level within the range of 0.1 ohms - 3.5 ohms. Direct voltage output system is applied in this mode. Therefore, the higher the battery level, the higher the voltage output. In Smart Mode, the wattage can be adjusted from 1W to 80W by pressing the up button or down button only when an atomizer is installed on the device. The Smart Mode will save one output power setting for each resistance value and can totally save 10 groups of such proles. Once you change the output power setting for a resistance, it will resave the changed setting automatically. When the Smart Mode has already remem bered 10 proles and you want to add anothe r new resistance, the rs t saved prole w ill be delete d. When set in this mode, the device can support a coil whose resistance is within the range of 0.1-3.5 ohms.
TEMPERATURE CONTROL
Note: When using a non-TC coil in one of the temperature control modes by mistake, the device will automatically switch to variable wattage (VW) mode.
Adjusting Wattage
When in a temperature control mode, the wattage output can be adjusted from 1W - 80W. Keep pressing the “menu” button and the up button simultaneously to increase the wattage level. To decrease the wattage level, simultaneously press the “menu” button and the down button.
Adjusting Temperature
When in a temperature control mode, the maximum coil
TEMPERATURE CONTROL
temperature can be adjusted from 200-600°F by pressing the up button to increase and down button to decrease. Each press of the up or down button will increase or decrease the temperature setting by 10°F. Holding the up or down button will rapidly increase or decrease the temperature.
Shift Between °C and °F
If you increase temperature to 315 °C and continue to press the up button, the temperature reading will automatically change to the lowest Fahrenheit (200°F). Equally, if the temperature is set at the lowest Fahrenheit (200°F) and you continue to press the down button, the temperature reading will automatically change to the highest Celsius (315°C).
TEMPERATURE CONTROL TEMPERATURE CONTROL
TCR Mode Advanced
TCR (Temperature Coecient of Resistance) mode allows the user to manually adjust the TCR values for dierent types of wire to further improve on the accuracy of the device’s ability to limit and sense an atomizer coil’s temperature. There are three storage slots available (M1,M2,M3), each of which can store a
user dened TCR value. For your reference, the following table indicates standard TCR value ranges for dierent wire types:
Material Nickel Titanium NiFe SS (303,304,316,317)
TCR Value Range 600-700 300-400 300-400 80 -200
Note: The TCR values listed above are 10X the actual Temperature Coecient of Resistance.
M1 MODE VIEW
TEMPERATURE CONTROL TEMPERATURE CONTROL
Resistance Locking
Resistance Lock Mode allows the device to maintain the same “base resistance” even though the coil resistance may increase due to a rise in temperature. When locked, the device will remember the last resistance used after a coil is removed and then put back on.
In Resistance Unlock Mode, the resistance will be checked each time a new coil is attached. After removing a coil, the screen will display “New coil up same down” to check if the same coil is being re-attached. If the same coil is being re-attached, press the down button and if it is a new coil, press the up button.
Lock/Unlock Resistance
To lock or unlock the base resistance, ensure the device is turned on and is set to one of the temperature control modes (TC-Ni/ TC-Ti/TC-SS/TCR M1, M2, M3). The attached coil must be at room temperature for the device to correctly set the “base resistance.” Next, hold down the re button and up button simultaneously for 2 seconds to lock or unlock the resistance. The lock sign will appear when resistance is locked and “Ω” symbol will come back when unlocked.
Note: Be sure to unlock the base resistance when you want to change an atomizer or a coil to a dierent resistance.
BATTERY FEATURES
Switching LED Orientation:
The LED display can be rotated 180° based on user preference. With the REACTOR battery turned “o,” press the “up” arrow and the “down” arrow simultaneously for two seconds.
Overheat Protection
The REACTOR battery is equipped with overheat protection which will automatically deactivate the device should its temperature rise above 158° Fahrenheit (70° Celsius). If a temperature above 158°F is detected, the REACTOR battery will lock and the LED screen will display “temp protection” for the next ve seconds. After this time, the device will unlock, the display will return to normal, and you may resume vaping.
BATTERY FEATURES
Short Circuit Protection
The REACTOR is equipped with short circuit protection to ensure your battery is not damaged by faulty tanks/coils. Should a short circuit occur in the tank, the unit will not re, and the LED screen will display “atomizer short.” Replace the coil head in the tank, and your REACTOR battery will perform again as intended.
Drag Time
Once the REACTOR ring button is pressed, the time elapsed (in seconds) is displayed on the LED screen. The total drag length will be visible for three seconds after the ring button is released. This allows the user to track the length of each drag.
BATTERY CHARGING
When to Recharge As you use the REACTOR, the battery will slowly drain and eventually need to be recharged. The battery level indicator on the LED screen will display the amount of battery life remaining. The battery can be charged at any time, regardless of the remaining charge. If the battery is completely drained, it will need to be charged before continuing use.
Important Note:
It’s important to use only the REACTOR USB cable and wall charger. Using components from other manufacturers may cause irreversible damage to your REACTOR battery and increase the risk of re due to potential voltage dierences.
BATTERY CHARGING
Charging Time The REACTOR battery will typically take 6.5 hours to obtain a full charge from its fully drained state.
How to Recharge
Attach the small connector of the USB cable into the charging port of the REACTOR battery. The larger end of the cable should then be inserted into a computer or other USB compatible power source, or can be used in conjunction with the REACTOR wall charger. Once connected to a power source, the battery level indicator on the LED screen will ash until fully charged. Once fully charged, the battery level indicator will stop blinking, shine for 10 seconds and go out.
WARNINGS
Storage: This device should be kept out of reach of children and pets, and stored safely in a dry environment. Do not store in high-temperature areas, as this will cause irreversible damage to batteries and other components.
Overheating: If the REACTOR vaporizes continuously or shows any signs of overheating, stop usage immediately and unscrew all parts.
Charging: Do not use the charger in damp areas or near a high temperature heat source. If the power supply emits any heat or odor, is discolored, or experiences any unexpected issues while charging, unplug it immediately.
WARNINGS
Coil Resistance: The REACTOR battery is designed to work with coils having a resistance of .1 ohms or above. Using coil heads below .1 ohms will create a potentially unsafe situation.
Improper Usage: The use of any third-party accessories may lead to malfunction and/or damage of this product.
Guarantee: The REACTOR oers a 30 -day satisfac tion guarante e on all hardware. However, e-liquids and coil assemblies are consumable items and will not be refunded.
Warranty: Claims for products damaged by improper usage will not be accepted. This includes, but is not limited to, the use of third-party hardware and/or improper handling.
110465
Nicopure Labs, LLC.
5909 NW 18th Drive, Gainesville, FL 32653
nicopure.com
Loading...