Nicol Scales & Measurement CPS, CPS-1, CPS-2 Owner's Manual

Page 1
Presented By
Dallas HoustonAustinFt Worth
NicolScales.com
800.225.8181
Contact Us
Nicol Scales & Measurement is an ISO Accredited Calibration
Company that has provided calibration, repair and sales of all types
of weighing and measurement products since 1931.
Page 2
PALLET SCALE
CPS SERIES
OWNER'S MANUAL
Page 3
Pallet Scale
Table of Contents
1. PREFACE 3
2. OVERALL VIEW 4
3. SPECIFICATIONS 5
4. DIMENSIONS 5
5. FRONT PANEL 6
6. RS-232C (OPTION) 8
7. OPERATIONS 10
8. HOW TO CHARGE 12
9. TEST MODE 13
10. SET MODE 14
11. ERROR MESSAGE AND TROUBLE SHOOTING 19
Page 4
Pallet Scale
1. PREFACE
Thank you for the purchasing of our CAS CPS Series. These series have been designed with CAS reliability, under rigid quality control and with outstanding performances. Your speciality departments can enjoy with these high quality reliable CAS products. These electronic load cell scales eliminate the all the moving parts and furnish an accurate digital display of all i nformation. We believe that your needs will be satisfied and you will have proper reliability in variable weight. This manual will help y ou with proper operations and care of the CPS scales. Please keep it handy for the future references.
CAUTIONS
Do not press the keys hardly, for the keys are in operation with soft touch. Do not use ignitable material for cleaning. Keep away CI-2001B from the rain. Avoid sudden temperature change. Do not install CI-2001B in a place with high voltage and excessive electrical noises. Keep it in dry place. Do not use under direct rays and dusty place. Do not use at the place with excessive electrical noises and vibration.
FEATURES
CAS PALLET SCALE (CPS) weigh the pallet loads with accuracy. CPS's "lift and read" technology speed the loading and weighing process. We have 1000kg and 2000kg capacity models. Digital indicator displays the weight. Built-in printer(optional). You can record the weight of loads with printer. Built-in battery. You can use this scale without power outlet.
NOTICE : Specifications are subject to change for improvement without notice.
Page 5
Pallet Scale
2. OVERALL VIEW
Page 6
Pallet Scale
3. SPECIFICATIONS
MODEL NAME CPS-1 CPS-2
SIZE
TYPE A B C A B C
W 540 620 705 540 620 705
L 1080 1080 1200 1080 1080 1200
CAPACITY 1000 ×0.5 (2000lb×1lb)㎏㎏ 2000 ×1 (5000lb×2lb)㎏㎏
OVERLOAD PROTECTION
1500 (3000lb) 2500 (5500lb)
WEIGHT DISPLAY
5digit LCD (HEIGHT 25mm)
POWER SUPPLY DC6V/ 10AH BATTERY (AC 110V/220V CHARGER)
ACCURACY 0.1%
OPTION PRINTER, PC Connection
TEMPERATURE RANGE -10 ~ 40℃℃
4. DIMENSIONS
Page 7
Pallet Scale
5. FRONT PANEL
kg version.
kg/lb version.
(1) Display lamp
lb lamp : ON when the weight unit is pound. [lb] kg lamp : ON when the weight unit is kilogram. [kg]
lamp : ON when the weight is stable.□○ ZERO lamp : ON when the current weight is 0 kg. (0 lb). NET lamp : ON when the current weight is NET weight. BAT lamp : In case of rechargeable battery, display the battery
recharging time.
Battery warning lamp
If Battery warning lamp turn on, CPS will power off after about 30 seconds.
Page 8
Pallet Scale
(2) Keyboard
,Key□▲ ◀
Available keys instead of numeric keys.
: Change the set value
Increase the first place value to 1
: Change the digit of the set value
Move to the left by 1 place
USAGE : Input the numeral value in TEST, SET mode.
ZERO Key : Return the display to 0.
TARE Key
Use container in weighing. Current weight is memorized as tare weight. If you press TARE key in unload condition, Tare setting is released.
GROSS/NET Key
Display gross and net weight by turn. GROSS lamp on - gross weight NET lamp on - net weight In case tare weight is REGISTERED, tare and item's total weight is G. weight and only item's weight is N. weight.
kg/lb Key (Only kg/lb version)
Toggles between lb and kg units.
PRINT Key
1. PRINT Key : Total Print key (by pressing "PRINT" key more than 3 second.)
2. HOLD Key
* key(Only kg version)
1. Total print key. (F09 - 1)
2. Hold key. (F09 - 2)
ON/OFF Key
1. Back light ON/OFF key
2. ON/OFF key (by pressing key more than 3 second.)
3. Store current condition and exit in TEST, SET mode.
Page 9
Pallet Scale
6. RS-232C (OPTION)
(1) How to RS-232C Select switch
(2) How to connect PC
Connect the serial port on the rear panel of the indicator to serial port of PC as follows.
9 pin port(Male) 25 pin port(Female) RS-232C port of CPS Series Serial port of computer
RXD 3 ------------------------------------ 2 Transmit Data
TXD 2 ------------------------------------ 3Receive Data
GND 7 ------------------------------------ 7 Signal Ground
┏━ 8 Carrier Detect ┣━ 20 Data Terminal Ready ┣━ 6 Data Set Ready ┣━ 4 Request to Send ┗━ 5 Clear to Send
Page 10
Pallet Scale
9 pin port(Male) 9 pin port(Female) RS-232C port of CPS Series Serial port of computer
(3) How to connect Sub display
9 pin port(Male) 9 pin port(Female) RS-232C port of CPS Series Serial port of computer
(4) Data format
Baud rate : 1200 bps - 19200 bps
Set Baud rate in SET mode. (See F20 at page 30)
Data bit: 8, Stop bit: 1,Parity bit: None Code : ASCII When data is sent to computer? : Set in SET mode(See F12 at page 31). Format
┗━┛ ┗━┛ ┗┓┗━━┓ ┗━┛
US(Unstable) GS(GROSS weight) Device ID Lamp condition byte Empty Unit (kg/t) ST(Stable) NT(NET weight) OL(Overload)
RXD 3 ------------------------------------ 3 Transmit Data
TXD 2 ------------------------------------ 2Receive Data
GND 7 ------------------------------------ 5 Signal Ground
┏━ 1 Carrier Detect ┣━ 4 Data Terminal Ready ┣━ 6 Data Set Ready ┣━ 7 Request to Send ┗━ 8 Clear to Send
, , , DATA (8 byte) CR LF
RXD 3 ------------------------------------ 2ㅇ Transmit Data
TXD 2 ------------------------------------ 3ㅇ Receive Data
GND 7 ------------------------------------ 7ㅇ Signal Ground
Page 11
Pallet Scale
- Device ID : Transmit 1 byte so that the receiver can receive data selectively which indicator sent.(Device ID is selected in F10 .
- Weight Data (8 byte)
a. 13.5: ' ', ' ', ' ', ' ', '1', '3', '.', '5' b. 135: ' ', ' ', ' ', ' ', '1', '3', '5', ' ' c. -135: '-', ' ', ' ', ' ', '1', '3', '5', ' '
6. OPERATIONS
(1) How to assembly
Page 12
Pallet Scale
(2) Operations
1. Turn the power switch ON. The power switch is located on the right side of the indicator.
WARNING
: Avoid leaving ANY load before turn the power switch ON.
2. Pressing ON key of front panel.
3. Display will show “0”, make sure that ZERO lamp is ON.
4. When the FORK lift the load, weighing is performed.
WARNING
: Fork have to properly level so as to center bubble of the
leveling gauge inside the indicated circle and fork truck should not move.
5. If you want to adjust zero range, press the ZERO key.
6. If you want to use tare function, press the TARE key. If you don't want to use tare function any more, remove the container(pallet) and press the TARE key.
7. If you want to down the fork, pull the DOWN LEVER. If you w ant to lift the fork, press the STOPPER and operate the LIFT HANDLE.
Page 13
Pallet Scale
8. HOW TO CHARGE
1. Plug the charger into a AC socket and make sure that the socket's power is within the charger's operating range.
Open the socket's cover located on the right side of indicator and then
connect to the connector. (See Fig 1.)
2. Depending on the charging state, the lamp located on the charger will be ON.
3. When the battery is fully charged, the charger lamp will be ON.
4. It takes about 8 hours to fully charge the battery.
(Fig 1)
Page 14
Pallet Scale
9. TEST MODE
(1) HOW TO ENTER
Turn on the power while pressing the 'ZERO' key and TEST menu starts.
(2) AVAILABLE KEYS & CONVERTING METHOD
KEY : Increase the first place set value to 1
KEY : Move to the left by 1 place of the set value. PRINT(kg/lb version) or *(kg version)KEY : Move to a weight measure mode ON/OFF KEY : Move into next menu.
(3) TEST MENU(TEST1 - TEST 5) TEST 1 : Key test TEST 2 : LCD display test TEST 3 : Load cell test and A/D conversion test TEST 5 : Print test
TEST 1
<Key code>
Page 15
Pallet Scale
TEST 2
Ref 1. Program is automatically shifted to menu selection mode after completing.
TEST 3
Ref 1. Check whether digital value is changing. If the digital value is fixed or
zero is displayed. Please check the connection of the load cell.
TEST 5
Ref 1. "Good" message is displayed if the printer connection and
specification is done correctly. if not, "Err 06" message is displayed.
Ref 2. The test output format of printer is like follows.
TEST OK
Page 16
Pallet Scale
10. SET MODE
(1) HOW TO ENTER
Turn on the power while pressing the "TARE" key and SET menu starts.
(2) AVAILABLE KEYS & CONVERTING METHOD
KEY : Increase the first place set value to 1
KEY : Move to the left by 1 place of the set value. PRINT(kg/lb version)KEY, *(kg version)KEY : Move to a weight measure mode ON/OFF KEY : Move into next menu.
(3) SET VALUE CONVERSION MENU (F01 - F18) F01:Selecttheprimary base unit (kg/lb) F02 : Designation of serial port usage F03:Automaticzeroconditionset F04 : Digital Filter F07:WeightBack-up(Power-onActualWeight) F08 : "PRINT" Key Usage F10 : Device ID F11 : Designation of Serial Interface Baud rate F12 : Designation of Serial Interface output mode F13 : Set HOLD type F14 : Select of clock option F17 : Print line feed F18 : Display mode
Page 17
Pallet Scale
Select the primary base unit (Only kg/lb version)
F01
0
primary unit is kg
1
primary unit is lb
Serial port usage
F02
0
Not Usage
1
Connection to serial Printer
Automatic Zero tracking
F03
0
None Automatic zero
1 ~ 9
0.5 digit . .
4.5 digit
Auto zero tracking will automatically bring the display back to "0" when there are small deviations.
Digital Filter
F04
0
None Digital filter
Adjustthesetvalueaccordingtothe condition.
1 ~ 9
1 : Less Vibration
. .
9 : Much Vibration
Select the weight back-up mode
F07
0
Weight back-up is off (Power on Zero)
1
Weight back-up is on
"PRINT" Key Usage (Only kg/lb version)
F08
0
Not used
1
-Printkey
- Total Print key (by pressing "PRINT" key more than 3 second)
2
HOLD Key
Page 18
Pallet Scale
" * " Key Usage (Only kg version)
F09
0
Not used
1
Total Print key
2
HOLD Key
Device ID
F10
00
~
99
Device ID "00"
. .
Device ID "99"
It is used the no. of indicator when system is connected.
Baud Rate
F11
0
600 bps
1
1200 bps
2
2400 bps
3
4800 bps
4
9600 bps
5
19200 bps
Output Mode
F12
0
No data output
1
Stream Mode
2
Transmit only in stable condition
3
Transmit when data is required Request signal : device ID (F10 : Device ID) (IncaseF10:1,SendHexValue01hinComputer)
Set HOLD type
F13
0
Average hold : Compute the average weight of oscillating weights.
1
Peak hold : Compute the maximum weight among oscillating weights.
2
Sampling hold : Compute the current weight.
Page 19
Pallet Scale
Select Option Clock
F14
0
Not use Clock
1
Use Clock
Change Date/Time ( Ex. 1998/12/11 13:10:01)
: Increase of no.
: Shift of digit
LIGHT : Store and
move into next menu
LCDisplay Meaning
C1 98
Year : 98
C2 12
Month : 12
C3 11
Day : 11
C4 13
Hour : 13
C5 10
Minute : 10
C6 01
Second : 01
Print line feed
F17
1
1Linefeed
2
2Linefeed
3
3Linefeed
4
4Linefeed
5
5Linefeed
Display mode
F18
0
Always display weight in Normal.
1
When stable, display weight in Normal.
Page 20
Pallet Scale
11. Error message & Troubleshooting
Err 01
Reason The weight is too unstable to initialize the scale. Troubleshooting Laythescaleonaplatplaceandturnonthepower.
Err 02
Reason Load cell connection failure or error in A/D conversion part. Troubleshooting Check the load cell connector to see if the polarity of signal is reversed.
Err 06
Reason Error in printer connection Troubleshooting Check with printer connector If there is no problem with printer and printer connector, please request A/S to head office.
Err 08
Reason The ZERO key or TARE key is adjusted not to be operated under the unstable condition. Troubleshooting Press Zero or Tare key in stable condition
Err 09
Reason Current weight deviates from zero range. Troubleshooting Press the ZERO key within 10% of the maximum capacity.
Page 21
Pallet Scale
Err 10
Reason Tare weight exceeds the maximum capacity of the scale. Troubleshooting Set the tare to be smaller than the maximum capacity. Otherwise the maximum capacity is reset to be larger than the tare to be
set in the calibration menu, and reset the calibration using weight.
Err 13
Reason The zero range deviates from the set range. Troubleshooting Confirm that there is nothing on the weighing platform. If nothing exist, do calibration in CAL mode.
Over
Reason The weight on platform is too heavy to be measured. Troubleshooting Do not load the item exceeds the maximum tolerance. If the load cell is damaged, the load cell should be replace.