Nicol Scales & Measurement AP-US Owner's Manual

Page 1
Presented By
Dallas HoustonAustinFt Worth
NicolScales.com
800.225.8181
Contact Us
Nicol Scales & Measurement is an ISO Accredited Calibration
Company that has provided calibration, repair and sales of all types
of weighing and measurement products since 1931.
Page 2
AP-US
(
lb version
)
Price Computing Scale
OWNER’S MANUAL
Page 3
CONTENTS
PRECAUTIONS 4 PREFACE 6 INSTALLATIONS 6 NAMES AND FUNCTIONS 7 OPERATIONS 9
1. General Weighing 9
2. Pricing 1/2 Key 9
3. Pricing 1/4 Key 10
4. Weighing with T ar e 10
5. Saving a Current Tare W eight and Unit Price 12
6. Saving a Unit PLU to Memory 12
7. How to Call a PLU 14
8. How to Print 15
ERROR MESSAGE 17 SPECIFICATIONS 17
Page 4
4
5
PRECAUTIONS
Precautions when in stalling the scale. To ensure that you get the most from your scale, please follow these instruction.
The socket-outlet shall be installed near the equipment and shall be easily accessible.
Do not disassemble the scale. When any damage or defect occurs, contact your CAS authorized dealer immediately for proper repair.
Do not overload beyond the maximum weight limit.
Do not pull the plug by its cord when unplugging. Damaged cord could cause electric shock or fire.
To prevent from fire occurring, Do not place or use the scale near flammable or corrosive gas.
Avoid placing the scale near heater or in direct sunlight.
Scale must be grounded to minimize electricity static. This will minimize defect or electric shock.
Insert plug firmly to wall outlet to prevent electric shock.
To reduce electric shock or incorrect reading, Do not spill water on the scale or place it in humid condition.
Warning
For consistent and accurate reading, maintain periodical check by your CAS authorized dealer.
Avoid sudden shock to the scale. Internal mechanism could be damaged.
Place the scale on firm and temperature consistent environment.
Keep the scale away from other electromagnetic generating devices. This may interfere with accurate reading.
Grab on the bottom of the scale when moving. Do not hold by the platter.
By adjusting 4 corners of the scale, set the scale even using the built in scale leveling indicator.
Attention
Page 5
7
6
PREFACE
INSTALLATIONS
Thank you for the purchasing of our CAS AP Series. These series have been designed with CAS reliability, under rigid quality control and with outstanding performances. Your speciality departments can enjoy with these high quality reliable CAS products. We believe that your needs will be satisfied and you will have proper reliability in variable weight. This manual will help you with proper operations and take care of the AP series. Please keep it handy for the future references.
1. Loosen the twist lock nut on the display pole as fig. 1.
2. Pull the harness wire as fig. 2.
3. Turn the post pipe 180
and insert the projections of post pipe into the
holes on the bracket as fig. 3
4. Insert and fasten display assembly screws as fig. 1
5. Tighten the twist lock nut on the display pole as fig.4
fig. 1
fig. 2
fig. 3
fig. 4
NAMES AND FUNCTIONS
OVERALL VIEW
Display
Post Pipe
Post Pipe
Bracket
Screw
Hole
180
Projecton
Twist lock
nut
Post Bracket
Adjusting Bolt
Keyboard
Power Plug
Platter
Leveling
Gauge
Body
1
23
4
5
6
0
ON OFF
00
C
ZERO
7
89
TARE
*
MR
1 / 2 1 / 4
MW
TOTAL PRICE
WEIGHT
UNIT PRICE
lb
$
$ / lb
NETZERO
SAVE
CAPACITY
0~30 lb x 0.01 lb / 30 ~ 60 lb X 0.02 lb
SAVE
PRINT
DISPLAY & KEYBOARD
Page 6
9
8
KEY FUNCTIONS
~
0
00
9
C
TARE
1 / 2
1 / 4
ZERO
MR
MW
PRINT
SAVE
Used to enter all the numerical data.
Used to enter a double zeros.
Used to clear all the numerics dn the unit price display. Used to clear sum total price.
Used to correct the zero point.
Used to enter a tare weight. Used to delete a tare weight.
This key allows the sale of items by unit price per half pound.
This key allows the sale of items by unit price per quarter pound.
Used to store PLU(price look up) to memory up to 499 items.
Used to call PLU(price look up) in memory up to 499 items.
Used to saves a current tare and currently called unit price from automatically.
Enable or Disable Auto-printing funtion.
Direct PLU keys.
KEYS FUNCTIONS
OPERATIONS
When you turn on the power, the scale will count “99999” to “00000”. Then the scale will read “0.000” in the weight display. This is called the ZERO state. If the scale is not ZERO state though there is nothing on the platter, press the ZERO key.
The display indicates if the scale is at ZERO or if there is a TARE entered into the scale by way of a ZERO and NET lamps.
1. General Weighing
1 2 7 5
Enter a unit price. Place the commodity on
the platter.
Remove the commodity from the platter.
NOTE : The unit price is cleared automatically after each weighing
2. Pricing : 1/2 Key
1/2
1 00
Enter a unit price. Press the 1/2 key
This function doubles the price per pound.
Page 7
10
11
TARE
2 9
9
Place the container on the platter.
Press the TARE key. Enter a unit price.
4. WEIGHING WITH THE TARE
A) Unknown (weighed) tare
Place the commodity on the platter.
Remove the commodity from the platter.
3. Pricing : 1/4 Key
1/4
1 00
TARE
Enter a unit price. Press the 1/4 key
This function quadruples the price per pound.
Enter tare weight by pressing the numeric key.
Press TARE key.
B) Known (manually entered) tare
Place the container on the platter and enter a unit price.
Place the commodity in the container.
Remove commodity with container from the platter. If you want to save tare weight and unit price, press the SAVE key.
NOTE:The tare is cleared automatically after each transaction.
Page 8
12
13
MW
Press the MW key.
MW
3 7 5
Enter a unit price.
Press the MW key.
Enter a desired address of the PLU. (0 To 199)
B) For Indirect PLUs
Enter a unit price. Press the MW key. Press one of the PLU keys.
6. SAVING A PLU TO MEMORY
The function saves each PLU into a internal back up memories. The PLU means Price Look Up which has an unit price.
AP-EX has 28direct PLUs and 200 indirect PLUs. AP-MX has 5direct PLUs and 200 indirect PLUs. AP-SM has 7direct PLUs.
MW
2 9 9
A) For Direct PLUs
5. SAVING A CURRENT TARE WEIGHT AND UNIT PRICE
The function saves currently called unit price from automatically clearing.
SAVE
Press the SAVE key. Set the tare weight,1.00lb, and enter a unit price.
Place the commodity on the platter.
Remove the commodity from the platter. Then the display still shows tare weight, and unit price.
Page 9
14
15
7. How to Call a PLU
Make sure that the platter is empty before call up a PLU.
A) For Direct PLUs
Press one of the direct
PLU keys.
Place the commodity on
the platter.
Remove the commodity from the platter.
Remove the commodity from the platter.
NOTE : Decimal point of the unit price display has no meaning.
MR
Enter an address of the
indirect PLU.
Place the commodity on the platter.
B) For Indirect PLUsB) For Indirect PLUs
Press the MR key.
Press the PRINT key.
The display shows “P on”. Auto print funtion is activated.
8. How to Print
PRINT
Turn print function on.
Page 10
17
16
3 7 5
Enter a unit price. Place commodity on the
platter. and then printing is done automatically
Remove the commodity from the platter.
Do general weighing.
ERROR MESSAGES
To help for the customer’s understanding, this scale warns the error message properly. Please refer to error table.
An error of the initial zero range
A failure of the analog module
key codes are broken
set the platter empty.
Call your CAS dealer
Call your CAS dealer from calibration
ERROR MEANINGS SOLUTIONS
Display HELP 1 Display ERR 10
Long Beep
AP- 1
0~30
0.01 lb / 30~60 0.02 lb
ZERO, TARE, SAVE
-29.99 lb 10°C 40°C
AC 120V / 60 Hz
APPROX. 10W 340(W)
215(D)
435(W)
325(D) 495(H)
SPECIFICATIONS
MODEL
CAPACITY
DISPLAYS:WEIGHT
UNIT PRICE TOTAL PRICE
DISPLAY DESIGNATORS MAXIMUM TARE OPERATING TEMPERATURE POWER SOURCE POWER CONSUMPTION PLATTER SIZE (W
D)
PRODUCT SIZE (W
D H)
5 DIGIT 6 DIGIT 7 DIGIT
Example
DATE
weight unit price total No_PLU
11.40 lb @ $3.75/ lb $ 42.75 Sum($) $42.75
Page 11
18
MEMO
Loading...