EDFAB+PON 2U is a low noise high-performance Er Yb codoped fiber amplifier.
Each output built-in CWDM (1310/1490/1550) wavelength division multiplexer.
Conveniently multiplex the data stream of OLT and ONU to the fiber amplifier output
by 1310nm and 1490nm optical connector. Thus reduced the equipment quantity,
improved the system indexes and reliability. It is the ideal equipment for FTTx
network, provides a flexible and low cost solution for the integration of three
networks and the FTTH.
Adopts Er Yb Codoped double-clad fiber technology;
Output ports: 4-16 optional;
Optical output power: total output up to 5W;
Low noise figure: <5dB when input is 0dBm;
Perfect network management interface, in line with standard SNMP network
management;
Intelligent temperature control system make the power consumption lower;
3
-
3
-
-
3
-
-
-
3. Block diagram
Built-in WDM schematic diagram
4. Technique Parameter
4.1 Technique Parameter
Item Unit
CATV pass through wavelength nm 1545 - 1565
PON pass through wavelength nm
PONinsertion loss dB <0.8
Isolation db >15
CATV optical input power range dBm
Maximum optical output power dBm
4
-
4
-
4
Technique parameters
-
-
1260 - 1360
1480 - 1500
-5 - +10
36
-
-
Output power stability dBm
Noise figure dB
Return loss
Input dB ≥ 45
Output dB ≥ 45
≤ 5.0 (Optical input power 0dBm,
±0.5
λ=1550nm)
Optical Connector Type SC/APC
C/N dB ≥ 50
C/CTB dB ≥ 63
C/CSO dB ≥ 63
Test condition
according to
GT/T 184-2002.
Power supply voltage V A: AC160V - 250V(50 Hz); B: DC48V
Consumption W ≤ 70
Operating temperature range °C -10 - +42
Maximum operating relative
humidity
% Max 95% no condensation
Storage temperature range °C -30 - +70
Maximum storage relative
humidity
% Max 95% no condensation
Dimension mm 483(L)× 440(W)× 88(H)
5
-
5
-
-
5
-
-
-
4.2 Model and Power Comparison Table
Model
EDFAB+PON 2U 4x18dB 25 4 18
EDFAB+PON 2U 4x19dB 26 4 19
EDFAB+PON 2U 4x20dB 27 4 20
EDFAB+PON 2U 4x21dB 28 4 21
EDFAB+PON 2U 4x22dB 29 4 22
EDFAB+PON 2U 4x23dB 30 4 23
EDFAB+PON 2U 4x24dB 31 4 24
EDFAB+PON 2U 8x15dB 26 8 15
EDFAB+PON 2U 8x16dB 27 8 16
EDFAB+PON 2U 8x17dB 28 8 17
EDFAB+PON 2U 8x18dB 29 8 18
EDFAB+PON 2U 8x19dB 30 8 19
EDFAB+PON 2U 8x20dB 31 8 20
EDFAB+PON 2U 8x21dB 32 8 21
EDFAB+PON 2U 8x22dB 33 8 22
EDFAB+PON 2U 8x23dB 34 8 23
*EDFAB+PON 2U 8x24dB 35 8 24
EDFAB+PON 2U 16x15dB 29 16 15
EDFAB+PON 2U 16x16dB 30 16 16
EDFAB+PON 2U 16x17dB 31 16 17
EDFAB+PON 2U 16x18dB 32 16 18
EDFAB+PON 2U 16x19dB 33 16 19
EDFAB+PON 2U 16x20dB 34 16 20
*EDFAB+PON 2U 16x21dB 35 16 21
The models with “*” are ultra high power output EDFA.
Total output
power dBm
Output ports
number
Output power per
port dBm
6
-
6
-
-
6
-
-
-
5. External Function Description
5.1 Front Panel Description
Schematic diagram of the front panel
1) Power indicator: One switching power supply is working – yellow; two switching
power supplies are working – green.
2) Optical input power indicator:This light turns on when the optical input power is
> -10dBm.
3) Pump working status indicator: Red light means the pump is not working, but the
machine parameters are normal; flashing red light means the machine has broken
down, related fault reason see th e alarm menu of the display menu; green light
means the pump is working no rmal.
4) Optical output power indicator: This light turns on when the optical output power
is > +10dBm.
5) 160×32 dot-matrix LCD s creen: used to display all the parameters of the
machine.
6) Display the exit or cancel key of the setup menu.
7) Display the up or increase key of the setup menu.
8) Display the down or decrease key of the setup menu.
9) Display the enter key of the setup menu.
10) 1310&1490nm signal in/out (PON port).
11) Optical signal input: The default connector type is SC/APC. Other specification
requirements are specified by the customer.
12) Pump laser switching key: used to control the working status of pump laser.
“ON” means the pump laser is open and “OFF” means the pump laser is closed.
Ensure the key is on “OFF” position before power on. After passing self -test,
rotate the key to “ON” position according to the displayed message.
13) Public port (COM port): This interface is the 1550nm signal output port of the
device, also is the 1310&1490nm signal in/out port. Ports number: 4-16 optional.
Warning: There is an invisible laser beam from this port while working normal.
So the port should not be aligned to the human body or the naked eye to avoid
accidental injury.
7
-
7
-
-
7
-
-
-
5.2 Rear Panel Description
Schematic diagram of the rear panel
1) Fan outlet.
2) RS232 interface: Used for configuring the network management parameters.
3) LAN interface: correspond to IEEE802.3 10Base-T, used for network management.
4) The AC 220V inpu t port o f power supply 1.
5) The fuse of power supply 1.
6) The switch of power supply 1.
7) The AC 220V inpu t port o f power supply 2.
8) The fuse of power supply 2.
9) The switch of power supply 2.
10) Ground stud of the chassis: used for the connection of device and ground wire.
1.Disp Parameters Entry of parameter d isplay menu
2.Set Parameters Entry of parameter setup menu
3.Alarm Status Entry of alarm information menu
Display the optical input / output power
9
-
9
-
-
9
-
-
-
6.2 Display Menu
1.Disp Parameters
Input Power: xx.x dBm Input power, accurate to 0.1 dBm
Output Power: xx.x dBm Output power,accurate to 0.1 dBm
Pump1 Power: xx .x mW Power of pump1, accurate to 0.1 dBm
Pump1 Bias: x. x A Bias current of pump1, accurate to 0.1 A
Pump1 Temper: x x.x℃
Pump1 Cooling: x.xx A C ooling current of pump1, accurate to 0.01 A
Pump2 Vol: x.x V Drive voltage of pump2, accurate to 0.1 V
Pump2 Bias: x. x A Bias current of pump2, accurate to 0.1 A
* Pump2 Temper: xx.x ℃
* Pump2 Tec Vol: x.x V Cooling voltage of pump2, accurate to 0.1 V
* Pump2 C ooling: x.xx A Cooling current of pump2, accurate to 0.01 A
TEC Vol: x. x V The first stage voltage of pump2 cooler, 0.1 V
+5V Read: x.x V +5V power supply voltage , accurate to 0.1 V
Temperature of pump1, accurate to 0.1°C
Temperature of pump2, accurate to 0.1 °C
1
0
-
1
0
-
-
1
0
-
-
-
-5V Read: -x.x V-5Vpower supp ly voltage , accurate to 0. 1 V
Box Temper: xx.x ℃ Box temperature, accurate to 0.1 °C
S/N: xxxxxxxx Device serial number
IP Address: xxx.xxx.xxx.xxx IP address
Subnet Mask:xxx.xxx.xxx.xxx Subnet mask
Net Gateway:xxx.xxx.xxx.xxx Gateway
Mac: xxxxxxxxxxxx Physical address
Trap1 : xxx .xxx.xxx.xxxtrap1 address
Trap2 : xxx .xxx.xxx.xxx trap2 address
Software Version: Vx.xx.x.x Firmware version number
The ultra high power output EDFA no the “*” menu.
6.3 Setup Menu
Set the low optical input power alarm
Set Low Input Threshold
Set High Input Thresho ld
*Set Output ATT Set the optical output power attenuation
2.Set Para meters
Set Local IP Addr Set IP address
Set Subnet Mask Set subnet mask
Set Gateway Set gateway
Set Trap1 Address Set trap1
Set Trap2 Address Set trap2
Set Buzzer cfg Set the switch of beeper
Restore Factory config Restore the factory configuration,set
-
threshold, range -3.0~10.0dBm
Set the high optical input power alarm
threshold , range -3.0~10.0dBm
1
1
-
1
1
-
1
1
-
-
-
content as shown above
The ultra high power output EDFA no the “*” menu.
1
2
-
1
2
-
-
1
2
-
-
-
6.4 Warning menu
Input Status: xxx
Output Status: xxx
Pumpx Power:
Pumpx Bias: xxx
3.Alarm Status
Pumpx Temper:
Pumpx Tec: xxx
+5V Status: xxx
-5V Status: xxx
Device Temper:
xxx
xxx
xxx
xxx= LOLOW: Very low optical inp ut power alarm
xxx= LOW: Low optical input power alarm
xxx= HIGH: H igh optical inp ut power alarm
Xxx= HIHIGH: Very high optical input power alarm
xxx= LOLOW: Very low optical output power alarm
xxx= LOW: Low optical output power alarm
xxx= HIGH: H igh optical output power a larm
Xxx= HIHIGH: Very high optical output power alarm
xxx= LOLOW: Very low power of pump x a larm
xxx= LOW: Low power of pump x alarm
xxx= HIGH: H igh power of pump x alarm
Xxx= HIHIGH: Very high power of pump x alarm
xxx= LOLOW: Very low bias current of pump x alarm
xxx= LOW: Low bias current of pump x alarm
xxx= HIGH: H igh bias current of pump x alarm
Xxx= HIHIGH: Very high bias current of pump x alarm
xxx= LOLOW: Very low temperature of pump x alarm
xxx= LOW: Low temperature of pump x alarm
xxx= HIGH: H igh temperature of pump x alarm
Xxx= HIHIGH: Very high temperature of pump x alarm
xxx= LOLOW: Very low cooling current of pump x alarm
xxx= LOW: Low cooling current of pump x alarm
xxx= HIGH: H igh cooling current of pump x alarm
Xxx= HIHIGH:
xxx= LOLOW: Very low +5V DC power supply alarm
xxx= LOW: Low +5V DC power supply alarm
xxx= HIGH: H igh +5V DC power supply alarm
Xxx= HIHIGH: Very high +5V DC power supply alarm
xxx= LOLOW: Very low -5V DC power supply alarm
xxx= LOW: Low -5V DC power supply alarm
xxx= HIGH: H igh -5V DC power supply alarm
Xxx= HIHIGH: Very high -5V DC power supply alarm
xxx= LOLOW: Very low chassis temperature alarm
xxx= LOW: Low chassis temperature alarm
xxx= HIGH: H igh chassis temperature alarm
xxx= HIHIGH: Very high c hassis temperature alarm
Very high cooling current of pump x
alarm
1
3
-
1
3
-
-
1
3
-
-
-
7. Communication Setup Descriptions
7.1Communication Interface Description
1) RS232 communication interface
Adopt DB9 standard connector, the pin definitions as follow:
1: No Connect
4: No Connect
7: No Connect
2: TX
5: GND
8: No Connect
3: RX
6: No Connect
9: No Connect
The serial communication uses the standard NRZ form, 1 starts bit, 8 data bits,
1 stop bit and the baud rate is 38400.
2) LAN communication interface
Adopt RJ45 standard connector, the pin definitions as follow:
1: TX+
4: No Connect
7: No Connect
2: TX5: No Connect
8: No Connect
1
4
-
1
4
-
-
1
4
-
3: RX+
6: RX-
-
-
7.2Set up the Hyper Terminal
If you have not set up the Hyper Terminal in your Windows system, follow these
steps:
Click “start menuprogramaccessorycommunication Hyper Terminal”;
This results in the following screen:
Then you input your connection name, such as “SNMP38400”; and choose the serial
port to connect with your equipment. As follows:
Press the “OK” button shows the configuration page of serial port. As follows:
Change the serial port configuration to 38400-baud rate, 8 data bits, no parity bit, 1
stop bit, no data flow control, press the “OK” key, you have set up the Windows serial
port Hyper Terminal.
1
5
-
1
5
-
-
1
5
-
-
-
You can click “filesave” menu to save this configuration of Hyper Terminal for
later using.
Operating Parameter Configuration
Under the condition of power off, use the serial port lines to connect the RS232
port with the computer port. Open the Windows Hyper Terminal which you have set
up. Then turn on the power, you will see the p age as follows:
The application program starts normally. You can input your command in this page,
and then configure the operating parameter of the application p rogram.
System supports the fo llowing commands:
help
ethcfg
settrap
setatt
List internal commands of the system;
Configure the Ethernet operating parameter;
Configure the aim host IP address o f the SNMP Trap;
Show or modify the output attenuation.
1
6
-
1
6
-
-
1
6
-
-
-
Specific use as follows:
help
This command is used to show the current application program internal orders list as
follows:
You can also use the “help” command to show help information of other orders, su ch
as “help ethcfg”,ethcfg’s help information appears as follows:
ethcfg
This command configures the Ethernet parameters, including IP address, subnet mask,
gateway and physical address. You can refer to the help information for its using.
Direct input the command “ethcfg” as follow to see the parameters:
To set the IP address:
1
7
-
1
7
-
-
1
7
-
-
-
settrap
This command shows or modifies the aim host IP address lists of the SNMP Trap,
“settrap” command is used to display the current configured trap IP, as follows:
trap IP address set as follows:
setatt
This command is used to show or modify the ou tput attenuation. Specific use as
follows:
1
8
-
1
8
-
-
1
8
-
-
-
The attenuation range is 0-3dB.
1
9
-
1
9
-
-
1
9
-
-
-
7.3 WEB Network Management
Opening the IE browser and entering the equipment IP address leads to the following
interface:
Enter the user name admin and password 123456 (factory default), to show the
following interface:
There are 3 sub-interfaces:
1. Display Parameter interface: Describes the equipment display menu.
2. Set Parameter interface: Change the equipment parameters in this interface.
3. Modify password interface: Change the login password in this interface.
Click Set Parameter to open the following interface:
The Item shows the changeable parameters, Current—the current parameters;
New—select or enter the new parameters; Update—update the parameters.
The update steps: Find the item which needs to be changed, select a new value,
and click the Update button.
2
0
-
2
0
-
-
2
0
-
-
-
8. Installation debugging
8.1Unpack and Check
1. Ensure the package is not defaced. If it has any damage or water mark, please
contact local agency or carrier.
2. After unpacking, check equipments and accessories according to package list. Any
question, please contact local agency or our company.
3. If you think the equipment has been damaged, please don't electrify to avoid
worse damage. Please contact local agency or our company in time.
8.2 Instruments and tools
1. An optical power meter;
2. A digital multimeter;
3. A standard optical fiber test jumper (SC/APC);
4. Some absolute alcohol and medical cotton wool;
8.3 Installation steps
1. Before installing the equipment, please read the <User's manual> carefully and
install the equipment according to the <User's manual>. Note: For the man-made
damage and other all consequence caused by error installation that not according
to the <User's manual>, we will not be responsible and will not supply free
warranty.
2. Take out the device from the box; fix it to the rack and reliably grounding. (The
grounding resistance must be < 4Ω).
3. Use the digital multimeter to check the supply voltage, make sure the supply
voltage comply with the requirements and the switch key is on the “OFF”
position. Then connect the power supply.
4. Input the optical signal according to the d isplay message. Turn the switch key to
the “ON” position and observe the front panel LED status. After the pump
working status indicator turn into green, the device is working normal. Then press
the menu button on the front panel to check the working parameters.
5. Connect the optical power meter to the optical signal output end by the standard
optical fiber test jumper, then measure the optical output power. Affirm the
measured optical output power and the displayed power are the same and have
reached the nominal value. (Affirm the optical power meter is on 1550nm
wavelength test position; the optical fiber test jumper is the matched one and on
the connector surface has no pollution.) Remove the standard optical fiber test
jumper and optical power meter; connect the device to the network. So far, the
device has been completely installed and debugged.
2
1
-
2
1
-
-
2
1
-
-
-
9. Clean and maintenance method of the optical fiber active
connector
In many times, we consider the decline of the optical power as the equipment
faults, but actually it may be caused by that the optical fiber connector was polluted
by dust or dirt. Inspect the fiber connector, component, or bulkhead with a fiberscope.
If the connector is dirty, clean it with a cleaning technique following these steps:
1. Turn off the device power supply and carefully pull off the optical fiber connector
from the adapter.
2. Wash carefully with good quality lens wiping paper and medical absorbent
alcohol cotton. If use the medical absorbent alcohol cotton, still need to wait 1~2
minutes after wash, let the connector surface dry in the air.
3. Cleaned optical connector should be connected to optical power meter to measure
optical output power to affirm whether it has been cleaned up.
4. When connect the cleaned optical connector back to adapter, should notice to
make force appropriate to avoid china tube in the adapter crack.
5. If the optical output power is not normal after cleaning, should pull off the
adapter and clean the other connector. If the optical power still low after cleaning,
the adapter may be polluted, clean it. (Note: Be carefully when pull off the
adapter to avoid hurting inside fiber.)
6. Use compressed air or degrease alcohol cotton to wash the adapter carefully.
When use compressed air, the muzzle aims at china tube of the adapter, clean the
china tube with compressed air. When use degrease alcohol cotton, insert
directions need be consistent, otherwise can’t reach a good clean effect.
Special notice:
a. In the process o f clean the active optical fiber connector, you should avoid
direct shining at eye, which will cause permanence burn!!!!
b. Use proper energy to install the active optical connector, o r the ceramic tape
in the adaptor will lead to break. Once the ceramic tape is broken, the
optical output power will decrease rapidly. And turn the active optical fiber
connector slightly, the optical output power changes obviously.
c. Please operate the optical fiber under the condition of shut off the pump
laser. Or the high output power will lead to burn the joint of the optical
output fiber, which will cause the output power decrease.
2
2
-
2
2
-
-
2
2
-
-
-
10. After-sales Service Description
1. If the equipment fault is resulted from the u sers’ improperly operation or
unavoidable environment reasons, we will responsible maintenance but ask
suitable material cost.
2. When the equipment breaks down, immediately contact MONDO PLAST.
3. The site maintenance of the fault equipment must be operated by professional
technicians to avoid worse damage.
Special notice: If the equipment has been maintained by users, we will not responsible
free maintenance. We will ask suitable maintenance cost and material cost.
11. Disclaimer
We reserve the right to change any products described herein at any time, and without
prior notice. We assume no responsibility or liability arising from the use of the
products described herein, except as expressly agreed to in writing by us. The use and
purchase of this product does not convey a license under any patent rights, copyrights,
trademark rights, or any intellectual property rights of us. Nothing hereunder
constitutes a representation or warranty that using any products in the manner
described herein will not infringe any patents of third parties.
2
3
-
2
3
-
-
2
3
-