Newco NKT3, NKT Installation Manual

NEWCO ENTERPRISES
INSTALLATION and OPERATION MANUAL FOR
&
NKT3 COMBINATION COFFEE
TEA BREWER
Man Pt No 705885
Rel 3-02
Model
NKT3
Coffee/Tea 9.5”
Depth
1
g-718” 30-518”
Height
Weight
40 Ibs
Voltage
120
Watts
1750
Amps
15
WARRANTY
Newco coffee brewers are warranted against defects in workmanship or materials, under normal use, for 90
days from the date of purchase. Brewer parts are warranted against defect for 12 months from date of purchase.
Liability in all events is limited to the purchase price paid and liability under the aforesaid warranty is limited to replacing or repairing any part or parts which are defective in material or workmanship, and returned to our factory, shipping cost prepaid. No warranty expressed or implied, other than the aforesaid is made or authorized by Newco Enterprises, Inc.
Prompt disposition will be made if item proves to be defective, within warranty. Before returning any item, write or call Newco, or the dealer from whom the product was purchased, giving model number, serial number, and date of purchase, and describe the nature of the defect. If damage was incurred during transit to you, file claim with the carrier.
PLUMBER’S INSTALLATION INSTRUCTIONS
II
1)
Attach flow/strainer assembly to back of brewer. Strainer inlet will point down.
2)
Flush water line before installing brewer. Brewer should be connected to COLD WATER LINE for best operation.
3)
Water pressure should be at least 20 Ibs. For less than a 25 ft run, use
larger water line. For longer runs, use adapter fitting for connection to the brewer.
4)
If installed with saddle valve, the valve should have a minimum of hole for over 25
5)
Connect incoming water line to the PDS valve refer to PDS supplement sheet P/N 110515 on the back of the brewer. Manufacturer recommends connecting to copper tubing
CAUTION: Power to brewer must be OFF before proceeding with plumbing installation.
114”
copper tubing and connect to
3/8”
fi
runs.
copper tubing & connect to
l/2”
or larger water line and provide an
l/8”
port hole for up to 25 ft run, and
INSTALLATION INSTRUCTIONS
WARNING:
Warranty will be void if machine is connected to any voltage other than that specified on the name plate.
This unit is designed for brewing both TEA and COFFEE. The initial operating instructions must be followed in
order, and completely, to have a properly adjusted brewer that will perform both functions.
1)
Remove the front access panel from the brewer.
2)
Place tea dispenser in position below brew basket. Raise the top evaporation cover and pour three decanters of water through the top pour-in screen. Water should come through the brew basket as the third decanter of water drains out of the pour in basin. If the brewer does not have a pour in opening remove top cover and pour water directly into receiving pan. Empty tea dispenser.
3)
Connect the brewer to a proper voltage circuit as noted on the serial tag.
-
Read and follow installation instructions before plugging or wiring in machine to electrical circuit.
FILL BREWER TANK WITH WATER BEFORE CONNECTING TO POWER SUPPLY !
l/2”
5/16”
II
.
or
port
TEA CALIBRATION
4)
Turn the power switch on brewer faceplate to the ON position. Turn selector switch to the Iced Tea position.
5)
Start the brew cycle by pressing the brew start switch. The tea dispenser should fill with one brew cycle. If
adjustment is required due to over or under filling locate the timer control in the component panel at the rear of brewer. The timer has two adjustment knobs, one marked TEA and the other marked COFFEE. Using the tea knob, adjust the timer to deliver the desired amount of water. Turn timer dial clockwise to increase volume of water, and counter clockwise to decrease the volume.
6)
The brewer should deliver approximately 75ounces of hot water concentrate through the sprayhead with the balance of the 3 gallons passing as cold water through the dilution tube. Turning the needle valve on the lower solenoid valve counterclockwise increase strength while clockwise rotation will decrease strength.
7)
Drain and remove the tea dispenser.
COFFEE CALIBRATION
8)
Place a coffee dispenser in position below brew basket.
9)
Turn selector switch to the Coffee or Hot Tea position.
10)
Start the brew cycle by pressing the brew start switch. The coffee dispenser should fill with one brew cycle. If adjustment is required due to over or under filling locate the timer control in the component area of the brewer. This time use the adjustment knob marked COFFEE to adjust the timer to deliver the desired amount of water. Turn timer dial clockwise to increase volume of water, and counter clockwise to decrease the volume. Empty the coffee dispenser.
11)
Note: 240 V brewers are shipped with the thermostat turned OFF. Rotate thermostat knob to full on position and then back about
12)
After adjustments are complete, disconnect the power supply and then replace any panels or covers previously
removed. Reconnect the power supply.
13)
Allow 10 to 15 minutes for water in tank to heat to brewing temperature. (Additional water may drip from brew
basket on initial expansion of water in the tank). This will not occur thereafter.
I!“.
120 V Brewers are shipped with thermostat turned on.
Continued on next page