Newco GXF2-30 Operators Manual

2Man Pt No 701528
REV 10-01
N E W C O E N T E R P R I S E S
INSTALLATION and OPERATION MANUAL for GX SERIES BREWERS
GXF3-15 GXF-8D
BREWER SPECIFICATIONS
GXF1-15 1 9-1/2" 19" 20-3/4 12.7 24.1 10.8 20.3 GXF1-30 1 9-1/2" 19" 26-3/8 12.7 24.1 10.8 20.3 GXF2-15 2 9-1/2" 19" 22-3/8 13.5 24.9 11.6 21.1 GXF2-30 2 9-1/2" 19" 28 13.5 24.9 11.6 21.1 GXF3-15 3 9-1/2" 19" 22-3/8 14.4 25.8 12.5 22 GXF3-30 3 9-1/2" 19" 28 14.4 25.8 12.5 22 GXF-P N/A 9-1/2" 19" 25-1/8 11.7 23.3 9.8 19.5 GXF-T N/A 9-1/2" 19" 32-9/16 11.7 23.3 9.8 19.5 GXF-TD N/A 9-1/2" 19" 27-11/16 11.7 23.3 9.8 19.5 GXF-8D N/A 9-1/2" 19" 30-3/16 11.7 23.3 9.8 19.5
* Height does not include the 4” adjustable legs. Add approximately 4” to the height shown when using these legs. NOTE: Automatic models without faucet and non plumbed in units are also available.
No of
Warmers Width Length Height*
Shipping weight is approximately 50 pounds f or al l above uni ts
US
120V
Amps
US
120/240V
Amps
Canada
120V
Amps
Canada
120/240V
Amps
PLUMBER'S INSTALLATION INSTRUCTIONS (AUTOMATIC BREWERS)
CAUTION: Power to brewer must be OFF before proceeding with plumbing installation.
1) Attach strainer assembly to back of brewer if desired. Note: Faucet units will have a mini arrestor installed on the back of the brewer to which strainer should be attached. Strainer inlet will point down.
2) Flush water line before installing brewer. Brewer should be connected to COLD WATER LINE for best operation.
3) Water pressure should be at least 20 lbs. For less than a 25 ft run, use 1/4" copper tubing and connect to 1/2" or larger water line. For longer runs, use 3/8" copper tubing & connect to 1/2" or larger water line and provide an adapter fitting for connection to the brewer.
4) If installed with saddle valve, the valve should have a minimum of 1/8" port hole for up to 25 ft run, and 5/16" port hole for over 25 ft runs.
5) Connect incoming water line to the strainer on the back of the brewer. Manufacturer recommends connecting to copper tubing.
ELECTRICAL HOOKUP
FILL BREWER TANK WITH WATER BEFORE CONNECTING TO POWER SUPPLY !
WARNING: - Read and follow installation instructions before plugging or wiring in machine to electrical circuit.
Warranty will be void if machine is connected to any voltage other than that specified on the name plate. This brewer is Voltage Convertible and may be hooked up to either a 120V ac or 240V ac single phase circuit. The
pictorial view on the next page illustrates the power cord connection to the terminal block for both circuits. A wiring diagram on the rear of this manual illustrates the complete brewer wiring. Kits required for converting between the voltages, along with an assembly illustration, are shown on the next page.
Note that on 240 V circuits the tank heater system is the only portion of the brewer running on 240V. The balance of components are powered by 120V obtained by tapping one leg, L1, of the circuit. Refer to the wiring diagram on the back page for hookup of other internal wiring in brewer. Note that the position of the orange wire with the white stripe is the only change to internal wiring between 120V and 240V hookup. The orange wire with white stripe should be positioned on the Neutral terminal of the terminal block for 120 V operation and L2 for 240 V operation.
To attach power cord or conduit:
1) Remove the front access panel covering component area by removing the four retaining screws. 2 Locate the cord plate (Pg 3, Item A) on rear of unit and remove the two screws retaining it. Remove the cord plate.
3) Note the cord plate serves multiple functions as a cord plate, heat shield and as a feed through device to assist in feeding the cord from the rear of brewer to the front component area. Note that 120V units will have an adaptor plate also (Pg 3, Item 3).
For 120V units remove the cable connector (Pg 3 Item 7) if present. Insert the power cord and plate assembly (Pg 3,
Item 4) through the cord plate/shield (Pg 3, Item A) and through the bushing (Pg 3, Item B) at the other end of shield.
For 240 V units remove the power cord and plate assembly if present (Pg 3, Item 4). Attach cable connector/strain relief (Pg 3, Item 8) to the cord plate/shield if not already present. Insert appropriate power cord/conduit through the cord plate/shield. Feed wire leads through bushing at other end of shield.
4) Using the cord plate/shield, guide cord through terminal block access hole and reattach cord plate, and adapter plate on 120 V models, to the brewer.
2
ELECTRICAL HOOKUP (CONT’D)
5) Make electrical connections as shown below and on the wiring diagram on the back of manual. Tighten strain relief as applicable.
6) If the brewer has been converted from the original voltage as shown on the serial tag it will be necessary to apply the appropriate electrical rating decal (Pg 3, Items 5 and 8) in place on the serial tag to cover the previous rating.
Item Part No Description
1 701555 Cord, 15 A 2 101035 Strain Relief, 15 A 3 511005 Plate, Adapter 15 A 4 701467 Cord/Plate Assy 15 A Includes 1,2 and 3 5 701468 Label, Electrical Rating, 120 V 6 701466 Kit, GX Perm to Cord Includes 4 and 5 7 511054 Cable Connector 8 701471 Label, Electrical Rating, 120/240 V 9 701469 Kit, GX Cord to Perm Includes 7 and 8
INSTALLATION INSTRUCTIONS WARNING: - Read and follow installation instructions before plugging or wiring in machine to electrical circuit.
REFER TO THE ILLUSTRATION ON PAGE 6 FOR LOCATION OF REFERENCED COMPONENTS
1) Place the decanter under brew basket, raise top evaporation cover and pour four decanters of water through the top
pour-in screen. Water should come through the brew basket as the fourth decanter of water drains out of the pour in basin. If brewer does not have a pour in opening remove top cover and pour water directly into receiving pan. The brewer tank is now full and the unit may be plugged into or wired to an appropriate voltage circuit as indicated on the serial tag.