BF Series Brewer Operation Manual
BF Series Man Pt No 800397
Iss 20130429
Brewer Dimensions and Warmer Configuration Table
Vessel BF Series Models Cabinet Dimensions Warmer Location
Type Pourover Automatic Faucet Height Width Depth Cover Base
Glass Bowl BF3 BF3A BF3AF 18.1 8.5 16.9 2 1
Glass Bowl BFLP3 BFLP3A BFLP3AF 17.1 16.4 16.9 0 3
3 Gal Tea Urn BFT3 BFT3AF 32.3 11 19.4 N/A N/A
5 Gal Tea Urn BFT5 BFT5AF 35.3 11 19.4 N/A N/A
Electrical Ratings Table
Brewer Type BF Series Models Max Electrical Rating Canadian
120V - W & A 240V - W & A 120V - W & A
3 Station Inline BF3, BF3A, BF3AF 1700 14.2 3800 17.1 1400 11.7
3 Station Low
Profile BFLP3, BFLP3A, BFLP3AF 1700 14.2 3800 17.1 1400 11.7
3 Gallon Tea BFT3, BFT3AF 1750 14.6 3500 14.6 1400 11.7
5 Gallon Tea BFT5, BFT5AF 1750 14.6 3500 14.6 1400 11.7
1
BF Series Man Pt No 800397
Iss 20130429
INSTALLATION / SETUP INSTRUCTIONS
WARNING: - Read and follow all installation / setup instructions before plugging or wiring in
machine to electrical circuit. Tank must be filled prior to connecting brewer to electrical circuit.
Warranty will be void if machine is connected to any voltage other than that specified on the
name plate. Brewer must be level.
Plumber's Installation Instructions
1) Brewer must be installed to comply with all applicable federal, state and local plumbing
codes and ordinances.
2) Plumb brewer in to water supply using 1/4 inch copper tubing. Flush water line before
installing brewer to remove sediment. Brewer should be connected to COLD WATER
LINE for best operation.
3) Water pressure should be at least 20 lbs. For less than a 25 ft run, use 1/4" tubing and
connect to 1/2" or larger water line. The inlet water fitting on the back of the brewer is a
1/4" flare fitting. It may be necessary to remove the plumbing cover box on the rear of
brewer to access water connection point.
4) If installed with saddle valve, the valve should have a minimum of 1/8" port hole for up
to 25 ft run, and 5/16" port hole for over 25 ft runs.
5) Check for leaks. Replace plumbing cover box on rear and front access panel if
removed previously.
Installation / Setup Instructions continue on next page